DataStandardsWales-DiagnosticReport-Lab
The Data Standards Wales DiagnosticReport-Lab profile (based on DiagonsticReport) is used to represent Laboratory Result Reports (e.g. Clinical Chemistry, Haematology, Microbiology, etc.). The results of such tests are typically contained within nested panels of results (such as a Full Blood Count or Liver Function Test panel) which are represented by Observation resources that contain references to other nested Observations.
The purpose of this profile is to provide a set of guidelines and minimum standards to allow DiagnosticReport resources to be used to record, search, and fetch laboratory results associated with a patient in a consistent and interoperable manner.
A direct link to the Data Standards Wales asset can be accessed here - Data Standards Wales Diagnostic Report - Lab
The diagram below shows the typical structure of a Laboratory Result Report.
Formal Views of Profile Content
- Snapshot View
- Differential View
- Hybrid View
- Examples
DiagnosticReport | I | DiagnosticReport | There are no (further) constraints on this element Element IdDiagnosticReport A Diagnostic report - a combination of request information, atomic results, images, interpretation, as well as formatted reports Alternate namesReport, Test, Result, Results, Labs, Laboratory DefinitionThe findings and interpretation of diagnostic tests performed on patients, groups of patients, devices, and locations, and/or specimens derived from these. The report includes clinical context such as requesting and provider information, and some mix of atomic results, images, textual and coded interpretations, and formatted representation of diagnostic reports. This is intended to capture a single report and is not suitable for use in displaying summary information that covers multiple reports. For example, this resource has not been designed for laboratory cumulative reporting formats nor detailed structured reports for sequencing.
| |
identifier | S Σ | 0..* | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.identifier Business identifier for report Alternate namesReportID, Filler ID, Placer ID DefinitionIdentifiers assigned to this report by the performer or other systems. Need to know what identifier to use when making queries about this report from the source laboratory, and for linking to the report outside FHIR context. Usually assigned by the Information System of the diagnostic service provider (filler id).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
basedOn | I | 0..* | Reference(ImmunizationRecommendation | NutritionOrder | UK Core ServiceRequest | UK Core CarePlan | UK Core MedicationRequest) | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn What was requested Alternate namesRequest DefinitionDetails concerning a service requested. This allows tracing of authorization for the report and tracking whether proposals/recommendations were acted upon. Note: Usually there is one test request for each result, however in some circumstances multiple test requests may be represented using a single test result resource. Note that there are also cases where one request leads to multiple reports. Reference(ImmunizationRecommendation | NutritionOrder | UK Core ServiceRequest | UK Core CarePlan | UK Core MedicationRequest) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
status | S Σ ?! | 1..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.status registered | partial | preliminary | final + DefinitionThe status of the diagnostic report. Diagnostic services routinely issue provisional/incomplete reports, and sometimes withdraw previously released reports. Note that FHIR strings SHALL NOT exceed 1MB in size The status of the diagnostic report. DiagnosticReportStatus (required)Constraints
|
category | Σ | 1..* | CodeableConcept | There are no (further) constraints on this element Element IdDiagnosticReport.category Service category Alternate namesDepartment, Sub-department, Service, Discipline DefinitionA code that classifies the clinical discipline, department or diagnostic service that created the report (e.g. cardiology, biochemistry, hematology, MRI). This is used for searching, sorting and display purposes. Multiple categories are allowed using various categorization schemes. The level of granularity is defined by the category concepts in the value set. More fine-grained filtering can be performed using the metadata and/or terminology hierarchy in DiagnosticReport.code. Codes for diagnostic service sections. DiagnosticServiceSectionCodes (example)Constraints
|
coding | Σ | 1..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
snomedCT | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
laboratory | S Σ | 1..1 | CodingFixed Value | Element IdDiagnosticReport.category.coding:laboratory Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
{ "system": "http://terminology.hl7.org/CodeSystem/v2-0074", "code": "LAB", "display": "Laboratory" }
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.category.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
code | S Σ | 1..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.code Name/Code for this diagnostic report Alternate namesType DefinitionA code or name that describes this diagnostic report. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Codes that describe Diagnostic Reports. LOINCDiagnosticReportCodes (preferred)Constraints
|
coding | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
snomedCT | Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. A code from the SNOMED UK Clinical Terminology coding system UKCoreReportCodeSnCT (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.code.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
subject | S Σ I | 1..1 | Reference(Data Standards Wales Patient) | Element IdDiagnosticReport.subject The subject of the report - which is always a patient for Laboratory Reports Alternate namesPatient DefinitionThe subject of the report - which is always a patient for Laboratory Reports. SHALL know the subject context. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(Data Standards Wales Patient) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.subject.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.subject.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.subject.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
