SD_MII_ICU_Zentralvenoeser_Blutdruck (Observation)

Bestätigungsrelevanz

Bitte aus dem CpS entnehmenhttps://gematik.de/fhir/isik/CapabilityStatement/ISiKCapabilityStatementVitalSignICUSourceExtendedRolle

Metadaten

Canonicalhttps://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-zentralvenoeser-blutdruck
Statusactive
Version5.0.0-rc
Basishttps://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-monitoring-und-vitaldaten

Inhalt

idΣ0..1string
metaΣ0..1Meta
implicitRulesΣ ?!0..1uri
language0..1codeBinding
text0..1Narrative
contained0..*Resource
extensionI0..*Extension
modifierExtension?! I0..*Extension
identifierS Σ0..*Identifier
basedOnS Σ0..*Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)
partOfΣ0..*Reference(Procedure)
statusS Σ ?!1..1codeBinding
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayΣ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayΣ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
subjectS Σ1..1Reference(Patient)
focusΣ0..*Reference(Resource)
encounterS Σ0..1Reference(Encounter)
effectiveDateTimedateTime
effectivePeriodPeriod
issuedΣ0..1instant
performerS Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)
id0..1string
extensionI0..*Extension
valueS Σ1..1decimal
comparatorΣ ?!0..1codeBinding
unitS Σ1..1string
systemS Σ I1..1uriPattern
codeS Σ1..1code
dataAbsentReasonS I0..1CodeableConceptBinding
interpretationS0..*CodeableConceptBinding
note0..*Annotation
bodySiteS0..1CodeableConceptBindingPattern
methodS0..1CodeableConcept
specimen0..1Reference(Specimen)
deviceS0..1Reference(Device | DeviceMetric)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
lowI0..1SimpleQuantity
highI0..1SimpleQuantity
type0..1CodeableConceptBinding
appliesTo0..*CodeableConcept
age0..1Range
text0..1string
hasMemberΣ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)
derivedFromΣ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
codeS Σ1..1CodeableConcept
valueQuantityQuantity
dataAbsentReasonS I0..1CodeableConceptBinding
interpretationS0..*CodeableConceptBinding
referenceRangeS0..*see (referenceRange)
<StructureDefinition xmlns="http://hl7.org/fhir">
    <id value="sd-mii-icu-zentralvenoeser-blutdruck" />
    <url value="https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-zentralvenoeser-blutdruck" />
    <version value="5.0.0-rc" />
    <name value="SD_MII_ICU_Zentralvenoeser_Blutdruck" />
    <title value="SD MII ICU Zentralvenoeser Blutdruck" />
    <status value="active" />
    <experimental value="false" />
    <date value="2025-04-09" />
    <publisher value="gematik GmbH" />
    <fhirVersion value="4.0.1" />
    <kind value="resource" />
    <abstract value="false" />
    <type value="Observation" />
    <baseDefinition value="https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-monitoring-und-vitaldaten" />
    <derivation value="constraint" />
    <differential>
        <element id="Observation.code.coding">
            <path value="Observation.code.coding" />
            <min value="3" />
        </element>
        <element id="Observation.code.coding:sct">
            <path value="Observation.code.coding" />
            <sliceName value="sct" />
            <min value="1" />
            <max value="1" />
            <patternCoding>
                <system value="http://snomed.info/sct" />
                <code value="71420008" />
            </patternCoding>
        </element>
        <element id="Observation.code.coding:loinc">
            <path value="Observation.code.coding" />
            <sliceName value="loinc" />
            <min value="1" />
            <max value="1" />
            <patternCoding>
                <system value="http://loinc.org" />
                <code value="60985-9" />
            </patternCoding>
        </element>
        <element id="Observation.code.coding:IEEE-11073">
            <path value="Observation.code.coding" />
            <sliceName value="IEEE-11073" />
            <min value="1" />
            <max value="1" />
            <patternCoding>
                <system value="urn:iso:std:iso:11073:10101" />
                <code value="150084" />
            </patternCoding>
        </element>
        <element id="Observation.value[x]">
            <path value="Observation.value[x]" />
            <patternQuantity>
                <unit value="millimeter Mercury column" />
                <system value="http://unitsofmeasure.org" />
                <code value="mm[Hg]" />
            </patternQuantity>
        </element>
        <element id="Observation.value[x].unit">
            <path value="Observation.value[x].unit" />
            <min value="1" />
        </element>
        <element id="Observation.bodySite">
            <path value="Observation.bodySite" />
            <patternCodeableConcept>
                <coding>
                    <system value="http://snomed.info/sct" />
                    <code value="73829009" />
                </coding>
            </patternCodeableConcept>
        </element>
    </differential>
</StructureDefinition>
{
    "resourceType": "StructureDefinition",
    "id": "sd-mii-icu-zentralvenoeser-blutdruck",
    "url": "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-zentralvenoeser-blutdruck",
    "version": "5.0.0-rc",
    "name": "SD_MII_ICU_Zentralvenoeser_Blutdruck",
    "title": "SD MII ICU Zentralvenoeser Blutdruck",
    "status": "active",
    "experimental": false,
    "date": "2025-04-09",
    "publisher": "gematik GmbH",
    "fhirVersion": "4.0.1",
    "kind": "resource",
    "abstract": false,
    "type": "Observation",
    "baseDefinition": "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-monitoring-und-vitaldaten",
    "derivation": "constraint",
    "differential": {
        "element":  [
            {
                "id": "Observation.code.coding",
                "path": "Observation.code.coding",
                "min": 3
            },
            {
                "id": "Observation.code.coding:sct",
                "path": "Observation.code.coding",
                "sliceName": "sct",
                "min": 1,
                "max": "1",
                "patternCoding": {
                    "code": "71420008",
                    "system": "http://snomed.info/sct"
                }
            },
            {
                "id": "Observation.code.coding:loinc",
                "path": "Observation.code.coding",
                "sliceName": "loinc",
                "min": 1,
                "max": "1",
                "patternCoding": {
                    "code": "60985-9",
                    "system": "http://loinc.org"
                }
            },
            {
                "id": "Observation.code.coding:IEEE-11073",
                "path": "Observation.code.coding",
                "sliceName": "IEEE-11073",
                "min": 1,
                "max": "1",
                "patternCoding": {
                    "code": "150084",
                    "system": "urn:iso:std:iso:11073:10101"
                }
            },
            {
                "id": "Observation.value[x]",
                "path": "Observation.value[x]",
                "patternQuantity": {
                    "code": "mm[Hg]",
                    "system": "http://unitsofmeasure.org",
                    "unit": "millimeter Mercury column"
                }
            },
            {
                "id": "Observation.value[x].unit",
                "path": "Observation.value[x].unit",
                "min": 1
            },
            {
                "id": "Observation.bodySite",
                "path": "Observation.bodySite",
                "patternCodeableConcept": {
                    "coding":  [
                        {
                            "code": "73829009",
                            "system": "http://snomed.info/sct"
                        }
                    ]
                }
            }
        ]
    }
}

Constraints/Invarianten

Terminology-Bindings

Anmerkungen zu Must-Support-Feldern

Interaktionen

InteraktionVerbindlichkeit
readSHALL
search-typeSHALL
ParameterTypVerbindlichkeitHinweise
_idtokenSHALL

Beispiel: GET [base]/[Resourcetype]?_id=103270 Anwendungshinweis: Der Parameter _id wird selten alleinstehend verwendet, da sich zum Abruf einer Ressource anhand der id die READ-Interaktion besser anbietet. Der Parameter kann jedoch verwendet werden, um den Abruf einer Ressource bspw. mit einem _include weiterer Ressourcen zu verbinden, z.B. zum Abruf eines Encounters in Verbindung mit dem zugehörigen Patienten: GET [base]/Encounter?_id=103270&_include=Encounter:patient Weitere Details siehe FHIR-Kernspezifikation, Abschnitt Parameters for all resources. Dieser Suchparameter ist für die Umsetzung des IHE PDQm Profils verpflichtend.

_tagtokenSHALL

Beispiel: GET [base]/[Resourcetype]?_tag=https://example.org/codes|needs-review Anwendungshinweis: Weitere Details siehe FHIR-Kernspezifikation, Abschnitt Parameters for all resources sowie Abschnitt Tags.

_countnumberSHALL

Beispiel: GET [base]/[Resourcetype]?_count=100 Anwendungshinweis: Weitere Details siehe FHIR-Kernspezifikation, Abschnitt Page Count.

_hasstringMAY

Beispiel: Suche nach allen Patienten, die eine Observation mit dem Code '1234-5' haben GET [base]/Patient?_has:Observation:patient:code=1234-5 Beispiel: Suche nach allen Encountern, bei denen die Diagnose 'A12.3' gestellt wurde GET [base]/Encounter?_has:Condition:encounter:code=A12.3 Anwendungshinweis: Weitere Details siehe FHIR-Kernspezifikation, Abschnitt Reverse Chaining.

categorytokenSHALL
statustokenSHALL
datedateSHALL
codetokenSHALL
patientreferenceSHALL
subjectreferenceMAY
encounterreferenceSHALL
combo-codetokenSHALL
combo-code-value-quantitycompositeSHALL
component-codetokenSHALL

(Reverse-)Include

Beispiele

Observation
<Observation xmlns="http://hl7.org/fhir">
    <id value="Zentralvenoeser-Blutdruck" />
    <meta>
        <profile value="https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-zentralvenoeser-blutdruck" />
    </meta>
    <status value="final" />
    <category>
        <coding>
            <system value="http://terminology.hl7.org/CodeSystem/observation-category" />
            <code value="vital-signs" />
        </coding>
    </category>
    <code>
        <coding>
            <system value="http://snomed.info/sct" />
            <code value="71420008" />
            <display value="Central venous pressure" />
        </coding>
        <coding>
            <system value="http://loinc.org" />
            <code value="60985-9" />
            <display value="Central venous pressure (CVP)" />
        </coding>
        <coding>
            <system value="urn:iso:std:iso:11073:10101" />
            <code value="150084" />
            <display value="Central venous pressure" />
        </coding>
    </code>
    <subject>
        <reference value="Patient/PatientinMusterfrau" />
    </subject>
    <effectivePeriod>
        <start value="2019-12-23T09:30:10+01:00" />
        <end value="2019-12-23T10:30:10+01:00" />
    </effectivePeriod>
    <valueQuantity>
        <value value="12" />
        <unit value="millimeter Mercury column" />
        <system value="http://unitsofmeasure.org" />
        <code value="mm[Hg]" />
    </valueQuantity>
    <bodySite>
        <coding>
            <system value="http://snomed.info/sct" />
            <code value="73829009" />
            <display value="Right atrial structure" />
        </coding>
    </bodySite>
</Observation>
{
    "resourceType": "Observation",
    "id": "Zentralvenoeser-Blutdruck",
    "meta": {
        "profile":  [
            "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-zentralvenoeser-blutdruck"
        ]
    },
    "category":  [
        {
            "coding":  [
                {
                    "code": "vital-signs",
                    "system": "http://terminology.hl7.org/CodeSystem/observation-category"
                }
            ]
        }
    ],
    "code": {
        "coding":  [
            {
                "code": "71420008",
                "system": "http://snomed.info/sct",
                "display": "Central venous pressure"
            },
            {
                "code": "60985-9",
                "system": "http://loinc.org",
                "display": "Central venous pressure (CVP)"
            },
            {
                "code": "150084",
                "system": "urn:iso:std:iso:11073:10101",
                "display": "Central venous pressure"
            }
        ]
    },
    "valueQuantity": {
        "system": "http://unitsofmeasure.org",
        "code": "mm[Hg]",
        "unit": "millimeter Mercury column",
        "value": 12
    },
    "bodySite": {
        "coding":  [
            {
                "code": "73829009",
                "system": "http://snomed.info/sct",
                "display": "Right atrial structure"
            }
        ]
    },
    "status": "final",
    "subject": {
        "reference": "Patient/PatientinMusterfrau"
    },
    "effectivePeriod": {
        "start": "12/23/2019 08:30:10",
        "end": "12/23/2019 09:30:10"
    }
}