NICE-HeartRate

Description

This profile is for submitting the patient's lowest and highest heart rate in beats/min to the NICE.

Click here to go to the NICE-HeartRate Simplifier page

MDS Sepsis
Lowest heart rate Tachycar
Highest heart rate

Source

This profile is used to submit heart rate related information to the Dutch National Intensive Care Evaluation (NICE). It was derived from the Nictiz Health and Care Information Model (HCIM; Dutch: Zorginformatiebouwsteen or ZIB) HeartRate, 2017 release version 3.1


idΣ0..1id
metaΣ0..1Meta
implicitRulesΣ ?!0..1uri
language0..1codeBinding
textI0..1Narrative
contained0..*Resource
id0..1string
extensionI0..*Extension
url1..1uriFixed Value
id0..1string
extensionI0..*Extension
codingΣ0..1Coding
textΣ0..1code
VerifiedS I1..1Extension(CodeableConcept)
modifierExtension?! I0..*Extension
identifierΣ0..*Identifier
basedOnΣ I0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ProcedureRequest | ReferralRequest)
statusS Σ ?!1..1codeBindingFixed Value
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ0..1uriFixed Value
versionΣ0..1string
codeΣ0..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ0..1uriFixed Value
versionΣ0..1string
codeΣ0..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ1..1uriFixed Value
versionΣ0..1string
codeΣ1..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
subjectS Σ I1..1Reference(NICE-Patient)
contextS I0..1Reference(NICE-Encounter)
effectiveDateTimeS Σ1..1dateTime
issuedΣ0..1instant
id0..1string
practitionerRoleI0..1Extension(Reference(nl-core-practitionerrole))
referenceΣ I0..1string
identifierΣ0..1Identifier
displayΣ0..1string
id0..1string
extensionI0..*Extension
valueS Σ1..1decimal
comparatorΣ ?!0..1codeBinding
unitS Σ1..1string
systemS Σ I1..1uriFixed Value
codeS Σ1..1codeFixed Value
dataAbsentReasonS I0..1CodeableConceptBinding
interpretation0..1CodeableConceptBinding
comment0..1string
bodySite0..1CodeableConcept
method0..1CodeableConceptBinding
specimenI0..1Reference(Specimen)
deviceI0..1Reference(HCIM MedicalDevice Product)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
lowI0..1SimpleQuantity
highI0..1SimpleQuantity
type0..1CodeableConceptBinding
appliesTo0..*CodeableConcept
ageI0..1Range
text0..1string
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
typeS1..1codeBindingFixed Value
targetS I1..1Reference(VitalSigns Profile NL)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
codeS Σ1..1CodeableConceptBinding
valueQuantityQuantity
valueCodeableConceptCodeableConcept
valueStringstring
valueRangeRange
valueRatioRatio
valueSampledDataSampledData
valueAttachmentAttachment
valueTimetime
valueDateTimedateTime
valuePeriodPeriod
dataAbsentReasonS I0..1CodeableConceptBinding
interpretation0..1CodeableConceptBinding
referenceRange0..*see (referenceRange)

idΣ0..1id
metaΣ0..1Meta
implicitRulesΣ ?!0..1uri
language0..1codeBinding
textI0..1Narrative
contained0..*Resource
id0..1string
extensionI0..*Extension
url1..1uriFixed Value
id0..1string
extensionI0..*Extension
codingΣ0..1Coding
textΣ0..1code
VerifiedS I1..1Extension(CodeableConcept)
modifierExtension?! I0..*Extension
identifierΣ0..*Identifier
basedOnΣ I0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ProcedureRequest | ReferralRequest)
statusS Σ ?!1..1codeBindingFixed Value
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ0..1uriFixed Value
versionΣ0..1string
codeΣ0..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ0..1uriFixed Value
versionΣ0..1string
codeΣ0..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ1..1uriFixed Value
versionΣ0..1string
codeΣ1..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
subjectS Σ I1..1Reference(NICE-Patient)
contextS I0..1Reference(NICE-Encounter)
effectiveDateTimeS Σ1..1dateTime
issuedΣ0..1instant
id0..1string
practitionerRoleI0..1Extension(Reference(nl-core-practitionerrole))
referenceΣ I0..1string
identifierΣ0..1Identifier
displayΣ0..1string
id0..1string
extensionI0..*Extension
valueS Σ1..1decimal
comparatorΣ ?!0..1codeBinding
unitS Σ1..1string
systemS Σ I1..1uriFixed Value
codeS Σ1..1codeFixed Value
dataAbsentReasonS I0..1CodeableConceptBinding
interpretation0..1CodeableConceptBinding
comment0..1string
bodySite0..1CodeableConcept
method0..1CodeableConceptBinding
specimenI0..1Reference(Specimen)
deviceI0..1Reference(HCIM MedicalDevice Product)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
lowI0..1SimpleQuantity
highI0..1SimpleQuantity
type0..1CodeableConceptBinding
appliesTo0..*CodeableConcept
ageI0..1Range
text0..1string
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
typeS1..1codeBindingFixed Value
targetS I1..1Reference(VitalSigns Profile NL)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
codeS Σ1..1CodeableConceptBinding
valueQuantityQuantity
valueCodeableConceptCodeableConcept
valueStringstring
valueRangeRange
valueRatioRatio
valueSampledDataSampledData
valueAttachmentAttachment
valueTimetime
valueDateTimedateTime
valuePeriodPeriod
dataAbsentReasonS I0..1CodeableConceptBinding
interpretation0..1CodeableConceptBinding
referenceRange0..*see (referenceRange)

