NHSDigital-HealthcareService
Conformance url | FHIR Module | Maturity Level |
---|---|---|
https://fhir.nhs.uk/StructureDefinition/NHSDigital-HealthcareService | Administration | trial-use |
The HealthcareService resource is used to describe a single healthcare service or category of services that are provided by an organization at a location. The location of the services could be virtual, as with telemedicine services.
HealthcareService | I | HealthcareService | There are no (further) constraints on this element Element IdHealthcareService The details of a healthcare service available at a location DefinitionThe details of a healthcare service available at a location.
| |
identifier | S Σ | 0..* | Identifier | Element IdHealthcareService.identifier External identifiers for this item DefinitionSHOULD contain the service identifier e.g. the serviceId from Directory of Service or e-RS Directory Services MAY contain an ANANA/ODS code.
MUST contain an ANANA/ODS code. Unordered, Open, by system(Value) Constraints
|
(All Slices) | There are no (further) constraints on this element | |||
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdHealthcareService.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
ersServiceId | S Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId External identifiers for this item DefinitionExternal identifiers for this item.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | Element IdHealthcareService.identifier:ersServiceId.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/ers-service
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
dosServiceId | S Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId External identifiers for this item DefinitionExternal identifiers for this item.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | Element IdHealthcareService.identifier:dosServiceId.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
http://fhir.nhs.uk/Id/dos-service-id
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
active | Σ ?! | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.active Whether this HealthcareService record is in active use DefinitionThis flag is used to mark the record to not be used. This is not used when a center is closed for maintenance, or for holidays, the notAvailable period is to be used for this. This element is labeled as a modifier because it may be used to mark that the resource was created in error. This resource is generally assumed to be active if no value is provided for the active element
|
providedBy | S Σ I | 0..1 | Reference(NHSDigitalOrganization) | Element IdHealthcareService.providedBy Organization that provides this service DefinitionIt is recommended an identifier reference using ODS code is used.
This property is recommended to be the same as the Location's managingOrganization, and if not provided should be interpreted as such. If the Location does not have a managing Organization, then this property should be populated. Reference(NHSDigitalOrganization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.providedBy.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.providedBy.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 1..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | Element IdHealthcareService.providedBy.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/ods-organization-code
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.providedBy.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
category | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.category Broad category of service being performed or delivered Alternate namesservice category DefinitionIdentifies the broad category of service being performed or delivered. Selecting a Service Category then determines the list of relevant service types that can be selected in the primary service type. A category of the service(s) that could be provided. ServiceCategory (example)Constraints
|
type | S Σ | 0..* | CodeableConceptBinding | Element IdHealthcareService.type Type of service that may be delivered or performed Alternate namesservice type DefinitionType SHOULD be populated.
or
Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Additional details about where the content was created (e.g. clinical specialty). ServiceType (preferred)Constraints
|
coding | Σ | 0..* | Coding | Element IdHealthcareService.type.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
UKCoreCareSettingType | S Σ | 0..* | CodingBinding | Element IdHealthcareService.type.coding:UKCoreCareSettingType Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. UKCoreCareSettingType (preferred) Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.type.coding:UKCoreCareSettingType.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.type.coding:UKCoreCareSettingType.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.type.coding:UKCoreCareSettingType.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.type.coding:UKCoreCareSettingType.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.type.coding:UKCoreCareSettingType.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
eRSAppointmentType | S Σ | 0..* | Coding | Element IdHealthcareService.type.coding:eRSAppointmentType e-RS Appointment Type DefinitionAppointment type e.g. telephone/video (only applicable and mandatory if Service Type is Appointment Request, not applicable to Service Type of Triage Request) Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.type.coding:eRSAppointmentType.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://fhir.nhs.uk/CodeSystem/eRS-AppointmentType
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.type.coding:eRSAppointmentType.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.type.coding:eRSAppointmentType.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.type.coding:eRSAppointmentType.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.type.coding:eRSAppointmentType.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.type.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
specialty | S Σ | 0..* | CodeableConceptBinding | Element IdHealthcareService.specialty Specialties handled by the HealthcareService DefinitionSpecialty SHOULD be from the {{link:http://hl7.org/fhir/ValueSet/c80-practice-codes}} and is the SNOMED equivalent of the NHS Data Dictionary - Main Specialty and Treament Function Codes and FHIR {{pagelink: NHSDataDictionaryClinicalSpecialty.md}}
or using NHS Data Dictionary codes.
or for e-RS Patient Care
Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. A specialty that a healthcare service may provide. UKCorePracticeSettingCode (extensible)Constraints
|
coding | Σ | 0..* | Coding | Element IdHealthcareService.specialty.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
(All Slices) | There are no (further) constraints on this element | |||
system | Σ | 1..1 | uri | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
NHSDataDictionarySpecialty | S Σ | 0..* | CodingBinding | Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. NHS Data Dictionary Specialty/Treatment Function Code NHSDataDictionaryMainClinicalSpecialty (required)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://fhir.nhs.uk/CodeSystem/NHSDataModelAndDictionary-clinical-specialty
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
SNOMEDPracticeCode | S Σ | 0..* | CodingBinding | Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Specific specialty associated with the agency. PracticeSettingCodeValueSet (preferred)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
eRSSpecialty | S Σ | 0..* | CodingBinding | Element IdHealthcareService.specialty.coding:eRSSpecialty Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Specific specialty associated with the agency. NHSDigitaleRSSpecialty (preferred)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.specialty.coding:eRSSpecialty.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://fhir.nhs.uk/CodeSystem/eRS-Specialty
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:eRSSpecialty.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:eRSSpecialty.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:eRSSpecialty.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:eRSSpecialty.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
location | S Σ I | 0..1 | Reference(NHSDigitalLocation) | Element IdHealthcareService.location Location(s) where service may be provided DefinitionReference to a location. ODS codes may be used, however this may differ from Directory of Services and so DoS addresses are preferred.
or
References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.location.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.location.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.location.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.location.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.location.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | Element IdHealthcareService.location.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/ods-site-code
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.location.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.location.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.location.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.location.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
name | S Σ | 1..1 | string | Element IdHealthcareService.name Description of service as presented to a consumer while searching DefinitionName of the clinic or service.