encounter | S Σ I | 0..1 | Reference(Data Standards Wales Encounter) | Element IdDiagnosticReport.encounter Health care event when test ordered Alternate namesContext DefinitionThe healthcare event (e.g. a patient and healthcare provider interaction) which this DiagnosticReport is about. Links the request to the Encounter context. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests). Reference(Data Standards Wales Encounter) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
effective[x] | S Σ | 0..1 | There are no (further) constraints on this element Element IdDiagnosticReport.effective[x] Clinically relevant time/time-period for report Alternate namesObservation time, Effective Time, Occurrence DefinitionThe time or time-period the observed values are related to. When the subject of the report is a patient, this is usually either the time of the procedure or of specimen collection(s), but very often the source of the date/time is not known, only the date/time itself. Need to know where in the patient history to file/present this report. If the diagnostic procedure was performed on the patient, this is the time it was performed. If there are specimens, the diagnostically relevant time can be derived from the specimen collection times, but the specimen information is not always available, and the exact relationship between the specimens and the diagnostically relevant time is not always automatic.
| |
effectiveDateTime | dateTime | There are no (further) constraints on this element Data Type | ||
effectivePeriod | Period | There are no (further) constraints on this element Data Type | ||
issued | S Σ | 0..1 | instant | There are no (further) constraints on this element Element IdDiagnosticReport.issued DateTime this version was made Alternate namesDate published, Date Issued, Date Verified DefinitionThe date and time that this version of the report was made available to providers, typically after the report was reviewed and verified. Clinicians need to be able to check the date that the report was released. May be different from the update time of the resource itself, because that is the status of the record (potentially a secondary copy), not the actual release time of the report.
|
performer | S Σ I | 0..* | Reference(UK Core CareTeam | Data Standards Wales Practitioner | Data Standards Wales Practitioner Role | Data Standards Wales Organization) | Element IdDiagnosticReport.performer Responsible Diagnostic Service Alternate namesLaboratory, Service, Practitioner, Department, Company, Authorized by, Director DefinitionThe diagnostic service that is responsible for issuing the report. Need to know whom to contact if there are queries about the results. Also may need to track the source of reports for secondary data analysis. This is not necessarily the source of the atomic data items or the entity that interpreted the results. It is the entity that takes responsibility for the clinical report. Reference(UK Core CareTeam | Data Standards Wales Practitioner | Data Standards Wales Practitioner Role | Data Standards Wales Organization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.performer.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.performer.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.performer.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
resultsInterpreter | Σ I | 0..* | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Organization | UK Core CareTeam) | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter Primary result interpreter Alternate namesAnalyzed by, Reported by DefinitionThe practitioner or organization that is responsible for the report's conclusions and interpretations. Need to know whom to contact if there are queries about the results. Also may need to track the source of reports for secondary data analysis. Might not be the same entity that takes responsibility for the clinical report. Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Organization | UK Core CareTeam) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
specimen | I | 0..* | Reference(Specimen) | There are no (further) constraints on this element Element IdDiagnosticReport.specimen Specimens this report is based on DefinitionDetails about the specimens on which this diagnostic report is based. Need to be able to report information about the collected specimens on which the report is based. If the specimen is sufficiently specified with a code in the test result name, then this additional data may be redundant. If there are multiple specimens, these may be represented per observation or group.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
result | S I | 0..* | Reference(Data Standards Wales Observation - Lab | Data Standards Wales Observation) | Element IdDiagnosticReport.result Observations Alternate namesData, Atomic Value, Result, Atomic result, Data, Test, Analyte, Battery, Organizer DefinitionObservations that are part of this diagnostic report. Need to support individual results, or groups of results, where the result grouping is arbitrary, but meaningful. Observations can contain observations. Reference(Data Standards Wales Observation - Lab | Data Standards Wales Observation) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.result.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.result.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.result.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
imagingStudy | I | 0..* | Reference(ImagingStudy) | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy Reference to full details of imaging associated with the diagnostic report DefinitionOne or more links to full details of any imaging performed during the diagnostic investigation. Typically, this is imaging performed by DICOM enabled modalities, but this is not required. A fully enabled PACS viewer can use this information to provide views of the source images. ImagingStudy and the image element are somewhat overlapping - typically, the list of image references in the image element will also be found in one of the imaging study resources. However, each caters to different types of displays for different types of purposes. Neither, either, or both may be provided.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
media | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDiagnosticReport.media Key images associated with this report Alternate namesDICOM, Slides, Scans DefinitionA list of key images associated with this report. The images are generally created during the diagnostic process, and may be directly of the patient, or of treated specimens (i.e. slides of interest). Many diagnostic services include images in the report as part of their service.
