Concepts to use when recording central venous pressure.
Currently if you are representing a CVP or other invasive blood pressures,
which appear to be in scope, there are no appropriate concepts to record
the systolic and diasolic pressures. It would not be correct to use
271649006 | Systolic blood pressure (observable entity) as this is not
what it is. So to represent correctly you would need to use a concept
specifically for invasive blood pressure.
|
Propose to use a concept such as
276776003 |Right atrial pressure - a wave (observable entity) | or 276772001 |Right ventricular systolic pressure (observable entity)|.
This would need validating with clinical experts.
|