  • changed MII dependencies raised to the 2027 ballot releases: meta 2027.0.0-ballot.rc3, biobank 2027.0.0-ballot.rc2, base 2027.0.0-ballot.rc1
  • fix SNOMED CT display names corrected to the official designations (69 occurrences). Examples and ValueSets carried the Fully Specified Name including its bracketed suffix, e.g. Specimen vial (physical object) instead of Specimen vial
  • fix LOINC 94738-2: Biopsy site PatientBiopsy site [Anatomy]
  • fix ICD-O-3 8140/3: display set to Adenokarzinom o.n.A.
  • fix CI: the IG build now uses the MII terminology server (SU-TermServ) instead of the public HL7 fallback. The certificate secrets are read under the names the MII organisation uses; .github/fhir-settings.json allowlists the local proxy for the publisher
  • documentation input/ignoreWarnings.txt documents the 25 remaining findings: the IG Publisher reports enumerated ValueSet codes as invalid although SU-TermServ confirms them in the same run