Note that FHIR strings SHALL NOT exceed 1MB in size
|
comment | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.comment Additional description and/or any specific issues not covered elsewhere DefinitionAny additional description of the service and/or any specific issues not covered by the other attributes, which can be displayed as further detail under the serviceName. Would expect that a user would not see this information on a search results, and it would only be available when viewing the complete details of the service.
|
extraDetails | 0..1 | markdown | There are no (further) constraints on this element Element IdHealthcareService.extraDetails Extra details about the service that can't be placed in the other fields DefinitionExtra details about the service that can't be placed in the other fields. Systems are not required to have markdown support, so the text should be readable without markdown processing. The markdown syntax is GFM - see https://github.github.com/gfm/
| |
photo | Σ I | 0..1 | Attachment | There are no (further) constraints on this element Element IdHealthcareService.photo Facilitates quick identification of the service DefinitionIf there is a photo/symbol associated with this HealthcareService, it may be included here to facilitate quick identification of the service in a list. When providing a summary view (for example with Observation.value[x]) Attachment should be represented with a brief display text such as "Signed Procedure Consent".
|
telecom | S I | 0..* | ContactPoint | Element IdHealthcareService.telecom Contacts related to the healthcare service DefinitionContact details for the clinic or service.
If this is empty, then refer to the location's contacts.
|
system | Σ I | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.telecom.system phone | fax | email | pager | url | sms | other DefinitionTelecommunications form for contact point - what communications system is required to make use of the contact. Note that FHIR strings SHALL NOT exceed 1MB in size Telecommunications form for contact point. ContactPointSystem (required)Constraints
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.telecom.value The actual contact point details DefinitionThe actual contact point details, in a form that is meaningful to the designated communication system (i.e. phone number or email address). Need to support legacy numbers that are not in a tightly controlled format. Additional text data such as phone extension numbers, or notes about use of the contact are sometimes included in the value.
|
use | Σ ?! | 1..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.telecom.use home | work | temp | old | mobile - purpose of this contact point DefinitionIdentifies the purpose for the contact point. Need to track the way a person uses this contact, so a user can choose which is appropriate for their purpose. Applications can assume that a contact is current unless it explicitly says that it is temporary or old. Use of contact point. ContactPointUse (required)Constraints
|
rank | Σ | 0..1 | positiveInt | There are no (further) constraints on this element Element IdHealthcareService.telecom.rank Specify preferred order of use (1 = highest) DefinitionSpecifies a preferred order in which to use a set of contacts. ContactPoints with lower rank values are more preferred than those with higher rank values. Note that rank does not necessarily follow the order in which the contacts are represented in the instance.
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.telecom.period Time period when the contact point was/is in use DefinitionTime period when the contact point was/is in use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
coverageArea | I | 0..* | Reference(UK Core Location) | There are no (further) constraints on this element Element IdHealthcareService.coverageArea Location(s) service is intended for/available to DefinitionThe location(s) that this service is available to (not where the service is provided). The locations referenced by the coverage area can include both specific locations, including areas, and also conceptual domains too (mode = kind), such as a physical area (tri-state area) and some other attribute (covered by Example Care Organization). These types of Locations are often not managed by any specific organization. This could also include generic locations such as "in-home".
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
serviceProvisionCode | S | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode Conditions under which service is available/offered DefinitionThe code(s) that detail the conditions under which the healthcare service is available/offered. The provision means being commissioned by, contractually obliged or financially sourced. Types of costings that may apply to this healthcare service, such if the service may be available for free, some discounts available, or fees apply. The code(s) that detail the conditions under which the healthcare service is available/offered. ServiceProvisionConditions (example)Constraints
|
coding | Σ | 0..* | Coding | Element IdHealthcareService.serviceProvisionCode.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
eRSClinicType | S Σ | 0..* | CodingBinding | Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://fhir.nhs.uk/CodeSystem/NHSDigital-ClinicType
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
eligibility | 0..* | BackboneElement | There are no (further) constraints on this element Element IdHealthcareService.eligibility Specific eligibility requirements required to use the service DefinitionDoes this service have specific eligibility requirements that need to be met in order to use the service?
| |
code | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.eligibility.code Coded value for the eligibility DefinitionCoded value for the eligibility. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Coded values underwhich a specific service is made available. (unbound) (example)Constraints
| |
comment | 0..1 | markdown | There are no (further) constraints on this element Element IdHealthcareService.eligibility.comment Describes the eligibility conditions for the service DefinitionDescribes the eligibility conditions for the service. The description of service eligibility should, in general, not exceed one or two paragraphs. It should be sufficient for a prospective consumer to determine if they are likely to be eligible or not. Where eligibility requirements and conditions are complex, it may simply be noted that an eligibility assessment is required. Where eligibility is determined by an outside source, such as an Act of Parliament, this should be noted, preferably with a reference to a commonly available copy of the source document such as a web page.
| |
program | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.program Programs that this service is applicable to DefinitionPrograms that this service is applicable to. Programs are often defined externally to an Organization, commonly by governments; e.g. Home and Community Care Programs, Homeless Program, …. Government or local programs that this service applies to. Program (example)Constraints
| |
characteristic | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.characteristic Collection of characteristics (attributes) DefinitionCollection of characteristics (attributes). These could be such things as is wheelchair accessible. A custom attribute that could be provided at a service (e.g. Wheelchair accessibiliy). (unbound) (example)Constraints
| |
communication | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.communication The language that this service is offered in DefinitionSome services are specifically made available in multiple languages, this property permits a directory to declare the languages this is offered in. Typically this is only provided where a service operates in communities with mixed languages used. When using this property it indicates that the service is available with this language, it is not derived from the practitioners, and not all are required to use this language, just that this language is available while scheduling. A ValueSet that identifies the language used by a person. UKCoreHumanLanguage (extensible)Constraints
| |
referralMethod | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.referralMethod Ways that the service accepts referrals DefinitionWays that the service accepts referrals, if this is not provided then it is implied that no referral is required. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The methods of referral can be used when referring to a specific HealthCareService resource. ReferralMethod (example)Constraints
| |
appointmentRequired | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.appointmentRequired If an appointment is required for access to this service DefinitionIndicates whether or not a prospective consumer will require an appointment for a particular service at a site to be provided by the Organization. Indicates if an appointment is required for access to this service.
| |
availableTime | S | 0..* | BackboneElement | Element IdHealthcareService.availableTime Times the Service Site is available DefinitionOpening times for the clinic or service.
