Finnish PHR Heart Rate profile

Finnish PHR profile for FHIR® Observation used in heart rate measurements.

The profile is based on the Finnish PHR Vital Signs Base profile UPDATED. This profile alone does not describe all the elements needed and most of the elements are visible only in base profile. This profile describes changes to the base profile and the implementers must also familiarize themself with the base profile.

A full list of the extensions, constraints and a structured definition of this profile can be found in Simplifier. There are also different views of the profile (details, mappings, table, XML, JSON).

The Finnish PHR Heart Rate profile constrains the Finnish PHR Vital Signs Base Profile as follows:

Mandatory elements for Finnish PHR Heart Rate

Mandatory elements table Finnish PHR Blood Glucose profile
Content Name in structure Description / Type of information
Code for heart rate code All the codes are from the LOINC code system .
- A general code 8867-4 Heart rate SHALL always be given.
- In addition, one of the following optional codes MAY be given:
41924-2 Heart rate 24 hour mean
8883-1 Heart rate 24 hour minimum
8873-2 Heart rate 24 hour maximum.
Actual result valueQuantity The measured heart rate. SHALL always be provided with the unit of measurement /min (as in beats in a minute).

Optional elements for Finnish PHR Heart Rate

Mandatory elements table Finnish PHR Blood Glucose profile
Content Name in structure Type of information
Information about rhythm regularity extension:
HeartRateRhytm
Information about whether the heart rate rhythm is regular or irregular.
- Value true = the rhythm is regular.
- Value false = the rhythm is irregular.

Elements not in use for Finnish PHR Heart Rate

  • dataAbsentReason
  • component

Narrative guide

Narrative SHALL contain following mandatory information taken from the elements of the resource instance:

  • Code: <Observation.code.coding.display>(<Observation.code.coding.code>)
  • Time: <Observation.effectiveDateTime>
  • Result: <Observation.valueQuantity.value><Observation.valueQuantity.unit>

Narrative SHOULD contain following optional information if given in the resource instance:

  • Heart Rate Rhytm: <Observation.extension:HeartRateRhytm >
  • Interpretation: <Observation.interpretation.coding.display> (<Observation.interpretation.coding.code>)
  • Comment: <Observation.comment>
  • Method: <Observation.method>
  • Device: <Observation.device>
  • Reference range: <Observation.referenceRange>

If element is missing from resource, it shall not be mentioned in narrative.

Example:

Code: Heart rate (8867-4)
Time: 18.9.2017 12:01
Result: 66 /min
Heart Rate Rhytm: regular

Examples of Finnish PHR Heart Rate resources in Simplifier