Examples
Standard Bolus Example
NOTE to developer: This is only a sample resource. For the resource structure and valusets always refer the section "Overview" under each profile definition in the Implementation guide. If an element is defined as an array (0..*) in the standard and in RDC profile as an object (0..1), please note that it should still carry the structure of an array with one occurance. The structure for all resources as per the FHIR standard can be found at https://www.hl7.org/fhir/STU3/resourcelist.html
This FHIR example has been created from the following ACSPIX file tag:
<ADVICED_BOLUS type="Std">
<RECOMMENDED BgIU="6.5" CarbIU="0" TotalIU="6.5" />
<CONFIRMED BgIU="1.11" CarbIU="9.99" TotalIU="11.10"/>
<SELECTED BgIU="-0.11" CarbIU="1" TotalIU="0.89"/>
</ADVICED_BOLUS>
Extended Bolus Example
NOTE to developer: This is only a sample resource. For the resource structure and valusets always refer the section "Overview" under each profile definition in the Implementation guide. If an element is defined as an array (0..*) in the standard and in RDC profile as an object (0..1), please note that it should still carry the structure of an array with one occurance. The structure for all resources as per the FHIR standard can be found at https://www.hl7.org/fhir/STU3/resourcelist.html
This FHIR example has been created from the following ACSPIX file tag:
Complete JSON can be referred in Standard Bolus Example except advicedBolusType
<ADVICED_BOLUS type="Ext">
<RECOMMENDED BgIU="6.50" CarbIU="0.00" TotalIU="6.50" />
<CONFIRMED BgIU="1.11" CarbIU="9.99" TotalIU="11.10"/>
<SELECTED BgIU="-0.11" CarbIU="1.00" TotalIU="0.89"/>
</ADVICED_BOLUS>
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/advicedBolusType",
"valueCodeableConcept": {
"coding": [
{
"system": "http://roche.com/fhir/rdc/cs",
"code": "bolusExt",
"display": "Extended bolus"
}
]
}
},
Multiwave Bolus Example
NOTE to developer: This is only a sample resource. For the resource structure and valusets always refer the section "Overview" under each profile definition in the Implementation guide. If an element is defined as an array (0..*) in the standard and in RDC profile as an object (0..1), please note that it should still carry the structure of an array with one occurance. The structure for all resources as per the FHIR standard can be found at https://www.hl7.org/fhir/STU3/resourcelist.html
This FHIR example has been created from the following ACSPIX file tag:
Complete JSON can be referred in Standard Bolus Example except advicedBolusType
<ADVICED_BOLUS type="Mul">
<RECOMMENDED BgIU="6.50" CarbIU="0.00" TotalIU="6.50" />
<CONFIRMED BgIU="1.11" CarbIU="9.99" TotalIU="11.10"/>
<SELECTED BgIU="-0.11" CarbIU="1.00" TotalIU="0.89"/>
</ADVICED_BOLUS>
Complete JSON can be referred in Standard Bolus Example except advicedBolusType
{
"url":"http://roche.com/fhir/rdc/StructureDefinition/advicedBolusType",
"valueCodeableConcept":{
"coding": [
{
"system":"http://roche.com/fhir/rdc/cs",
"code":"bolusMulStd",
"display":"Bolus multiwave standard"
}
]
}
},