SDS-Device
Conformance url |
---|
https://fhir.nhs.uk/StructureDefinition/SDS-Device |
with Device
Device | I | Device | There are no (further) constraints on this element Element IdDevice Item used in healthcare DefinitionA type of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device.
| |
extension | I | 0..* | Extension | Element IdDevice.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Constraints
|
managingOrganisation | S I | 1..1 | Extension(Reference()) | Element IdDevice.extension:managingOrganisation Managing or manufacturing organisation providing an Accredited System Alternate namesextensions, user content DefinitionODS reference that represents the managing or manufacturing organisation providing an Accredited System Reference to the managing, manufacturing or supplying organisation of an Accredited System. https://fhir.nhs.uk/StructureDefinition/Extension-SDS-ManagingOrganisation Constraints
|
identifier | S | 0..* | Identifier | Element IdDevice.identifier Instance identifier DefinitionUnique instance identifiers assigned to a device by manufacturers other organizations or owners. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used. Unordered, Open, by system(Value) Constraints
|
NhsSpineASID | S | 1..1 | Identifier | Element IdDevice.identifier:NhsSpineASID NHS Spine Accredited System Identifier DefinitionUnique instance identifiers assigned to a device by manufacturers other organizations or owners. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsSpineASID.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsSpineASID.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdDevice.identifier:NhsSpineASID.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/nhsSpineASID
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDevice.identifier:NhsSpineASID.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDevice.identifier:NhsSpineASID.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element IdDevice.identifier:NhsSpineASID.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization.
|
NhsMhsPartyKey | S | 1..1 | Identifier | Element IdDevice.identifier:NhsMhsPartyKey Nhs Mhs Party Key DefinitionUnique instance identifiers assigned to a device by manufacturers other organizations or owners. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsMhsPartyKey.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsMhsPartyKey.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdDevice.identifier:NhsMhsPartyKey.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/nhsMhsPartyKey
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDevice.identifier:NhsMhsPartyKey.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDevice.identifier:NhsMhsPartyKey.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element IdDevice.identifier:NhsMhsPartyKey.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization.
|
NhsEndpointServiceId | S | 1..1 | Identifier | Element IdDevice.identifier:NhsEndpointServiceId NHS Endpoint Service Id DefinitionUnique instance identifiers assigned to a device by manufacturers other organizations or owners. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsEndpointServiceId.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsEndpointServiceId.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdDevice.identifier:NhsEndpointServiceId.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/nhsEndpointServiceId
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDevice.identifier:NhsEndpointServiceId.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDevice.identifier:NhsEndpointServiceId.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element IdDevice.identifier:NhsEndpointServiceId.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization.
|
definition | I | 0..1 | Reference(DeviceDefinition) | There are no (further) constraints on this element Element IdDevice.definition The reference to the definition for the device DefinitionThe reference to the definition for the device. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
udiCarrier | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDevice.udiCarrier Unique Device Identifier (UDI) Barcode string DefinitionUnique device identifier (UDI) assigned to device label or package. Note that the Device may include multiple udiCarriers as it either may include just the udiCarrier for the jurisdiction it is sold, or for multiple jurisdictions it could have been sold. UDI may identify an unique instance of a device, or it may only identify the type of the device. See UDI mappings for a complete mapping of UDI parts to Device.