idΣ0..1id
metaΣ0..1Meta
implicitRulesΣ ?!0..1uri
language0..1codeBinding
textI0..1Narrative
contained0..*Resource
id0..1string
extensionI0..*Extension
url1..1uriFixed Value
id0..1string
extensionI0..*Extension
codingΣ0..1Coding
textΣ0..1code
VerifiedS I1..1Extension(CodeableConcept)
modifierExtension?! I0..*Extension
identifierΣ0..*Identifier
basedOnΣ I0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ProcedureRequest | ReferralRequest)
statusS Σ ?!1..1codeBindingFixed Value
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ0..1uriFixed Value
versionΣ0..1string
codeΣ0..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ0..1uriFixed Value
versionΣ0..1string
codeΣ0..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemΣ1..1uriFixed Value
versionΣ0..1string
codeΣ1..1codeFixed Value
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
subjectS Σ I1..1Reference(NICE-Patient)
contextS I0..1Reference(NICE-Encounter)
effectiveDateTimeS Σ1..1dateTime
issuedΣ0..1instant
id0..1string
practitionerRoleI0..1Extension(Reference(nl-core-practitionerrole))
referenceΣ I0..1string
identifierΣ0..1Identifier
displayΣ0..1string
id0..1string
extensionI0..*Extension
valueS Σ1..1decimal
comparatorΣ ?!0..1codeBinding
unitS Σ1..1string
systemS Σ I1..1uriFixed Value
codeS Σ1..1codeFixed Value
dataAbsentReasonS I0..1CodeableConceptBinding
interpretation0..1CodeableConceptBinding
comment0..1string
bodySite0..1CodeableConcept
method0..1CodeableConceptBinding
specimenI0..1Reference(Specimen)
deviceI0..1Reference(HCIM MedicalDevice Product)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
lowI0..1SimpleQuantity
highI0..1SimpleQuantity
type0..1CodeableConceptBinding
appliesTo0..*CodeableConcept
ageI0..1Range
text0..1string
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
typeS1..1codeBindingFixed Value
targetS I1..1Reference(VitalSigns Profile NL)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
codeS Σ1..1CodeableConceptBinding
valueQuantityQuantity
valueCodeableConceptCodeableConcept
valueStringstring
valueRangeRange
valueRatioRatio
valueSampledDataSampledData
valueAttachmentAttachment
valueTimetime
valueDateTimedateTime
valuePeriodPeriod
dataAbsentReasonS I0..1CodeableConceptBinding
interpretation0..1CodeableConceptBinding
referenceRange0..*see (referenceRange)

Mapping FHIR profile NICE data dictionary

Pathidentitymapcomment
Observation.valueQuantity:valueQuantityNICE-Datadictionary-MDShttps://www.stichting-nice.nl/dd/#148Lowest heart rate
Observation.valueQuantity:valueQuantityNICE-Datadictionary-MDShttps://www.stichting-nice.nl/dd/#147Highest heart rate
Observation.valueQuantity:valueQuantityNICE-Datadictionary-Sepsishttps://www.stichting-nice.nl/dd/#662Tachycardia
{
    "resourceType": "Observation",
    "id": "NICE-HeartRate-Example-01",
    "meta": {
        "profile":  [
            "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-HeartRate-2022Q1"
        ]
    },
    "text": {
        --- We have skipped the narrative for better readability of the resource ---
    },
    "extension":  [
        {
            "url": "https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Verified-2022Q1",
            "valueCodeableConcept": {
                "coding":  [
                    {
                        "system": "http://terminology.hl7.org/ValueSet/v2-0532",
                        "code": "Y",
                        "display": "Yes"
                    }
                ]
            }
        }
    ],
    "status": "final",
    "category":  [
        {
            "coding":  [
                {
                    "system": "https://fhir.stichting-nice.nl/NICE-codes",
                    "code": "VS",
                    "display": "vital-signs"
                }
            ]
        }
    ],
    "code": {
        "coding":  [
            {
                "system": "http://loinc.org",
                "code": "8867-4",
                "display": "Heart rate"
            }
        ]
    },
    "subject": {
        "reference": "Patient/NICE-Patient-01",
        "display": "P. Petersen"
    },
    "context": {
        "reference": "Encounter/NICE-Encounter-01"
    },
    "effectiveDateTime": "2022-01-08T08:43:00+02:00",
    "valueQuantity": {
        "value": 90,
        "unit": "/min",
        "system": "http://unitsofmeasure.org",
        "code": "/min"
    }
}
<Observation xmlns="http://hl7.org/fhir">
    <id value="NICE-HeartRate-Example-01" />
    <meta>
        <profile value="https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-HeartRate-2022Q1" />
    </meta>
    <text>
        <status />
        --- We have skipped the narrative for better readability of the resource ---
    </text>
    <extension url="https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Verified-2022Q1">
        <valueCodeableConcept>
            <coding>
                <system value="http://terminology.hl7.org/ValueSet/v2-0532" />
                <code value="Y" />
                <display value="Yes" />
            </coding>
        </valueCodeableConcept>
    </extension>
    <status value="final" />
    <category>
        <coding>
            <system value="https://fhir.stichting-nice.nl/NICE-codes" />
            <code value="VS" />
            <display value="vital-signs" />
        </coding>
    </category>
    <code>
        <coding>
            <system value="http://loinc.org" />
            <code value="8867-4" />
            <display value="Heart rate" />
        </coding>
    </code>
    <subject>
        <reference value="Patient/NICE-Patient-01" />
        <display value="P. Petersen" />
    </subject>
    <context>
        <reference value="Encounter/NICE-Encounter-01" />
    </context>
    <effectiveDateTime value="2022-01-08T08:43:00+02:00" />
    <valueQuantity>
        <value value="90" />
        <unit value="/min" />
        <system value="http://unitsofmeasure.org" />
        <code value="/min" />
    </valueQuantity>
</Observation>