Description |
---|
This profile defines the UK constraints and extensions on the International FHIR resource Composition. |
ProfilePurpose |
---|
This profile allows a record of a set of healthcare-related information that is assembled together into a single logical package that provides a single coherent statement of meaning, establishes its own context and that has clinical attestation with regard to who is making the statement. A Composition defines the structure and narrative content necessary for a document. However, a Composition alone does not constitute a document. Rather, the Composition SHALL be the first entry in a Bundle where |
Composition | I | Composition | Element IdComposition A set of resources composed into a single coherent clinical statement with clinical attestation DefinitionA set of healthcare-related information that is assembled together into a single logical package that provides a single coherent statement of meaning, establishes its own context and that has clinical attestation with regard to who is making the statement. A Composition defines the structure and narrative content necessary for a document. However, a Composition alone does not constitute a document. Rather, the Composition SHALL be the first entry in a Bundle where Bundle.type=document, and any other resources referenced from Composition SHALL be included as subsequent entries in the Bundle, for example Patient, Practitioner, Encounter, etc. While the focus of this specification is on patient-specific clinical statements, this resource can also apply to other healthcare-related statements such as study protocol designs, healthcare invoices and other activities that are not necessarily patient-specific or clinical.
| |
extension | I | 0..* | Extension | Element IdComposition.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Constraints
|
careSettingType | I | 0..1 | Extension(CodeableConcept) | Element IdComposition.extension:careSettingType The type of care setting associated with a composition or a list. Alternate namesextensions, user content DefinitionThe type of care setting associated with a composition or a list. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CareSettingType Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.identifier Version-independent identifier for the Composition DefinitionA version-independent identifier for the Composition. This identifier stays constant as the composition is changed over time. Similar to ClinicalDocument/setId in CDA. See discussion in resource definition for how these relate.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
status | Σ ?! | 1..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.status preliminary | final | amended | entered-in-error DefinitionThe workflow/clinical status of this composition. The status is a marker for the clinical standing of the document. Need to be able to mark interim, amended, or withdrawn compositions or documents. If a composition is marked as withdrawn, the compositions/documents in the series, or data from the composition or document series, should never be displayed to a user without being clearly marked as untrustworthy. The flag "entered-in-error" is why this element is labeled as a modifier of other elements. Some reporting work flows require that the original narrative of a final document never be altered; instead, only new narrative can be added. The composition resource has no explicit status for explicitly noting whether this business rule is in effect. This would be handled by an extension if required. The workflow/clinical status of the composition. CompositionStatus (required)Constraints
|
type | Σ | 1..1 | CodeableConceptBinding | Element IdComposition.type Kind of composition (SNOMED CT) DefinitionSpecifies the particular kind of composition (e.g. History and Physical, Discharge Summary, Progress Note). This usually equates to the purpose of making the composition. Key metadata element describing the composition, used in searching/filtering. For Composition type, LOINC is ubiquitous and strongly endorsed by HL7. Most implementation guides will require a specific LOINC code, or use LOINC as an extensible binding. SNOMED CT Document Type UKCoreDocumentType (preferred)Constraints
|
category | Σ | 0..* | CodeableConceptBinding | Element IdComposition.category Categorization of Composition DefinitionA categorization for the type of the composition - helps for indexing and searching. This may be implied by or derived from the code specified in the Composition Type. Further investgation is required about the usage of this element for UK Core. Helps humans to assess whether the composition is of interest when viewing an index of compositions or documents. This is a metadata field from XDS/MHD. A ValueSet to identify the category of a composition. UKCoreCompositionCategory (preferred)Constraints
|
subject | Σ I | 0..1 | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.subject Who and/or what the composition is about DefinitionWho or what the composition is about. The composition can be about a person, (patient or healthcare practitioner), a device (e.g. a machine) or even a group of subjects (such as a document about a herd of livestock, or a set of patients that share a common exposure). Essential metadata for searching for the composition. Identifies who and/or what the composition/document is about. For clinical documents, this is usually the patient.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.subject.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.subject.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.subject.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.subject.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.subject.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.subject.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.subject.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.subject.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.subject.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.subject.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
encounter | Σ I | 0..1 | Reference(UK Core Encounter) | Element IdComposition.encounter Context of the Composition DefinitionDescribes the clinical encounter or type of care this documentation is associated with. Provides context for the composition and supports searching. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.encounter.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.encounter.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.encounter.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.encounter.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.encounter.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.encounter.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.encounter.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.encounter.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.encounter.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.encounter.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
date | Σ | 1..1 | dateTime | There are no (further) constraints on this element Element IdComposition.date Composition editing time DefinitionThe composition editing time, when the composition was last logically changed by the author. dateTime is used for tracking, organizing versions and searching. Note that this is the time of authoring. When packaged in a document, Bundle.timestamp is the date of packaging. The Last Modified Date on the composition may be after the date of the document was attested without being changed.
|
author | Σ I | 1..* | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) | Element IdComposition.author Who and/or what authored the composition DefinitionIdentifies who is responsible for the information in the composition, not necessarily who typed it in. Identifies who is responsible for the content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.author.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.author.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.author.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.author.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.author.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.author.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.author.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.author.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.author.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.author.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
title | Σ | 1..1 | string | There are no (further) constraints on this element Element IdComposition.title Human Readable name/title DefinitionOfficial human-readable label for the composition. For many compositions, the title is the same as the text or a display name of Composition.type (e.g. a "consultation" or "progress note"). Note that CDA does not make title mandatory, but there are no known cases where it is useful for title to be omitted, so it is mandatory here. Feedback on this requirement is welcome during the trial use period.
|
confidentiality | Σ | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.confidentiality As defined by affinity domain DefinitionThe code specifying the level of confidentiality of the Composition. The exact use of this element, and enforcement and issues related to highly sensitive documents are out of scope for the base specification, and delegated to implementation profiles (see security section). This element is labeled as a modifier because highly confidential documents must not be treated as if they are not. Codes specifying the level of confidentiality of the composition. v3.ConfidentialityClassification (required)Constraints
|
attester | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.attester Attests to accuracy of composition DefinitionA participant who has attested to the accuracy of the composition/document. Identifies responsibility for the accuracy of the composition content. Only list each attester once.
| |
mode | 1..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.attester.mode personal | professional | legal | official DefinitionThe type of attestation the authenticator offers. Indicates the level of authority of the attestation. Note that FHIR strings SHALL NOT exceed 1MB in size The way in which a person authenticated a composition. CompositionAttestationMode (required)Constraints
| |
time | 0..1 | dateTime | There are no (further) constraints on this element Element IdComposition.attester.time When the composition was attested DefinitionWhen the composition was attested by the party. Identifies when the information in the composition was deemed accurate. (Things may have changed since then.).
