For a full list of available versions, see the Directory of published versions
Simplifier project page: ImagingStudy (Submission)
Derived from: ImagingStudy EHR
| Canonical_Url | Profile_Status | Profile_Version | FHIR_Version |
|---|---|---|---|
| http://ontariohealth.ca/fhir/mi/StructureDefinition/ca-on-mi-profile-imagingStudy | active | 1.0.0 | 4.0.1 |
The ImagingStudy resource supports the submission of MI imaging manifests.
Description of Profiles, Differentials, Snapshots and how the different presentations work
| MIImagingStudy (ImagingStudy) | C | ImagingStudy | There are no (further) constraints on this element Element idImagingStudyShort description A set of images produced in single study (one or more series of references images) DefinitionRepresentation of the content produced in a DICOM imaging study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities.
| |||
| id | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.idShort description Logical id of this artifact DefinitionThe logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. The only time that a resource does not have an id is when it is being submitted to the server using a create operation. | ||
| meta | Σ | 0..1 | Meta | There are no (further) constraints on this element Element idImagingStudy.metaShort description Metadata about the resource DefinitionThe metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| implicitRules | Σ ?! | 0..1 | uri | There are no (further) constraints on this element Element idImagingStudy.implicitRulesShort description A set of rules under which this content was created DefinitionA reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| language | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.languageShort description Language of the resource content DefinitionThe base language in which the resource is written. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). A human language.
The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| |||
| text | 0..1 | Narrative | There are no (further) constraints on this element Element idImagingStudy.textShort description Text summary of the resource, for human interpretation Alternate namesnarrative, html, xhtml, display DefinitionA human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| |||
| contained | 0..* | Resource | There are no (further) constraints on this element Element idImagingStudy.containedShort description Contained, inline Resources Alternate namesinline resources, anonymous resources, contained resources DefinitionThese resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.
| |||
| extension | S C | 1..* | Extension | There are no (further) constraints on this element Element idImagingStudy.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| imagingStudyServiceType | S C | 1..1 | Extension(Coding) | Element idImagingStudy.extension:imagingStudyServiceTypeShort description Optional Extensions Element Alternate namesextensions, user content DefinitionOptional Extension Element - found in all resources. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. https://ontariohealth.ca/fhir/mi/StructureDefinition/ca-on-mi-ext-imagingStudyServiceType ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.modifierExtensionShort description Extensions that cannot be ignored Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | S Σ | 1..* | Identifier | Element idImagingStudy.identifierShort description Identifiers for the whole study Alternate namesStudyInstanceUID, AccessionNumber DefinitionIdentifiers for the ImagingStudy such as DICOM Study Instance UID, and Accession Number. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier (see DICOM PS 3.3 C.7.2. See discussion under Imaging Study Implementation Notes for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type. Unordered, Open, by type.coding.code(Value), system(Value) must contain one repetition of an accession number. ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier-accession | S Σ | 1..1 | Identifier | Element idImagingStudy.identifier:identifier-accessionShort description Filler/Accession ID Alternate namesStudyInstanceUID, AccessionNumber DefinitionIdentifiers for the ImagingStudy such as DICOM Study Instance UID, and Accession Number. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier (see DICOM PS 3.3 C.7.2. See discussion under Imaging Study Implementation Notes for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | S Σ | 1..1 | CodeableConceptBindingFixed Value | Element idImagingStudy.identifier:identifier-accession.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0203",
"code": "ACSN",
"display": "Accession ID"
}
]
}Mappings
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| coding | S Σ | 1..1 | CodingFixed Value | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.codingShort description Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0203",
"code": "ACSN",
"display": "Accession ID"
}Mappings
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uriFixed Value | Element idImagingStudy.identifier:identifier-accession.type.coding.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
http://terminology.hl7.org/CodeSystem/v2-0203Mappings
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | codeFixed Value | Element idImagingStudy.identifier:identifier-accession.type.coding.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
ACSNMappings
| ||
| display | S Σ | 1..1 | stringFixed Value | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
Accession IDMappings
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| text | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.textShort description Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | Element idImagingStudy.identifier:identifier-accession.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. MI uses source organization specific URIs for this field. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier-studyInstanceUID | S Σ | 1..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUIDShort description Identifiers for the whole study Alternate namesStudyInstanceUID, AccessionNumber DefinitionIdentifiers for the ImagingStudy such as DICOM Study Instance UID, and Accession Number. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier (see DICOM PS 3.3 C.7.2. See discussion under Imaging Study Implementation Notes for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uriFixed Value | Element idImagingStudy.identifier:identifier-studyInstanceUID.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
urn:dicom:uidExamples General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| status | S Σ ?! | 1..1 | codeBindingFixed Value | Element idImagingStudy.statusShort description registered | available | cancelled | entered-in-error | unknown DefinitionThe current state of the ImagingStudy. Unknown does not represent "other" - one of the defined statuses must apply. Unknown is used when the authoring system is not sure what the current status is. The status of the ImagingStudy. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
availableMappings
| ||
| modality | S Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element idImagingStudy.modalityShort description All series modality if actual acquisition modalities Alternate namesModalitiesInStudy DefinitionA list of all the series.modality values that are actual acquisition modalities, i.e. those in the DICOM Context Group 29 (value set OID 1.2.840.10008.6.1.19). Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Type of acquired data in the instance. AcquisitionModality (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.modality.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.modality.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.modality.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.modality.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.modality.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.modality.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.modality.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| subject | S Σ C | 1..1 | Reference(MIPatient) | Element idImagingStudy.subjectShort description Who or what is the subject of the study DefinitionThe subject, typically a patient, of the imaging study. QA phantoms can be recorded with a Device; multiple subjects (such as mice) can be recorded with a Group. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.subject.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.subject.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.subject.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.subject.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.subject.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.subject.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| encounter | Σ C | 0..1 | Reference(Encounter) | There are no (further) constraints on this element Element idImagingStudy.encounterShort description Encounter with which this imaging study is associated DefinitionThe healthcare event (e.g. a patient and healthcare provider interaction) during which this ImagingStudy is made. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission test). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| started | S Σ | 0..1 | dateTime | There are no (further) constraints on this element Element idImagingStudy.startedShort description When the study was started Alternate namesStudyDate, StudyTime DefinitionDate and time the study started. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 2011-01-01T11:01:20+03:00Mappings
| ||
