Beispiele
Observation |
id : Systemischer-vaskulaerer-Widerstandsindex |
meta |
profile : https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-systemischer-vaskulaerer-widerstandsindex |
status : final |
category |
coding |
system : http://terminology.hl7.org/CodeSystem/observation-category |
code : vital-signs |
code |
coding |
system : http://snomed.info/sct |
code : 276900001 |
display : Systemic vascular Resistance index |
coding |
system : http://loinc.org |
code : 8837-7 |
display : Systemic vascular Resistance index |
coding |
system : urn:iso:std:iso:11073:10101 |
code : 149760 |
display : Systemic vascular resistance indexed |
subject |
reference : Patient/PatientinMusterfrau |
effective |
start : 2019-12-23T09:30:10+01:00 |
end : 2019-12-23T10:30:10+01:00 |
value |
value : 2000 |
unit : dyne second per centimeter5 and square meter |
system : http://unitsofmeasure.org |
code : dyn.s/cm5/m2 |
<Observation xmlns="http://hl7.org/fhir"> <id value="Systemischer-vaskulaerer-Widerstandsindex" /> <meta> <profile value="https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-systemischer-vaskulaerer-widerstandsindex" /> </meta> <status value="final" /> <category> <coding> <system value="http://terminology.hl7.org/CodeSystem/observation-category" /> <code value="vital-signs" /> </coding> </category> <code> <coding> <system value="http://snomed.info/sct" /> <code value="276900001" /> <display value="Systemic vascular Resistance index" /> </coding> <coding> <system value="http://loinc.org" /> <code value="8837-7" /> <display value="Systemic vascular Resistance index" /> </coding> <coding> <system value="urn:iso:std:iso:11073:10101" /> <code value="149760" /> <display value="Systemic vascular resistance indexed" /> </coding> </code> <subject> <reference value="Patient/PatientinMusterfrau" /> </subject> <effectivePeriod> <start value="2019-12-23T09:30:10+01:00" /> <end value="2019-12-23T10:30:10+01:00" /> </effectivePeriod> <valueQuantity> <value value="2000" /> <unit value="dyne second per centimeter5 and square meter" /> <system value="http://unitsofmeasure.org" /> <code value="dyn.s/cm5/m2" /> </valueQuantity> </Observation>
{ "resourceType": "Observation", "id": "Systemischer-vaskulaerer-Widerstandsindex", "meta": { "profile": [ "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-systemischer-vaskulaerer-widerstandsindex" ] }, "category": [ { "coding": [ { "code": "vital-signs", "system": "http://terminology.hl7.org/CodeSystem/observation-category" } ] } ], "code": { "coding": [ { "code": "276900001", "system": "http://snomed.info/sct", "display": "Systemic vascular Resistance index" }, { "code": "8837-7", "system": "http://loinc.org", "display": "Systemic vascular Resistance index" }, { "code": "149760", "system": "urn:iso:std:iso:11073:10101", "display": "Systemic vascular resistance indexed" } ] }, "valueQuantity": { "system": "http://unitsofmeasure.org", "code": "dyn.s/cm5/m2", "unit": "dyne second per centimeter5 and square meter", "value": 2000 }, "status": "final", "subject": { "reference": "Patient/PatientinMusterfrau" }, "effectivePeriod": { "start": "12/23/2019 08:30:10", "end": "12/23/2019 09:30:10" } }