|
comment | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.comment Comment about the image (e.g. explanation) DefinitionA comment about the image. Typically, this is used to provide an explanation for why the image is included, or to draw the viewer's attention to important features. The provider of the report should make a comment about each image included in the report. The comment should be displayed with the image. It would be common for the report to include additional discussion of the image contents in other sections such as the conclusion.
| |
link | Σ I | 1..1 | Reference(Media) | There are no (further) constraints on this element Element IdDiagnosticReport.media.link Reference to the image source DefinitionReference to the image source. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
conclusion | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusion Clinical conclusion (interpretation) of test results Alternate namesReport DefinitionConcise and clinically contextualized summary conclusion (interpretation/impression) of the diagnostic report. Need to be able to provide a conclusion that is not lost among the basic result data. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
conclusionCode | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode Codes for the clinical conclusion of test results DefinitionOne or more codes that represent the summary conclusion (interpretation/impression) of the diagnostic report. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Diagnosis codes provided as adjuncts to the report. SNOMEDCTClinicalFindings (example)Constraints
| |
coding | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
snomedCT | Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. A code from the SNOMED UK Clinical Terminology coding system UKCoreFindingCode (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
presentedForm | I | 0..* | Attachment | There are no (further) constraints on this element Element IdDiagnosticReport.presentedForm Entire report as issued DefinitionRich text representation of the entire result as issued by the diagnostic service. Multiple formats are allowed but they SHALL be semantically equivalent. Gives laboratory the ability to provide its own fully formatted report for clinical fidelity. "application/pdf" is recommended as the most reliable and interoperable in this context.
|
DiagnosticReport | I | DiagnosticReport | There are no (further) constraints on this element Element IdDiagnosticReport A Diagnostic report - a combination of request information, atomic results, images, interpretation, as well as formatted reports Alternate namesReport, Test, Result, Results, Labs, Laboratory DefinitionThe findings and interpretation of diagnostic tests performed on patients, groups of patients, devices, and locations, and/or specimens derived from these. The report includes clinical context such as requesting and provider information, and some mix of atomic results, images, textual and coded interpretations, and formatted representation of diagnostic reports. This is intended to capture a single report and is not suitable for use in displaying summary information that covers multiple reports. For example, this resource has not been designed for laboratory cumulative reporting formats nor detailed structured reports for sequencing.