More detailed availability information may be provided in associated Schedule/Slot resources.
|
daysOfWeek | 0..* | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.availableTime.daysOfWeek mon | tue | wed | thu | fri | sat | sun DefinitionIndicates which days of the week are available between the start and end Times. Note that FHIR strings SHALL NOT exceed 1MB in size The days of the week. DaysOfWeek (required)Constraints
| |
allDay | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.availableTime.allDay Always available? e.g. 24 hour service DefinitionIs this always available? (hence times are irrelevant) e.g. 24 hour service.
| |
availableStartTime | 0..1 | time | There are no (further) constraints on this element Element IdHealthcareService.availableTime.availableStartTime Opening time of day (ignored if allDay = true) DefinitionThe opening time of day. Note: If the AllDay flag is set, then this time is ignored. The time zone is expected to be for where this HealthcareService is provided at.
| |
availableEndTime | 0..1 | time | There are no (further) constraints on this element Element IdHealthcareService.availableTime.availableEndTime Closing time of day (ignored if allDay = true) DefinitionThe closing time of day. Note: If the AllDay flag is set, then this time is ignored. The time zone is expected to be for where this HealthcareService is provided at.
| |
notAvailable | 0..* | BackboneElement | There are no (further) constraints on this element Element IdHealthcareService.notAvailable Not available during this time due to provided reason DefinitionThe HealthcareService is not available during this period of time due to the provided reason.
| |
description | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.notAvailable.description Reason presented to the user explaining why time not available DefinitionThe reason that can be presented to the user as to why this time is not available. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
during | I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.notAvailable.during Service not available from this date DefinitionService is not available (seasonally or for a public holiday) from this date. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
availabilityExceptions | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.availabilityExceptions Description of availability exceptions DefinitionA description of site availability exceptions, e.g. public holiday availability. Succinctly describing all possible exceptions to normal site availability as details in the available Times and not available Times. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
endpoint | S I | 0..* | Reference(Endpoint) | Element IdHealthcareService.endpoint Technical endpoints providing access to electronic services operated for the healthcare service DefinitionTechnical endpoints providing access to services operated for the specific healthcare services defined at this resource. Endpoint identfiers to be used with the HealthcareService. Endpoints can be resolved using the SDS API
References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Unordered, Open, by identifier.system(Value) Constraints
|
(All Slices) | There are no (further) constraints on this element | |||
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 1..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 1..1 | uri | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
nhsMhsPartyKey | I | 0..1 | Reference(Endpoint) | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey Technical endpoints providing access to electronic services operated for the healthcare service DefinitionTechnical endpoints providing access to services operated for the specific healthcare services defined at this resource. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/nhsMhsPartyKey
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
nhsSpineASID | I | 0..1 | Reference(Endpoint) | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID Technical endpoints providing access to electronic services operated for the healthcare service DefinitionTechnical endpoints providing access to services operated for the specific healthcare services defined at this resource. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.endpoint:nhsSpineASID.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/nhsSpineASID
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
HealthcareService | I | HealthcareService | There are no (further) constraints on this element Element IdHealthcareService The details of a healthcare service available at a location DefinitionThe details of a healthcare service available at a location.
| |
identifier | S Σ | 0..* | Identifier | Element IdHealthcareService.identifier External identifiers for this item DefinitionSHOULD contain the service identifier e.g. the serviceId from Directory of Service or e-RS Directory Services MAY contain an ANANA/ODS code.
MUST contain an ANANA/ODS code. Unordered, Open, by system(Value) Constraints
|
(All Slices) | There are no (further) constraints on this element | |||
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdHealthcareService.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
ersServiceId | S Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId External identifiers for this item DefinitionExternal identifiers for this item.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | Element IdHealthcareService.identifier:ersServiceId.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/ers-service
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.identifier:ersServiceId.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
dosServiceId | S Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId External identifiers for this item DefinitionExternal identifiers for this item.
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | Element IdHealthcareService.identifier:dosServiceId.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
http://fhir.nhs.uk/Id/dos-service-id
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.identifier:dosServiceId.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
active | Σ ?! | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.active Whether this HealthcareService record is in active use DefinitionThis flag is used to mark the record to not be used. This is not used when a center is closed for maintenance, or for holidays, the notAvailable period is to be used for this. This element is labeled as a modifier because it may be used to mark that the resource was created in error. This resource is generally assumed to be active if no value is provided for the active element
|
providedBy | S Σ I | 0..1 | Reference(NHSDigitalOrganization) | Element IdHealthcareService.providedBy Organization that provides this service DefinitionIt is recommended an identifier reference using ODS code is used.