| |
party | I | 0..1 | Reference(UK Core Patient | UK Core RelatedPerson | UK Core Practitioner | UK Core PractitionerRole | UK Core Organization) | Element IdComposition.attester.party Who attested the composition DefinitionWho attested the composition in the specified way. Identifies who has taken on the responsibility for accuracy of the composition content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(UK Core Patient | UK Core RelatedPerson | UK Core Practitioner | UK Core PractitionerRole | UK Core Organization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.attester.party.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.attester.party.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.attester.party.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.attester.party.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.attester.party.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
custodian | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.custodian Organization which maintains the composition DefinitionIdentifies the organization or group who is responsible for ongoing maintenance of and access to the composition/document information. Identifies where to go to find the current version, where to report issues, etc. This is useful when documents are derived from a composition - provides guidance for how to get the latest version of the document. This is optional because this is sometimes not known by the authoring system, and can be inferred by context. However, it is important that this information be known when working with a derived document, so providing a custodian is encouraged. Reference(UK Core Organization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.custodian.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.custodian.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.custodian.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.custodian.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.custodian.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.custodian.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.custodian.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.custodian.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.custodian.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.custodian.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
relatesTo | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.relatesTo Relationships to other compositions/documents DefinitionRelationships that this composition has with other compositions or documents that already exist. A document is a version specific composition.
| |
code | 1..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.relatesTo.code replaces | transforms | signs | appends DefinitionThe type of relationship that this composition has with anther composition or document. If this document appends another document, then the document cannot be fully understood without also accessing the referenced document. The type of relationship between documents. DocumentRelationshipType (required)Constraints
| |
target[x] | 1..1 | There are no (further) constraints on this element Element IdComposition.relatesTo.target[x] Target of the relationship DefinitionThe target composition/document of this relationship.
| ||
targetIdentifier | Identifier | Data Type | ||
targetReference | Reference(UK Core Composition) | Data Type | ||
event | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.event The clinical service(s) being documented DefinitionThe clinical service, such as a colonoscopy or an appendectomy, being documented. Provides context for the composition and creates a linkage between a resource describing an event and the composition created describing the event. The event needs to be consistent with the type element, though can provide further information if desired.
|
code | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdComposition.event.code Code(s) that apply to the event being documented DefinitionThis list of codes represents the main clinical acts, such as a colonoscopy or an appendectomy, being documented. In some cases, the event is inherent in the typeCode, such as a "History and Physical Report" in which the procedure being documented is necessarily a "History and Physical" act. An event can further specialize the act inherent in the typeCode, such as where it is simply "Procedure Report" and the procedure was a "colonoscopy". If one or more eventCodes are included, they SHALL NOT conflict with the values inherent in the classCode, practiceSettingCode or typeCode, as such a conflict would create an ambiguous situation. This short list of codes is provided to be used as key words for certain types of queries. This list of codes represents the main clinical acts being documented. v3.ActCode (example)Constraints
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.event.period The period covered by the documentation DefinitionThe period of time covered by the documentation. There is no assertion that the documentation is a complete representation for this period, only that it documents events during this time. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
detail | Σ I | 0..* | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.event.detail The event(s) being documented DefinitionThe description and/or reference of the event(s) being documented. For example, this could be used to document such a colonoscopy or an appendectomy. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.event.detail.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.event.detail.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.event.detail.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.event.detail.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.event.detail.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
section | I | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.section Composition is broken into sections DefinitionThe root of the sections that make up the composition.
|
title | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.title Label for section (e.g. for ToC) Alternate namesheader, label, caption DefinitionThe label for this particular section. This will be part of the rendered content for the document, and is often used to build a table of contents. Section headings are often standardized for different types of documents. They give guidance to humans on how the document is organized. The title identifies the section for a human reader. The title must be consistent with the narrative of the resource that is the target of the section.content reference. Generally, sections SHOULD have titles, but in some documents, it is unnecessary or inappropriate. Typically, this is where a section has subsections that have their own adequately distinguishing title, or documents that only have a single section. Most Implementation Guides will make section title to be a required element.
| |
code | 0..1 | CodeableConceptBinding | Element IdComposition.section.code Classification of section (recommended) DefinitionA code identifying the kind of content contained within the section. This must be consistent with the section title. Provides computable standardized labels to topics within the document. The code identifies the section for an automated processor of the document. This is particularly relevant when using profiles to control the structure of the document. If the section has content (instead of sub-sections), the section.code does not change the meaning or interpretation of the resource that is the content of the section in the comments for the section.code. Classification of a section of a composition/document. UKCoreCompositionSectionCode (extensible)Constraints
| |
author | I | 0..* | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) | Element IdComposition.section.author Who and/or what authored the section DefinitionIdentifies who is responsible for the information in this section, not necessarily who typed it in. Identifies who is responsible for the content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.author.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.section.author.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.section.author.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.author.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.author.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.section.author.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.author.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.section.author.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.section.author.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.author.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
focus | I | 0..1 | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.section.focus Who/what the section is about, when it is not about the subject of composition DefinitionThe actual focus of the section when it is not the subject of the composition, but instead represents something or someone associated with the subject such as (for a patient subject) a spouse, parent, fetus, or donor. If not focus is specified, the focus is assumed to be focus of the parent section, or, for a section in the Composition itself, the subject of the composition. Sections with a focus SHALL only include resources where the logical subject (patient, subject, focus, etc.) matches the section focus, or the resources have no logical subject (few resources). Typically, sections in a doument are about the subject of the document, whether that is a patient, or group of patients, location, or device, or whatever. For some kind of documents, some sections actually contain data about related entities. Typical examples are a section in a newborn discharge summary concerning the mother, or family history documents, with a section about each family member, though there are many other examples.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.focus.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.section.focus.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.section.focus.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.section.focus.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.focus.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
text | I | 0..1 | Narrative | There are no (further) constraints on this element Element IdComposition.section.text Text summary of the section, for human interpretation DefinitionA human-readable narrative that contains the attested content of the section, used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Document profiles may define what content should be represented in the narrative to ensure clinical safety.
|
mode | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.mode working | snapshot | changes DefinitionHow the entry list was prepared - whether it is a working list that is suitable for being maintained on an ongoing basis, or if it represents a snapshot of a list of items from another source, or whether it is a prepared list where items may be marked as added, modified or deleted. Sections are used in various ways, and it must be known in what way it is safe to use the entries in them. This element is labeled as a modifier because a change list must not be misunderstood as a complete list. The processing mode that applies to this section. ListMode (required)Constraints
| |
orderedBy | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.orderedBy Order of section entries DefinitionSpecifies the order applied to the items in the section entries. Important for presentation and rendering. Lists may be sorted to place more important information first or to group related entries. Applications SHOULD render ordered lists in the order provided, but MAY allow users to re-order based on their own preferences as well. If there is no order specified, the order is unknown, though there may still be some order. What order applies to the items in the entry. ListOrderCodes (preferred)Constraints
| |
entry | I | 0..* | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.section.entry A reference to data that supports this section DefinitionA reference to the actual resource from which the narrative in the section is derived. If there are no entries in the list, an emptyReason SHOULD be provided.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.entry.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.section.entry.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.section.entry.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.section.entry.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.entry.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
emptyReason | I | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.emptyReason Why the section is empty DefinitionIf the section is empty, why the list is empty. An empty section typically has some text explaining the empty reason. Allows capturing things like "none exist" or "not asked" which can be important for most lists. The various reasons for an empty section make a significant interpretation to its interpretation. Note that this code is for use when the entire section content has been suppressed, and not for when individual items are omitted - implementers may consider using a text note or a flag on an entry in these cases. If a section is empty, why it is empty. ListEmptyReasons (preferred)Constraints
|
section | I | 0..* | see (section) | There are no (further) constraints on this element Element IdComposition.section.section Nested Section DefinitionA nested sub-section within this section. Nested sections are primarily used to help human readers navigate to particular portions of the document.