| basedOn | S Σ C | 0..* | Reference(MIServiceRequest) | Element idImagingStudy.basedOnShort description Request fulfilled DefinitionA list of the diagnostic requests that resulted in this imaging study being performed. To support grouped procedures (one imaging study supporting multiple ordered procedures, e.g. chest/abdomen/pelvis CT). References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.basedOn.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.basedOn.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | S Σ | 1..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | S Σ | 1..1 | CodeableConceptBinding | Element idImagingStudy.basedOn.identifier.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. http://ontariohealth.ca/fhir/ValueSet/identifier-type (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| referrer | S Σ C | 0..1 | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | Element idImagingStudy.referrerShort description Referring physician Alternate namesReferringPhysiciansName DefinitionThe requesting/referring physician. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(MIOrganization | MIPractitioner | MIPractitionerRole) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.referrer.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.referrer.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.referrer.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | S Σ | 1..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.referrer.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.referrer.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.referrer.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| interpreter | S Σ C | 0..* | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | Element idImagingStudy.interpreterShort description Who interpreted images Alternate namesName of Physician(s) Reading Study DefinitionWho read the study and interpreted the images or other content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(MIOrganization | MIPractitioner | MIPractitionerRole) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.interpreter.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.interpreter.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.interpreter.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | S Σ | 1..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.interpreter.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.interpreter.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.interpreter.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| endpoint | S Σ C | 0..* | Reference(EndpointEHR) | Element idImagingStudy.endpointShort description Study access endpoint DefinitionThe network service providing access (e.g., query, view, or retrieval) for the study. See implementation notes for information about using DICOM endpoints. A study-level endpoint applies to each series in the study, unless overridden by a series-level endpoint with the same Endpoint.connectionType. Access methods for viewing (e.g., IHE’s IID profile) or retrieving (e.g., DICOM’s WADO-URI and WADO-RS) the study or the study’s series or instances. The study-level baseLocation applies to each series in the study, unless overridden in series by a series-level baseLocation of the same type. Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG), formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances; or IHE Invoke Image Display (IID), which provides standard invocation of an imaging web viewer. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.endpoint.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.endpoint.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | S Σ | 1..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| numberOfSeries | S Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.numberOfSeriesShort description Number of Study Related Series Alternate namesNumberOfStudyRelatedSeries DefinitionNumber of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| numberOfInstances | S Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.numberOfInstancesShort description Number of Study Related Instances Alternate namesNumberOfStudyRelatedInstances DefinitionNumber of SOP Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| procedureReference | Σ C | 0..1 | Reference(Procedure) | There are no (further) constraints on this element Element idImagingStudy.procedureReferenceShort description The performed Procedure reference DefinitionThe procedure which this ImagingStudy was part of. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| procedureCode | S Σ | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.procedureCodeShort description The performed procedure code Alternate namesProcedureCodeSequence DefinitionThe code for the performed procedure type. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The performed procedure type. http://www.rsna.org/RadLex_Playbook.aspx (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.procedureCode.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| coding | S Σ | 1..* | Coding | There are no (further) constraints on this element Element idImagingStudy.procedureCode.codingShort description Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| text | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.textShort description Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| location | Σ C | 0..1 | Reference(Location) | There are no (further) constraints on this element Element idImagingStudy.locationShort description Where ImagingStudy occurred DefinitionThe principal physical location where the ImagingStudy was performed. Ties the event to where the records are likely kept and provides context around the event occurrence (e.g. if it occurred inside or outside a dedicated healthcare setting). References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reasonCode | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element idImagingStudy.reasonCodeShort description Why the study was requested DefinitionDescription of clinical condition indicating why the ImagingStudy was requested. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The reason for the study. ProcedureReasonCodes (example) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reasonReference | Σ C | 0..* | Reference(Condition | DiagnosticReport | DocumentReference | Media | Observation) | There are no (further) constraints on this element Element idImagingStudy.reasonReferenceShort description Why was study performed DefinitionIndicates another resource whose existence justifies this Study. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(Condition | DiagnosticReport | DocumentReference | Media | Observation) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| note | Σ | 0..* | Annotation | There are no (further) constraints on this element Element idImagingStudy.noteShort description User-defined comments DefinitionPer the recommended DICOM mapping, this element is derived from the Study Description attribute (0008,1030). Observations or findings about the imaging study should be recorded in another resource, e.g. Observation, and not in this element. For systems that do not have structured annotations, they can simply communicate a single annotation with no author or time. This element may need to be included in narrative because of the potential for modifying information. Annotations SHOULD NOT be used to communicate "modifying" information that could be computable. (This is a SHOULD because enforcing user behavior is nearly impossible). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| description | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.descriptionShort description Institution-generated description Alternate namesStudyDescription DefinitionThe Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| series | S Σ | 1..* | BackboneElement | There are no (further) constraints on this element Element idImagingStudy.seriesShort description Each study has one or more series of instances DefinitionEach study has one or more series of images or other content. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | Σ ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.modifierExtensionShort description Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| uid | S Σ | 1..1 | id | There are no (further) constraints on this element Element idImagingStudy.series.uidShort description DICOM Series Instance UID for the series Alternate namesSeriesInstanceUID DefinitionThe DICOM Series Instance UID for the series. DICOM Series Instance UID. See DICOM PS3.3 C.7.3. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 2.16.124.113543.6003.2588828330.45298.17418.2723805630Mappings
| ||
| number | Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.series.numberShort description Numeric identifier of this series Alternate namesSeriesNumber DefinitionThe numeric identifier of this series in the study. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 3Mappings
| ||
| modality | S Σ | 1..1 | CodingBinding | There are no (further) constraints on this element Element idImagingStudy.series.modalityShort description The modality of the instances in the series Alternate namesModality DefinitionThe modality of this series sequence. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Type of acquired data in the instance. AcquisitionModality (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.modality.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.modality.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.series.modality.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.modality.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.series.modality.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.modality.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.series.modality.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| description | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.descriptionShort description A short human readable summary of the series Alternate namesSeriesDescription DefinitionA description of the series. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General CT Surview 180Mappings
| ||
| numberOfInstances | S Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.series.numberOfInstancesShort description Number of Series Related Instances Alternate namesNumberOfSeriesRelatedInstances DefinitionNumber of SOP Instances in the Study. The value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| endpoint | Σ C | 0..* | Reference(Endpoint) | There are no (further) constraints on this element Element idImagingStudy.series.endpointShort description Series access endpoint DefinitionThe network service providing access (e.g., query, view, or retrieval) for this series. See implementation notes for information about using DICOM endpoints. A series-level endpoint, if present, has precedence over a study-level endpoint with the same Endpoint.connectionType. Access methods for retrieving (e.g., DICOM’s WADO-URI and WADO-RS) the series or the series’ instances. A baseLocation specified at the series level has precedence over a baseLocation of the same type specified at the study level. Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG) formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; and DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| bodySite | Σ | 0..1 | Coding | There are no (further) constraints on this element Element idImagingStudy.series.bodySiteShort description Body part examined Alternate namesBodyPartExamined DefinitionThe anatomic structures examined. See DICOM Part 16 Annex L (http://dicom.nema.org/medical/dicom/current/output/chtml/part16/chapter_L.html) for DICOM to SNOMED-CT mappings. The bodySite may indicate the laterality of body part imaged; if so, it shall be consistent with any content of ImagingStudy.series.laterality. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Codes describing anatomical locations. May include laterality. SNOMEDCTBodyStructures (example) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| laterality | Σ | 0..1 | Coding | There are no (further) constraints on this element Element idImagingStudy.series.lateralityShort description Body part laterality DefinitionThe laterality of the (possibly paired) anatomic structures examined. E.g., the left knee, both lungs, or unpaired abdomen. If present, shall be consistent with any laterality information indicated in ImagingStudy.series.bodySite. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Codes describing body site laterality (left, right, etc.). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| specimen | Σ C | 0..* | Reference(Specimen) | There are no (further) constraints on this element Element idImagingStudy.series.specimenShort description Specimen imaged DefinitionThe specimen imaged, e.g., for whole slide imaging of a biopsy. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| started | Σ | 0..1 | dateTime | There are no (further) constraints on this element Element idImagingStudy.series.startedShort description When the series started DefinitionThe date and time the series was started. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| performer | S Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element idImagingStudy.series.performerShort description Who performed the series Alternate namesPerformingPhysicianName, OperatorName DefinitionIndicates who or what performed the series and how they were involved. The performer is recorded at the series level, since each series in a study may be performed by a different performer, at different times, and using different devices. A series may be performed by multiple performers. If the person who performed the series is not known, their Organization may be recorded. A patient, or related person, may be the performer, e.g. for patient-captured images. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | Σ ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.modifierExtensionShort description Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| function | S Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.series.performer.functionShort description Type of performance DefinitionDistinguishes the type of involvement of the performer in the series. Allows disambiguation of the types of involvement of different performers. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The type of involvement of the performer. ImagingStudySeriesPerformerFunction (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| coding | S Σ | 1..* | Coding | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.codingShort description Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| text | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.textShort description Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| actor | S Σ C | 1..1 | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | Element idImagingStudy.series.performer.actorShort description Who performed the series DefinitionIndicates who or what performed the series. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(MIOrganization | MIPractitioner | MIPractitionerRole) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| instance | S | 1..* | BackboneElement | There are no (further) constraints on this element Element idImagingStudy.series.instanceShort description A single SOP instance from the series DefinitionA single SOP instance within the series, e.g. an image, or presentation state. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.instance.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | Σ ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.instance.modifierExtensionShort description Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| uid | S | 1..1 | id | There are no (further) constraints on this element Element idImagingStudy.series.instance.uidShort description DICOM SOP Instance UID Alternate namesSOPInstanceUID DefinitionThe DICOM SOP Instance UID for this image or other DICOM content. DICOM SOP Instance UID. See DICOM PS3.3 C.12.1. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 2.16.124.113543.6003.189642796.63084.16748.2599092903Mappings
| ||
| sopClass | S | 1..1 | CodingBinding | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClassShort description DICOM class type Alternate namesSOPClassUID DefinitionDICOM instance type. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. The sopClass for the instance. http://dicom.nema.org/medical/dicom/current/output/chtml/part04/sect_B.5.html#table_B.5-1 (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| number | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.series.instance.numberShort description The number of this instance in the series Alternate namesInstanceNumber DefinitionThe number of instance in the series. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 1Mappings
| |||
| title | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.titleShort description Description of instance DefinitionThe description of the instance. Particularly for post-acquisition analytic objects, such as SR, presentation states, value mapping, etc. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
|
| MIImagingStudy (ImagingStudy) | C | ImagingStudy | There are no (further) constraints on this element Element idImagingStudyShort description A set of images produced in single study (one or more series of references images) DefinitionRepresentation of the content produced in a DICOM imaging study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities.
| |||
| id | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.idShort description Logical id of this artifact DefinitionThe logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. The only time that a resource does not have an id is when it is being submitted to the server using a create operation. | ||
| meta | Σ | 0..1 | Meta | There are no (further) constraints on this element Element idImagingStudy.metaShort description Metadata about the resource DefinitionThe metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| implicitRules | Σ ?! | 0..1 | uri | There are no (further) constraints on this element Element idImagingStudy.implicitRulesShort description A set of rules under which this content was created DefinitionA reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| language | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.languageShort description Language of the resource content DefinitionThe base language in which the resource is written. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). A human language.
The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| |||
| text | 0..1 | Narrative | There are no (further) constraints on this element Element idImagingStudy.textShort description Text summary of the resource, for human interpretation Alternate namesnarrative, html, xhtml, display DefinitionA human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| |||
| contained | 0..* | Resource | There are no (further) constraints on this element Element idImagingStudy.containedShort description Contained, inline Resources Alternate namesinline resources, anonymous resources, contained resources DefinitionThese resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.
| |||
| extension | S C | 1..* | Extension | There are no (further) constraints on this element Element idImagingStudy.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| imagingStudyServiceType | S C | 1..1 | Extension(Coding) | Element idImagingStudy.extension:imagingStudyServiceTypeShort description Optional Extensions Element Alternate namesextensions, user content DefinitionOptional Extension Element - found in all resources. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. https://ontariohealth.ca/fhir/mi/StructureDefinition/ca-on-mi-ext-imagingStudyServiceType ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.modifierExtensionShort description Extensions that cannot be ignored Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | S Σ | 1..* | Identifier | Element idImagingStudy.identifierShort description Identifiers for the whole study Alternate namesStudyInstanceUID, AccessionNumber DefinitionIdentifiers for the ImagingStudy such as DICOM Study Instance UID, and Accession Number. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier (see DICOM PS 3.3 C.7.2. See discussion under Imaging Study Implementation Notes for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type. Unordered, Open, by type.coding.code(Value), system(Value) must contain one repetition of an accession number. ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier-accession | S Σ | 1..1 | Identifier | Element idImagingStudy.identifier:identifier-accessionShort description Filler/Accession ID Alternate namesStudyInstanceUID, AccessionNumber DefinitionIdentifiers for the ImagingStudy such as DICOM Study Instance UID, and Accession Number. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier (see DICOM PS 3.3 C.7.2. See discussion under Imaging Study Implementation Notes for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | S Σ | 1..1 | CodeableConceptBindingFixed Value | Element idImagingStudy.identifier:identifier-accession.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0203",
"code": "ACSN",
"display": "Accession ID"
}
]
}Mappings
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| coding | S Σ | 1..1 | CodingFixed Value | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.codingShort description Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0203",
"code": "ACSN",
"display": "Accession ID"
}Mappings
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uriFixed Value | Element idImagingStudy.identifier:identifier-accession.type.coding.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
http://terminology.hl7.org/CodeSystem/v2-0203Mappings
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | codeFixed Value | Element idImagingStudy.identifier:identifier-accession.type.coding.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
ACSNMappings
| ||
| display | S Σ | 1..1 | stringFixed Value | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
Accession IDMappings
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| text | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.textShort description Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | Element idImagingStudy.identifier:identifier-accession.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. MI uses source organization specific URIs for this field. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier-studyInstanceUID | S Σ | 1..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUIDShort description Identifiers for the whole study Alternate namesStudyInstanceUID, AccessionNumber DefinitionIdentifiers for the ImagingStudy such as DICOM Study Instance UID, and Accession Number. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier (see DICOM PS 3.3 C.7.2. See discussion under Imaging Study Implementation Notes for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uriFixed Value | Element idImagingStudy.identifier:identifier-studyInstanceUID.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
urn:dicom:uidExamples General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| status | S Σ ?! | 1..1 | codeBindingFixed Value | Element idImagingStudy.statusShort description registered | available | cancelled | entered-in-error | unknown DefinitionThe current state of the ImagingStudy. Unknown does not represent "other" - one of the defined statuses must apply. Unknown is used when the authoring system is not sure what the current status is. The status of the ImagingStudy. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
