Default resources to be created

The following resources have to be created by the facade additionally in order to comply with RDC Implementation guide.

Patient

{
    "resourceType": "Patient",
    "id": "3f6AHVp-w86-1061",
    "meta": {
        "profile": [
            "http://roche.com/fhir/rdc/StructureDefinition/patient"
        ]
    },
    "identifier": [
        {
            "use": "official",
            "system": "http://roche.com/fhir/rdc/sid/pid/gigya",
            "value": "210527-confidence-dev"
        }
    ],
    "active": true
}


Device

There will be one Device resource for the ConfidenceApp integration

{
    "resourceType": "Device",
    "id": "confidence-1.0.0",
    "meta": {
        "profile": [
            "http://roche.com/fhir/rdc/StructureDefinition/phg-device"
        ]
    },
    "extension": [
            {
                "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
                "valueString": "confidence"
            },
            {
                "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
                "valueString": "confidence"
            }
    ],
    "status": "active",
    "type": {
        "coding": [
            {
                "system": "http://roche.com/fhir/rdc/cdf",
                "code": "cdf.dev.im",
                "display": "Manual interface"
            }
        ]
    },
    "manufacturer": "Roche",
    "model": "confidence",
    "version": "1.0.0"
}


DeviceComponent for a dummy SmartPhone

The ConfidenceApp does not share details of the smartphone on which the application is installed. However, we need a DeviceComponent for the smart phone to link the BG, Carb, Insulin etc. from the logbook.

{
    "resourceType": "DeviceComponent",
    "id": "cf.devicecomponent.3f6AHVp-w86-1061",
    "meta": {
        "profile": [
            "http://roche.com/fhir/rdc/StructureDefinition/phd-devicecomponent"
        ]
    },
    "extension": [
        {
            "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
            "valueString": "confidence"
        },
        {
            "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
            "valueString": "confidence"
        }
    ],
    "identifier": {
        "system": "http://roche.com/fhir/rdc/sid/device-identifier",
        "value": "confidence/<patient-id>"
    },
    "type": {
        "coding": [
            {
                "system": "http://roche.com/fhir/rdc/cs",
                "code": "smartPhone",
                "display": "Smart Phone"
            }
        ]
    },
    "lastSystemChange": "2021-06-01T00:00:00.000Z",
    "source": {
        "reference": "Device/confidence-1.0.0"
    }
}

DeviceMetric for BG/Calibration

A DeviceMetric resource is needed to link an Observation to a DeviceComponent.

{
    "resourceType": "DeviceMetric",
    "meta": {
        "profile":  [
                        "http://roche.com/fhir/rdc/StructureDefinition/dm-device-metric"
        ]
        },
    "extension": [
        {
            "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
            "valueString": "confidence"
        },
        {
            "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
            "valueString": "confidence"
        }
    ],
    "id": "cf.dmglucose.3f6AHVp-w86-1061",
    "identifier": {
        "system": "http://roche.com/fhir/rdc/sid/devicemetric-identifier",
        "value": "<deviceComponent.identifier.value>/2339-0"
    },
    "type": {
        "coding":  [
            {
                "system": "http://loinc.org",
                "code": "2339-0",
                "display": "Glucose [Mass/volume] in Blood"
            }
        ]
    },
    "unit": {
        "coding":  [
            {
                "system": "http://unitsofmeasure.org",
                "code": "mg/dL",
                "display": "milligram per deciliter"
            }
        ]
    },
    "source": {
        "reference": "Device/confidence-1.0.0"
    },
    "parent": {
        "reference": "DeviceComponent/cf.devicecomponent.3f6AHVp-w86-1061" //link to the dummy smartphone devicecomponent resource
    },
    "operationalStatus": "on",
        "category": "measurement"
}



DeviceMetric for Carb

A DeviceMetric resource is needed to link an Observation to a DeviceComponent.

{
    "resourceType": "DeviceMetric",
    "id": "cf.dmcarbs.3f6AHVp-w86-1061",
    "meta": {
        "profile":  [
            "http://roche.com/fhir/rdc/StructureDefinition/dm-device-metric"
        ]
    },
    "extension": [
        {
            "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
            "valueString": "confidence"
        },
        {
            "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
            "valueString": "confidence"
        }
    ],
    "identifier": {
        "system": "http://roche.com/fhir/rdc/sid/devicemetric-identifier",
        "value": "<deviceComponent.identifier.value>/2331003"
    },
    "type": {
        "coding":  [
            {
                "system": "http://snomed.info/sct",
                "code": "2331003",
                "display": "Carbohydrate (substance)"
            }
        ]
    },
    "unit": {
        "coding":  [
            {
                "system": "http://unitsofmeasure.org",
                "code": "g",
                "display": "gram"
            }
        ]
    },
    "source": {
        "reference": "Device/confidence-1.0.0"
    },
    "parent": {
        "reference": "DeviceComponent/cf.devicecomponent.3f6AHVp-w86-1061" //link to the dummy smartphone devicecomponent resource
    },
    "operationalStatus": "on",
    "category": "measurement" 
}



DeviceMetric for Insulin

A DeviceMetric resource is needed to link a MedcationAdministration to a DeviceComponent.