|
Composition | I | Composition | Element IdComposition A set of resources composed into a single coherent clinical statement with clinical attestation DefinitionA set of healthcare-related information that is assembled together into a single logical package that provides a single coherent statement of meaning, establishes its own context and that has clinical attestation with regard to who is making the statement. A Composition defines the structure and narrative content necessary for a document. However, a Composition alone does not constitute a document. Rather, the Composition SHALL be the first entry in a Bundle where Bundle.type=document, and any other resources referenced from Composition SHALL be included as subsequent entries in the Bundle, for example Patient, Practitioner, Encounter, etc. While the focus of this specification is on patient-specific clinical statements, this resource can also apply to other healthcare-related statements such as study protocol designs, healthcare invoices and other activities that are not necessarily patient-specific or clinical.
| |
extension | I | 0..* | Extension | Element IdComposition.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Constraints
|
careSettingType | I | 0..1 | Extension(CodeableConcept) | Element IdComposition.extension:careSettingType The type of care setting associated with a composition or a list. Alternate namesextensions, user content DefinitionThe type of care setting associated with a composition or a list. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CareSettingType Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.identifier Version-independent identifier for the Composition DefinitionA version-independent identifier for the Composition. This identifier stays constant as the composition is changed over time. Similar to ClinicalDocument/setId in CDA. See discussion in resource definition for how these relate.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
status | Σ ?! | 1..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.status preliminary | final | amended | entered-in-error DefinitionThe workflow/clinical status of this composition. The status is a marker for the clinical standing of the document. Need to be able to mark interim, amended, or withdrawn compositions or documents. If a composition is marked as withdrawn, the compositions/documents in the series, or data from the composition or document series, should never be displayed to a user without being clearly marked as untrustworthy. The flag "entered-in-error" is why this element is labeled as a modifier of other elements. Some reporting work flows require that the original narrative of a final document never be altered; instead, only new narrative can be added. The composition resource has no explicit status for explicitly noting whether this business rule is in effect. This would be handled by an extension if required. The workflow/clinical status of the composition. CompositionStatus (required)Constraints
|
type | Σ | 1..1 | CodeableConceptBinding | Element IdComposition.type Kind of composition (SNOMED CT) DefinitionSpecifies the particular kind of composition (e.g. History and Physical, Discharge Summary, Progress Note). This usually equates to the purpose of making the composition. Key metadata element describing the composition, used in searching/filtering. For Composition type, LOINC is ubiquitous and strongly endorsed by HL7. Most implementation guides will require a specific LOINC code, or use LOINC as an extensible binding. SNOMED CT Document Type UKCoreDocumentType (preferred)Constraints
|
category | Σ | 0..* | CodeableConceptBinding | Element IdComposition.category Categorization of Composition DefinitionA categorization for the type of the composition - helps for indexing and searching. This may be implied by or derived from the code specified in the Composition Type. Further investgation is required about the usage of this element for UK Core. Helps humans to assess whether the composition is of interest when viewing an index of compositions or documents. This is a metadata field from XDS/MHD. A ValueSet to identify the category of a composition. UKCoreCompositionCategory (preferred)Constraints
|
subject | Σ I | 0..1 | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.subject Who and/or what the composition is about DefinitionWho or what the composition is about. The composition can be about a person, (patient or healthcare practitioner), a device (e.g. a machine) or even a group of subjects (such as a document about a herd of livestock, or a set of patients that share a common exposure). Essential metadata for searching for the composition. Identifies who and/or what the composition/document is about. For clinical documents, this is usually the patient.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.subject.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.subject.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.subject.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.subject.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.subject.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.subject.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.subject.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.subject.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.subject.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.subject.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
encounter | Σ I | 0..1 | Reference(UK Core Encounter) | Element IdComposition.encounter Context of the Composition DefinitionDescribes the clinical encounter or type of care this documentation is associated with. Provides context for the composition and supports searching. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.encounter.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.encounter.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.encounter.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.encounter.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.encounter.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.encounter.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.encounter.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.encounter.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.encounter.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.encounter.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
date | Σ | 1..1 | dateTime | There are no (further) constraints on this element Element IdComposition.date Composition editing time DefinitionThe composition editing time, when the composition was last logically changed by the author. dateTime is used for tracking, organizing versions and searching. Note that this is the time of authoring. When packaged in a document, Bundle.timestamp is the date of packaging. The Last Modified Date on the composition may be after the date of the document was attested without being changed.
|
author | Σ I | 1..* | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) | Element IdComposition.author Who and/or what authored the composition DefinitionIdentifies who is responsible for the information in the composition, not necessarily who typed it in. Identifies who is responsible for the content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.author.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.author.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.author.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.author.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.author.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.author.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.author.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.author.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.author.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.author.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
title | Σ | 1..1 | string | There are no (further) constraints on this element Element IdComposition.title Human Readable name/title DefinitionOfficial human-readable label for the composition. For many compositions, the title is the same as the text or a display name of Composition.type (e.g. a "consultation" or "progress note"). Note that CDA does not make title mandatory, but there are no known cases where it is useful for title to be omitted, so it is mandatory here. Feedback on this requirement is welcome during the trial use period.
|
confidentiality | Σ | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.confidentiality As defined by affinity domain DefinitionThe code specifying the level of confidentiality of the Composition. The exact use of this element, and enforcement and issues related to highly sensitive documents are out of scope for the base specification, and delegated to implementation profiles (see security section). This element is labeled as a modifier because highly confidential documents must not be treated as if they are not. Codes specifying the level of confidentiality of the composition. v3.ConfidentialityClassification (required)Constraints
|
attester | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.attester Attests to accuracy of composition DefinitionA participant who has attested to the accuracy of the composition/document. Identifies responsibility for the accuracy of the composition content. Only list each attester once.
| |
mode | 1..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.attester.mode personal | professional | legal | official DefinitionThe type of attestation the authenticator offers. Indicates the level of authority of the attestation. Note that FHIR strings SHALL NOT exceed 1MB in size The way in which a person authenticated a composition. CompositionAttestationMode (required)Constraints
| |
time | 0..1 | dateTime | There are no (further) constraints on this element Element IdComposition.attester.time When the composition was attested DefinitionWhen the composition was attested by the party. Identifies when the information in the composition was deemed accurate. (Things may have changed since then.).
| |
party | I | 0..1 | Reference(UK Core Patient | UK Core RelatedPerson | UK Core Practitioner | UK Core PractitionerRole | UK Core Organization) | Element IdComposition.attester.party Who attested the composition DefinitionWho attested the composition in the specified way. Identifies who has taken on the responsibility for accuracy of the composition content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(UK Core Patient | UK Core RelatedPerson | UK Core Practitioner | UK Core PractitionerRole | UK Core Organization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.attester.party.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.attester.party.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.attester.party.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.attester.party.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.attester.party.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
custodian | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.custodian Organization which maintains the composition DefinitionIdentifies the organization or group who is responsible for ongoing maintenance of and access to the composition/document information. Identifies where to go to find the current version, where to report issues, etc. This is useful when documents are derived from a composition - provides guidance for how to get the latest version of the document. This is optional because this is sometimes not known by the authoring system, and can be inferred by context. However, it is important that this information be known when working with a derived document, so providing a custodian is encouraged. Reference(UK Core Organization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.custodian.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.custodian.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.custodian.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.custodian.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.custodian.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.custodian.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.custodian.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.custodian.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.custodian.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.custodian.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
relatesTo | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.relatesTo Relationships to other compositions/documents DefinitionRelationships that this composition has with other compositions or documents that already exist. A document is a version specific composition.
