Device Settings codes

ValueSet 'DeviceSettingsCodes'

Published byF. Hoffmann-La Roche AG
StatusActive
ExperimentalFalse

A ValueSet containing codes for configurable device settings in the Device.property element.

This value set includes codes from the following code systems:

{
    "resourceType": "ValueSet",
    "id": "device-settings-codes",
    "url": "https://roche.com/fhir/iop/ValueSet/device-settings-codes",
    "name": "DeviceSettingsCodes",
    "description": "A ValueSet containing codes for configurable device settings in the `Device.property` element.",
    "status": "active",
    "experimental": false,
    "publisher": "F. Hoffmann-La Roche AG",
    "copyright": "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
    "compose": {
        "include":  [
            {
                "system": "http://snomed.info/sct",
                "concept":  [
                    {
                        "code": "789483009",
                        "display": "Insulin sensitivity factor"
                    },
                    {
                        "code": "789496005",
                        "display": "Insulin to carbohydrate ratio"
                    }
                ]
            },
            {
                "system": "https://roche.com/fhir/iop/cs",
                "concept":  [
                    {
                        "code": "385524004_bloodglucose",
                        "display": "Lower limit of reference range is about Capillary blood glucose measurement"
                    },
                    {
                        "code": "371933006_bloodglucose",
                        "display": "Upper limit of reference range is about Capillary blood glucose measurement"
                    },
                    {
                        "code": "1055210001_bloodglucose",
                        "display": "1055210001_bloodglucose"
                    },
                    {
                        "code": "39869006_hypoglycemia",
                        "display": "39869006_hypoglycemia"
                    },
                    {
                        "code": "39869006_hyperglycemia",
                        "display": "39869006_hyperglycemia"
                    }
                ]
            }
        ]
    }
}
<ValueSet xmlns="http://hl7.org/fhir">
    <id value="device-settings-codes" />
    <url value="https://roche.com/fhir/iop/ValueSet/device-settings-codes" />
    <name value="DeviceSettingsCodes" />
    <status value="active" />
    <experimental value="false" />
    <publisher value="F. Hoffmann-La Roche AG" />
    <description value="A ValueSet containing codes for configurable device settings in the `Device.property` element." />
    <copyright value="Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise." />
    <compose>
        <include>
            <system value="http://snomed.info/sct" />
            <concept>
                <code value="789483009" />
                <display value="Insulin sensitivity factor" />
            </concept>
            <concept>
                <code value="789496005" />
                <display value="Insulin to carbohydrate ratio" />
            </concept>
        </include>
        <include>
            <system value="https://roche.com/fhir/iop/cs" />
            <concept>
                <code value="385524004_bloodglucose" />
                <display value="Lower limit of reference range is about Capillary blood glucose measurement" />
            </concept>
            <concept>
                <code value="371933006_bloodglucose" />
                <display value="Upper limit of reference range is about Capillary blood glucose measurement" />
            </concept>
            <concept>
                <code value="1055210001_bloodglucose" />
                <display value="1055210001_bloodglucose" />
            </concept>
            <concept>
                <code value="39869006_hypoglycemia" />
                <display value="39869006_hypoglycemia" />
            </concept>
            <concept>
                <code value="39869006_hyperglycemia" />
                <display value="39869006_hyperglycemia" />
            </concept>
        </include>
    </compose>
</ValueSet>