| |
identifier | S Σ | 0..* | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.identifier Business identifier for report Alternate namesReportID, Filler ID, Placer ID DefinitionIdentifiers assigned to this report by the performer or other systems. Need to know what identifier to use when making queries about this report from the source laboratory, and for linking to the report outside FHIR context. Usually assigned by the Information System of the diagnostic service provider (filler id).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
basedOn | I | 0..* | Reference(ImmunizationRecommendation | NutritionOrder | UK Core ServiceRequest | UK Core CarePlan | UK Core MedicationRequest) | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn What was requested Alternate namesRequest DefinitionDetails concerning a service requested. This allows tracing of authorization for the report and tracking whether proposals/recommendations were acted upon. Note: Usually there is one test request for each result, however in some circumstances multiple test requests may be represented using a single test result resource. Note that there are also cases where one request leads to multiple reports. Reference(ImmunizationRecommendation | NutritionOrder | UK Core ServiceRequest | UK Core CarePlan | UK Core MedicationRequest) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
status | S Σ ?! | 1..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.status registered | partial | preliminary | final + DefinitionThe status of the diagnostic report. Diagnostic services routinely issue provisional/incomplete reports, and sometimes withdraw previously released reports. Note that FHIR strings SHALL NOT exceed 1MB in size The status of the diagnostic report. DiagnosticReportStatus (required)Constraints
|
category | Σ | 1..* | CodeableConcept | There are no (further) constraints on this element Element IdDiagnosticReport.category Service category Alternate namesDepartment, Sub-department, Service, Discipline DefinitionA code that classifies the clinical discipline, department or diagnostic service that created the report (e.g. cardiology, biochemistry, hematology, MRI). This is used for searching, sorting and display purposes. Multiple categories are allowed using various categorization schemes. The level of granularity is defined by the category concepts in the value set. More fine-grained filtering can be performed using the metadata and/or terminology hierarchy in DiagnosticReport.code. Codes for diagnostic service sections. DiagnosticServiceSectionCodes (example)Constraints
|
coding | Σ | 1..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
snomedCT | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
laboratory | S Σ | 1..1 | CodingFixed Value | Element IdDiagnosticReport.category.coding:laboratory Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
{ "system": "http://terminology.hl7.org/CodeSystem/v2-0074", "code": "LAB", "display": "Laboratory" }
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.category.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
code | S Σ | 1..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.code Name/Code for this diagnostic report Alternate namesType DefinitionA code or name that describes this diagnostic report. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Codes that describe Diagnostic Reports. LOINCDiagnosticReportCodes (preferred)Constraints
|
coding | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
snomedCT | Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. A code from the SNOMED UK Clinical Terminology coding system UKCoreReportCodeSnCT (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.code.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
subject | S Σ I | 1..1 | Reference(Data Standards Wales Patient) | Element IdDiagnosticReport.subject The subject of the report - which is always a patient for Laboratory Reports Alternate namesPatient DefinitionThe subject of the report - which is always a patient for Laboratory Reports. SHALL know the subject context. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(Data Standards Wales Patient) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.subject.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.subject.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.subject.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
encounter | S Σ I | 0..1 | Reference(Data Standards Wales Encounter) | Element IdDiagnosticReport.encounter Health care event when test ordered Alternate namesContext DefinitionThe healthcare event (e.g. a patient and healthcare provider interaction) which this DiagnosticReport is about. Links the request to the Encounter context. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests). Reference(Data Standards Wales Encounter) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
effective[x] | S Σ | 0..1 | There are no (further) constraints on this element Element IdDiagnosticReport.effective[x] Clinically relevant time/time-period for report Alternate namesObservation time, Effective Time, Occurrence DefinitionThe time or time-period the observed values are related to. When the subject of the report is a patient, this is usually either the time of the procedure or of specimen collection(s), but very often the source of the date/time is not known, only the date/time itself. Need to know where in the patient history to file/present this report. If the diagnostic procedure was performed on the patient, this is the time it was performed. If there are specimens, the diagnostically relevant time can be derived from the specimen collection times, but the specimen information is not always available, and the exact relationship between the specimens and the diagnostically relevant time is not always automatic.
| |
effectiveDateTime | dateTime | There are no (further) constraints on this element Data Type | ||
effectivePeriod | Period | There are no (further) constraints on this element Data Type | ||
issued | S Σ | 0..1 | instant | There are no (further) constraints on this element Element IdDiagnosticReport.issued DateTime this version was made Alternate namesDate published, Date Issued, Date Verified DefinitionThe date and time that this version of the report was made available to providers, typically after the report was reviewed and verified. Clinicians need to be able to check the date that the report was released. May be different from the update time of the resource itself, because that is the status of the record (potentially a secondary copy), not the actual release time of the report.