| |
code | 1..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.relatesTo.code replaces | transforms | signs | appends DefinitionThe type of relationship that this composition has with anther composition or document. If this document appends another document, then the document cannot be fully understood without also accessing the referenced document. The type of relationship between documents. DocumentRelationshipType (required)Constraints
| |
target[x] | 1..1 | There are no (further) constraints on this element Element IdComposition.relatesTo.target[x] Target of the relationship DefinitionThe target composition/document of this relationship.
| ||
targetIdentifier | Identifier | Data Type | ||
targetReference | Reference(UK Core Composition) | Data Type | ||
event | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.event The clinical service(s) being documented DefinitionThe clinical service, such as a colonoscopy or an appendectomy, being documented. Provides context for the composition and creates a linkage between a resource describing an event and the composition created describing the event. The event needs to be consistent with the type element, though can provide further information if desired.
|
code | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdComposition.event.code Code(s) that apply to the event being documented DefinitionThis list of codes represents the main clinical acts, such as a colonoscopy or an appendectomy, being documented. In some cases, the event is inherent in the typeCode, such as a "History and Physical Report" in which the procedure being documented is necessarily a "History and Physical" act. An event can further specialize the act inherent in the typeCode, such as where it is simply "Procedure Report" and the procedure was a "colonoscopy". If one or more eventCodes are included, they SHALL NOT conflict with the values inherent in the classCode, practiceSettingCode or typeCode, as such a conflict would create an ambiguous situation. This short list of codes is provided to be used as key words for certain types of queries. This list of codes represents the main clinical acts being documented. v3.ActCode (example)Constraints
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.event.period The period covered by the documentation DefinitionThe period of time covered by the documentation. There is no assertion that the documentation is a complete representation for this period, only that it documents events during this time. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
detail | Σ I | 0..* | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.event.detail The event(s) being documented DefinitionThe description and/or reference of the event(s) being documented. For example, this could be used to document such a colonoscopy or an appendectomy. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.event.detail.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.event.detail.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.event.detail.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.event.detail.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.event.detail.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
section | I | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.section Composition is broken into sections DefinitionThe root of the sections that make up the composition.
|
title | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.title Label for section (e.g. for ToC) Alternate namesheader, label, caption DefinitionThe label for this particular section. This will be part of the rendered content for the document, and is often used to build a table of contents. Section headings are often standardized for different types of documents. They give guidance to humans on how the document is organized. The title identifies the section for a human reader. The title must be consistent with the narrative of the resource that is the target of the section.content reference. Generally, sections SHOULD have titles, but in some documents, it is unnecessary or inappropriate. Typically, this is where a section has subsections that have their own adequately distinguishing title, or documents that only have a single section. Most Implementation Guides will make section title to be a required element.
| |
code | 0..1 | CodeableConceptBinding | Element IdComposition.section.code Classification of section (recommended) DefinitionA code identifying the kind of content contained within the section. This must be consistent with the section title. Provides computable standardized labels to topics within the document. The code identifies the section for an automated processor of the document. This is particularly relevant when using profiles to control the structure of the document. If the section has content (instead of sub-sections), the section.code does not change the meaning or interpretation of the resource that is the content of the section in the comments for the section.code. Classification of a section of a composition/document. UKCoreCompositionSectionCode (extensible)Constraints
| |
author | I | 0..* | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) | Element IdComposition.section.author Who and/or what authored the section DefinitionIdentifies who is responsible for the information in this section, not necessarily who typed it in. Identifies who is responsible for the content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.author.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.section.author.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.section.author.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.author.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.author.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.section.author.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.author.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.section.author.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.section.author.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.author.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
focus | I | 0..1 | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.section.focus Who/what the section is about, when it is not about the subject of composition DefinitionThe actual focus of the section when it is not the subject of the composition, but instead represents something or someone associated with the subject such as (for a patient subject) a spouse, parent, fetus, or donor. If not focus is specified, the focus is assumed to be focus of the parent section, or, for a section in the Composition itself, the subject of the composition. Sections with a focus SHALL only include resources where the logical subject (patient, subject, focus, etc.) matches the section focus, or the resources have no logical subject (few resources). Typically, sections in a doument are about the subject of the document, whether that is a patient, or group of patients, location, or device, or whatever. For some kind of documents, some sections actually contain data about related entities. Typical examples are a section in a newborn discharge summary concerning the mother, or family history documents, with a section about each family member, though there are many other examples.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.focus.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.section.focus.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.section.focus.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.section.focus.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.focus.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
text | I | 0..1 | Narrative | There are no (further) constraints on this element Element IdComposition.section.text Text summary of the section, for human interpretation DefinitionA human-readable narrative that contains the attested content of the section, used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Document profiles may define what content should be represented in the narrative to ensure clinical safety.
|
mode | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.mode working | snapshot | changes DefinitionHow the entry list was prepared - whether it is a working list that is suitable for being maintained on an ongoing basis, or if it represents a snapshot of a list of items from another source, or whether it is a prepared list where items may be marked as added, modified or deleted. Sections are used in various ways, and it must be known in what way it is safe to use the entries in them. This element is labeled as a modifier because a change list must not be misunderstood as a complete list. The processing mode that applies to this section. ListMode (required)Constraints
| |
orderedBy | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.orderedBy Order of section entries DefinitionSpecifies the order applied to the items in the section entries. Important for presentation and rendering. Lists may be sorted to place more important information first or to group related entries. Applications SHOULD render ordered lists in the order provided, but MAY allow users to re-order based on their own preferences as well. If there is no order specified, the order is unknown, though there may still be some order. What order applies to the items in the entry. ListOrderCodes (preferred)Constraints
| |
entry | I | 0..* | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.section.entry A reference to data that supports this section DefinitionA reference to the actual resource from which the narrative in the section is derived. If there are no entries in the list, an emptyReason SHOULD be provided.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.entry.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.section.entry.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.section.entry.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.section.entry.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.entry.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
emptyReason | I | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.emptyReason Why the section is empty DefinitionIf the section is empty, why the list is empty. An empty section typically has some text explaining the empty reason. Allows capturing things like "none exist" or "not asked" which can be important for most lists. The various reasons for an empty section make a significant interpretation to its interpretation. Note that this code is for use when the entire section content has been suppressed, and not for when individual items are omitted - implementers may consider using a text note or a flag on an entry in these cases. If a section is empty, why it is empty. ListEmptyReasons (preferred)Constraints
|
section | I | 0..* | see (section) | There are no (further) constraints on this element Element IdComposition.section.section Nested Section DefinitionA nested sub-section within this section. Nested sections are primarily used to help human readers navigate to particular portions of the document.
|
Composition | I | Composition | Element IdComposition A set of resources composed into a single coherent clinical statement with clinical attestation DefinitionA set of healthcare-related information that is assembled together into a single logical package that provides a single coherent statement of meaning, establishes its own context and that has clinical attestation with regard to who is making the statement. A Composition defines the structure and narrative content necessary for a document. However, a Composition alone does not constitute a document. Rather, the Composition SHALL be the first entry in a Bundle where Bundle.type=document, and any other resources referenced from Composition SHALL be included as subsequent entries in the Bundle, for example Patient, Practitioner, Encounter, etc. While the focus of this specification is on patient-specific clinical statements, this resource can also apply to other healthcare-related statements such as study protocol designs, healthcare invoices and other activities that are not necessarily patient-specific or clinical.
