ForecastedDoseVolumeExtension
The FHIR extension is for Forecast Dose Volume purposes.
| Extension | C | |
| Short | Optional Extensions Element | |
| Definition | Optional Extension Element - found in all resources. | |
| Cardinality | 0..1 | |
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | |
| Constraints |
| |
| Mappings |
| |
| Extension.id | ||
| Short | Unique id for inter-element referencing | |
| Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | |
| Cardinality | 0..1 | |
| Type | string | |
| Mappings |
| |
| Extension.extension | C | |
| Short | Additional content defined by implementations | |
| Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | |
| Cardinality | 0..0 | |
| Type | Extension | |
| Alias | extensions, user content | |
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | |
| Slicing | Unordered, Open, by url(Value) Extensions are always sliced by (at least) url | |
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | |
| Constraints |
| |
| Mappings |
| |
| Extension.url | ||
| Short | identifies the meaning of the extension | |
| Definition | Source of the definition for the extension code - a logical name or a URL. | |
| Cardinality | 1..1 | |
| Type | uri | |
| Comments | The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension. | |
| Fixed Value | https://ehealth.bc.ca/fhir/StructureDefinition/bcy-ids-forecast-dose-volume | |
| Mappings |
| |
| Extension.value[x] | ||
| Short | Value of extension | |
| Definition | Value of extension - must be one of a constrained set of the data types (see Extensibility for a list). | |
| Cardinality | 0..1 | |
| Type | Quantity | |
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | |
| Constraints |
| |
| Mappings |
| |
| Extension.value[x].id | ||
| Short | Unique id for inter-element referencing | |
| Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. | |
| Cardinality | 0..1 | |
| Type | string | |
| Mappings |
| |
| Extension.value[x].extension | C | |
| Short | Additional content defined by implementations | |
| Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. | |
| Cardinality | 0..* | |
| Type | Extension | |
| Alias | extensions, user content | |
| Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. | |
| Slicing | Unordered, Open, by url(Value) Extensions are always sliced by (at least) url | |
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | |
| Constraints |
| |
| Mappings |
| |
| Extension.value[x].value | Σ | |
| Short | Numerical value (with implicit precision) | |
| Definition | The value of the measured amount. The value includes an implicit precision in the presentation of the value. | |
| Cardinality | 0..1 | |
| Type | decimal | |
| Summary | True | |
| Requirements | Precision is handled implicitly in almost all cases of measurement. | |
| Comments | The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books). | |
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | |
| Constraints |
| |
| Mappings |
| |
| Extension.value[x].comparator | Σ ?! | |
| Short | < | <= | >= | > - how to understand the value | |
| Definition | How the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value. | |
| Cardinality | 0..0 | |
| Type | code | |
| Binding | How the Quantity should be understood and represented. | |
| Modifier | True | |
| Summary | True | |
| Requirements | Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology. | |
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | |
| Meaning when missing | If there is no comparator, then there is no modification of the value | |
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | |
| Constraints |
| |
| Mappings |
| |
| Extension.value[x].unit | Σ | |
| Short | Unit representation | |
| Definition | A human-readable form of the unit. | |
| Cardinality | 0..1 | |
| Type | string | |
| Summary | True | |
| Requirements | There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms. | |
| Comments | Note that FHIR strings SHALL NOT exceed 1MB in size | |
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | |
| Constraints |
| |
| Mappings |
| |
| Extension.value[x].system | Σ C | |
| Short | System that defines coded unit form | |
| Definition | The identification of the system that provides the coded form of the unit. | |
| Cardinality | 0..0 | |
| Type | uri | |
| Summary | True | |
| Requirements | Need to know the system that defines the coded form of the unit. | |
| Comments | see http://en.wikipedia.org/wiki/Uniform_resource_identifier | |
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1, qty-3 | |
| Constraints |
| |
| Mappings |
| |
| Extension.value[x].code | Σ | |
| Short | Coded form of the unit | |
| Definition | A computer processable form of the unit in some unit representation system. | |
| Cardinality | 0..0 | |
| Type | code | |
| Summary | True | |
| Requirements | Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest. | |
| Comments | The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system. | |
| Conditions | The cardinality or value of this element may be affected by these constraints: ele-1 | |
| Constraints |
| |
| Mappings |
| |