StructureDefinition Extension-UKCore-CuffSize

Canonical_URLDescriptionProfile_Purpose
https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize

An extension to record the cuff size of a sphygmomanometer.

This extension is a clinical observation use case to record the cuff sized used on a sphygmomanometer when the blood pressure was measured.


Context of Use Device

Tree View

url1..1System.StringFixed Value
codingΣ0..*CodingBinding
textΣ0..1string

Table View

Extension..
Extension.url..
Extension.value[x]CodeableConcept1..
Extension.value[x].coding..


XML View

<StructureDefinition xmlns="http://hl7.org/fhir">
    <id value="Extension-UKCore-CuffSize" />
    <url value="https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize" />
    <version value="1.0.0" />
    <name value="ExtensionUKCoreCuffSize" />
    <title value="Extension UK Core Cuff Size" />
    <status value="draft" />
    <date value="2023-09-12" />
    <publisher value="HL7 UK" />
    <contact>
        <name value="HL7 UK" />
        <telecom>
            <system value="email" />
            <value value="ukcore@hl7.org.uk" />
            <use value="work" />
            <rank value="1" />
        </telecom>
    </contact>
    <description value="An extension to record the cuff size of a sphygmomanometer." />
    <purpose value="This extension is a clinical observation use case to record the cuff sized used on a sphygmomanometer when the blood pressure was measured." />
    <copyright value="Copyright &#169; 2021+ HL7 UK Licensed under the Apache License, Version 2.0 (the &quot;License&quot;); you may not use this file except in compliance with the License. You may obtain a copy of the License at  http://www.apache.org/licenses/LICENSE-2.0 Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an &quot;AS IS&quot; BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License for the specific language governing permissions and limitations under the License. HL7&#174; FHIR&#174; standard Copyright &#169; 2011+ HL7 The HL7&#174; FHIR&#174; standard is used under the FHIR license. You may obtain a copy of the FHIR license at  https://www.hl7.org/fhir/license.html." />
    <fhirVersion value="4.0.1" />
    <kind value="complex-type" />
    <abstract value="false" />
    <context>
        <type value="element" />
        <expression value="Device" />
    </context>
    <type value="Extension" />
    <baseDefinition value="http://hl7.org/fhir/StructureDefinition/Extension" />
    <derivation value="constraint" />
    <differential>
        <element id="Extension">
            <path value="Extension" />
            <short value="An extension to record the cuff size of a sphygmomanometer." />
            <definition value="This extension allows the recording of the cuff size of a sphygmomanometer used in a blood pressure reading." />
        </element>
        <element id="Extension.url">
            <path value="Extension.url" />
            <fixedUri value="https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize" />
        </element>
        <element id="Extension.value[x]">
            <path value="Extension.value[x]" />
            <short value="A set of codes to record the cuff size" />
            <min value="1" />
            <type>
                <code value="CodeableConcept" />
            </type>
        </element>
        <element id="Extension.value[x].coding">
            <path value="Extension.value[x].coding" />
            <binding>
                <strength value="preferred" />
                <description value="A set of codes to record the cuff size" />
                <valueSet value="https://fhir.hl7.org.uk/ValueSet/UKCore-BloodPressure-CuffSize" />
            </binding>
        </element>
    </differential>
</StructureDefinition>

JSON View

{
    "resourceType": "StructureDefinition",
    "id": "Extension-UKCore-CuffSize",
    "url": "https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize",
    "version": "1.0.0",
    "name": "ExtensionUKCoreCuffSize",
    "title": "Extension UK Core Cuff Size",
    "status": "draft",
    "date": "2023-09-12",
    "publisher": "HL7 UK",
    "contact":  [
        {
            "name": "HL7 UK",
            "telecom":  [
                {
                    "system": "email",
                    "value": "ukcore@hl7.org.uk",
                    "use": "work",
                    "rank": 1
                }
            ]
        }
    ],
    "description": "An extension to record the cuff size of a sphygmomanometer.",
    "purpose": "This extension is a clinical observation use case to record the cuff sized used on a sphygmomanometer when the blood pressure was measured.",
    "copyright": "Copyright © 2021+ HL7 UK Licensed under the Apache License, Version 2.0 (the \"License\"); you may not use this file except in compliance with the License. You may obtain a copy of the License at  http://www.apache.org/licenses/LICENSE-2.0 Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an \"AS IS\" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License for the specific language governing permissions and limitations under the License. HL7® FHIR® standard Copyright © 2011+ HL7 The HL7® FHIR® standard is used under the FHIR license. You may obtain a copy of the FHIR license at  https://www.hl7.org/fhir/license.html.",
    "fhirVersion": "4.0.1",
    "kind": "complex-type",
    "abstract": false,
    "context":  [
        {
            "type": "element",
            "expression": "Device"
        }
    ],
    "type": "Extension",
    "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Extension",
    "derivation": "constraint",
    "differential": {
        "element":  [
            {
                "id": "Extension",
                "path": "Extension",
                "short": "An extension to record the cuff size of a sphygmomanometer.",
                "definition": "This extension allows the recording of the cuff size of a sphygmomanometer used in a blood pressure reading."
            },
            {
                "id": "Extension.url",
                "path": "Extension.url",
                "fixedUri": "https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize"
            },
            {
                "id": "Extension.value[x]",
                "path": "Extension.value[x]",
                "short": "A set of codes to record the cuff size",
                "min": 1,
                "type":  [
                    {
                        "code": "CodeableConcept"
                    }
                ]
            },
            {
                "id": "Extension.value[x].coding",
                "path": "Extension.value[x].coding",
                "binding": {
                    "strength": "preferred",
                    "description": "A set of codes to record the cuff size",
                    "valueSet": "https://fhir.hl7.org.uk/ValueSet/UKCore-BloodPressure-CuffSize"
                }
            }
        ]
    }
}

Examples

Cuff Size - An example to illustrate a blood pressure monitoring device with a large cuff.
Example UKCore-Extension-CuffSize

Extension Specific Guidance

There is a binding within this extension to a ValueSet UKCore-BloodPressure-CuffSize.