This property is recommended to be the same as the Location's managingOrganization, and if not provided should be interpreted as such. If the Location does not have a managing Organization, then this property should be populated. Reference(NHSDigitalOrganization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.providedBy.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.providedBy.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 1..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | Element IdHealthcareService.providedBy.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/ods-organization-code
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.providedBy.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.providedBy.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
category | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.category Broad category of service being performed or delivered Alternate namesservice category DefinitionIdentifies the broad category of service being performed or delivered. Selecting a Service Category then determines the list of relevant service types that can be selected in the primary service type. A category of the service(s) that could be provided. ServiceCategory (example)Constraints
|
type | S Σ | 0..* | CodeableConceptBinding | Element IdHealthcareService.type Type of service that may be delivered or performed Alternate namesservice type DefinitionType SHOULD be populated.
or
Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Additional details about where the content was created (e.g. clinical specialty). ServiceType (preferred)Constraints
|
coding | Σ | 0..* | Coding | Element IdHealthcareService.type.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
UKCoreCareSettingType | S Σ | 0..* | CodingBinding | Element IdHealthcareService.type.coding:UKCoreCareSettingType Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. UKCoreCareSettingType (preferred) Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.type.coding:UKCoreCareSettingType.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.type.coding:UKCoreCareSettingType.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.type.coding:UKCoreCareSettingType.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.type.coding:UKCoreCareSettingType.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.type.coding:UKCoreCareSettingType.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
eRSAppointmentType | S Σ | 0..* | Coding | Element IdHealthcareService.type.coding:eRSAppointmentType e-RS Appointment Type DefinitionAppointment type e.g. telephone/video (only applicable and mandatory if Service Type is Appointment Request, not applicable to Service Type of Triage Request) Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.type.coding:eRSAppointmentType.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://fhir.nhs.uk/CodeSystem/eRS-AppointmentType
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.type.coding:eRSAppointmentType.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.type.coding:eRSAppointmentType.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.type.coding:eRSAppointmentType.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.type.coding:eRSAppointmentType.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.type.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
specialty | S Σ | 0..* | CodeableConceptBinding | Element IdHealthcareService.specialty Specialties handled by the HealthcareService DefinitionSpecialty SHOULD be from the {{link:http://hl7.org/fhir/ValueSet/c80-practice-codes}} and is the SNOMED equivalent of the NHS Data Dictionary - Main Specialty and Treament Function Codes and FHIR {{pagelink: NHSDataDictionaryClinicalSpecialty.md}}
or using NHS Data Dictionary codes.
or for e-RS Patient Care
Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. A specialty that a healthcare service may provide. UKCorePracticeSettingCode (extensible)Constraints
|
coding | Σ | 0..* | Coding | Element IdHealthcareService.specialty.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
(All Slices) | There are no (further) constraints on this element | |||
system | Σ | 1..1 | uri | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
NHSDataDictionarySpecialty | S Σ | 0..* | CodingBinding | Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. NHS Data Dictionary Specialty/Treatment Function Code NHSDataDictionaryMainClinicalSpecialty (required)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://fhir.nhs.uk/CodeSystem/NHSDataModelAndDictionary-clinical-specialty
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:NHSDataDictionarySpecialty.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
SNOMEDPracticeCode | S Σ | 0..* | CodingBinding | Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Specific specialty associated with the agency. PracticeSettingCodeValueSet (preferred)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:SNOMEDPracticeCode.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
eRSSpecialty | S Σ | 0..* | CodingBinding | Element IdHealthcareService.specialty.coding:eRSSpecialty Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Specific specialty associated with the agency. NHSDigitaleRSSpecialty (preferred)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.specialty.coding:eRSSpecialty.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://fhir.nhs.uk/CodeSystem/eRS-Specialty
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:eRSSpecialty.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:eRSSpecialty.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:eRSSpecialty.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.specialty.coding:eRSSpecialty.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.specialty.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
location | S Σ I | 0..1 | Reference(NHSDigitalLocation) | Element IdHealthcareService.location Location(s) where service may be provided DefinitionReference to a location. ODS codes may be used, however this may differ from Directory of Services and so DoS addresses are preferred.
or
References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.location.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.location.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.location.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.location.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.location.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | Element IdHealthcareService.location.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/ods-site-code
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.location.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.location.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.location.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.location.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
name | S Σ | 1..1 | string | Element IdHealthcareService.name Description of service as presented to a consumer while searching DefinitionName of the clinic or service.
Note that FHIR strings SHALL NOT exceed 1MB in size
|
comment | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.comment Additional description and/or any specific issues not covered elsewhere DefinitionAny additional description of the service and/or any specific issues not covered by the other attributes, which can be displayed as further detail under the serviceName. Would expect that a user would not see this information on a search results, and it would only be available when viewing the complete details of the service.
|
extraDetails | 0..1 | markdown | There are no (further) constraints on this element Element IdHealthcareService.extraDetails Extra details about the service that can't be placed in the other fields DefinitionExtra details about the service that can't be placed in the other fields. Systems are not required to have markdown support, so the text should be readable without markdown processing. The markdown syntax is GFM - see https://github.github.com/gfm/
| |
photo | Σ I | 0..1 | Attachment | There are no (further) constraints on this element Element IdHealthcareService.photo Facilitates quick identification of the service DefinitionIf there is a photo/symbol associated with this HealthcareService, it may be included here to facilitate quick identification of the service in a list. When providing a summary view (for example with Observation.value[x]) Attachment should be represented with a brief display text such as "Signed Procedure Consent".
|
telecom | S I | 0..* | ContactPoint | Element IdHealthcareService.telecom Contacts related to the healthcare service DefinitionContact details for the clinic or service.
If this is empty, then refer to the location's contacts.
|
system | Σ I | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.telecom.system phone | fax | email | pager | url | sms | other DefinitionTelecommunications form for contact point - what communications system is required to make use of the contact. Note that FHIR strings SHALL NOT exceed 1MB in size Telecommunications form for contact point. ContactPointSystem (required)Constraints
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.telecom.value The actual contact point details DefinitionThe actual contact point details, in a form that is meaningful to the designated communication system (i.e. phone number or email address). Need to support legacy numbers that are not in a tightly controlled format. Additional text data such as phone extension numbers, or notes about use of the contact are sometimes included in the value.
|
use | Σ ?! | 1..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.telecom.use home | work | temp | old | mobile - purpose of this contact point DefinitionIdentifies the purpose for the contact point. Need to track the way a person uses this contact, so a user can choose which is appropriate for their purpose. Applications can assume that a contact is current unless it explicitly says that it is temporary or old. Use of contact point. ContactPointUse (required)Constraints
|
rank | Σ | 0..1 | positiveInt | There are no (further) constraints on this element Element IdHealthcareService.telecom.rank Specify preferred order of use (1 = highest) DefinitionSpecifies a preferred order in which to use a set of contacts. ContactPoints with lower rank values are more preferred than those with higher rank values. Note that rank does not necessarily follow the order in which the contacts are represented in the instance.