|
deviceIdentifier | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDevice.udiCarrier.deviceIdentifier Mandatory fixed portion of UDI Alternate namesDI DefinitionThe device identifier (DI) is a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device. Note that FHIR strings SHALL NOT exceed 1MB in size
|
issuer | 0..1 | uri | There are no (further) constraints on this element Element IdDevice.udiCarrier.issuer UDI Issuing Organization Alternate namesBarcode System DefinitionOrganization that is charged with issuing UDIs for devices. For example, the US FDA issuers include :
see http://en.wikipedia.org/wiki/Uniform_resource_identifier
| |
jurisdiction | 0..1 | uri | There are no (further) constraints on this element Element IdDevice.udiCarrier.jurisdiction Regional UDI authority DefinitionThe identity of the authoritative source for UDI generation within a jurisdiction. All UDIs are globally unique within a single namespace with the appropriate repository uri as the system. For example, UDIs of devices managed in the U.S. by the FDA, the value is http://hl7.org/fhir/NamingSystem/fda-udi. Allows a recipient of a UDI to know which database will contain the UDI-associated metadata. see http://en.wikipedia.org/wiki/Uniform_resource_identifier
| |
carrierAIDC | Σ | 0..1 | base64Binary | There are no (further) constraints on this element Element IdDevice.udiCarrier.carrierAIDC UDI Machine Readable Barcode String Alternate namesAutomatic Identification and Data Capture DefinitionThe full UDI carrier of the Automatic Identification and Data Capture (AIDC) technology representation of the barcode string as printed on the packaging of the device - e.g., a barcode or RFID. Because of limitations on character sets in XML and the need to round-trip JSON data through XML, AIDC Formats SHALL be base64 encoded. The AIDC form of UDIs should be scanned or otherwise used for the identification of the device whenever possible to minimize errors in records resulting from manual transcriptions. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label.
|
carrierHRF | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDevice.udiCarrier.carrierHRF UDI Human Readable Barcode String Alternate namesHuman Readable Form DefinitionThe full UDI carrier as the human readable form (HRF) representation of the barcode string as printed on the packaging of the device. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label.
|
entryType | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.udiCarrier.entryType barcode | rfid | manual + DefinitionA coded entry to indicate how the data was entered. Supports a way to distinguish hand entered from machine read data. Note that FHIR strings SHALL NOT exceed 1MB in size Codes to identify how UDI data was entered. UDIEntryType (required)Constraints
| |
status | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.status active | inactive | entered-in-error | unknown DefinitionStatus of the Device availability. This element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid. The availability status of the device. FHIRDeviceStatus (required)Constraints
|
statusReason | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element IdDevice.statusReason online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off DefinitionReason for the dtatus of the Device availability. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The availability status reason of the device. FHIRDeviceStatusReason (extensible)Constraints
| |
distinctIdentifier | 0..1 | string | There are no (further) constraints on this element Element IdDevice.distinctIdentifier The distinct identification string Alternate namesDistinct Identification Code (DIC) DefinitionThe distinct identification string as required by regulation for a human cell, tissue, or cellular and tissue-based product. For example, this applies to devices in the United States regulated under Code of Federal Regulation 21CFR§1271.290(c).
| |
manufacturer | 0..1 | string | There are no (further) constraints on this element Element IdDevice.manufacturer Name of device manufacturer DefinitionA name of the manufacturer. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
manufactureDate | 0..1 | dateTime | There are no (further) constraints on this element Element IdDevice.manufactureDate Date when the device was made DefinitionThe date and time when the device was manufactured.
| |
expirationDate | 0..1 | dateTime | There are no (further) constraints on this element Element IdDevice.expirationDate Date and time of expiry of this device (if applicable) DefinitionThe date and time beyond which this device is no longer valid or should not be used (if applicable).
| |
lotNumber | 0..1 | string | There are no (further) constraints on this element Element IdDevice.lotNumber Lot number of manufacture DefinitionLot number assigned by the manufacturer. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
serialNumber | 0..1 | string | There are no (further) constraints on this element Element IdDevice.serialNumber Serial number assigned by the manufacturer DefinitionThe serial number assigned by the organization when the device was manufactured. Alphanumeric Maximum 20.
| |
deviceName | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDevice.deviceName The name of the device as given by the manufacturer DefinitionThis represents the manufacturer's name of the device as provided by the device, from a UDI label, or by a person describing the Device. This typically would be used when a person provides the name(s) or when the device represents one of the names available from DeviceDefinition.
| |
name | 1..1 | string | There are no (further) constraints on this element Element IdDevice.deviceName.name The name of the device Alternate namesΣ DefinitionThe name of the device. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
type | 1..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.deviceName.type udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other DefinitionThe type of deviceName. UDILabelName | UserFriendlyName | PatientReportedName | ManufactureDeviceName | ModelName. Note that FHIR strings SHALL NOT exceed 1MB in size The type of name the device is referred by. DeviceNameType (required)Constraints
| |
modelNumber | 0..1 | string | There are no (further) constraints on this element Element IdDevice.modelNumber The model number for the device DefinitionThe model number for the device. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
partNumber | 0..1 | string | There are no (further) constraints on this element Element IdDevice.partNumber The part number of the device DefinitionThe part number of the device. Alphanumeric Maximum 20.