availableMappings
| ||
| modality | S Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element idImagingStudy.modalityShort description All series modality if actual acquisition modalities Alternate namesModalitiesInStudy DefinitionA list of all the series.modality values that are actual acquisition modalities, i.e. those in the DICOM Context Group 29 (value set OID 1.2.840.10008.6.1.19). Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Type of acquired data in the instance. AcquisitionModality (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.modality.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.modality.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.modality.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.modality.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.modality.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.modality.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.modality.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| subject | S Σ C | 1..1 | Reference(MIPatient) | Element idImagingStudy.subjectShort description Who or what is the subject of the study DefinitionThe subject, typically a patient, of the imaging study. QA phantoms can be recorded with a Device; multiple subjects (such as mice) can be recorded with a Group. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.subject.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.subject.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.subject.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.subject.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.subject.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.subject.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| encounter | Σ C | 0..1 | Reference(Encounter) | There are no (further) constraints on this element Element idImagingStudy.encounterShort description Encounter with which this imaging study is associated DefinitionThe healthcare event (e.g. a patient and healthcare provider interaction) during which this ImagingStudy is made. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission test). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| started | S Σ | 0..1 | dateTime | There are no (further) constraints on this element Element idImagingStudy.startedShort description When the study was started Alternate namesStudyDate, StudyTime DefinitionDate and time the study started. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 2011-01-01T11:01:20+03:00Mappings
| ||
| basedOn | S Σ C | 0..* | Reference(MIServiceRequest) | Element idImagingStudy.basedOnShort description Request fulfilled DefinitionA list of the diagnostic requests that resulted in this imaging study being performed. To support grouped procedures (one imaging study supporting multiple ordered procedures, e.g. chest/abdomen/pelvis CT). References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.basedOn.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.basedOn.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | S Σ | 1..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | S Σ | 1..1 | CodeableConceptBinding | Element idImagingStudy.basedOn.identifier.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. http://ontariohealth.ca/fhir/ValueSet/identifier-type (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| referrer | S Σ C | 0..1 | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | Element idImagingStudy.referrerShort description Referring physician Alternate namesReferringPhysiciansName DefinitionThe requesting/referring physician. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(MIOrganization | MIPractitioner | MIPractitionerRole) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.referrer.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.referrer.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.referrer.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | S Σ | 1..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.referrer.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.referrer.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.referrer.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| interpreter | S Σ C | 0..* | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | Element idImagingStudy.interpreterShort description Who interpreted images Alternate namesName of Physician(s) Reading Study DefinitionWho read the study and interpreted the images or other content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(MIOrganization | MIPractitioner | MIPractitionerRole) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.interpreter.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.interpreter.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.interpreter.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | S Σ | 1..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.interpreter.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.interpreter.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.interpreter.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| endpoint | S Σ C | 0..* | Reference(EndpointEHR) | Element idImagingStudy.endpointShort description Study access endpoint DefinitionThe network service providing access (e.g., query, view, or retrieval) for the study. See implementation notes for information about using DICOM endpoints. A study-level endpoint applies to each series in the study, unless overridden by a series-level endpoint with the same Endpoint.connectionType. Access methods for viewing (e.g., IHE’s IID profile) or retrieving (e.g., DICOM’s WADO-URI and WADO-RS) the study or the study’s series or instances. The study-level baseLocation applies to each series in the study, unless overridden in series by a series-level baseLocation of the same type. Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG), formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances; or IHE Invoke Image Display (IID), which provides standard invocation of an imaging web viewer. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.endpoint.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.endpoint.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | S Σ | 1..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| numberOfSeries | S Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.numberOfSeriesShort description Number of Study Related Series Alternate namesNumberOfStudyRelatedSeries DefinitionNumber of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| numberOfInstances | S Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.numberOfInstancesShort description Number of Study Related Instances Alternate namesNumberOfStudyRelatedInstances DefinitionNumber of SOP Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| procedureReference | Σ C | 0..1 | Reference(Procedure) | There are no (further) constraints on this element Element idImagingStudy.procedureReferenceShort description The performed Procedure reference DefinitionThe procedure which this ImagingStudy was part of. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| procedureCode | S Σ | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.procedureCodeShort description The performed procedure code Alternate namesProcedureCodeSequence DefinitionThe code for the performed procedure type. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The performed procedure type. http://www.rsna.org/RadLex_Playbook.aspx (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.procedureCode.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| coding | S Σ | 1..* | Coding | There are no (further) constraints on this element Element idImagingStudy.procedureCode.codingShort description Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| text | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.textShort description Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| location | Σ C | 0..1 | Reference(Location) | There are no (further) constraints on this element Element idImagingStudy.locationShort description Where ImagingStudy occurred DefinitionThe principal physical location where the ImagingStudy was performed. Ties the event to where the records are likely kept and provides context around the event occurrence (e.g. if it occurred inside or outside a dedicated healthcare setting). References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reasonCode | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element idImagingStudy.reasonCodeShort description Why the study was requested DefinitionDescription of clinical condition indicating why the ImagingStudy was requested. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The reason for the study. ProcedureReasonCodes (example) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reasonReference | Σ C | 0..* | Reference(Condition | DiagnosticReport | DocumentReference | Media | Observation) | There are no (further) constraints on this element Element idImagingStudy.reasonReferenceShort description Why was study performed DefinitionIndicates another resource whose existence justifies this Study. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(Condition | DiagnosticReport | DocumentReference | Media | Observation) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| note | Σ | 0..* | Annotation | There are no (further) constraints on this element Element idImagingStudy.noteShort description User-defined comments DefinitionPer the recommended DICOM mapping, this element is derived from the Study Description attribute (0008,1030). Observations or findings about the imaging study should be recorded in another resource, e.g. Observation, and not in this element. For systems that do not have structured annotations, they can simply communicate a single annotation with no author or time. This element may need to be included in narrative because of the potential for modifying information. Annotations SHOULD NOT be used to communicate "modifying" information that could be computable. (This is a SHOULD because enforcing user behavior is nearly impossible). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| description | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.descriptionShort description Institution-generated description Alternate namesStudyDescription DefinitionThe Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| series | S Σ | 1..* | BackboneElement | There are no (further) constraints on this element Element idImagingStudy.seriesShort description Each study has one or more series of instances DefinitionEach study has one or more series of images or other content. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | Σ ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.modifierExtensionShort description Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| uid | S Σ | 1..1 | id | There are no (further) constraints on this element Element idImagingStudy.series.uidShort description DICOM Series Instance UID for the series Alternate namesSeriesInstanceUID DefinitionThe DICOM Series Instance UID for the series. DICOM Series Instance UID. See DICOM PS3.3 C.7.3. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 2.16.124.113543.6003.2588828330.45298.17418.2723805630Mappings