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.telecom.period Time period when the contact point was/is in use DefinitionTime period when the contact point was/is in use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
coverageArea | I | 0..* | Reference(UK Core Location) | There are no (further) constraints on this element Element IdHealthcareService.coverageArea Location(s) service is intended for/available to DefinitionThe location(s) that this service is available to (not where the service is provided). The locations referenced by the coverage area can include both specific locations, including areas, and also conceptual domains too (mode = kind), such as a physical area (tri-state area) and some other attribute (covered by Example Care Organization). These types of Locations are often not managed by any specific organization. This could also include generic locations such as "in-home".
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.coverageArea.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
serviceProvisionCode | S | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode Conditions under which service is available/offered DefinitionThe code(s) that detail the conditions under which the healthcare service is available/offered. The provision means being commissioned by, contractually obliged or financially sourced. Types of costings that may apply to this healthcare service, such if the service may be available for free, some discounts available, or fees apply. The code(s) that detail the conditions under which the healthcare service is available/offered. ServiceProvisionConditions (example)Constraints
|
coding | Σ | 0..* | Coding | Element IdHealthcareService.serviceProvisionCode.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
eRSClinicType | S Σ | 0..* | CodingBinding | Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://fhir.nhs.uk/CodeSystem/NHSDigital-ClinicType
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 0..1 | code | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode.coding:eRSClinicType.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.serviceProvisionCode.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
eligibility | 0..* | BackboneElement | There are no (further) constraints on this element Element IdHealthcareService.eligibility Specific eligibility requirements required to use the service DefinitionDoes this service have specific eligibility requirements that need to be met in order to use the service?
| |
code | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.eligibility.code Coded value for the eligibility DefinitionCoded value for the eligibility. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Coded values underwhich a specific service is made available. (unbound) (example)Constraints
| |
comment | 0..1 | markdown | There are no (further) constraints on this element Element IdHealthcareService.eligibility.comment Describes the eligibility conditions for the service DefinitionDescribes the eligibility conditions for the service. The description of service eligibility should, in general, not exceed one or two paragraphs. It should be sufficient for a prospective consumer to determine if they are likely to be eligible or not. Where eligibility requirements and conditions are complex, it may simply be noted that an eligibility assessment is required. Where eligibility is determined by an outside source, such as an Act of Parliament, this should be noted, preferably with a reference to a commonly available copy of the source document such as a web page.
| |
program | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.program Programs that this service is applicable to DefinitionPrograms that this service is applicable to. Programs are often defined externally to an Organization, commonly by governments; e.g. Home and Community Care Programs, Homeless Program, …. Government or local programs that this service applies to. Program (example)Constraints
| |
characteristic | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.characteristic Collection of characteristics (attributes) DefinitionCollection of characteristics (attributes). These could be such things as is wheelchair accessible. A custom attribute that could be provided at a service (e.g. Wheelchair accessibiliy). (unbound) (example)Constraints
| |
communication | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.communication The language that this service is offered in DefinitionSome services are specifically made available in multiple languages, this property permits a directory to declare the languages this is offered in. Typically this is only provided where a service operates in communities with mixed languages used. When using this property it indicates that the service is available with this language, it is not derived from the practitioners, and not all are required to use this language, just that this language is available while scheduling. A ValueSet that identifies the language used by a person. UKCoreHumanLanguage (extensible)Constraints
| |
referralMethod | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdHealthcareService.referralMethod Ways that the service accepts referrals DefinitionWays that the service accepts referrals, if this is not provided then it is implied that no referral is required. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The methods of referral can be used when referring to a specific HealthCareService resource. ReferralMethod (example)Constraints
| |
appointmentRequired | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.appointmentRequired If an appointment is required for access to this service DefinitionIndicates whether or not a prospective consumer will require an appointment for a particular service at a site to be provided by the Organization. Indicates if an appointment is required for access to this service.
| |
availableTime | S | 0..* | BackboneElement | Element IdHealthcareService.availableTime Times the Service Site is available DefinitionOpening times for the clinic or service.
More detailed availability information may be provided in associated Schedule/Slot resources.
|
daysOfWeek | 0..* | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.availableTime.daysOfWeek mon | tue | wed | thu | fri | sat | sun DefinitionIndicates which days of the week are available between the start and end Times. Note that FHIR strings SHALL NOT exceed 1MB in size The days of the week. DaysOfWeek (required)Constraints
| |
allDay | 0..1 | boolean | There are no (further) constraints on this element Element IdHealthcareService.availableTime.allDay Always available? e.g. 24 hour service DefinitionIs this always available? (hence times are irrelevant) e.g. 24 hour service.
| |
availableStartTime | 0..1 | time | There are no (further) constraints on this element Element IdHealthcareService.availableTime.availableStartTime Opening time of day (ignored if allDay = true) DefinitionThe opening time of day. Note: If the AllDay flag is set, then this time is ignored. The time zone is expected to be for where this HealthcareService is provided at.
| |
availableEndTime | 0..1 | time | There are no (further) constraints on this element Element IdHealthcareService.availableTime.availableEndTime Closing time of day (ignored if allDay = true) DefinitionThe closing time of day. Note: If the AllDay flag is set, then this time is ignored. The time zone is expected to be for where this HealthcareService is provided at.
| |
notAvailable | 0..* | BackboneElement | There are no (further) constraints on this element Element IdHealthcareService.notAvailable Not available during this time due to provided reason DefinitionThe HealthcareService is not available during this period of time due to the provided reason.
