ObservationLeftTesticularVolumeLite

Introduction

The ObservationLeftTesticularVolumeLite profile represents the parameter Left testicular volume and is a profile created from the resource Observation which makes the profile compliant with the FHIR standardized way of communicating vital sign data. Left testicular volume is an observation to record the volume of the left testicle, measured in milliliters.

Intended Use

The profile Left testicular volume  is used for communicating the volume of the left testicle, measured in milliliters, by sending a value in the element observation.value.

**Read Left Testicular Volume **

Intended use is in first hand that the API is applied for direct access and should not be used to transfer data between caregivers. If it should be used for copying inbetween care givers patient consent must be handled outside the API.

Specific Rules and Limitations

Type Description
Rule This API should not be used to transfer data between caregivers.
Rule If the performer is Patient, the subject should be the same as given performer.

Profile Overview

ObservationLeftTesticularVolumeLite

identifierΣ0..*Identifier
statusΣ ?!1..1codeBindingFixed Value
encounterΣ0..1Reference(Encounter)
note0..*Annotation

Statuses

User action in COSMIC FHIR status Status in COSMIC
Saved by signer preliminary ReadyToSign
Signed by signer final SignedComplete
Signed with counter signer and/or attester final Sign
Saved by secretary preliminary NotReadyToSign
Ready to sign by secretary preliminary ReadyToSign
Entered by patient final CompleteNonSignable
Parameter from a device final CompleteNonSignable
Correcting a previously signed parameter amended Resign
Remove a not signed parameter entered-in-error Deleted/Removed
Invalidate a signed parameter entered-in-error InvalidateComplete
Invalidate a parameter from a device or patient entered-in-error InvalidateComplete

Terminology Bindings

The ObservationLeftTesticularVolumeLite profile is bound with a SNOMED CT code sent in Observation.code: 65421000052108 | Testicular volume left (observable entity)|

Versions

COS version Profile version Required COSMIC version Date Description
3.0.0 1.1.0 R8.3.05 May 2022 Initial version, support for GET

Supported Operations

HTTP methods

Method Description
GET Used to get or search for registrations of Left testicular volume

Query operations

Search parameters

Parameter Format Mandatory Comment
code token No SNOMED CT code of the observation type
patient reference No The subject that the observation is about (if patient). The reference can be a literal reference ex: subject=1 or a Business identifier as well.ex: subject.identifier=urn:oid:1.2.752.129.2.1.3.1|20200109-6078

Supported Queries

  1. GET [baseURL]/Observation/?search?patient=&code= (Search)

Supported SearchInclude operations

No supported parameters

Supported RevInclude operations

Error codes

In the table below, a few error messages specific for observations are listed.

Code Description Comment
400 "Subject and Performer Patient references does not match."
400 "The date time: < date > is invalid" the dateTime must contain a time component