|
performer | S Σ I | 0..* | Reference(UK Core CareTeam | Data Standards Wales Practitioner | Data Standards Wales Practitioner Role | Data Standards Wales Organization) | Element IdDiagnosticReport.performer Responsible Diagnostic Service Alternate namesLaboratory, Service, Practitioner, Department, Company, Authorized by, Director DefinitionThe diagnostic service that is responsible for issuing the report. Need to know whom to contact if there are queries about the results. Also may need to track the source of reports for secondary data analysis. This is not necessarily the source of the atomic data items or the entity that interpreted the results. It is the entity that takes responsibility for the clinical report. Reference(UK Core CareTeam | Data Standards Wales Practitioner | Data Standards Wales Practitioner Role | Data Standards Wales Organization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.performer.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.performer.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.performer.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
resultsInterpreter | Σ I | 0..* | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Organization | UK Core CareTeam) | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter Primary result interpreter Alternate namesAnalyzed by, Reported by DefinitionThe practitioner or organization that is responsible for the report's conclusions and interpretations. Need to know whom to contact if there are queries about the results. Also may need to track the source of reports for secondary data analysis. Might not be the same entity that takes responsibility for the clinical report. Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Organization | UK Core CareTeam) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
specimen | I | 0..* | Reference(Specimen) | There are no (further) constraints on this element Element IdDiagnosticReport.specimen Specimens this report is based on DefinitionDetails about the specimens on which this diagnostic report is based. Need to be able to report information about the collected specimens on which the report is based. If the specimen is sufficiently specified with a code in the test result name, then this additional data may be redundant. If there are multiple specimens, these may be represented per observation or group.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
result | S I | 0..* | Reference(Data Standards Wales Observation - Lab | Data Standards Wales Observation) | Element IdDiagnosticReport.result Observations Alternate namesData, Atomic Value, Result, Atomic result, Data, Test, Analyte, Battery, Organizer DefinitionObservations that are part of this diagnostic report. Need to support individual results, or groups of results, where the result grouping is arbitrary, but meaningful. Observations can contain observations. Reference(Data Standards Wales Observation - Lab | Data Standards Wales Observation) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.result.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.result.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.result.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
imagingStudy | I | 0..* | Reference(ImagingStudy) | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy Reference to full details of imaging associated with the diagnostic report DefinitionOne or more links to full details of any imaging performed during the diagnostic investigation. Typically, this is imaging performed by DICOM enabled modalities, but this is not required. A fully enabled PACS viewer can use this information to provide views of the source images. ImagingStudy and the image element are somewhat overlapping - typically, the list of image references in the image element will also be found in one of the imaging study resources. However, each caters to different types of displays for different types of purposes. Neither, either, or both may be provided.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
media | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDiagnosticReport.media Key images associated with this report Alternate namesDICOM, Slides, Scans DefinitionA list of key images associated with this report. The images are generally created during the diagnostic process, and may be directly of the patient, or of treated specimens (i.e. slides of interest). Many diagnostic services include images in the report as part of their service.
|
comment | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.comment Comment about the image (e.g. explanation) DefinitionA comment about the image. Typically, this is used to provide an explanation for why the image is included, or to draw the viewer's attention to important features. The provider of the report should make a comment about each image included in the report. The comment should be displayed with the image. It would be common for the report to include additional discussion of the image contents in other sections such as the conclusion.
| |
link | Σ I | 1..1 | Reference(Media) | There are no (further) constraints on this element Element IdDiagnosticReport.media.link Reference to the image source DefinitionReference to the image source. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
conclusion | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusion Clinical conclusion (interpretation) of test results Alternate namesReport DefinitionConcise and clinically contextualized summary conclusion (interpretation/impression) of the diagnostic report. Need to be able to provide a conclusion that is not lost among the basic result data. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
conclusionCode | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode Codes for the clinical conclusion of test results DefinitionOne or more codes that represent the summary conclusion (interpretation/impression) of the diagnostic report. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Diagnosis codes provided as adjuncts to the report. SNOMEDCTClinicalFindings (example)Constraints
| |
coding | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
snomedCT | Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. A code from the SNOMED UK Clinical Terminology coding system UKCoreFindingCode (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
presentedForm | I | 0..* | Attachment | There are no (further) constraints on this element Element IdDiagnosticReport.presentedForm Entire report as issued DefinitionRich text representation of the entire result as issued by the diagnostic service. Multiple formats are allowed but they SHALL be semantically equivalent. Gives laboratory the ability to provide its own fully formatted report for clinical fidelity. "application/pdf" is recommended as the most reliable and interoperable in this context.