| |
description | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.notAvailable.description Reason presented to the user explaining why time not available DefinitionThe reason that can be presented to the user as to why this time is not available. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
during | I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.notAvailable.during Service not available from this date DefinitionService is not available (seasonally or for a public holiday) from this date. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
availabilityExceptions | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.availabilityExceptions Description of availability exceptions DefinitionA description of site availability exceptions, e.g. public holiday availability. Succinctly describing all possible exceptions to normal site availability as details in the available Times and not available Times. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
endpoint | S I | 0..* | Reference(Endpoint) | Element IdHealthcareService.endpoint Technical endpoints providing access to electronic services operated for the healthcare service DefinitionTechnical endpoints providing access to services operated for the specific healthcare services defined at this resource. Endpoint identfiers to be used with the HealthcareService. Endpoints can be resolved using the SDS API
References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Unordered, Open, by identifier.system(Value) Constraints
|
(All Slices) | There are no (further) constraints on this element | |||
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 1..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 1..1 | uri | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.endpoint.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
nhsMhsPartyKey | I | 0..1 | Reference(Endpoint) | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey Technical endpoints providing access to electronic services operated for the healthcare service DefinitionTechnical endpoints providing access to services operated for the specific healthcare services defined at this resource. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/nhsMhsPartyKey
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsMhsPartyKey.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
nhsSpineASID | I | 0..1 | Reference(Endpoint) | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID Technical endpoints providing access to electronic services operated for the healthcare service DefinitionTechnical endpoints providing access to services operated for the specific healthcare services defined at this resource. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uriFixed Value | Element IdHealthcareService.endpoint:nhsSpineASID.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
https://fhir.nhs.uk/Id/nhsSpineASID
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdHealthcareService.endpoint:nhsSpineASID.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
key | human | severity | expression |
---|---|---|---|
nhsd-8 | location - An identifier reference or resource reference must be provided | error | (reference.exists() or identifier.exists()) |
Constraint Profiles
name | profile | purpose |
---|---|---|
ERSHealthcareService | https://fhir.nhs.uk/StructureDefinition/eRS-HealthcareService | This profile is used to describe a single healthcare service or category of services that are provided by an organization at a location, including a virtual location. |
NHSDigitalHealthcareServicePatientCare | https://fhir.nhs.uk/StructureDefinition/NHSDigital-HealthcareService-PatientCare | Profile on NHSDigital-HealthcareService for NHS App/e-RS PatientCare |
Definition
The details of a healthcare service available at a location.
- identifier
- identifier:ersServiceId
- identifier:ersServiceId.system
- identifier:dosServiceId
- identifier:dosServiceId.system
- providedBy
- providedBy.identifier.system
- type
- type.coding:UKCoreCareSettingType
- type.coding:UKCoreCareSettingType.system
- type.coding:eRSAppointmentType
- type.coding:eRSAppointmentType.system
- specialty
- specialty.coding:NHSDataDictionarySpecialty
- specialty.coding:NHSDataDictionarySpecialty.system
- specialty.coding:SNOMEDPracticeCode
- specialty.coding:SNOMEDPracticeCode.system
- specialty.coding:eRSSpecialty
- specialty.coding:eRSSpecialty.system
- location
- location.identifier.system
- name
- telecom
- serviceProvisionCode
- serviceProvisionCode.coding:eRSClinicType
- serviceProvisionCode.coding:eRSClinicType.system
- availableTime
- endpoint
- endpoint:nhsMhsPartyKey
- endpoint:nhsMhsPartyKey.identifier.system
- endpoint:nhsSpineASID
- endpoint:nhsSpineASID.identifier.system
identifier
Element Id | HealthcareService.identifier |
Cardinality | 1..* |
Slicing | OPEN discriminator - VALUE system |
type | Identifier |
Definition
SHOULD contain the service identifier e.g. the serviceId from Directory of Service or e-RS Directory Services
MAY contain an ANANA/ODS code.
"identifier": [ { "use": "official", "system": "https://fhir.nhs.uk/Id/ers-service", "value": "11021" } ]
Comment
MUST contain an ANANA/ODS code.
identifier:ersServiceId
Element Id | HealthcareService.identifier:ersServiceId |
Cardinality | 0..1 |
Slice Name | ersServiceId |
type | Identifier |
Definition
External identifiers for this item.
identifier:ersServiceId.system
Element Id | HealthcareService.identifier:ersServiceId.system |
Cardinality | 1..1 |
Fixed Value | https://fhir.nhs.uk/Id/ers-service |
type | uri |
Definition
Establishes the namespace for the value - that is, a URL that describes a set values that are unique.
Requirements
There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers.
Comment
Identifier.system is always case sensitive.
identifier:dosServiceId
Element Id | HealthcareService.identifier:dosServiceId |
Cardinality | 0..1 |
Slice Name | dosServiceId |
type | Identifier |
Definition
External identifiers for this item.
identifier:dosServiceId.system
Element Id | HealthcareService.identifier:dosServiceId.system |
Cardinality | 1..1 |
Fixed Value | http://fhir.nhs.uk/Id/dos-service-id |
type | uri |
Definition
Establishes the namespace for the value - that is, a URL that describes a set values that are unique.
Requirements
There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers.
Comment
Identifier.system is always case sensitive.
providedBy
Element Id | HealthcareService.providedBy |
Cardinality | 0..1 |
type | Reference(NHSDigitalOrganization) |
Definition
It is recommended an identifier reference using ODS code is used.
"providedBy": { "identifier": { "system": "https://fhir.nhs.uk/Id/ods-organization-code", "value": "RBA" }, "display": "TAUNTON AND SOMERSET NHS FOUNDATION TRUST" }
Comment
This property is recommended to be the same as the Location's managingOrganization, and if not provided should be interpreted as such. If the Location does not have a managing Organization, then this property should be populated.
providedBy.identifier.system
Element Id | HealthcareService.providedBy.identifier.system |
Cardinality | 1..1 |
Fixed Value | https://fhir.nhs.uk/Id/ods-organization-code |
type | uri |
Definition
Establishes the namespace for the value - that is, a URL that describes a set values that are unique.
