ObservationInspiredOxygenLite

Introduction

The ObservationInspiredOxygenLite profile represents the inspired oxygen of the patient in relation of the saturation. The profile created from the resource Observation.

Intended Use

The ObservationInspiredOxygenLite is used for communicating if the patient has received oxygen or not. It is only used in relation to the observationOxygenSaturationLite. The profile should therefore only be used as a contained resource.

If this profile is included in the payload of the Oxygen saturation it should be interpreted as if the patient has received oxygen. The flow rate of the inspired oxygen is sent in Observation.Value element. It is optional.

ObservationInspiredOxygenLite is only used as a part of the Oxygen saturation API.

Profile Overview

ObservationInspiredOxygenLite

idΣ0..1string
id0..1string
extensionI0..*Extension
versionIdΣ0..1id
lastUpdatedΣ0..1instant
sourceS Σ0..1uri
profileΣ1..1canonical(StructureDefinition)
securityΣ0..*CodingBinding
tagΣ0..*Coding
implicitRulesΣ ?!0..1uri
language0..1codeBinding
text0..1Narrative
contained0..0Resource
extensionI0..*Extension
modifierExtension?! I0..*Extension
basedOnΣ I0..0Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)
partOfΣ I0..0Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)
statusΣ ?!1..1codeBinding
category0..0CodeableConceptBinding
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ1..1uriFixed Value
versionΣ0..1string
codeΣ1..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
focusΣ I0..0Reference(Resource)
issuedΣ0..0instant
performerΣ I0..0Reference(Practitioner | Organization | CareTeam | Patient | RelatedPerson)
valueCodeableConceptCodeableConcept
valueStringstring
valueBooleanboolean
valueIntegerinteger
valueRangeRange
valueRatioRatio
valueSampledDataSampledData
valueTimetime
valueDateTimedateTime
valuePeriodPeriod
id0..1string
extensionI0..*Extension
valueΣ1..1decimal
comparatorΣ ?!0..1codeBinding
unitΣ1..1stringFixed Value
systemΣ I1..1uriFixed Value
codeΣ1..1codeFixed Value
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ1..1uriFixed Value
versionΣ0..1string
codeΣ1..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
interpretation0..0CodeableConceptBinding
note0..0Annotation
bodySite0..0CodeableConcept
method0..0CodeableConcept
specimenI0..0Reference(Specimen)
deviceI0..0Reference(Device | DeviceMetric)
hasMemberΣ I0..0Reference(Observation | QuestionnaireResponse | MolecularSequence)
derivedFromΣ I0..0Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)

Statuses

FHIR status Status in COSMIC
preliminary unsigned
final signed, completedNonSignable
entered-in-error invalidated
cancelled removed

Must be the same status as the profile in which this profile is contained.

Terminology Bindings

The ObservationInspiredOxygenLite profile is bound with a SNOMED CT code sent in Observation.code. | 371825009 | Inspired Oxygen (observable entity) |

Supported Operations

No supported operations since this profile is only used as a contained resource.

HTTP Methods

Query Operations

Search Parameters

Supported Queries

Supported SearchInclude Operations

Supported RevInclude Operations