Sensor Raw Data- expanded FHIR
Case 1 - Median & Standard Deviation
Sample Scenario
| Data Point | Value | unit |
|---|---|---|
| medianCurrent10pA | 2 | pA |
| stdDevCurrent10pA | 3 | pA |
Note: Comments are provided in green in the JSON below
medianCurrent10pA :
{
"resourceType": "Observation",
"id": "defec78e-3889-49b8-98f8-672d17dbc307", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "medianCurrent10pA" is received in the reduced FHIR
{
"system": "http://snomed.info/sct",
"code": "260528009",
"display": "Median (qualifier value)"
}
],
"text": "medianCurrent10pA" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 2, //To be retained as is from the reduced format
"unit": "pA", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "pA"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
stdDevCurrent10pA :
{
"resourceType": "Observation",
"id": "e35dda82-8f60-43a7-8d67-ebf257a4dca5", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "stdDevCurrent10pA" is received in the reduced FHIR
{
"system": "http://snomed.info/sct",
"code": "386136009",
"display": "Standard deviation (qualifier value)"
}
],
"text": "stdDevCurrent10pA" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 3, //To be retained as is from the reduced format
"unit": "pA", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "pA"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
Case 2 -- Median & Std Deviation voltage counter
Sample Scenario
| Data Point | Value | unit |
|---|---|---|
| medianVpolCEWEmV | 50 | mV |
| stdDevVpolCEWE100uV | 83 | uV |
Note: Comments are provided in green in the JSON below
medianVpolCEWEmV - Median Voltage Counter Electrode Working Electrode CE WE
{
"resourceType": "Observation",
"id": "c8d45610-5421-4641-b65b-f47d1492b001", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "medianVpolCEWEmV" is received in the reduced FHIR
{
"system": "http://roche.com/fhir/rdc/cs",
"code": "median-voltage-counter",
"display": "Median Voltage Counter"
}
],
"text": "medianVpolCEWEmV" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 50, //To be retained as is from the reduced format
"unit": "mV", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "mV"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
stdDevVpolCEWE100uV - Standard Deviation Voltage Counter Electrode Working Electrode CE WE
{
"resourceType": "Observation",
"id": "5d10e96b-6a34-4aad-bb89-1bbb3ee1b3d8", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "stdDevVpolCEWE100uV" is received in the reduced FHIR
{
"system": "http://roche.com/fhir/rdc/cs",
"code": "Standard-deviation-voltage-counter",
"display": "Standard Deviation Voltage Counter"
}
],
"text": "stdDevVpolCEWE100uV" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 83, //To be retained as is from the reduced format
"unit": "uV", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "uV"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
Case 3 -- Battery voltage remaining
Sample Scenario
| Data Point | Value | unit |
|---|---|---|
| medianVbat10mVplus1200 | 178 | mV |
Note: Comments are provided in green in the JSON below
medianVbat10mVplus1200 - Remaining voltage of the battery.
{
"resourceType": "Observation",
"id": "9a766109-4415-4440-bf13-b18c775f26bd", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "medianVbat10mVplus1200" is received in the reduced FHIR
{
"system": "http://roche.com/fhir/rdc/cs",
"code": "battery-voltage-remaining",
"display": "Battery voltage remaining"
}
],
"text": "medianVbat10mVplus1200" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 178, //To be retained as is from the reduced format
"unit": "mV", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "mV"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
Case 4 -- Median & Std Impedence
Sample Scenario
| Data Point | Value | unit |
|---|---|---|
| medianImped1stOhm | 33195 | Ohm |
| medianImped2ndOhm | 33768 | Ohm |
| medianImped3rdOhm | 35772 | Ohm |
| stdDevImped1stOhm | 3870 | Ohm |
Note: Comments are provided in green in the JSON below
medianImped1stOhm - Median Impedance first point
{
"resourceType": "Observation",
"id": "5113a325-d1ec-4e50-9334-ca287f4daa2f", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "medianImped1stOhm" is received in the reduced FHIR
{
"system": "http://roche.com/fhir/rdc/cs",
"code": "impedance-median-first-point",
"display": "Impedance Median first point"
}
],
"text": "medianImped1stOhm" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 33195, //To be retained as is from the reduced format
"unit": "Ohm", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "Ohm"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
medianImped2ndOhm - Median Impedance second point
{
"resourceType": "Observation",
"id": "f7dc5dd7-eaa7-4ac3-b78d-1a004aec623b", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "medianImped2ndOhm" is received in the reduced FHIR
{
"system": "http://roche.com/fhir/rdc/cs",
"code": "impedance-median-second-point",
"display": "Impedance Median second point"
}
],
"text": "medianImped2ndOhm" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 33768, //To be retained as is from the reduced format
"unit": "Ohm", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "Ohm"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
medianImped3ndOhm - Median Impedance third point
{
"resourceType": "Observation",
"id": "241c0442-b3a4-465e-b1f9-ec358a1a203f", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "medianImped3rdOhm" is received in the reduced FHIR
{
"system": "http://roche.com/fhir/rdc/cs",
"code": "impedance-median-third-point",
"display": "Impedance Median third point"
}
],
"text": "medianImped3rdOhm" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 33768, //To be retained as is from the reduced format
"unit": "Ohm", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "Ohm"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
stdDevImped1stOhm - standard deviation Impedance first point
{
"resourceType": "Observation",
"id": "5610ca49-534a-45c0-b767-7eeeb719ae56", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "stdDevImped1stOhm" is received in the reduced FHIR
{
"system": "http://roche.com/fhir/rdc/cs",
"code": "impedence-standard-deviation-first-point",
"display": "Impedence Standard Deviation first point"
}
],
"text": "stdDevImped1stOhm" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 3870, //To be retained as is from the reduced format
"unit": "Ohm", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "Ohm"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
Case 5 - Median Temperature External & Internal
Sample Scenario
| Data Point | Value | unit |
|---|---|---|
| medianTempExternNTC100mDeg | 294 | mDeg |
| medianTempInternNTC100mDeg | 277 | mDeg |
Note: Comments are provided in green in the JSON below
medianTempExternNTC100mDeg - Median Temperature External
{
"resourceType": "Observation",
"id": "6b7831e8-4c28-4a0c-87ae-3fd3625fed6a", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "medianTempExternNTC100mDeg" is received in the reduced FHIR
{
"system": "http://roche.com/fhir/rdc/cs",
"code": "ntc-external-temperature",
"display": "NTC External Temperature"
}
],
"text": "medianTempExternNTC100mDeg" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 294, //To be retained as is from the reduced format
"unit": "mDeg", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "mDeg"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
medianTempInternNTC100mDeg - Median Temperature Internal
{
"resourceType": "Observation",
"id": "caa2f7b2-8249-4375-9b8a-013183a594c6", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "medianTempInternNTC100mDeg" is received in the reduced FHIR
{
"system": "http://roche.com/fhir/rdc/cs",
"code": "ntc-internal-temperature",
"display": "NTC Internal Temperature"
}
],
"text": "medianTempInternNTC100mDeg" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 277, //To be retained as is from the reduced format
"unit": "mDeg", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "mDeg"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}
Case 6 - sensorStatus , TimestampMinutes and CRC16
Sample Scenario
| Data Point | Value | unit |
|---|---|---|
| sensorStatus | 0 | n/a |
| timestampMinutes | 1 | min |
| CRC16 | 15850 | n/a |
Note: Comments are provided in green in the JSON below
{
"resourceType": "Observation",
"id": "e1967135-8846-4dc5-886a-cb204217e837", //To be managed by FHIRSTACK
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/device-event-observation" //To be added by facade - FHIR profile for sensor raw data
]
},
"identifier": [
{
"system": "http://roche.com/fhir/rdc/sid/observation/confidence",
"value": "<confidence unique identifier>" //retain same identifier received from Confidence reduced FHIR
}
],
"status": "final",
"category": [ //To be added by facade - system, code and display
{
"coding": [
{
"system": "http://ncimeta.nci.nih.gov",
"code": "CL540608",
"display": "Raw Data"
}
]
}
],
"code": {
"coding": [ //To be added by facade - system, code and display when code.text "stdDevCurrent10pA" is received in the reduced FHIR
{
"system": "http://snomed.info/sct",
"code": "386136009",
"display": "Standard deviation (qualifier value)"
}
],
"text": "stdDevCurrent10pA" //To be retained as is from the reduced format so that on restore it can be sent back
},
"subject": {
"reference": "Device/0053cfd5-a427-4691-8690-b4d956c6e698" //To be added by facade - Device link
},
"effectiveDateTime": "2021-12-09T00:00:30Z",
"performer": [
{
"reference": "Patient/2P0tI8p-SF9-6850" //To be added by facade - patient link
}
],
"valueQuantity": {
"value": 3, //To be retained as is from the reduced format
"unit": "pA", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "pA"
},
"related": [
{
"type": "derived-from",
"target": {
"reference": "Observation/1e6f0b94-1519-4f95-b50c-758fa3d4ac4b", // To be added by facade based on the target.display in the reduced FHIR. Link to the relevant CGM Session in Phase 1 and CGM data observation in Phase 2
"display": "AAAA"
}
}
],
"device": {
"reference": "DeviceMetric/0053cfd5-a427-4691-8690-b4d956c6e658" //To be added by facade - link to deviceMetric of relevant CGM sensor deviceComponent
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/sensor-status",
"valueString": "0" //Value corresponding to the "Sensor Status Annunciation" field provided in the CGMS specification.
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/timestamp-minutes",
"valueQuantity": {
"value": 1, //To be retained as is from the reduced format
"unit": "min", //To be retained as is from the reduced format
"system": "http://unitsofmeasure.org",
"code": "min"
}
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/crc",
"valueString": "15850" //Integrity value over this data set
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/patient-timezone",
"valueString": "+02:00"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>" //To be added by facade - fill channel data
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>" //To be added by facade - fill source data
}
]
}