| ||
| number | Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.series.numberShort description Numeric identifier of this series Alternate namesSeriesNumber DefinitionThe numeric identifier of this series in the study. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 3Mappings
| ||
| modality | S Σ | 1..1 | CodingBinding | There are no (further) constraints on this element Element idImagingStudy.series.modalityShort description The modality of the instances in the series Alternate namesModality DefinitionThe modality of this series sequence. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Type of acquired data in the instance. AcquisitionModality (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.modality.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.modality.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.series.modality.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.modality.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.series.modality.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.modality.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.series.modality.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| description | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.descriptionShort description A short human readable summary of the series Alternate namesSeriesDescription DefinitionA description of the series. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General CT Surview 180Mappings
| ||
| numberOfInstances | S Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.series.numberOfInstancesShort description Number of Series Related Instances Alternate namesNumberOfSeriesRelatedInstances DefinitionNumber of SOP Instances in the Study. The value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| endpoint | Σ C | 0..* | Reference(Endpoint) | There are no (further) constraints on this element Element idImagingStudy.series.endpointShort description Series access endpoint DefinitionThe network service providing access (e.g., query, view, or retrieval) for this series. See implementation notes for information about using DICOM endpoints. A series-level endpoint, if present, has precedence over a study-level endpoint with the same Endpoint.connectionType. Access methods for retrieving (e.g., DICOM’s WADO-URI and WADO-RS) the series or the series’ instances. A baseLocation specified at the series level has precedence over a baseLocation of the same type specified at the study level. Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG) formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; and DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| bodySite | Σ | 0..1 | Coding | There are no (further) constraints on this element Element idImagingStudy.series.bodySiteShort description Body part examined Alternate namesBodyPartExamined DefinitionThe anatomic structures examined. See DICOM Part 16 Annex L (http://dicom.nema.org/medical/dicom/current/output/chtml/part16/chapter_L.html) for DICOM to SNOMED-CT mappings. The bodySite may indicate the laterality of body part imaged; if so, it shall be consistent with any content of ImagingStudy.series.laterality. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Codes describing anatomical locations. May include laterality. SNOMEDCTBodyStructures (example) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| laterality | Σ | 0..1 | Coding | There are no (further) constraints on this element Element idImagingStudy.series.lateralityShort description Body part laterality DefinitionThe laterality of the (possibly paired) anatomic structures examined. E.g., the left knee, both lungs, or unpaired abdomen. If present, shall be consistent with any laterality information indicated in ImagingStudy.series.bodySite. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Codes describing body site laterality (left, right, etc.). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| specimen | Σ C | 0..* | Reference(Specimen) | There are no (further) constraints on this element Element idImagingStudy.series.specimenShort description Specimen imaged DefinitionThe specimen imaged, e.g., for whole slide imaging of a biopsy. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| started | Σ | 0..1 | dateTime | There are no (further) constraints on this element Element idImagingStudy.series.startedShort description When the series started DefinitionThe date and time the series was started. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| performer | S Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element idImagingStudy.series.performerShort description Who performed the series Alternate namesPerformingPhysicianName, OperatorName DefinitionIndicates who or what performed the series and how they were involved. The performer is recorded at the series level, since each series in a study may be performed by a different performer, at different times, and using different devices. A series may be performed by multiple performers. If the person who performed the series is not known, their Organization may be recorded. A patient, or related person, may be the performer, e.g. for patient-captured images. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | Σ ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.modifierExtensionShort description Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| function | S Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.series.performer.functionShort description Type of performance DefinitionDistinguishes the type of involvement of the performer in the series. Allows disambiguation of the types of involvement of different performers. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The type of involvement of the performer. ImagingStudySeriesPerformerFunction (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| coding | S Σ | 1..* | Coding | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.codingShort description Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| text | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.textShort description Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| actor | S Σ C | 1..1 | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | Element idImagingStudy.series.performer.actorShort description Who performed the series DefinitionIndicates who or what performed the series. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(MIOrganization | MIPractitioner | MIPractitionerRole) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| instance | S | 1..* | BackboneElement | There are no (further) constraints on this element Element idImagingStudy.series.instanceShort description A single SOP instance from the series DefinitionA single SOP instance within the series, e.g. an image, or presentation state. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.instance.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | Σ ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.instance.modifierExtensionShort description Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| uid | S | 1..1 | id | There are no (further) constraints on this element Element idImagingStudy.series.instance.uidShort description DICOM SOP Instance UID Alternate namesSOPInstanceUID DefinitionThe DICOM SOP Instance UID for this image or other DICOM content. DICOM SOP Instance UID. See DICOM PS3.3 C.12.1. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 2.16.124.113543.6003.189642796.63084.16748.2599092903Mappings
| ||
| sopClass | S | 1..1 | CodingBinding | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClassShort description DICOM class type Alternate namesSOPClassUID DefinitionDICOM instance type. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. The sopClass for the instance. http://dicom.nema.org/medical/dicom/current/output/chtml/part04/sect_B.5.html#table_B.5-1 (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| number | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.series.instance.numberShort description The number of this instance in the series Alternate namesInstanceNumber DefinitionThe number of instance in the series. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 1Mappings
| |||
| title | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.titleShort description Description of instance DefinitionThe description of the instance. Particularly for post-acquisition analytic objects, such as SR, presentation states, value mapping, etc. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
|
| MIImagingStudy (ImagingStudy) | C | ImagingStudy | There are no (further) constraints on this element Element idImagingStudyShort description A set of images produced in single study (one or more series of references images) DefinitionRepresentation of the content produced in a DICOM imaging study. A study comprises a set of series, each of which includes a set of Service-Object Pair Instances (SOP Instances - images or other data) acquired or produced in a common context. A series is of only one modality (e.g. X-ray, CT, MR, ultrasound), but a study may have multiple series of different modalities.
| |||
| id | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.idShort description Logical id of this artifact DefinitionThe logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. The only time that a resource does not have an id is when it is being submitted to the server using a create operation. | ||
| meta | Σ | 0..1 | Meta | There are no (further) constraints on this element Element idImagingStudy.metaShort description Metadata about the resource DefinitionThe metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| implicitRules | Σ ?! | 0..1 | uri | There are no (further) constraints on this element Element idImagingStudy.implicitRulesShort description A set of rules under which this content was created DefinitionA reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| language | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.languageShort description Language of the resource content DefinitionThe base language in which the resource is written. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). A human language.
The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| |||
| text | 0..1 | Narrative | There are no (further) constraints on this element Element idImagingStudy.textShort description Text summary of the resource, for human interpretation Alternate namesnarrative, html, xhtml, display DefinitionA human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| |||
| contained | 0..* | Resource | There are no (further) constraints on this element Element idImagingStudy.containedShort description Contained, inline Resources Alternate namesinline resources, anonymous resources, contained resources DefinitionThese resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.