| |
extension | I | 0..* | Extension | Element IdComposition.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Constraints
|
careSettingType | I | 0..1 | Extension(CodeableConcept) | Element IdComposition.extension:careSettingType The type of care setting associated with a composition or a list. Alternate namesextensions, user content DefinitionThe type of care setting associated with a composition or a list. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CareSettingType Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.identifier Version-independent identifier for the Composition DefinitionA version-independent identifier for the Composition. This identifier stays constant as the composition is changed over time. Similar to ClinicalDocument/setId in CDA. See discussion in resource definition for how these relate.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
status | Σ ?! | 1..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.status preliminary | final | amended | entered-in-error DefinitionThe workflow/clinical status of this composition. The status is a marker for the clinical standing of the document. Need to be able to mark interim, amended, or withdrawn compositions or documents. If a composition is marked as withdrawn, the compositions/documents in the series, or data from the composition or document series, should never be displayed to a user without being clearly marked as untrustworthy. The flag "entered-in-error" is why this element is labeled as a modifier of other elements. Some reporting work flows require that the original narrative of a final document never be altered; instead, only new narrative can be added. The composition resource has no explicit status for explicitly noting whether this business rule is in effect. This would be handled by an extension if required. The workflow/clinical status of the composition. CompositionStatus (required)Constraints
|
type | Σ | 1..1 | CodeableConceptBinding | Element IdComposition.type Kind of composition (SNOMED CT) DefinitionSpecifies the particular kind of composition (e.g. History and Physical, Discharge Summary, Progress Note). This usually equates to the purpose of making the composition. Key metadata element describing the composition, used in searching/filtering. For Composition type, LOINC is ubiquitous and strongly endorsed by HL7. Most implementation guides will require a specific LOINC code, or use LOINC as an extensible binding. SNOMED CT Document Type UKCoreDocumentType (preferred)Constraints
|
category | Σ | 0..* | CodeableConceptBinding | Element IdComposition.category Categorization of Composition DefinitionA categorization for the type of the composition - helps for indexing and searching. This may be implied by or derived from the code specified in the Composition Type. Further investgation is required about the usage of this element for UK Core. Helps humans to assess whether the composition is of interest when viewing an index of compositions or documents. This is a metadata field from XDS/MHD. A ValueSet to identify the category of a composition. UKCoreCompositionCategory (preferred)Constraints
|
subject | Σ I | 0..1 | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.subject Who and/or what the composition is about DefinitionWho or what the composition is about. The composition can be about a person, (patient or healthcare practitioner), a device (e.g. a machine) or even a group of subjects (such as a document about a herd of livestock, or a set of patients that share a common exposure). Essential metadata for searching for the composition. Identifies who and/or what the composition/document is about. For clinical documents, this is usually the patient.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.subject.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.subject.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.subject.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.subject.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.subject.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.subject.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.subject.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.subject.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.subject.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.subject.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
encounter | Σ I | 0..1 | Reference(UK Core Encounter) | Element IdComposition.encounter Context of the Composition DefinitionDescribes the clinical encounter or type of care this documentation is associated with. Provides context for the composition and supports searching. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.encounter.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.encounter.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.encounter.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.encounter.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.encounter.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.encounter.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.encounter.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.encounter.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.encounter.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.encounter.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
date | Σ | 1..1 | dateTime | There are no (further) constraints on this element Element IdComposition.date Composition editing time DefinitionThe composition editing time, when the composition was last logically changed by the author. dateTime is used for tracking, organizing versions and searching. Note that this is the time of authoring. When packaged in a document, Bundle.timestamp is the date of packaging. The Last Modified Date on the composition may be after the date of the document was attested without being changed.
|
author | Σ I | 1..* | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) | Element IdComposition.author Who and/or what authored the composition DefinitionIdentifies who is responsible for the information in the composition, not necessarily who typed it in. Identifies who is responsible for the content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.author.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.author.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.author.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.author.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.author.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.author.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.author.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.author.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.author.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.author.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
title | Σ | 1..1 | string | There are no (further) constraints on this element Element IdComposition.title Human Readable name/title DefinitionOfficial human-readable label for the composition. For many compositions, the title is the same as the text or a display name of Composition.type (e.g. a "consultation" or "progress note"). Note that CDA does not make title mandatory, but there are no known cases where it is useful for title to be omitted, so it is mandatory here. Feedback on this requirement is welcome during the trial use period.
|
confidentiality | Σ | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.confidentiality As defined by affinity domain DefinitionThe code specifying the level of confidentiality of the Composition. The exact use of this element, and enforcement and issues related to highly sensitive documents are out of scope for the base specification, and delegated to implementation profiles (see security section). This element is labeled as a modifier because highly confidential documents must not be treated as if they are not. Codes specifying the level of confidentiality of the composition. v3.ConfidentialityClassification (required)Constraints
|
attester | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.attester Attests to accuracy of composition DefinitionA participant who has attested to the accuracy of the composition/document. Identifies responsibility for the accuracy of the composition content. Only list each attester once.
| |
mode | 1..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.attester.mode personal | professional | legal | official DefinitionThe type of attestation the authenticator offers. Indicates the level of authority of the attestation. Note that FHIR strings SHALL NOT exceed 1MB in size The way in which a person authenticated a composition. CompositionAttestationMode (required)Constraints
| |
time | 0..1 | dateTime | There are no (further) constraints on this element Element IdComposition.attester.time When the composition was attested DefinitionWhen the composition was attested by the party. Identifies when the information in the composition was deemed accurate. (Things may have changed since then.).
| |
party | I | 0..1 | Reference(UK Core Patient | UK Core RelatedPerson | UK Core Practitioner | UK Core PractitionerRole | UK Core Organization) | Element IdComposition.attester.party Who attested the composition DefinitionWho attested the composition in the specified way. Identifies who has taken on the responsibility for accuracy of the composition content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(UK Core Patient | UK Core RelatedPerson | UK Core Practitioner | UK Core PractitionerRole | UK Core Organization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.attester.party.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.attester.party.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.attester.party.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.attester.party.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.attester.party.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.attester.party.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
custodian | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.custodian Organization which maintains the composition DefinitionIdentifies the organization or group who is responsible for ongoing maintenance of and access to the composition/document information. Identifies where to go to find the current version, where to report issues, etc. This is useful when documents are derived from a composition - provides guidance for how to get the latest version of the document. This is optional because this is sometimes not known by the authoring system, and can be inferred by context. However, it is important that this information be known when working with a derived document, so providing a custodian is encouraged. Reference(UK Core Organization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.custodian.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.custodian.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.custodian.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.custodian.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.custodian.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.custodian.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.custodian.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.custodian.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.custodian.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.custodian.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
relatesTo | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.relatesTo Relationships to other compositions/documents DefinitionRelationships that this composition has with other compositions or documents that already exist. A document is a version specific composition.
| |
code | 1..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.relatesTo.code replaces | transforms | signs | appends DefinitionThe type of relationship that this composition has with anther composition or document. If this document appends another document, then the document cannot be fully understood without also accessing the referenced document. The type of relationship between documents. DocumentRelationshipType (required)Constraints
| |
target[x] | 1..1 | There are no (further) constraints on this element Element IdComposition.relatesTo.target[x] Target of the relationship DefinitionThe target composition/document of this relationship.
