StructureDefinition Extension-UKCore-CuffSize
Important
This Profile underwent Clinical and Technical Assurance during Sprint 7. This is a new Extension added to UK Core and should undergo review during the Sprint 7 review window.
Click here to Report Issue for Extension-UKCore-CuffSize.
Canonical_URL | Description | Profile_Purpose |
---|---|---|
https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize | An extension to record the cuff size of a sphygmomanometer. | This extension is a clinical observation use case to record the cuff sized used on a sphygmomanometer when the blood pressure was measured. |
Context of Use | Device |
Tree View
Extension | I | Extension | |
url | 1..1 | System.StringFixed Value | |
value[x] | 1..1 | ||
valueCodeableConcept | CodeableConcept | ||
coding | Σ | 0..* | CodingBinding |
text | Σ | 0..1 | string |
Table View
Extension | .. | |
Extension.url | .. | |
Extension.value[x] | CodeableConcept | 1.. |
Extension.value[x].coding | .. |
XML View
<StructureDefinition xmlns="http://hl7.org/fhir"> <id value="Extension-UKCore-CuffSize" /> <url value="https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize" /> <version value="1.0.0" /> <name value="ExtensionUKCoreCuffSize" /> <title value="Extension UK Core Cuff Size" /> <status value="draft" /> <date value="2023-09-12" /> <publisher value="HL7 UK" /> <contact> <name value="HL7 UK" /> <telecom> <system value="email" /> <value value="ukcore@hl7.org.uk" /> <use value="work" /> <rank value="1" /> </telecom> </contact> <description value="An extension to record the cuff size of a sphygmomanometer." /> <purpose value="This extension is a clinical observation use case to record the cuff sized used on a sphygmomanometer when the blood pressure was measured." /> <copyright value="Copyright © 2021+ HL7 UK Licensed under the Apache License, Version 2.0 (the "License"); you may not use this file except in compliance with the License. You may obtain a copy of the License at http://www.apache.org/licenses/LICENSE-2.0 Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an "AS IS" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License for the specific language governing permissions and limitations under the License. HL7® FHIR® standard Copyright © 2011+ HL7 The HL7® FHIR® standard is used under the FHIR license. You may obtain a copy of the FHIR license at https://www.hl7.org/fhir/license.html." /> <fhirVersion value="4.0.1" /> <kind value="complex-type" /> <abstract value="false" /> <context> <type value="element" /> <expression value="Device" /> </context> <type value="Extension" /> <baseDefinition value="http://hl7.org/fhir/StructureDefinition/Extension" /> <derivation value="constraint" /> <differential> <element id="Extension"> <path value="Extension" /> <short value="An extension to record the cuff size of a sphygmomanometer." /> <definition value="This extension allows the recording of the cuff size of a sphygmomanometer used in a blood pressure reading." /> </element> <element id="Extension.url"> <path value="Extension.url" /> <fixedUri value="https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize" /> </element> <element id="Extension.value[x]"> <path value="Extension.value[x]" /> <short value="A set of codes to record the cuff size" /> <min value="1" /> <type> <code value="CodeableConcept" /> </type> </element> <element id="Extension.value[x].coding"> <path value="Extension.value[x].coding" /> <binding> <strength value="preferred" /> <description value="A set of codes to record the cuff size" /> <valueSet value="https://fhir.hl7.org.uk/ValueSet/UKCore-BloodPressure-CuffSize" /> </binding> </element> </differential> </StructureDefinition>
JSON View
{ "resourceType": "StructureDefinition", "id": "Extension-UKCore-CuffSize", "url": "https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize", "version": "1.0.0", "name": "ExtensionUKCoreCuffSize", "title": "Extension UK Core Cuff Size", "status": "draft", "date": "2023-09-12", "publisher": "HL7 UK", "contact": [ { "name": "HL7 UK", "telecom": [ { "system": "email", "value": "ukcore@hl7.org.uk", "use": "work", "rank": 1 } ] } ], "description": "An extension to record the cuff size of a sphygmomanometer.", "purpose": "This extension is a clinical observation use case to record the cuff sized used on a sphygmomanometer when the blood pressure was measured.", "copyright": "Copyright © 2021+ HL7 UK Licensed under the Apache License, Version 2.0 (the \"License\"); you may not use this file except in compliance with the License. You may obtain a copy of the License at http://www.apache.org/licenses/LICENSE-2.0 Unless required by applicable law or agreed to in writing, software distributed under the License is distributed on an \"AS IS\" BASIS, WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. See the License for the specific language governing permissions and limitations under the License. HL7® FHIR® standard Copyright © 2011+ HL7 The HL7® FHIR® standard is used under the FHIR license. You may obtain a copy of the FHIR license at https://www.hl7.org/fhir/license.html.", "fhirVersion": "4.0.1", "kind": "complex-type", "abstract": false, "context": [ { "type": "element", "expression": "Device" } ], "type": "Extension", "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Extension", "derivation": "constraint", "differential": { "element": [ { "id": "Extension", "path": "Extension", "short": "An extension to record the cuff size of a sphygmomanometer.", "definition": "This extension allows the recording of the cuff size of a sphygmomanometer used in a blood pressure reading." }, { "id": "Extension.url", "path": "Extension.url", "fixedUri": "https://fhir.hl7.org.uk/StructureDefinition/Extension-UKCore-CuffSize" }, { "id": "Extension.value[x]", "path": "Extension.value[x]", "short": "A set of codes to record the cuff size", "min": 1, "type": [ { "code": "CodeableConcept" } ] }, { "id": "Extension.value[x].coding", "path": "Extension.value[x].coding", "binding": { "strength": "preferred", "description": "A set of codes to record the cuff size", "valueSet": "https://fhir.hl7.org.uk/ValueSet/UKCore-BloodPressure-CuffSize" } } ] } }
Examples
Cuff Size - An example to illustrate a blood pressure monitoring device with a large cuff.Example UKCore-Extension-CuffSize