 {
        "id": "cf.dmins.3f6AHVp-w86-1061",
        "meta": {
            "profile":  [
                        "http://roche.com/fhir/rdc/StructureDefinition/dm-device-metric"
            ]
         },
        "extension": [
        {
            "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
            "valueString": "confidence"
        },
        {
            "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
            "valueString": "confidence"
        }
        ],
        "resourceType": "DeviceMetric",
        "identifier": {
            "system": "http://roche.com/fhir/rdc/sid/devicemetric-identifier",
            "value": "<deviceComponent.identifier.value>/67866001"
        },
        "type": {
            "coding":  [
                {
                    "system": "http://snomed.info/sct",
                    "code": "67866001",
                    "display": "Insulin (substance)"
                }
            ]
        },
        "unit": {
            "coding":  [
                {
                    "system": "http://unitsofmeasure.org",
                    "code": "[iU]",
                    "display": "international unit"
                }
            ]
        },
        "source": {
        "reference": "Device/confidence-1.0.0"
        },
        "parent": {
         "reference": "DeviceComponent/cf.devicecomponent.3f6AHVp-w86-1061" //link to the dummy smartphone devicecomponent resource
        },
        "operationalStatus": "on",
        "category": "measurement"
}



DeviceMetric for EMWR / Notes

A DeviceMetric resource is needed to link an Observation to a DeviceComponent. This is a dummy deviceMetric because errors/messages/Notes coming from an application do not have a specific deviceMetric

 {
        "id": "cf.dmemwr.3f6AHVp-w86-1061",
        "meta": {
            "profile":  [
                        "http://roche.com/fhir/rdc/StructureDefinition/dm-device-metric"
            ]
         },
        "extension": [
        {
            "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
            "valueString": "confidence"
        },
        {
            "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
            "valueString": "confidence"
        }
        ],
        "resourceType": "DeviceMetric",
        "identifier": {
            "system": "http://roche.com/fhir/rdc/sid/devicemetric-identifier",
            "value": "<deviceComponent.identifier.value>/10003008"
        },
       "type": {  
            "coding":  [
                {
                    "system": "http://snomed.info/sct",
                    "code": "10003008",
                    "display": "Non-specific (qualifier value)"
                }
            ]
        },
        "unit": {   
            "coding":  [
                {
                    "system": "http://ncimeta.nci.nih.gov",
                    "code": "C1272460",
                    "display": "Not Applicable"
                }
            ]
        },
        "source": {
        "reference": "Device/confidence-1.0.0"
        },
        "parent": {
         "reference": "DeviceComponent/cf.devicecomponent.3f6AHVp-w86-1061" //link to the dummy smartphone devicecomponent resource
        },
        "operationalStatus": "on",
        "category": "measurement"
}



Dummy DeviceComponent and DevceMetric for a Sensor if the Session data is shared before the Sensor data

If the session is shared before the sensor, the facade creates temporarily a dummy DeviceComponent and DeviceMetric until the actual sensor details is received. This is because the session Observation needs to be linked to the sensor deviceComponent. Once the sensor details are received the DeviceComponent and DeviceMetric are updated as per Sensor


{
	"resourceType": "DeviceComponent",
	"id": "cf.dccgm.xaHovTo-GZa-9.ZZZZ",
	"meta": {
		"profile": ["http://roche.com/fhir/rdc/StructureDefinition/phd-devicecomponent"]
	},
	"extension": [{
		"url": "http://roche.com/fhir/rdc/StructureDefinition/cgm-session-id",
		"valueString": "ZZZZ"
	}, {
		"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
		"valueString": "confidence"
	}, {
		"url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
		"valueString": "confidence"
	}],
	"identifier": {
		"system": "http://roche.com/fhir/rdc/sid/device-identifier",
		"value": "default-sensor/0130a615-4687-4e8f-ab6c-8df7e5fb48c6"
	},
	"type": {
		"coding": [{
			"system": "http://snomed.info/sct",
			"code": "701750003",
			"display": "Subcutaneous glucose sensor"
		}],
		"text": "CGMSensor"
	},
	"source": {
		"reference": "Device/confidence-1.0.0"
	},
	"parent": {
		"reference": "DeviceComponent/cf.globaldc.xaHovTo-GZa-9"
	}
}


{
    "resourceType": "DeviceMetric",
    "id": "cf.dmcgm.xaHovTo-GZa-9.ZZZZ",
    "meta": {
        "profile": [
            "http://roche.com/fhir/rdc/StructureDefinition/dm-device-metric"
        ]
    },
    "extension": [{
        "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-source",
        "valueString": "confidence"
    }, {
        "url": "http://roche.com/fhir/rdc/StructureDefinition/provenance-channel",
        "valueString": "confidence"
    }],
    "identifier": {
        "system": "http://roche.com/fhir/rdc/sid/devicemetric-identifier",
        "value": "default-sensor/0130a615-4687-4e8f-ab6c-8df7e5fb48c6/2344-0"
    },
    "type": {
        "coding": [{
            "system": "http://loinc.org",
            "code": "2344-0",
            "display": "Glucose [Mass/volume] in Body fluid"
        }]
    },
    "unit": {
        "coding": [{
            "system": "http://unitsofmeasure.org",
            "code": "mg/dL",
            "display": "milligram per deciliter"
        }]
    },
    "source": {
        "reference": "Device/confidence-1.0.0"
    },
    "parent": {
        "reference": "DeviceComponent/cf.dccgm.xaHovTo-GZa-9.ZZZZ"
    },
    "operationalStatus": "on",
    "category": "measurement"
}