| ||
targetIdentifier | Identifier | Data Type | ||
targetReference | Reference(UK Core Composition) | Data Type | ||
event | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.event The clinical service(s) being documented DefinitionThe clinical service, such as a colonoscopy or an appendectomy, being documented. Provides context for the composition and creates a linkage between a resource describing an event and the composition created describing the event. The event needs to be consistent with the type element, though can provide further information if desired.
|
code | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdComposition.event.code Code(s) that apply to the event being documented DefinitionThis list of codes represents the main clinical acts, such as a colonoscopy or an appendectomy, being documented. In some cases, the event is inherent in the typeCode, such as a "History and Physical Report" in which the procedure being documented is necessarily a "History and Physical" act. An event can further specialize the act inherent in the typeCode, such as where it is simply "Procedure Report" and the procedure was a "colonoscopy". If one or more eventCodes are included, they SHALL NOT conflict with the values inherent in the classCode, practiceSettingCode or typeCode, as such a conflict would create an ambiguous situation. This short list of codes is provided to be used as key words for certain types of queries. This list of codes represents the main clinical acts being documented. v3.ActCode (example)Constraints
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.event.period The period covered by the documentation DefinitionThe period of time covered by the documentation. There is no assertion that the documentation is a complete representation for this period, only that it documents events during this time. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
detail | Σ I | 0..* | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.event.detail The event(s) being documented DefinitionThe description and/or reference of the event(s) being documented. For example, this could be used to document such a colonoscopy or an appendectomy. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.event.detail.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.event.detail.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.event.detail.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.event.detail.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.event.detail.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.event.detail.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
section | I | 0..* | BackboneElement | There are no (further) constraints on this element Element IdComposition.section Composition is broken into sections DefinitionThe root of the sections that make up the composition.
|
title | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.title Label for section (e.g. for ToC) Alternate namesheader, label, caption DefinitionThe label for this particular section. This will be part of the rendered content for the document, and is often used to build a table of contents. Section headings are often standardized for different types of documents. They give guidance to humans on how the document is organized. The title identifies the section for a human reader. The title must be consistent with the narrative of the resource that is the target of the section.content reference. Generally, sections SHOULD have titles, but in some documents, it is unnecessary or inappropriate. Typically, this is where a section has subsections that have their own adequately distinguishing title, or documents that only have a single section. Most Implementation Guides will make section title to be a required element.
| |
code | 0..1 | CodeableConceptBinding | Element IdComposition.section.code Classification of section (recommended) DefinitionA code identifying the kind of content contained within the section. This must be consistent with the section title. Provides computable standardized labels to topics within the document. The code identifies the section for an automated processor of the document. This is particularly relevant when using profiles to control the structure of the document. If the section has content (instead of sub-sections), the section.code does not change the meaning or interpretation of the resource that is the content of the section in the comments for the section.code. Classification of a section of a composition/document. UKCoreCompositionSectionCode (extensible)Constraints
| |
author | I | 0..* | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) | Element IdComposition.section.author Who and/or what authored the section DefinitionIdentifies who is responsible for the information in this section, not necessarily who typed it in. Identifies who is responsible for the content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.author.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.section.author.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.section.author.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.author.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.author.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.section.author.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.author.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.section.author.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.section.author.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.author.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
focus | I | 0..1 | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.section.focus Who/what the section is about, when it is not about the subject of composition DefinitionThe actual focus of the section when it is not the subject of the composition, but instead represents something or someone associated with the subject such as (for a patient subject) a spouse, parent, fetus, or donor. If not focus is specified, the focus is assumed to be focus of the parent section, or, for a section in the Composition itself, the subject of the composition. Sections with a focus SHALL only include resources where the logical subject (patient, subject, focus, etc.) matches the section focus, or the resources have no logical subject (few resources). Typically, sections in a doument are about the subject of the document, whether that is a patient, or group of patients, location, or device, or whatever. For some kind of documents, some sections actually contain data about related entities. Typical examples are a section in a newborn discharge summary concerning the mother, or family history documents, with a section about each family member, though there are many other examples.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.focus.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.section.focus.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.section.focus.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.section.focus.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.section.focus.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.focus.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
text | I | 0..1 | Narrative | There are no (further) constraints on this element Element IdComposition.section.text Text summary of the section, for human interpretation DefinitionA human-readable narrative that contains the attested content of the section, used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Document profiles may define what content should be represented in the narrative to ensure clinical safety.
|
mode | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.mode working | snapshot | changes DefinitionHow the entry list was prepared - whether it is a working list that is suitable for being maintained on an ongoing basis, or if it represents a snapshot of a list of items from another source, or whether it is a prepared list where items may be marked as added, modified or deleted. Sections are used in various ways, and it must be known in what way it is safe to use the entries in them. This element is labeled as a modifier because a change list must not be misunderstood as a complete list. The processing mode that applies to this section. ListMode (required)Constraints
| |
orderedBy | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.orderedBy Order of section entries DefinitionSpecifies the order applied to the items in the section entries. Important for presentation and rendering. Lists may be sorted to place more important information first or to group related entries. Applications SHOULD render ordered lists in the order provided, but MAY allow users to re-order based on their own preferences as well. If there is no order specified, the order is unknown, though there may still be some order. What order applies to the items in the entry. ListOrderCodes (preferred)Constraints
| |
entry | I | 0..* | Reference(Resource) | There are no (further) constraints on this element Element IdComposition.section.entry A reference to data that supports this section DefinitionA reference to the actual resource from which the narrative in the section is derived. If there are no entries in the list, an emptyReason SHOULD be provided.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.entry.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdComposition.section.entry.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdComposition.section.entry.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdComposition.section.entry.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | Element IdComposition.section.entry.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdComposition.section.entry.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
emptyReason | I | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdComposition.section.emptyReason Why the section is empty DefinitionIf the section is empty, why the list is empty. An empty section typically has some text explaining the empty reason. Allows capturing things like "none exist" or "not asked" which can be important for most lists. The various reasons for an empty section make a significant interpretation to its interpretation. Note that this code is for use when the entire section content has been suppressed, and not for when individual items are omitted - implementers may consider using a text note or a flag on an entry in these cases. If a section is empty, why it is empty. ListEmptyReasons (preferred)Constraints
|
section | I | 0..* | see (section) | There are no (further) constraints on this element Element IdComposition.section.section Nested Section DefinitionA nested sub-section within this section. Nested sections are primarily used to help human readers navigate to particular portions of the document.