|
DiagnosticReport | I | DiagnosticReport | There are no (further) constraints on this element Element IdDiagnosticReport A Diagnostic report - a combination of request information, atomic results, images, interpretation, as well as formatted reports Alternate namesReport, Test, Result, Results, Labs, Laboratory DefinitionThe findings and interpretation of diagnostic tests performed on patients, groups of patients, devices, and locations, and/or specimens derived from these. The report includes clinical context such as requesting and provider information, and some mix of atomic results, images, textual and coded interpretations, and formatted representation of diagnostic reports. This is intended to capture a single report and is not suitable for use in displaying summary information that covers multiple reports. For example, this resource has not been designed for laboratory cumulative reporting formats nor detailed structured reports for sequencing.
| |
identifier | S Σ | 0..* | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.identifier Business identifier for report Alternate namesReportID, Filler ID, Placer ID DefinitionIdentifiers assigned to this report by the performer or other systems. Need to know what identifier to use when making queries about this report from the source laboratory, and for linking to the report outside FHIR context. Usually assigned by the Information System of the diagnostic service provider (filler id).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
basedOn | I | 0..* | Reference(ImmunizationRecommendation | NutritionOrder | UK Core ServiceRequest | UK Core CarePlan | UK Core MedicationRequest) | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn What was requested Alternate namesRequest DefinitionDetails concerning a service requested. This allows tracing of authorization for the report and tracking whether proposals/recommendations were acted upon. Note: Usually there is one test request for each result, however in some circumstances multiple test requests may be represented using a single test result resource. Note that there are also cases where one request leads to multiple reports. Reference(ImmunizationRecommendation | NutritionOrder | UK Core ServiceRequest | UK Core CarePlan | UK Core MedicationRequest) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.basedOn.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
status | S Σ ?! | 1..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.status registered | partial | preliminary | final + DefinitionThe status of the diagnostic report. Diagnostic services routinely issue provisional/incomplete reports, and sometimes withdraw previously released reports. Note that FHIR strings SHALL NOT exceed 1MB in size The status of the diagnostic report. DiagnosticReportStatus (required)Constraints
|
category | Σ | 1..* | CodeableConcept | There are no (further) constraints on this element Element IdDiagnosticReport.category Service category Alternate namesDepartment, Sub-department, Service, Discipline DefinitionA code that classifies the clinical discipline, department or diagnostic service that created the report (e.g. cardiology, biochemistry, hematology, MRI). This is used for searching, sorting and display purposes. Multiple categories are allowed using various categorization schemes. The level of granularity is defined by the category concepts in the value set. More fine-grained filtering can be performed using the metadata and/or terminology hierarchy in DiagnosticReport.code. Codes for diagnostic service sections. DiagnosticServiceSectionCodes (example)Constraints
|
coding | Σ | 1..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
snomedCT | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdDiagnosticReport.category.coding:snomedCT.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
laboratory | S Σ | 1..1 | CodingFixed Value | Element IdDiagnosticReport.category.coding:laboratory Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
{ "system": "http://terminology.hl7.org/CodeSystem/v2-0074", "code": "LAB", "display": "Laboratory" }
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.category.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
code | S Σ | 1..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.code Name/Code for this diagnostic report Alternate namesType DefinitionA code or name that describes this diagnostic report. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Codes that describe Diagnostic Reports. LOINCDiagnosticReportCodes (preferred)Constraints
|
coding | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
snomedCT | Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. A code from the SNOMED UK Clinical Terminology coding system UKCoreReportCodeSnCT (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdDiagnosticReport.code.coding:snomedCT.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.code.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
subject | S Σ I | 1..1 | Reference(Data Standards Wales Patient) | Element IdDiagnosticReport.subject The subject of the report - which is always a patient for Laboratory Reports Alternate namesPatient DefinitionThe subject of the report - which is always a patient for Laboratory Reports. SHALL know the subject context. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(Data Standards Wales Patient) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.subject.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.subject.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.subject.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.subject.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
encounter | S Σ I | 0..1 | Reference(Data Standards Wales Encounter) | Element IdDiagnosticReport.encounter Health care event when test ordered Alternate namesContext DefinitionThe healthcare event (e.g. a patient and healthcare provider interaction) which this DiagnosticReport is about. Links the request to the Encounter context. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests). Reference(Data Standards Wales Encounter) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.encounter.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
effective[x] | S Σ | 0..1 | There are no (further) constraints on this element Element IdDiagnosticReport.effective[x] Clinically relevant time/time-period for report Alternate namesObservation time, Effective Time, Occurrence DefinitionThe time or time-period the observed values are related to. When the subject of the report is a patient, this is usually either the time of the procedure or of specimen collection(s), but very often the source of the date/time is not known, only the date/time itself. Need to know where in the patient history to file/present this report. If the diagnostic procedure was performed on the patient, this is the time it was performed. If there are specimens, the diagnostically relevant time can be derived from the specimen collection times, but the specimen information is not always available, and the exact relationship between the specimens and the diagnostically relevant time is not always automatic.