| |
type | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdDevice.type The kind or type of device DefinitionThe kind or type of device. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Codes to identify medical devices. DeviceType (example)Constraints
| |
specialization | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDevice.specialization The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication DefinitionThe capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication.
| |
systemType | 1..1 | CodeableConcept | There are no (further) constraints on this element Element IdDevice.specialization.systemType The standard that is used to operate and communicate Alternate namesΣ DefinitionThe standard that is used to operate and communicate. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
version | 0..1 | string | There are no (further) constraints on this element Element IdDevice.specialization.version The version of the standard that is used to operate and communicate DefinitionThe version of the standard that is used to operate and communicate. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
version | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDevice.version The actual design of the device or software version running on the device DefinitionThe actual design of the device or software version running on the device.
| |
type | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdDevice.version.type The type of the device version Alternate namesΣ DefinitionThe type of the device version. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
component | 0..1 | Identifier | There are no (further) constraints on this element Element IdDevice.version.component A single component of the device version DefinitionA single component of the device version.
| |
value | 1..1 | string | There are no (further) constraints on this element Element IdDevice.version.value The version text DefinitionThe version text. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
property | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDevice.property The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties DefinitionThe actual configuration settings of a device as it actually operates, e.g., regulation status, time properties.
| |
type | 1..1 | CodeableConcept | There are no (further) constraints on this element Element IdDevice.property.type Code that specifies the property DeviceDefinitionPropetyCode (Extensible) DefinitionCode that specifies the property DeviceDefinitionPropetyCode (Extensible). Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
valueQuantity | I | 0..* | Quantity | There are no (further) constraints on this element Element IdDevice.property.valueQuantity Property value as a quantity DefinitionProperty value as a quantity. The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.
|
valueCode | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdDevice.property.valueCode Property value as a code, e.g., NTP4 (synced to NTP) DefinitionProperty value as a code, e.g., NTP4 (synced to NTP). Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
patient | I | 0..1 | Reference(Patient) | There are no (further) constraints on this element Element IdDevice.patient Patient to whom Device is affixed DefinitionPatient information, If the device is affixed to a person. If the device is implanted in a patient, then need to associate the device to the patient. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
owner | S I | 1..1 | Reference(Organization) | There are no (further) constraints on this element Element IdDevice.owner Organization responsible for device DefinitionAn organization that is responsible for the provision and ongoing maintenance of the device. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
contact | I | 0..* | ContactPoint | There are no (further) constraints on this element Element IdDevice.contact Details for human/organization for support DefinitionContact details for an organization or a particular human that is responsible for the device. used for troubleshooting etc.
|
location | I | 0..1 | Reference(Location) | There are no (further) constraints on this element Element IdDevice.location Where the device is found DefinitionThe place where the device can be found. Device.location can be used to track device location. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
url | 0..1 | uri | There are no (further) constraints on this element Element IdDevice.url Network address to contact device DefinitionA network address on which the device may be contacted directly. If the device is running a FHIR server, the network address should be the Base URL from which a conformance statement may be retrieved.
| |
note | 0..* | Annotation | There are no (further) constraints on this element Element IdDevice.note Device notes and comments DefinitionDescriptive information, usage information or implantation information that is not captured in an existing element. For systems that do not have structured annotations, they can simply communicate a single annotation with no author or time. This element may need to be included in narrative because of the potential for modifying information. Annotations SHOULD NOT be used to communicate "modifying" information that could be computable. (This is a SHOULD because enforcing user behavior is nearly impossible).
| |
safety | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdDevice.safety Safety Characteristics of Device DefinitionProvides additional safety characteristics about a medical device. For example devices containing latex. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
|
parent | I | 0..1 | Reference(Device) | There are no (further) constraints on this element Element IdDevice.parent The parent device DefinitionThe parent device. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
from Device
Device | I | Device | There are no (further) constraints on this element Element IdDevice Item used in healthcare DefinitionA type of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device.
| |
extension | I | 0..* | Extension | Element IdDevice.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Constraints
|
managingOrganisation | S I | 1..1 | Extension(Reference()) | Element IdDevice.extension:managingOrganisation Managing or manufacturing organisation providing an Accredited System Alternate namesextensions, user content DefinitionODS reference that represents the managing or manufacturing organisation providing an Accredited System Reference to the managing, manufacturing or supplying organisation of an Accredited System. https://fhir.nhs.uk/StructureDefinition/Extension-SDS-ManagingOrganisation Constraints
|
identifier | S | 0..* | Identifier | Element IdDevice.identifier Instance identifier DefinitionUnique instance identifiers assigned to a device by manufacturers other organizations or owners. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used. Unordered, Open, by system(Value) Constraints
|
NhsSpineASID | S | 1..1 | Identifier | Element IdDevice.identifier:NhsSpineASID NHS Spine Accredited System Identifier DefinitionUnique instance identifiers assigned to a device by manufacturers other organizations or owners. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsSpineASID.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsSpineASID.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdDevice.identifier:NhsSpineASID.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/nhsSpineASID
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDevice.identifier:NhsSpineASID.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDevice.identifier:NhsSpineASID.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element IdDevice.identifier:NhsSpineASID.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization.
|
NhsMhsPartyKey | S | 1..1 | Identifier | Element IdDevice.identifier:NhsMhsPartyKey Nhs Mhs Party Key DefinitionUnique instance identifiers assigned to a device by manufacturers other organizations or owners. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsMhsPartyKey.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsMhsPartyKey.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdDevice.identifier:NhsMhsPartyKey.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/nhsMhsPartyKey
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDevice.identifier:NhsMhsPartyKey.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDevice.identifier:NhsMhsPartyKey.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element IdDevice.identifier:NhsMhsPartyKey.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization.
|
NhsEndpointServiceId | S | 1..1 | Identifier | Element IdDevice.identifier:NhsEndpointServiceId NHS Endpoint Service Id DefinitionUnique instance identifiers assigned to a device by manufacturers other organizations or owners. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsEndpointServiceId.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDevice.identifier:NhsEndpointServiceId.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdDevice.identifier:NhsEndpointServiceId.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/nhsEndpointServiceId
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDevice.identifier:NhsEndpointServiceId.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDevice.identifier:NhsEndpointServiceId.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element IdDevice.identifier:NhsEndpointServiceId.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization.
|
definition | I | 0..1 | Reference(DeviceDefinition) | There are no (further) constraints on this element Element IdDevice.definition The reference to the definition for the device DefinitionThe reference to the definition for the device. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
udiCarrier | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDevice.udiCarrier Unique Device Identifier (UDI) Barcode string DefinitionUnique device identifier (UDI) assigned to device label or package. Note that the Device may include multiple udiCarriers as it either may include just the udiCarrier for the jurisdiction it is sold, or for multiple jurisdictions it could have been sold. UDI may identify an unique instance of a device, or it may only identify the type of the device. See UDI mappings for a complete mapping of UDI parts to Device.
|
deviceIdentifier | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDevice.udiCarrier.deviceIdentifier Mandatory fixed portion of UDI Alternate namesDI DefinitionThe device identifier (DI) is a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device. Note that FHIR strings SHALL NOT exceed 1MB in size
|
issuer | 0..1 | uri | There are no (further) constraints on this element Element IdDevice.udiCarrier.issuer UDI Issuing Organization Alternate namesBarcode System DefinitionOrganization that is charged with issuing UDIs for devices. For example, the US FDA issuers include :
see http://en.wikipedia.org/wiki/Uniform_resource_identifier
| |
jurisdiction | 0..1 | uri | There are no (further) constraints on this element Element IdDevice.udiCarrier.jurisdiction Regional UDI authority DefinitionThe identity of the authoritative source for UDI generation within a jurisdiction. All UDIs are globally unique within a single namespace with the appropriate repository uri as the system. For example, UDIs of devices managed in the U.S. by the FDA, the value is http://hl7.org/fhir/NamingSystem/fda-udi. Allows a recipient of a UDI to know which database will contain the UDI-associated metadata. see http://en.wikipedia.org/wiki/Uniform_resource_identifier
| |
carrierAIDC | Σ | 0..1 | base64Binary | There are no (further) constraints on this element Element IdDevice.udiCarrier.carrierAIDC UDI Machine Readable Barcode String Alternate namesAutomatic Identification and Data Capture DefinitionThe full UDI carrier of the Automatic Identification and Data Capture (AIDC) technology representation of the barcode string as printed on the packaging of the device - e.g., a barcode or RFID. Because of limitations on character sets in XML and the need to round-trip JSON data through XML, AIDC Formats SHALL be base64 encoded. The AIDC form of UDIs should be scanned or otherwise used for the identification of the device whenever possible to minimize errors in records resulting from manual transcriptions. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label.
|
carrierHRF | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDevice.udiCarrier.carrierHRF UDI Human Readable Barcode String Alternate namesHuman Readable Form DefinitionThe full UDI carrier as the human readable form (HRF) representation of the barcode string as printed on the packaging of the device. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label.
|
entryType | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.udiCarrier.entryType barcode | rfid | manual + DefinitionA coded entry to indicate how the data was entered. Supports a way to distinguish hand entered from machine read data. Note that FHIR strings SHALL NOT exceed 1MB in size Codes to identify how UDI data was entered. UDIEntryType (required)Constraints
| |
status | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.status active | inactive | entered-in-error | unknown DefinitionStatus of the Device availability. This element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid. The availability status of the device. FHIRDeviceStatus (required)Constraints
|
statusReason | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element IdDevice.statusReason online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off DefinitionReason for the dtatus of the Device availability. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The availability status reason of the device. FHIRDeviceStatusReason (extensible)Constraints
| |
distinctIdentifier | 0..1 | string | There are no (further) constraints on this element Element IdDevice.distinctIdentifier The distinct identification string Alternate namesDistinct Identification Code (DIC) DefinitionThe distinct identification string as required by regulation for a human cell, tissue, or cellular and tissue-based product. For example, this applies to devices in the United States regulated under Code of Federal Regulation 21CFR§1271.290(c).
| |
manufacturer | 0..1 | string | There are no (further) constraints on this element Element IdDevice.manufacturer Name of device manufacturer DefinitionA name of the manufacturer. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
manufactureDate | 0..1 | dateTime | There are no (further) constraints on this element Element IdDevice.manufactureDate Date when the device was made DefinitionThe date and time when the device was manufactured.
| |
expirationDate | 0..1 | dateTime | There are no (further) constraints on this element Element IdDevice.expirationDate Date and time of expiry of this device (if applicable) DefinitionThe date and time beyond which this device is no longer valid or should not be used (if applicable).
| |
lotNumber | 0..1 | string | There are no (further) constraints on this element Element IdDevice.lotNumber Lot number of manufacture DefinitionLot number assigned by the manufacturer. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
serialNumber | 0..1 | string | There are no (further) constraints on this element Element IdDevice.serialNumber Serial number assigned by the manufacturer DefinitionThe serial number assigned by the organization when the device was manufactured. Alphanumeric Maximum 20.
| |
deviceName | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDevice.deviceName The name of the device as given by the manufacturer DefinitionThis represents the manufacturer's name of the device as provided by the device, from a UDI label, or by a person describing the Device. This typically would be used when a person provides the name(s) or when the device represents one of the names available from DeviceDefinition.
| |
name | 1..1 | string | There are no (further) constraints on this element Element IdDevice.deviceName.name The name of the device Alternate namesΣ DefinitionThe name of the device. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
type | 1..1 | codeBinding | There are no (further) constraints on this element Element IdDevice.deviceName.type udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other DefinitionThe type of deviceName. UDILabelName | UserFriendlyName | PatientReportedName | ManufactureDeviceName | ModelName. Note that FHIR strings SHALL NOT exceed 1MB in size The type of name the device is referred by. DeviceNameType (required)Constraints
| |
modelNumber | 0..1 | string | There are no (further) constraints on this element Element IdDevice.modelNumber The model number for the device DefinitionThe model number for the device. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
partNumber | 0..1 | string | There are no (further) constraints on this element Element IdDevice.partNumber The part number of the device DefinitionThe part number of the device. Alphanumeric Maximum 20.
| |
type | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdDevice.type The kind or type of device DefinitionThe kind or type of device. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Codes to identify medical devices. DeviceType (example)Constraints
| |
specialization | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDevice.specialization The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication DefinitionThe capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication.
| |
systemType | 1..1 | CodeableConcept | There are no (further) constraints on this element Element IdDevice.specialization.systemType The standard that is used to operate and communicate Alternate namesΣ DefinitionThe standard that is used to operate and communicate. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
version | 0..1 | string | There are no (further) constraints on this element Element IdDevice.specialization.version The version of the standard that is used to operate and communicate DefinitionThe version of the standard that is used to operate and communicate. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
version | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDevice.version The actual design of the device or software version running on the device DefinitionThe actual design of the device or software version running on the device.
| |
type | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdDevice.version.type The type of the device version Alternate namesΣ DefinitionThe type of the device version. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
component | 0..1 | Identifier | There are no (further) constraints on this element Element IdDevice.version.component A single component of the device version DefinitionA single component of the device version.
| |
value | 1..1 | string | There are no (further) constraints on this element Element IdDevice.version.value The version text DefinitionThe version text. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
property | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDevice.property The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties DefinitionThe actual configuration settings of a device as it actually operates, e.g., regulation status, time properties.
| |
type | 1..1 | CodeableConcept | There are no (further) constraints on this element Element IdDevice.property.type Code that specifies the property DeviceDefinitionPropetyCode (Extensible) DefinitionCode that specifies the property DeviceDefinitionPropetyCode (Extensible). Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
valueQuantity | I | 0..* | Quantity | There are no (further) constraints on this element Element IdDevice.property.valueQuantity Property value as a quantity DefinitionProperty value as a quantity. The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.
|
valueCode | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdDevice.property.valueCode Property value as a code, e.g., NTP4 (synced to NTP) DefinitionProperty value as a code, e.g., NTP4 (synced to NTP). Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
patient | I | 0..1 | Reference(Patient) | There are no (further) constraints on this element Element IdDevice.patient Patient to whom Device is affixed DefinitionPatient information, If the device is affixed to a person. If the device is implanted in a patient, then need to associate the device to the patient. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
owner | S I | 1..1 | Reference(Organization) | There are no (further) constraints on this element Element IdDevice.owner Organization responsible for device DefinitionAn organization that is responsible for the provision and ongoing maintenance of the device. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
contact | I | 0..* | ContactPoint | There are no (further) constraints on this element Element IdDevice.contact Details for human/organization for support DefinitionContact details for an organization or a particular human that is responsible for the device. used for troubleshooting etc.
|
location | I | 0..1 | Reference(Location) | There are no (further) constraints on this element Element IdDevice.location Where the device is found DefinitionThe place where the device can be found. Device.location can be used to track device location. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
url | 0..1 | uri | There are no (further) constraints on this element Element IdDevice.url Network address to contact device DefinitionA network address on which the device may be contacted directly. If the device is running a FHIR server, the network address should be the Base URL from which a conformance statement may be retrieved.
| |
note | 0..* | Annotation | There are no (further) constraints on this element Element IdDevice.note Device notes and comments DefinitionDescriptive information, usage information or implantation information that is not captured in an existing element. For systems that do not have structured annotations, they can simply communicate a single annotation with no author or time. This element may need to be included in narrative because of the potential for modifying information. Annotations SHOULD NOT be used to communicate "modifying" information that could be computable. (This is a SHOULD because enforcing user behavior is nearly impossible).
| |
safety | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdDevice.safety Safety Characteristics of Device DefinitionProvides additional safety characteristics about a medical device. For example devices containing latex. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
|
parent | I | 0..1 | Reference(Device) | There are no (further) constraints on this element Element IdDevice.parent The parent device DefinitionThe parent device. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|