|
Composition | .. | |
Composition.extension | 0.. | |
Composition.extension | Extension | 0..1 |
Composition.identifier | .. | |
Composition.identifier.assigner | Reference(UK Core Organization) | .. |
Composition.type | .. | |
Composition.category | .. | |
Composition.subject | .. | |
Composition.subject.identifier | .. | |
Composition.subject.identifier.assigner | Reference(UK Core Organization) | .. |
Composition.encounter | Reference(UK Core Encounter) | .. |
Composition.encounter.identifier | .. | |
Composition.encounter.identifier.assigner | Reference(UK Core Organization) | .. |
Composition.author | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) | .. |
Composition.author.identifier | .. | |
Composition.author.identifier.assigner | Reference(UK Core Organization) | .. |
Composition.attester | .. | |
Composition.attester.party | Reference(UK Core Patient | UK Core RelatedPerson | UK Core Practitioner | UK Core PractitionerRole | UK Core Organization) | .. |
Composition.attester.party.identifier | .. | |
Composition.attester.party.identifier.assigner | Reference(UK Core Organization) | .. |
Composition.custodian | Reference(UK Core Organization) | .. |
Composition.custodian.identifier | .. | |
Composition.custodian.identifier.assigner | Reference(UK Core Organization) | .. |
Composition.relatesTo | .. | |
Composition.relatesTo.target[x] | Identifier, Reference(UK Core Composition) | .. |
Composition.event | .. | |
Composition.event.detail | .. | |
Composition.event.detail.identifier | .. | |
Composition.event.detail.identifier.assigner | Reference(UK Core Organization) | .. |
Composition.section | .. | |
Composition.section.code | .. | |
Composition.section.author | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Patient | UK Core RelatedPerson | UK Core Organization | UK Core Device) | .. |
Composition.section.author.identifier | .. | |
Composition.section.author.identifier.assigner | Reference(UK Core Organization) | .. |
Composition.section.focus | .. | |
Composition.section.focus.identifier | .. | |
Composition.section.focus.identifier.assigner | Reference(UK Core Organization) | .. |
Composition.section.entry | .. | |
Composition.section.entry.identifier | .. | |
Composition.section.entry.identifier.assigner | Reference(UK Core Organization) | .. |
<StructureDefinition xmlns="http://hl7.org/fhir"> <id value="UKCore-Composition" /> <url value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Composition" /> <version value="2.3.0" /> <name value="UKCoreComposition" /> <title value="UK Core Composition" /> <status value="active" /> <date value="2022-12-16" /> <publisher value="HL7 UK" /> <contact> <name value="HL7 UK" /> <telecom> <system value="email" /> <value value="ukcore@hl7.org.uk" /> <use value="work" /> <rank value="1" /> </telecom> </contact> <description value="This profile defines the UK constraints and extensions on the International FHIR resource [Composition](https://hl7.org/fhir/R4/Composition.html)." /> <purpose value="This profile allows a record of a set of healthcare-related information that is assembled together into a single logical package that provides a single coherent statement of meaning, establishes its own context and that has clinical attestation with regard to who is making the statement. \n\nA Composition defines the structure and narrative content necessary for a document. However, a Composition alone does not constitute a document. Rather, the Composition SHALL be the first entry in a Bundle where `Bundle.type=document`, and any other resources referenced from Composition SHALL be included as subsequent entries in the Bundle, for example Patient, Practitioner, Encounter, etc." /> <copyright value="Copyright © 2021+ HL7 UK Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except in compliance with the License. You may obtain a copy of the License at http://www.apache.org/licenses/LICENSE-2.0 Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License for the specific language governing permissions and limitations under the License. HL7® FHIR® standard Copyright © 2011+ HL7 The HL7® FHIR® standard is used under the FHIR license. You may obtain a copy of the FHIR license at https://www.hl7.org/fhir/license.html." /> <fhirVersion value="4.0.1" /> <mapping> <identity value="workflow" /> <uri value="http://hl7.org/fhir/workflow" /> <name value="Workflow Pattern" /> </mapping> <mapping> <identity value="rim" /> <uri value="http://hl7.org/v3" /> <name value="RIM Mapping" /> </mapping> <mapping> <identity value="cda" /> <uri value="http://hl7.org/v3/cda" /> <name value="CDA (R2)" /> </mapping> <mapping> <identity value="fhirdocumentreference" /> <uri value="http://hl7.org/fhir/documentreference" /> <name value="FHIR DocumentReference" /> </mapping> <mapping> <identity value="w5" /> <uri value="http://hl7.org/fhir/fivews" /> <name value="FiveWs Pattern Mapping" /> </mapping> <kind value="resource" /> <abstract value="false" /> <type value="Composition" /> <baseDefinition value="http://hl7.org/fhir/StructureDefinition/Composition" /> <derivation value="constraint" /> <differential> <element id="Composition"> <path value="Composition" /> <definition value="A set of healthcare-related information that is assembled together into a single logical package that provides a single coherent statement of meaning, establishes its own context and that has clinical attestation with regard to who is making the statement. A Composition defines the structure and narrative content necessary for a document. However, a Composition alone does not constitute a document. Rather, the Composition SHALL be the first entry in a Bundle where Bundle.type=document, and any other resources referenced from Composition SHALL be included as subsequent entries in the Bundle, for example Patient, Practitioner, Encounter, etc." /> </element> <element id="Composition.extension"> <path value="Composition.extension" /> <slicing> <discriminator> <type value="value" /> <path value="url" /> </discriminator> <rules value="open" /> </slicing> <min value="0" /> </element> <element id="Composition.extension:careSettingType"> <path value="Composition.extension" /> <sliceName value="careSettingType" /> <min value="0" /> <max value="1" /> <type> <code value="Extension" /> <profile value="https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CareSettingType" /> </type> </element> <element id="Composition.identifier.assigner"> <path value="Composition.identifier.assigner" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.type"> <path value="Composition.type" /> <short value="Kind of composition (SNOMED CT)" /> <binding> <strength value="preferred" /> <description value="SNOMED CT Document Type" /> <valueSet value="https://fhir.hl7.org.uk/ValueSet/UKCore-DocumentType" /> </binding> </element> <element id="Composition.category"> <path value="Composition.category" /> <definition value="A categorization for the type of the composition - helps for indexing and searching. This may be implied by or derived from the code specified in the Composition Type.\nFurther investgation is required about the usage of this element for UK Core." /> <binding> <strength value="preferred" /> <description value="A ValueSet to identify the category of a composition." /> <valueSet value="https://fhir.hl7.org.uk/ValueSet/UKCore-CompositionCategory" /> </binding> </element> <element id="Composition.subject.identifier.assigner"> <path value="Composition.subject.identifier.assigner" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.encounter"> <path value="Composition.encounter" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Encounter" /> </type> </element> <element id="Composition.encounter.identifier.assigner"> <path value="Composition.encounter.identifier.assigner" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.author"> <path value="Composition.author" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Practitioner" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-PractitionerRole" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Patient" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-RelatedPerson" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Device" /> </type> </element> <element id="Composition.author.identifier.assigner"> <path value="Composition.author.identifier.assigner" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.attester.party"> <path value="Composition.attester.party" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Patient" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-RelatedPerson" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Practitioner" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-PractitionerRole" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.attester.party.identifier.assigner"> <path value="Composition.attester.party.identifier.assigner" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.custodian"> <path value="Composition.custodian" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.custodian.identifier.assigner"> <path value="Composition.custodian.identifier.assigner" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.relatesTo.target[x]"> <path value="Composition.relatesTo.target[x]" /> <type> <code value="Identifier" /> </type> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Composition" /> </type> </element> <element id="Composition.event.detail.identifier.assigner"> <path value="Composition.event.detail.identifier.assigner" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.section.code"> <path value="Composition.section.code" /> <binding> <strength value="extensible" /> <valueSet value="https://fhir.hl7.org.uk/ValueSet/UKCore-CompositionSectionCode" /> </binding> </element> <element id="Composition.section.author"> <path value="Composition.section.author" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Practitioner" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-PractitionerRole" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Patient" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-RelatedPerson" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Device" /> </type> </element> <element id="Composition.section.author.identifier.assigner"> <path value="Composition.section.author.identifier.assigner" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.section.focus.identifier.assigner"> <path value="Composition.section.focus.identifier.assigner" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> <element id="Composition.section.entry.identifier.assigner"> <path value="Composition.section.entry.identifier.assigner" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" /> </type> </element> </differential> </StructureDefinition>