Requirements
There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers.
Comment
Identifier.system is always case sensitive.
type
Element Id | HealthcareService.type |
Cardinality | 0..* |
Terminology Binding | ServiceType (Preferred) |
type | CodeableConcept |
Definition
Type SHOULD be populated.
"type": [ { "coding": [ { "system": "https://fhir.nhs.uk/CodeSystem/DoS-ClinicType", "code": "PHARMACY", "display": "Pharmacy" } ] } ],
or
"type": [ { "coding": [ { "system": "https://fhir.nhs.uk/CodeSystem/eRS-AppointmentType", "code": "DAY_CASE", } ] } ],
type.coding:UKCoreCareSettingType
Element Id | HealthcareService.type.coding:UKCoreCareSettingType |
Cardinality | 0..* |
Terminology Binding | UKCoreCareSettingType (Preferred) |
Slice Name | UKCoreCareSettingType |
type | Coding |
Definition
A reference to a code defined by a terminology system.
Requirements
Allows for alternative encodings within a code system, and translations to other code systems.
Comment
Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labelled as UserSelected = true.
type.coding:UKCoreCareSettingType.system
Element Id | HealthcareService.type.coding:UKCoreCareSettingType.system |
Cardinality | 0..1 |
Fixed Value | http://snomed.info/sct |
type | uri |
Definition
The identification of the code system that defines the meaning of the symbol in the code.
Requirements
Need to be unambiguous about the source of the definition of the symbol.
Comment
The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
type.coding:eRSAppointmentType
Element Id | HealthcareService.type.coding:eRSAppointmentType |
Cardinality | 0..* |
Slice Name | eRSAppointmentType |
type | Coding |
Definition
Appointment type e.g. telephone/video (only applicable and mandatory if Service Type is Appointment Request, not applicable to Service Type of Triage Request)
Requirements
Allows for alternative encodings within a code system, and translations to other code systems.
Comment
Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labelled as UserSelected = true.
type.coding:eRSAppointmentType.system
Element Id | HealthcareService.type.coding:eRSAppointmentType.system |
Cardinality | 0..1 |
Fixed Value | https://fhir.nhs.uk/CodeSystem/eRS-AppointmentType |
type | uri |
Definition
The identification of the code system that defines the meaning of the symbol in the code.
Requirements
Need to be unambiguous about the source of the definition of the symbol.
Comment
The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
specialty
Element Id | HealthcareService.specialty |
Cardinality | 0..* |
Terminology Binding | PracticeSettingCodeValueSet (Preferred) A specialty that a healthcare service may provide. |
type | CodeableConcept |
Definition
Specialty SHOULD be from the PracticeSettingCodeValueSet and is the SNOMED equivalent of the NHS Data Dictionary - Main Specialty and Treatment Function Codes and FHIR NHS Data Dictionary Clinical Specialty
"specialty": [ { "coding": [ { "system": "http://snomed.info/sct", "code": "394579002", "display": "Cardiology" } ] } ],
or using NHS Data Dictionary codes.
"specialty": [ { "coding": [ { "system": "https://fhir.nhs.uk/CodeSystem/NHSDataModelAndDictionary-clinical-specialty", "code": "320", "display": "Cardiology" } ] } ],
or for e-RS Patient Care
"specialty": [ { "coding": [ { "display": "Dermatology" } ] } ],
specialty.coding:NHSDataDictionarySpecialty
Element Id | HealthcareService.specialty.coding:NHSDataDictionarySpecialty |
Cardinality | 0..* |
Terminology Binding | NHSDataDictionaryMainClinicalSpecialty (Required) NHS Data Dictionary Specialty/Treatment Function Code |
Slice Name | NHSDataDictionarySpecialty |
type | Coding |
Definition
A reference to a code defined by a terminology system.
Requirements
Allows for alternative encodings within a code system, and translations to other code systems.
Comment
Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labelled as UserSelected = true.
specialty.coding:NHSDataDictionarySpecialty.system
Element Id | HealthcareService.specialty.coding:NHSDataDictionarySpecialty.system |
Cardinality | 0..1 |
Fixed Value | https://fhir.nhs.uk/CodeSystem/NHSDataModelAndDictionary-clinical-specialty |
type | uri |
Definition
The identification of the code system that defines the meaning of the symbol in the code.
Requirements
Need to be unambiguous about the source of the definition of the symbol.
Comment
The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
specialty.coding:SNOMEDPracticeCode
Element Id | HealthcareService.specialty.coding:SNOMEDPracticeCode |
Cardinality | 0..* |
Terminology Binding | PracticeSettingCodeValueSet (Preferred) Specific specialty associated with the agency. |
Slice Name | SNOMEDPracticeCode |
type | Coding |
Definition
A reference to a code defined by a terminology system.
Requirements
Allows for alternative encodings within a code system, and translations to other code systems.
Comment
Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labelled as UserSelected = true.
specialty.coding:SNOMEDPracticeCode.system
Element Id | HealthcareService.specialty.coding:SNOMEDPracticeCode.system |
Cardinality | 0..1 |
Fixed Value | http://snomed.info/sct |
type | uri |
Definition
The identification of the code system that defines the meaning of the symbol in the code.
Requirements
Need to be unambiguous about the source of the definition of the symbol.
Comment
The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
specialty.coding:eRSSpecialty
Element Id | HealthcareService.specialty.coding:eRSSpecialty |
Cardinality | 0..* |
Terminology Binding | NHSDigitaleRSSpecialty (Preferred) Specific specialty associated with the agency. |
Slice Name | eRSSpecialty |
type | Coding |
Definition
A reference to a code defined by a terminology system.
Requirements
Allows for alternative encodings within a code system, and translations to other code systems.
