Bestätigungsrelevanz

Bitte aus dem CpS entnehmenhttps://gematik.de/fhir/isik/CapabilityStatement/ISiKCapabilityStatementVitalSignICUSourceExtendedRolle

Metadaten

Canonicalhttps://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-rechtsventrikulaerer-druck
Statusactive
Version5.0.0-rc
Basishttps://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch

Inhalt

idΣ0..1string
metaΣ0..1Meta
implicitRulesΣ ?!0..1uri
language0..1codeBinding
text0..1Narrative
contained0..*Resource
extensionI0..*Extension
modifierExtension?! I0..*Extension
identifierS Σ0..*Identifier
basedOnΣ0..1Reference(CarePlan | DeviceRequest | ImmunizationRecommendation | MedicationRequest | NutritionOrder | ServiceRequest)
partOfΣ0..*Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy)
statusS Σ ?!1..1codeBinding
categoryS0..*CodeableConceptBindingPattern
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ1..1uri
versionΣ0..1string
codeS Σ1..1code
displayS Σ0..1string
userSelectedΣ0..1boolean
sct-genericS Σ1..1CodingPattern
sctS Σ1..1CodingPattern
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
subjectS Σ0..1Reference(Patient | Group | Device | Location)
focusΣ0..*Reference(Resource)
encounterS Σ0..1Reference(Encounter)
effectiveDateTimedateTime
effectivePeriodPeriod
effectiveTimingTiming
effectiveInstantinstant
issuedΣ0..1instant
performerS Σ0..*Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson)
dataAbsentReasonS I0..0CodeableConceptBinding
interpretationS0..*CodeableConceptBinding
note0..*Annotation
bodySiteS0..1CodeableConceptBindingPattern
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ0..1uri
versionΣ0..1string
codeS Σ0..1code
displayΣ0..1string
userSelectedΣ0..1boolean
textΣ0..1string
specimen0..1Reference(Specimen)
deviceS0..1Reference(Device | DeviceMetric)
hasMemberΣ0..*Reference(Observation | QuestionnaireResponse | MolecularSequence)
derivedFromΣ0..*Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
codeS Σ1..1CodeableConcept
valueQuantityQuantity
valueCodeableConceptCodeableConcept
valueStringstring
valueBooleanboolean
valueIntegerinteger
valueRangeRange
valueRatioRatio
valueSampledDataSampledData
valueTimetime
valueDateTimedateTime
valuePeriodPeriod
dataAbsentReasonI0..1CodeableConceptBinding
interpretation0..*CodeableConceptBinding
referenceRange0..*see (referenceRange)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
loinc-detailedS Σ0..1CodingPattern
sct-detailedS Σ0..*CodingPattern
textΣ0..1string
id0..1string
extensionI0..*Extension
valueS Σ1..1decimal
comparatorΣ ?!0..1codeBinding
unitS Σ1..1string
systemS Σ I1..1uri
codeS Σ1..1code
dataAbsentReasonS I0..1CodeableConceptBinding
interpretation0..*CodeableConceptBinding
referenceRange0..*see (referenceRange)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
loinc-detailedS Σ0..1CodingPattern
sct-detailedS Σ0..*CodingPattern
textΣ0..1string
id0..1string
extensionI0..*Extension
valueS Σ1..1decimal
comparatorΣ ?!0..1codeBinding
unitS Σ1..1string
systemS Σ I1..1uri
codeS Σ1..1code
dataAbsentReasonS I0..1CodeableConceptBinding
interpretation0..*CodeableConceptBinding
referenceRange0..*see (referenceRange)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
id0..1string
extensionI0..*Extension
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
id0..1string
extensionI0..*Extension
systemS Σ1..1uriPattern
versionΣ0..1string
codeS Σ1..1codePattern
displayS Σ0..1string
userSelectedΣ0..1boolean
loinc-detailedS Σ0..1CodingPattern
textΣ0..1string
id0..1string
extensionI0..*Extension
valueS Σ1..1decimal
comparatorΣ ?!0..1codeBinding
unitS Σ1..1string
systemS Σ I1..1uri
codeS Σ1..1code
dataAbsentReasonI0..1CodeableConceptBinding
interpretation0..*CodeableConceptBinding
referenceRange0..*see (referenceRange)
<StructureDefinition xmlns="http://hl7.org/fhir">
    <id value="sd-mii-icu-rechtsventrikulaerer-druck" />
    <url value="https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-rechtsventrikulaerer-druck" />
    <version value="5.0.0-rc" />
    <name value="SD_MII_ICU_Rechtsventrikulaerer_Druck" />
    <title value="SD MII ICU Rechtsventrikulaerer Druck" />
    <status value="active" />
    <experimental value="false" />
    <date value="2025-04-09" />
    <publisher value="gematik GmbH" />
    <fhirVersion value="4.0.1" />
    <kind value="resource" />
    <abstract value="false" />
    <type value="Observation" />
    <baseDefinition value="https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch" />
    <derivation value="constraint" />
    <differential>
        <element id="Observation.category">
            <path value="Observation.category" />
            <patternCodeableConcept>
                <coding>
                    <system value="http://terminology.hl7.org/CodeSystem/observation-category" />
                    <code value="vital-signs" />
                </coding>
            </patternCodeableConcept>
        </element>
        <element id="Observation.code.coding">
            <path value="Observation.code.coding" />
            <min value="3" />
            <max value="3" />
        </element>
        <element id="Observation.code.coding:sct">
            <path value="Observation.code.coding" />
            <sliceName value="sct" />
            <patternCoding>
                <system value="http://snomed.info/sct" />
                <code value="276756009" />
            </patternCoding>
        </element>
        <element id="Observation.code.coding:IEEE-11073">
            <path value="Observation.code.coding" />
            <sliceName value="IEEE-11073" />
            <min value="1" />
            <max value="1" />
            <patternCoding>
                <system value="urn:iso:std:iso:11073:10101" />
                <code value="150104" />
            </patternCoding>
        </element>
        <element id="Observation.bodySite">
            <path value="Observation.bodySite" />
            <patternCodeableConcept>
                <coding>
                    <system value="http://snomed.info/sct" />
                    <code value="53085002" />
                </coding>
            </patternCodeableConcept>
        </element>
        <element id="Observation.component:SystolicBP">
            <path value="Observation.component" />
            <sliceName value="SystolicBP" />
        </element>
        <element id="Observation.component:SystolicBP.code.coding:IEEE-11073">
            <path value="Observation.component.code.coding" />
            <sliceName value="IEEE-11073" />
            <patternCoding>
                <system value="urn:iso:std:iso:11073:10101" />
                <code value="150105" />
            </patternCoding>
        </element>
        <element id="Observation.component:SystolicBP.code.coding:loinc-detailed">
            <path value="Observation.component.code.coding" />
            <sliceName value="loinc-detailed" />
            <min value="0" />
            <max value="1" />
            <patternCoding>
                <system value="http://loinc.org" />
                <code value="8432-7" />
            </patternCoding>
        </element>
        <element id="Observation.component:SystolicBP.code.coding:sct-detailed">
            <path value="Observation.component.code.coding" />
            <sliceName value="sct-detailed" />
            <min value="0" />
            <max value="*" />
            <patternCoding>
                <system value="http://snomed.info/sct" />
                <code value="276772001" />
            </patternCoding>
        </element>
        <element id="Observation.component:DiastolicBP">
            <path value="Observation.component" />
            <sliceName value="DiastolicBP" />
        </element>
        <element id="Observation.component:DiastolicBP.code.coding:IEEE-11073">
            <path value="Observation.component.code.coding" />
            <sliceName value="IEEE-11073" />
            <patternCoding>
                <system value="urn:iso:std:iso:11073:10101" />
                <code value="150106" />
            </patternCoding>
        </element>
        <element id="Observation.component:DiastolicBP.code.coding:loinc-detailed">
            <path value="Observation.component.code.coding" />
            <sliceName value="loinc-detailed" />
            <min value="0" />
            <max value="1" />
            <patternCoding>
                <system value="http://loinc.org" />
                <code value="8377-4" />
            </patternCoding>
        </element>
        <element id="Observation.component:DiastolicBP.code.coding:sct-detailed">
            <path value="Observation.component.code.coding" />
            <sliceName value="sct-detailed" />
            <min value="0" />
            <max value="*" />
            <patternCoding>
                <system value="http://snomed.info/sct" />
                <code value="276773006" />
            </patternCoding>
        </element>
        <element id="Observation.component:meanBP">
            <path value="Observation.component" />
            <sliceName value="meanBP" />
        </element>
        <element id="Observation.component:meanBP.code.coding:IEEE-11073">
            <path value="Observation.component.code.coding" />
            <sliceName value="IEEE-11073" />
            <patternCoding>
                <system value="urn:iso:std:iso:11073:10101" />
                <code value="150107" />
            </patternCoding>
        </element>
        <element id="Observation.component:meanBP.code.coding:loinc-detailed">
            <path value="Observation.component.code.coding" />
            <sliceName value="loinc-detailed" />
            <min value="0" />
            <max value="1" />
            <patternCoding>
                <system value="http://loinc.org" />
                <code value="8406-1" />
            </patternCoding>
        </element>
    </differential>
</StructureDefinition>
{
    "resourceType": "StructureDefinition",
    "id": "sd-mii-icu-rechtsventrikulaerer-druck",
    "url": "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-rechtsventrikulaerer-druck",
    "version": "5.0.0-rc",
    "name": "SD_MII_ICU_Rechtsventrikulaerer_Druck",
    "title": "SD MII ICU Rechtsventrikulaerer Druck",
    "status": "active",
    "experimental": false,
    "date": "2025-04-09",
    "publisher": "gematik GmbH",
    "fhirVersion": "4.0.1",
    "kind": "resource",
    "abstract": false,
    "type": "Observation",
    "baseDefinition": "https://gematik.de/fhir/isik/StructureDefinition/sd-mii-icu-sonstige-pulsatile-druecke-generisch",
    "derivation": "constraint",
    "differential": {
        "element":  [
            {
                "id": "Observation.category",
                "path": "Observation.category",
                "patternCodeableConcept": {
                    "coding":  [
                        {
                            "code": "vital-signs",
                            "system": "http://terminology.hl7.org/CodeSystem/observation-category"
                        }
                    ]
                }
            },
            {
                "id": "Observation.code.coding",
                "path": "Observation.code.coding",
                "min": 3,
                "max": "3"
            },
            {
                "id": "Observation.code.coding:sct",
                "path": "Observation.code.coding",
                "sliceName": "sct",
                "patternCoding": {
                    "code": "276756009",
                    "system": "http://snomed.info/sct"
                }
            },
            {
                "id": "Observation.code.coding:IEEE-11073",
                "path": "Observation.code.coding",
                "sliceName": "IEEE-11073",
                "min": 1,
                "max": "1",
                "patternCoding": {
                    "code": "150104",
                    "system": "urn:iso:std:iso:11073:10101"
                }
            },
            {
                "id": "Observation.bodySite",
                "path": "Observation.bodySite",
                "patternCodeableConcept": {
                    "coding":  [
                        {
                            "code": "53085002",
                            "system": "http://snomed.info/sct"
                        }
                    ]
                }
            },
            {
                "id": "Observation.component:SystolicBP",
                "path": "Observation.component",
                "sliceName": "SystolicBP"
            },
            {
                "id": "Observation.component:SystolicBP.code.coding:IEEE-11073",
                "path": "Observation.component.code.coding",
                "sliceName": "IEEE-11073",
                "patternCoding": {
                    "code": "150105",
                    "system": "urn:iso:std:iso:11073:10101"
                }
            },
            {
                "id": "Observation.component:SystolicBP.code.coding:loinc-detailed",
                "path": "Observation.component.code.coding",
                "sliceName": "loinc-detailed",
                "min": 0,
                "max": "1",
                "patternCoding": {
                    "code": "8432-7",
                    "system": "http://loinc.org"
                }
            },
            {
                "id": "Observation.component:SystolicBP.code.coding:sct-detailed",
                "path": "Observation.component.code.coding",
                "sliceName": "sct-detailed",
                "min": 0,
                "max": "*",
                "patternCoding": {
                    "code": "276772001",
                    "system": "http://snomed.info/sct"
                }
            },
            {
                "id": "Observation.component:DiastolicBP",
                "path": "Observation.component",
                "sliceName": "DiastolicBP"
            },
            {
                "id": "Observation.component:DiastolicBP.code.coding:IEEE-11073",
                "path": "Observation.component.code.coding",
                "sliceName": "IEEE-11073",
                "patternCoding": {
                    "code": "150106",
                    "system": "urn:iso:std:iso:11073:10101"
                }
            },
            {
                "id": "Observation.component:DiastolicBP.code.coding:loinc-detailed",
                "path": "Observation.component.code.coding",
                "sliceName": "loinc-detailed",
                "min": 0,
                "max": "1",
                "patternCoding": {
                    "code": "8377-4",
                    "system": "http://loinc.org"
                }
            },
            {
                "id": "Observation.component:DiastolicBP.code.coding:sct-detailed",
                "path": "Observation.component.code.coding",
                "sliceName": "sct-detailed",
                "min": 0,
                "max": "*",
                "patternCoding": {
                    "code": "276773006",
                    "system": "http://snomed.info/sct"
                }
            },
            {
                "id": "Observation.component:meanBP",
                "path": "Observation.component",
                "sliceName": "meanBP"
            },
            {
                "id": "Observation.component:meanBP.code.coding:IEEE-11073",
                "path": "Observation.component.code.coding",
                "sliceName": "IEEE-11073",
                "patternCoding": {
                    "code": "150107",
                    "system": "urn:iso:std:iso:11073:10101"
                }
            },
            {
                "id": "Observation.component:meanBP.code.coding:loinc-detailed",
                "path": "Observation.component.code.coding",
                "sliceName": "loinc-detailed",
                "min": 0,
                "max": "1",
                "patternCoding": {
                    "code": "8406-1",
                    "system": "http://loinc.org"
                }
            }
        ]
    }
}

Constraints/Invarianten

Terminology-Bindings