{ "resourceType": "StructureDefinition", "id": "UKCore-Composition", "url": "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Composition", "version": "2.3.0", "name": "UKCoreComposition", "title": "UK Core Composition", "status": "active", "date": "2022-12-16", "publisher": "HL7 UK", "contact": [ { "name": "HL7 UK", "telecom": [ { "system": "email", "value": "ukcore@hl7.org.uk", "use": "work", "rank": 1 } ] } ], "description": "This profile defines the UK constraints and extensions on the International FHIR resource [Composition](https://hl7.org/fhir/R4/Composition.html).", "purpose": "This profile allows a record of a set of healthcare-related information that is assembled together into a single logical package that provides a single coherent statement of meaning, establishes its own context and that has clinical attestation with regard to who is making the statement. \n\nA Composition defines the structure and narrative content necessary for a document. However, a Composition alone does not constitute a document. Rather, the Composition SHALL be the first entry in a Bundle where `Bundle.type=document`, and any other resources referenced from Composition SHALL be included as subsequent entries in the Bundle, for example Patient, Practitioner, Encounter, etc.", "copyright": "Copyright © 2021+ HL7 UK Licensed under the Apache License, Version 2.0 (the \"License\"); you may not use this file except in compliance with the License. You may obtain a copy of the License at http://www.apache.org/licenses/LICENSE-2.0 Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an \"AS IS\" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License for the specific language governing permissions and limitations under the License. HL7® FHIR® standard Copyright © 2011+ HL7 The HL7® FHIR® standard is used under the FHIR license. You may obtain a copy of the FHIR license at https://www.hl7.org/fhir/license.html.", "fhirVersion": "4.0.1", "mapping": [ { "identity": "workflow", "uri": "http://hl7.org/fhir/workflow", "name": "Workflow Pattern" }, { "identity": "rim", "uri": "http://hl7.org/v3", "name": "RIM Mapping" }, { "identity": "cda", "uri": "http://hl7.org/v3/cda", "name": "CDA (R2)" }, { "identity": "fhirdocumentreference", "uri": "http://hl7.org/fhir/documentreference", "name": "FHIR DocumentReference" }, { "identity": "w5", "uri": "http://hl7.org/fhir/fivews", "name": "FiveWs Pattern Mapping" } ], "kind": "resource", "abstract": false, "type": "Composition", "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Composition", "derivation": "constraint", "differential": { "element": [ { "id": "Composition", "path": "Composition", "definition": "A set of healthcare-related information that is assembled together into a single logical package that provides a single coherent statement of meaning, establishes its own context and that has clinical attestation with regard to who is making the statement. A Composition defines the structure and narrative content necessary for a document. However, a Composition alone does not constitute a document. Rather, the Composition SHALL be the first entry in a Bundle where Bundle.type=document, and any other resources referenced from Composition SHALL be included as subsequent entries in the Bundle, for example Patient, Practitioner, Encounter, etc." }, { "id": "Composition.extension", "path": "Composition.extension", "slicing": { "discriminator": [ { "type": "value", "path": "url" } ], "rules": "open" }, "min": 0 }, { "id": "Composition.extension:careSettingType", "path": "Composition.extension", "sliceName": "careSettingType", "min": 0, "max": "1", "type": [ { "code": "Extension", "profile": [ "https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CareSettingType" ] } ] }, { "id": "Composition.identifier.assigner", "path": "Composition.identifier.assigner", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.type", "path": "Composition.type", "short": "Kind of composition (SNOMED CT)", "binding": { "strength": "preferred", "description": "SNOMED CT Document Type", "valueSet": "https://fhir.hl7.org.uk/ValueSet/UKCore-DocumentType" } }, { "id": "Composition.category", "path": "Composition.category", "definition": "A categorization for the type of the composition - helps for indexing and searching. This may be implied by or derived from the code specified in the Composition Type.\nFurther investgation is required about the usage of this element for UK Core.", "binding": { "strength": "preferred", "description": "A ValueSet to identify the category of a composition.", "valueSet": "https://fhir.hl7.org.uk/ValueSet/UKCore-CompositionCategory" } }, { "id": "Composition.subject.identifier.assigner", "path": "Composition.subject.identifier.assigner", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.encounter", "path": "Composition.encounter", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Encounter" ] } ] }, { "id": "Composition.encounter.identifier.assigner", "path": "Composition.encounter.identifier.assigner", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.author", "path": "Composition.author", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Practitioner", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-PractitionerRole", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Patient", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-RelatedPerson", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Device" ] } ] }, { "id": "Composition.author.identifier.assigner", "path": "Composition.author.identifier.assigner", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.attester.party", "path": "Composition.attester.party", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Patient", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-RelatedPerson", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Practitioner", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-PractitionerRole", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.attester.party.identifier.assigner", "path": "Composition.attester.party.identifier.assigner", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.custodian", "path": "Composition.custodian", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.custodian.identifier.assigner", "path": "Composition.custodian.identifier.assigner", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.relatesTo.target[x]", "path": "Composition.relatesTo.target[x]", "type": [ { "code": "Identifier" }, { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Composition" ] } ] }, { "id": "Composition.event.detail.identifier.assigner", "path": "Composition.event.detail.identifier.assigner", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.section.code", "path": "Composition.section.code", "binding": { "strength": "extensible", "valueSet": "https://fhir.hl7.org.uk/ValueSet/UKCore-CompositionSectionCode" } }, { "id": "Composition.section.author", "path": "Composition.section.author", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Practitioner", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-PractitionerRole", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Patient", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-RelatedPerson", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization", "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Device" ] } ] }, { "id": "Composition.section.author.identifier.assigner", "path": "Composition.section.author.identifier.assigner", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.section.focus.identifier.assigner", "path": "Composition.section.focus.identifier.assigner", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] }, { "id": "Composition.section.entry.identifier.assigner", "path": "Composition.section.entry.identifier.assigner", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.hl7.org.uk/StructureDefinition/UKCore-Organization" ] } ] } ] } }
The following are example usage scenarios for the UK Core Composition profile:
More information about the extensions can be found using the links below.
Extension | Context | Link |
---|---|---|
careSettingType | Composition | Extension UKCore-CareSettingType |
More information about the bindings to UK Core ValueSets can be found below.
Context | Strength | Link |
---|---|---|
Composition.extension:careSettingType | Preferred | ValueSet UKCore-CareSettingType |
Composition.type | Preferred | ValueSet UKCore-DocumentType |
Composition.category | Preferred | ValueSet UKCore-CompositionCategory |
Composition.section.code | Extensible | ValueSet UKCore-CompositionSectionCode |
subject
Where a UK Core profile exists the resource being referenced SHOULD conform to the profile.
author
The resource being referenced SHOULD conform to one of the following:
title
This element SHALL be present and MAY be derived from the Composition.type
and Composition.extension:caresettingtype
.
attester
Composition.attester.party
The resource being referenced SHOULD conform to one of the following: