Sensor Details
| Data Point | Value | unit | Comments |
|---|---|---|---|
| data → sensor → batch | 12345 | string | batch identification as string |
| data → sensor → sample location | subcutaneous | string | Location from which the values are measured. Possible values: "subcutaneous", "undetermined", "other" |
Possible optional datapoints provided in below example to map in fhir bundle if available.
For cases when sensor details are provided in RocheJson : RocheJson2FHIR mapper needs to create sensor device component and device metric resources.Mapper needs to point Transmitter devicecomponent as parent for sensor device component.
{
"resourceType": "DeviceComponent",
"id": "sensor-devicecomponent-001",
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/phd-devicecomponent"
]
},
"identifier": {
"system": "http://roche.com/fhir/rdc/sid/device-identifier",
"value": "<unique device identifier>"
},
"type": {
"coding": [{
"system": "http://snomed.info/sct",
"code": "701750003",
"display": "Subcutaneous glucose sensor"
}],
"text": "CGMSensor"
},
"source": {
"reference": "Device/sinovoapp-device-001"
},
"parent": {
"reference": "DeviceComponent/transmitter-devicecomponent-001"
},
"measurementPrinciple": "other",
"productionSpecification": [{
"specType": {
"coding": [{
"system": "http://ncimeta.nci.nih.gov",
"code": "C3641829",
"display": "Batch Number"
}]
},
"productionSpec": "12345"
},
{
"specType": {
"coding": [{
"system": "http://hl7.org/fhir/specification-type",
"code": "part-number",
"display": "Part Number"
}],
"text": "ModelNumber"
},
"productionSpec": "56789"
},
{
"specType": {
"coding": [{
"system": "http://hl7.org/fhir/specification-type",
"code": "unspecified",
"display": "Unspecified Production Specification"
}],
"text": "ModelName"
},
"productionSpec": "Aero"
}
],
"extension": [{
"url": "http://roche.com/fhir/rdc/StructureDefinition/sample-location",
"valueCodeableConcept": {
"coding": [{
"system": "http://ncimeta.nci.nih.gov",
"code": "C0278403",
"display": "Subcutis"
}],
"text": "SubcutaneousTissue"
}
}, {
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>"
}
]
}
DeviceMetric resource for each CGM sensor
This resource has to be created for each CGM Sensor DeviceComponent
{
"resourceType": "DeviceMetric",
"id": "sensor-device-metric-001",
"meta": {
"profile": [
"http://roche.com/fhir/rdc/StructureDefinition/dm-device-metric"
]
},
"identifier": { //build based on the deviceComponent identifier
"system": "http://roche.com/fhir/rdc/sid/devicemetric-identifier",
"value": "<deviceComponent.identifier.value>/2344-0"
},
"type": { //always same for CGM
"coding": [
{
"system": "http://loinc.org",
"code": "2344-0",
"display": "Glucose [Mass/volume] in Body fluid"
}
]
},
"unit": { //always same for CGM
"coding": [
{
"system": "http://unitsofmeasure.org",
"code": "mg/dL",
"display": "milligram per deciliter"
}
]
},
"source": {
"reference": "Device/sinovoapp-device-001"
},
"parent": {
"reference": "DeviceComponent/sensor-devicecomponent-001"
},
"operationalStatus": "on",
"category": "measurement",
"measurementPeriod": {
"repeat": {
"frequency": 1,
"period": 5,
"periodUnit": "min"
}
},
"extension": [
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
"valueString": "<channel-name>"
},
{
"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
"valueString": "<source-name>"
}
]
}