| |||
| extension | S C | 1..* | Extension | There are no (further) constraints on this element Element idImagingStudy.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| imagingStudyServiceType | S C | 1..1 | Extension(Coding) | Element idImagingStudy.extension:imagingStudyServiceTypeShort description Optional Extensions Element Alternate namesextensions, user content DefinitionOptional Extension Element - found in all resources. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. https://ontariohealth.ca/fhir/mi/StructureDefinition/ca-on-mi-ext-imagingStudyServiceType ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.modifierExtensionShort description Extensions that cannot be ignored Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | S Σ | 1..* | Identifier | Element idImagingStudy.identifierShort description Identifiers for the whole study Alternate namesStudyInstanceUID, AccessionNumber DefinitionIdentifiers for the ImagingStudy such as DICOM Study Instance UID, and Accession Number. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier (see DICOM PS 3.3 C.7.2. See discussion under Imaging Study Implementation Notes for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type. Unordered, Open, by type.coding.code(Value), system(Value) must contain one repetition of an accession number. ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier-accession | S Σ | 1..1 | Identifier | Element idImagingStudy.identifier:identifier-accessionShort description Filler/Accession ID Alternate namesStudyInstanceUID, AccessionNumber DefinitionIdentifiers for the ImagingStudy such as DICOM Study Instance UID, and Accession Number. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier (see DICOM PS 3.3 C.7.2. See discussion under Imaging Study Implementation Notes for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | S Σ | 1..1 | CodeableConceptBindingFixed Value | Element idImagingStudy.identifier:identifier-accession.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
{
"coding": [
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0203",
"code": "ACSN",
"display": "Accession ID"
}
]
}Mappings
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| coding | S Σ | 1..1 | CodingFixed Value | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.codingShort description Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
{
"system": "http://terminology.hl7.org/CodeSystem/v2-0203",
"code": "ACSN",
"display": "Accession ID"
}Mappings
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uriFixed Value | Element idImagingStudy.identifier:identifier-accession.type.coding.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
http://terminology.hl7.org/CodeSystem/v2-0203Mappings
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | codeFixed Value | Element idImagingStudy.identifier:identifier-accession.type.coding.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
ACSNMappings
| ||
| display | S Σ | 1..1 | stringFixed Value | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
Accession IDMappings
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.coding.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| text | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.type.textShort description Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | Element idImagingStudy.identifier:identifier-accession.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. MI uses source organization specific URIs for this field. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-accession.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier-studyInstanceUID | S Σ | 1..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUIDShort description Identifiers for the whole study Alternate namesStudyInstanceUID, AccessionNumber DefinitionIdentifiers for the ImagingStudy such as DICOM Study Instance UID, and Accession Number. If one or more series elements are present in the ImagingStudy, then there shall be one DICOM Study UID identifier (see DICOM PS 3.3 C.7.2. See discussion under Imaging Study Implementation Notes for encoding of DICOM Study Instance UID. Accession Number should use ACSN Identifier type. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uriFixed Value | Element idImagingStudy.identifier:identifier-studyInstanceUID.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
urn:dicom:uidExamples General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.identifier:identifier-studyInstanceUID.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| status | S Σ ?! | 1..1 | codeBindingFixed Value | Element idImagingStudy.statusShort description registered | available | cancelled | entered-in-error | unknown DefinitionThe current state of the ImagingStudy. Unknown does not represent "other" - one of the defined statuses must apply. Unknown is used when the authoring system is not sure what the current status is. The status of the ImagingStudy. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
availableMappings
| ||
| modality | S Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element idImagingStudy.modalityShort description All series modality if actual acquisition modalities Alternate namesModalitiesInStudy DefinitionA list of all the series.modality values that are actual acquisition modalities, i.e. those in the DICOM Context Group 29 (value set OID 1.2.840.10008.6.1.19). Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Type of acquired data in the instance. AcquisitionModality (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.modality.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.modality.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.modality.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.modality.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.modality.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.modality.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.modality.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| subject | S Σ C | 1..1 | Reference(MIPatient) | Element idImagingStudy.subjectShort description Who or what is the subject of the study DefinitionThe subject, typically a patient, of the imaging study. QA phantoms can be recorded with a Device; multiple subjects (such as mice) can be recorded with a Group. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.subject.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.subject.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.subject.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.subject.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.subject.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.subject.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| encounter | Σ C | 0..1 | Reference(Encounter) | There are no (further) constraints on this element Element idImagingStudy.encounterShort description Encounter with which this imaging study is associated DefinitionThe healthcare event (e.g. a patient and healthcare provider interaction) during which this ImagingStudy is made. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission test). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| started | S Σ | 0..1 | dateTime | There are no (further) constraints on this element Element idImagingStudy.startedShort description When the study was started Alternate namesStudyDate, StudyTime DefinitionDate and time the study started. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 2011-01-01T11:01:20+03:00Mappings
| ||
| basedOn | S Σ C | 0..* | Reference(MIServiceRequest) | Element idImagingStudy.basedOnShort description Request fulfilled DefinitionA list of the diagnostic requests that resulted in this imaging study being performed. To support grouped procedures (one imaging study supporting multiple ordered procedures, e.g. chest/abdomen/pelvis CT). References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.basedOn.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.basedOn.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | S Σ | 1..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | S Σ | 1..1 | CodeableConceptBinding | Element idImagingStudy.basedOn.identifier.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. http://ontariohealth.ca/fhir/ValueSet/identifier-type (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.basedOn.identifier.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.basedOn.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| referrer | S Σ C | 0..1 | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | Element idImagingStudy.referrerShort description Referring physician Alternate namesReferringPhysiciansName DefinitionThe requesting/referring physician. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(MIOrganization | MIPractitioner | MIPractitionerRole) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.referrer.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.referrer.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.referrer.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | S Σ | 1..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.referrer.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.referrer.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.referrer.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| interpreter | S Σ C | 0..* | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | Element idImagingStudy.interpreterShort description Who interpreted images Alternate namesName of Physician(s) Reading Study DefinitionWho read the study and interpreted the images or other content. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(MIOrganization | MIPractitioner | MIPractitionerRole) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.interpreter.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.interpreter.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.interpreter.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | S Σ | 1..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.interpreter.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.interpreter.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.interpreter.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| endpoint | S Σ C | 0..* | Reference(EndpointEHR) | Element idImagingStudy.endpointShort description Study access endpoint DefinitionThe network service providing access (e.g., query, view, or retrieval) for the study. See implementation notes for information about using DICOM endpoints. A study-level endpoint applies to each series in the study, unless overridden by a series-level endpoint with the same Endpoint.connectionType. Access methods for viewing (e.g., IHE’s IID profile) or retrieving (e.g., DICOM’s WADO-URI and WADO-RS) the study or the study’s series or instances. The study-level baseLocation applies to each series in the study, unless overridden in series by a series-level baseLocation of the same type. Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG), formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances; or IHE Invoke Image Display (IID), which provides standard invocation of an imaging web viewer. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.endpoint.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.endpoint.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | S Σ | 1..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.useShort description usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.typeShort description Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.systemShort description The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General http://www.acme.com/identifiers/patientMappings