Comment
Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labelled as UserSelected = true.
specialty.coding:eRSSpecialty.system
Element Id | HealthcareService.specialty.coding:eRSSpecialty.system |
Cardinality | 0..1 |
Fixed Value | https://fhir.nhs.uk/CodeSystem/eRS-Specialty |
type | uri |
Definition
The identification of the code system that defines the meaning of the symbol in the code.
Requirements
Need to be unambiguous about the source of the definition of the symbol.
Comment
The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
location
Element Id | HealthcareService.location |
Cardinality | 0..1 |
type | Reference(NHSDigitalLocation) |
Definition
Reference to a location. ODS codes may be used, however this may differ from Directory of Services and so DoS addresses are preferred.
"location": [ { "reference": "urn:uuid:8a5d7d67-64fb-44ec-9802-2dc214bb3dcb" } ],
or
"location": [ { "identifier": { "system": "https://fhir.nhs.uk/Id/ods-site-code", "value": "R6901" } } ],
Constraints
- nhsd-8 (ERROR) location - An identifier reference or resource reference must be provided
location.identifier.system
Element Id | HealthcareService.location.identifier.system |
Cardinality | 1..1 |
Fixed Value | https://fhir.nhs.uk/Id/ods-site-code |
type | uri |
Definition
Establishes the namespace for the value - that is, a URL that describes a set values that are unique.
Requirements
There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers.
Comment
Identifier.system is always case sensitive.
name
Element Id | HealthcareService.name |
Cardinality | 1..1 |
type | string |
Definition
Name of the clinic or service.
"name": "SOMERSET BOWEL CANCER SCREENING CENTRE",
telecom
Element Id | HealthcareService.telecom |
Cardinality | 0..* |
type | ContactPoint |
Definition
Contact details for the clinic or service.
"telecom": [ { "system": "phone", "value": "0113 922 4984", "use": "work" }, { "system": "email", "value": "directaddress@example.com", "use": "work" } ],
Comment
If this is empty, then refer to the location's contacts.
serviceProvisionCode
Element Id | HealthcareService.serviceProvisionCode |
Cardinality | 0..* |
Terminology Binding | ServiceProvisionConditions (Example) The code(s) that detail the conditions under which the healthcare service is available/offered. |
type | CodeableConcept |
Definition
The code(s) that detail the conditions under which the healthcare service is available/offered.
Comment
The provision means being commissioned by, contractually obliged or financially sourced. Types of costings that may apply to this healthcare service, such if the service may be available for free, some discounts available, or fees apply.
serviceProvisionCode.coding:eRSClinicType
Element Id | HealthcareService.serviceProvisionCode.coding:eRSClinicType |
Cardinality | 0..* |
Terminology Binding | ERSClinicType (Required) |
Slice Name | eRSClinicType |
type | Coding |
Definition
A reference to a code defined by a terminology system.
Requirements
Allows for alternative encodings within a code system, and translations to other code systems.
Comment
Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labelled as UserSelected = true.
serviceProvisionCode.coding:eRSClinicType.system
Element Id | HealthcareService.serviceProvisionCode.coding:eRSClinicType.system |
Cardinality | 0..1 |
Fixed Value | https://fhir.nhs.uk/CodeSystem/NHSDigital-ClinicType |
type | uri |
Definition
The identification of the code system that defines the meaning of the symbol in the code.
Requirements
Need to be unambiguous about the source of the definition of the symbol.
Comment
The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
availableTime
Element Id | HealthcareService.availableTime |
Cardinality | 0..* |
type | BackboneElement |
Definition
Opening times for the clinic or service.
"availableTime": [ { "daysOfWeek": [ "wed" ], "allDay": true }, { "daysOfWeek": [ "mon", "tue", "wed", "thu" ], "availableStartTime": "08:30:00", "availableEndTime": "05:30:00" }, { "daysOfWeek": [ "sat", "fri" ], "availableStartTime": "09:30:00", "availableEndTime": "04:30:00" } ],
Comment
More detailed availability information may be provided in associated Schedule/Slot resources.
endpoint
Element Id | HealthcareService.endpoint |
Cardinality | 0..* |
Slicing | OPEN discriminator - VALUE identifier.system |
type | Reference(Endpoint) |
Definition
Technical endpoints providing access to services operated for the specific healthcare services defined at this resource.
Endpoint identifiers to be used with the HealthcareService. Endpoints can be resolved using the SDS API
"endpoint": [ { "identifier": { "system": "https://fhir.nhs.uk/Id/nhsSpineASID", // or https://fhir.nhs.uk/Id/nhsMhsPartyKey "value": "999900000041" } } ]
endpoint:nhsMhsPartyKey
Element Id | HealthcareService.endpoint:nhsMhsPartyKey |
Cardinality | 0..1 |
Slice Name | nhsMhsPartyKey |
type | Reference(Endpoint) |
Definition
Technical endpoints providing access to services operated for the specific healthcare services defined at this resource.
endpoint:nhsMhsPartyKey.identifier.system
Element Id | HealthcareService.endpoint:nhsMhsPartyKey.identifier.system |
Cardinality | 0..1 |
Fixed Value | https://fhir.nhs.uk/Id/nhsMhsPartyKey |
type | uri |
Definition
Establishes the namespace for the value - that is, a URL that describes a set values that are unique.
Requirements
There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers.
Comment
Identifier.system is always case sensitive.
endpoint:nhsSpineASID
Element Id | HealthcareService.endpoint:nhsSpineASID |
Cardinality | 0..1 |
Slice Name | nhsSpineASID |
type | Reference(Endpoint) |
Definition
Technical endpoints providing access to services operated for the specific healthcare services defined at this resource.
endpoint:nhsSpineASID.identifier.system
Element Id | HealthcareService.endpoint:nhsSpineASID.identifier.system |
Cardinality | 0..1 |
Fixed Value | https://fhir.nhs.uk/Id/nhsSpineASID |
type | uri |
Definition
Establishes the namespace for the value - that is, a URL that describes a set values that are unique.
Requirements
There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers.
Comment
Identifier.system is always case sensitive.