Autopsy Performed Indicator
Autopsy Performed Indicator is a profile of the FHIR STU3 Observation resource. It is used to convey a indication as to whether or not an autopsy was performed and whether the results of the autopsy were available for use in declaring the cause of death.
UML Expression
<center>
{{render:vrdr/vrdrautopsyperformedindicatorUML}}</center>
Structure Definition
{{profile:vrdr/vrdrautopsyperformedindicator, expand}}
Element Bindings
Element Name | Binding Type | Binding Value | Fixed Value Code System |
---|---|---|---|
code | Fixed Value | "85699-7" | LOINC |
component.Autopsy Results Available.code | Fixed Value | "69436-4" | LOINC |
component.Autopsy Results Available.valueCodeableConcept | Value Set | v2-0532 | |
status | Fixed Value | "final" | observation-status |
subject | Reference | VRDR Decedent | |
valueCodeableConcept | Value Set | v2-0532 |
Element Table
{{table:vrdr/vrdrautopsyperformedindicator, expand}}
Requirements Traceability Mappings
Element Path | Reference | Location | Data Item |
---|---|---|---|
valueCodeableConcept | Vital Records DAM | 2.1.01 Death Event | autopsyFindingsIndicator |
valueCodeableConcept | Vital Records DAM | 2.1.01 Death Event | autopsyPerformedIndicator |
valueCodeableConcept | Death Certificate | Item 33 | Was an Autopsy Performed? |
valueCodeableConcept | Death Certificate | Item 34 | Were Autopsy Findings Available to Complete the Cause of Death? |
valueCodeableConcept | Standard Death Record IG | SDR AutopsyPerformed Profile | Observation.valueBoolean |
valueCodeableConcept | Standard Death Record IG | SDR AutopsyResultsAvailable Profile | Observation.valueBoolean |
Instance Example
<Observation>
<id value="example-autopsy-performed-indicator" />
<meta>
<profile value="http://hl7.org/fhir/us/vrdr/StructureDefinition/VRDR-Autopsy-Performed-Indicator" />
</meta>
<status value="final" />
<code>
<coding>
<system value="http://loinc.org" />
<code value="85699-7" />
<display value="Autopsy was performed" />
</coding>
</code>
<subject>
<reference value="example-decedent" />
</subject>
<valueCodeableConcept>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136" />
<code value="N" />
<display value="No" />
</coding>
</valueCodeableConcept>
<component>
<code>
<coding>
<system value="http://loinc.org" />
<code value="69436-4" />
<display value="Autopsy results available" />
</coding>
</code>
<valueCodeableConcept>
<coding>
<system value="http://terminology.hl7.org/CodeSystem/v2-0136" />
<code value="N" />
<display value="No" />
</coding>
</valueCodeableConcept>
</component>
</Observation>