| ||
| value | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.valueShort description The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 123456Mappings
| ||
| period | Σ C | 0..1 | Period | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.periodShort description Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| assigner | Σ C | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idImagingStudy.endpoint.identifier.assignerShort description Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.endpoint.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| numberOfSeries | S Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.numberOfSeriesShort description Number of Study Related Series Alternate namesNumberOfStudyRelatedSeries DefinitionNumber of Series in the Study. This value given may be larger than the number of series elements this Resource contains due to resource availability, security, or other factors. This element should be present if any series elements are present. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| numberOfInstances | S Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.numberOfInstancesShort description Number of Study Related Instances Alternate namesNumberOfStudyRelatedInstances DefinitionNumber of SOP Instances in Study. This value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| procedureReference | Σ C | 0..1 | Reference(Procedure) | There are no (further) constraints on this element Element idImagingStudy.procedureReferenceShort description The performed Procedure reference DefinitionThe procedure which this ImagingStudy was part of. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| procedureCode | S Σ | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.procedureCodeShort description The performed procedure code Alternate namesProcedureCodeSequence DefinitionThe code for the performed procedure type. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The performed procedure type. http://www.rsna.org/RadLex_Playbook.aspx (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.procedureCode.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| coding | S Σ | 1..* | Coding | There are no (further) constraints on this element Element idImagingStudy.procedureCode.codingShort description Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.procedureCode.coding.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| text | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.procedureCode.textShort description Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| location | Σ C | 0..1 | Reference(Location) | There are no (further) constraints on this element Element idImagingStudy.locationShort description Where ImagingStudy occurred DefinitionThe principal physical location where the ImagingStudy was performed. Ties the event to where the records are likely kept and provides context around the event occurrence (e.g. if it occurred inside or outside a dedicated healthcare setting). References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reasonCode | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element idImagingStudy.reasonCodeShort description Why the study was requested DefinitionDescription of clinical condition indicating why the ImagingStudy was requested. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The reason for the study. ProcedureReasonCodes (example) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reasonReference | Σ C | 0..* | Reference(Condition | DiagnosticReport | DocumentReference | Media | Observation) | There are no (further) constraints on this element Element idImagingStudy.reasonReferenceShort description Why was study performed DefinitionIndicates another resource whose existence justifies this Study. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(Condition | DiagnosticReport | DocumentReference | Media | Observation) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| note | Σ | 0..* | Annotation | There are no (further) constraints on this element Element idImagingStudy.noteShort description User-defined comments DefinitionPer the recommended DICOM mapping, this element is derived from the Study Description attribute (0008,1030). Observations or findings about the imaging study should be recorded in another resource, e.g. Observation, and not in this element. For systems that do not have structured annotations, they can simply communicate a single annotation with no author or time. This element may need to be included in narrative because of the potential for modifying information. Annotations SHOULD NOT be used to communicate "modifying" information that could be computable. (This is a SHOULD because enforcing user behavior is nearly impossible). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| description | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.descriptionShort description Institution-generated description Alternate namesStudyDescription DefinitionThe Imaging Manager description of the study. Institution-generated description or classification of the Study (component) performed. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| series | S Σ | 1..* | BackboneElement | There are no (further) constraints on this element Element idImagingStudy.seriesShort description Each study has one or more series of instances DefinitionEach study has one or more series of images or other content. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | Σ ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.modifierExtensionShort description Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| uid | S Σ | 1..1 | id | There are no (further) constraints on this element Element idImagingStudy.series.uidShort description DICOM Series Instance UID for the series Alternate namesSeriesInstanceUID DefinitionThe DICOM Series Instance UID for the series. DICOM Series Instance UID. See DICOM PS3.3 C.7.3. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 2.16.124.113543.6003.2588828330.45298.17418.2723805630Mappings
| ||
| number | Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.series.numberShort description Numeric identifier of this series Alternate namesSeriesNumber DefinitionThe numeric identifier of this series in the study. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 3Mappings
| ||
| modality | S Σ | 1..1 | CodingBinding | There are no (further) constraints on this element Element idImagingStudy.series.modalityShort description The modality of the instances in the series Alternate namesModality DefinitionThe modality of this series sequence. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Type of acquired data in the instance. AcquisitionModality (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.modality.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.modality.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.series.modality.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.modality.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.series.modality.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.modality.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.series.modality.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| description | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.descriptionShort description A short human readable summary of the series Alternate namesSeriesDescription DefinitionA description of the series. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General CT Surview 180Mappings
| ||
| numberOfInstances | S Σ | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.series.numberOfInstancesShort description Number of Series Related Instances Alternate namesNumberOfSeriesRelatedInstances DefinitionNumber of SOP Instances in the Study. The value given may be larger than the number of instance elements this resource contains due to resource availability, security, or other factors. This element should be present if any instance elements are present. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| endpoint | Σ C | 0..* | Reference(Endpoint) | There are no (further) constraints on this element Element idImagingStudy.series.endpointShort description Series access endpoint DefinitionThe network service providing access (e.g., query, view, or retrieval) for this series. See implementation notes for information about using DICOM endpoints. A series-level endpoint, if present, has precedence over a study-level endpoint with the same Endpoint.connectionType. Access methods for retrieving (e.g., DICOM’s WADO-URI and WADO-RS) the series or the series’ instances. A baseLocation specified at the series level has precedence over a baseLocation of the same type specified at the study level. Typical endpoint types include DICOM WADO-RS, which is used to retrieve DICOM instances in native or rendered (e.g., JPG, PNG) formats using a RESTful API; DICOM WADO-URI, which can similarly retrieve native or rendered instances, except using an HTTP query-based approach; and DICOM QIDO-RS, which allows RESTful query for DICOM information without retrieving the actual instances. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| bodySite | Σ | 0..1 | Coding | There are no (further) constraints on this element Element idImagingStudy.series.bodySiteShort description Body part examined Alternate namesBodyPartExamined DefinitionThe anatomic structures examined. See DICOM Part 16 Annex L (http://dicom.nema.org/medical/dicom/current/output/chtml/part16/chapter_L.html) for DICOM to SNOMED-CT mappings. The bodySite may indicate the laterality of body part imaged; if so, it shall be consistent with any content of ImagingStudy.series.laterality. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Codes describing anatomical locations. May include laterality. SNOMEDCTBodyStructures (example) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| laterality | Σ | 0..1 | Coding | There are no (further) constraints on this element Element idImagingStudy.series.lateralityShort description Body part laterality DefinitionThe laterality of the (possibly paired) anatomic structures examined. E.g., the left knee, both lungs, or unpaired abdomen. If present, shall be consistent with any laterality information indicated in ImagingStudy.series.bodySite. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Codes describing body site laterality (left, right, etc.). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| specimen | Σ C | 0..* | Reference(Specimen) | There are no (further) constraints on this element Element idImagingStudy.series.specimenShort description Specimen imaged DefinitionThe specimen imaged, e.g., for whole slide imaging of a biopsy. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| started | Σ | 0..1 | dateTime | There are no (further) constraints on this element Element idImagingStudy.series.startedShort description When the series started DefinitionThe date and time the series was started. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| performer | S Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element idImagingStudy.series.performerShort description Who performed the series Alternate namesPerformingPhysicianName, OperatorName DefinitionIndicates who or what performed the series and how they were involved. The performer is recorded at the series level, since each series in a study may be performed by a different performer, at different times, and using different devices. A series may be performed by multiple performers. If the person who performed the series is not known, their Organization may be recorded. A patient, or related person, may be the performer, e.g. for patient-captured images. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | Σ ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.modifierExtensionShort description Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| function | S Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element idImagingStudy.series.performer.functionShort description Type of performance DefinitionDistinguishes the type of involvement of the performer in the series. Allows disambiguation of the types of involvement of different performers. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The type of involvement of the performer. ImagingStudySeriesPerformerFunction (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| coding | S Σ | 1..* | Coding | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.codingShort description Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.coding.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| text | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.function.textShort description Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| actor | S Σ C | 1..1 | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | Element idImagingStudy.series.performer.actorShort description Who performed the series DefinitionIndicates who or what performed the series. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(MIOrganization | MIPractitioner | MIPractitionerRole) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| reference | S Σ C | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.referenceShort description Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server. The cardinality or value of this element may be affected by these constraints: ele-1, ref-1 Constraints
| ||
| type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.typeShort description Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.identifierShort description Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any). The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.performer.actor.displayShort description Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| instance | S | 1..* | BackboneElement | There are no (further) constraints on this element Element idImagingStudy.series.instanceShort description A single SOP instance from the series DefinitionA single SOP instance within the series, e.g. an image, or presentation state. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.instance.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| modifierExtension | Σ ?! C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.instance.modifierExtensionShort description Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| uid | S | 1..1 | id | There are no (further) constraints on this element Element idImagingStudy.series.instance.uidShort description DICOM SOP Instance UID Alternate namesSOPInstanceUID DefinitionThe DICOM SOP Instance UID for this image or other DICOM content. DICOM SOP Instance UID. See DICOM PS3.3 C.12.1. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 2.16.124.113543.6003.189642796.63084.16748.2599092903Mappings
| ||
| sopClass | S | 1..1 | CodingBinding | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClassShort description DICOM class type Alternate namesSOPClassUID DefinitionDICOM instance type. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. The sopClass for the instance. http://dicom.nema.org/medical/dicom/current/output/chtml/part04/sect_B.5.html#table_B.5-1 (extensible) ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| id | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.idShort description Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |||
| extension | C | 0..* | Extension | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.extensionShort description Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url ConditionsThe cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| system | S Σ | 1..1 | uri | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.systemShort description Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| version | Σ | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.versionShort description Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| code | S Σ | 1..1 | code | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.codeShort description Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| display | S Σ | 1..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.displayShort description Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idImagingStudy.series.instance.sopClass.userSelectedShort description If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
| ||
| number | 0..1 | unsignedInt | There are no (further) constraints on this element Element idImagingStudy.series.instance.numberShort description The number of this instance in the series Alternate namesInstanceNumber DefinitionThe number of instance in the series. 32 bit number; for values larger than this, use decimal The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
General 1Mappings
| |||
| title | 0..1 | string | There are no (further) constraints on this element Element idImagingStudy.series.instance.titleShort description Description of instance DefinitionThe description of the instance. Particularly for post-acquisition analytic objects, such as SR, presentation states, value mapping, etc. The cardinality or value of this element may be affected by these constraints: ele-1 Constraints
|
| ImagingStudy | .. | |
| ImagingStudy.extension | 1.. | |
| ImagingStudy.extension:imagingStudyServiceType | Extension | 1..1 |
| ImagingStudy.identifier | 1.. | |
| ImagingStudy.identifier:identifier-accession | 1..1 | |
| ImagingStudy.identifier:identifier-accession.type | 1.. | |
| ImagingStudy.identifier:identifier-accession.type.coding | 1..1 | |
| ImagingStudy.identifier:identifier-accession.type.coding.system | 1.. | |
| ImagingStudy.identifier:identifier-accession.type.coding.code | 1.. | |
| ImagingStudy.identifier:identifier-accession.type.coding.display | 1.. | |
| ImagingStudy.identifier:identifier-accession.system | 1.. | |
| ImagingStudy.identifier:identifier-accession.value | 1.. | |
| ImagingStudy.identifier:identifier-studyInstanceUID | 1..1 | |
| ImagingStudy.identifier:identifier-studyInstanceUID.system | 1.. | |
| ImagingStudy.identifier:identifier-studyInstanceUID.value | 1.. | |
| ImagingStudy.status | .. | |
| ImagingStudy.modality | .. | |
| ImagingStudy.modality.system | 1.. | |
| ImagingStudy.modality.code | 1.. | |
| ImagingStudy.modality.display | 1.. | |
| ImagingStudy.subject | Reference(MIPatient) | .. |
| ImagingStudy.subject.reference | 1.. | |
| ImagingStudy.started | .. | |
| ImagingStudy.basedOn | Reference(MIServiceRequest) | .. |
| ImagingStudy.basedOn.reference | 1.. | |
| ImagingStudy.basedOn.identifier | 1.. | |
| ImagingStudy.basedOn.identifier.type | 1.. | |
| ImagingStudy.basedOn.identifier.system | 1.. | |
| ImagingStudy.basedOn.identifier.value | 1.. | |
| ImagingStudy.referrer | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | .. |
| ImagingStudy.referrer.reference | 1.. | |
| ImagingStudy.referrer.type | 1.. | |
| ImagingStudy.interpreter | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | .. |
| ImagingStudy.interpreter.reference | 1.. | |
| ImagingStudy.interpreter.type | 1.. | |
| ImagingStudy.endpoint | Reference(EndpointEHR) | .. |
| ImagingStudy.endpoint.reference | 1.. | |
| ImagingStudy.endpoint.identifier | 1.. | |
| ImagingStudy.endpoint.identifier.system | 1.. | |
| ImagingStudy.endpoint.identifier.value | 1.. | |
| ImagingStudy.numberOfSeries | .. | |
| ImagingStudy.numberOfInstances | .. | |
| ImagingStudy.procedureCode | .. | |
| ImagingStudy.procedureCode.coding | 1.. | |
| ImagingStudy.procedureCode.coding.system | 1.. | |
| ImagingStudy.procedureCode.coding.code | 1.. | |
| ImagingStudy.procedureCode.coding.display | 1.. | |
| ImagingStudy.description | 1.. | |
| ImagingStudy.series | 1.. | |
| ImagingStudy.series.uid | .. | |
| ImagingStudy.series.modality | .. | |
| ImagingStudy.series.modality.system | 1.. | |
| ImagingStudy.series.modality.code | 1.. | |
| ImagingStudy.series.modality.display | 1.. | |
| ImagingStudy.series.numberOfInstances | .. | |
| ImagingStudy.series.performer | .. | |
| ImagingStudy.series.performer.function | .. | |
| ImagingStudy.series.performer.function.coding | 1.. | |
| ImagingStudy.series.performer.function.coding.system | 1.. | |
| ImagingStudy.series.performer.function.coding.code | 1.. | |
| ImagingStudy.series.performer.function.coding.display | 1.. | |
| ImagingStudy.series.performer.actor | Reference(MIOrganization | MIPractitioner | MIPractitionerRole) | .. |
| ImagingStudy.series.performer.actor.reference | 1.. | |
| ImagingStudy.series.instance | 1.. | |
| ImagingStudy.series.instance.uid | .. | |
| ImagingStudy.series.instance.sopClass | .. | |
| ImagingStudy.series.instance.sopClass.system | 1.. | |
| ImagingStudy.series.instance.sopClass.code | 1.. | |
| ImagingStudy.series.instance.sopClass.display | 1.. |
.extension(ImagingStudyCategory)
.identifier
.status
.modality
.subject
.started
.basedOn
.referrer
.interpreter
.endpoint.reference
_include=ImagingStudy:endpoint is used in the query, or a string pointing to the endpoint where consumer can resolve in their system (e.g. AGFA viewer)..endpoint.identifier
identifier.value, identifer.system SHALL contain the local URI of the assigning authority of AE title, e.g http://ontariohealth.ca/mi/fhir/NamingSystem/ocinet-imaging-dicom-application-entity-title.numberOfSeries
.numberOfInstances
.procedureCode
.location
.reasonCode
.note
.description
.series.uid
.series.number
.series.modality
.series.description
.series.numberOfInstances
.series.performer
.series.endpoint
.series.bodySite
.series.laterality
.series.started
.series.performer
.series.instance.uid
.series.instance.sopClass
.series.instance.number
.series.instance.title
| Path | Conformance | ValueSet |
|---|---|---|
| ImagingStudy.basedOn.identifier.type | extensible | http://ontariohealth.ca/fhir/ValueSet/identifier-type |
Powered by SIMPLIFIER.NET