| |
effectiveDateTime | dateTime | There are no (further) constraints on this element Data Type | ||
effectivePeriod | Period | There are no (further) constraints on this element Data Type | ||
issued | S Σ | 0..1 | instant | There are no (further) constraints on this element Element IdDiagnosticReport.issued DateTime this version was made Alternate namesDate published, Date Issued, Date Verified DefinitionThe date and time that this version of the report was made available to providers, typically after the report was reviewed and verified. Clinicians need to be able to check the date that the report was released. May be different from the update time of the resource itself, because that is the status of the record (potentially a secondary copy), not the actual release time of the report.
|
performer | S Σ I | 0..* | Reference(UK Core CareTeam | Data Standards Wales Practitioner | Data Standards Wales Practitioner Role | Data Standards Wales Organization) | Element IdDiagnosticReport.performer Responsible Diagnostic Service Alternate namesLaboratory, Service, Practitioner, Department, Company, Authorized by, Director DefinitionThe diagnostic service that is responsible for issuing the report. Need to know whom to contact if there are queries about the results. Also may need to track the source of reports for secondary data analysis. This is not necessarily the source of the atomic data items or the entity that interpreted the results. It is the entity that takes responsibility for the clinical report. Reference(UK Core CareTeam | Data Standards Wales Practitioner | Data Standards Wales Practitioner Role | Data Standards Wales Organization) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.performer.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.performer.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.performer.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.performer.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
resultsInterpreter | Σ I | 0..* | Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Organization | UK Core CareTeam) | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter Primary result interpreter Alternate namesAnalyzed by, Reported by DefinitionThe practitioner or organization that is responsible for the report's conclusions and interpretations. Need to know whom to contact if there are queries about the results. Also may need to track the source of reports for secondary data analysis. Might not be the same entity that takes responsibility for the clinical report. Reference(UK Core Practitioner | UK Core PractitionerRole | UK Core Organization | UK Core CareTeam) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.resultsInterpreter.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
specimen | I | 0..* | Reference(Specimen) | There are no (further) constraints on this element Element IdDiagnosticReport.specimen Specimens this report is based on DefinitionDetails about the specimens on which this diagnostic report is based. Need to be able to report information about the collected specimens on which the report is based. If the specimen is sufficiently specified with a code in the test result name, then this additional data may be redundant. If there are multiple specimens, these may be represented per observation or group.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.specimen.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
result | S I | 0..* | Reference(Data Standards Wales Observation - Lab | Data Standards Wales Observation) | Element IdDiagnosticReport.result Observations Alternate namesData, Atomic Value, Result, Atomic result, Data, Test, Analyte, Battery, Organizer DefinitionObservations that are part of this diagnostic report. Need to support individual results, or groups of results, where the result grouping is arbitrary, but meaningful. Observations can contain observations. Reference(Data Standards Wales Observation - Lab | Data Standards Wales Observation) Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.result.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.result.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.result.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.result.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
imagingStudy | I | 0..* | Reference(ImagingStudy) | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy Reference to full details of imaging associated with the diagnostic report DefinitionOne or more links to full details of any imaging performed during the diagnostic investigation. Typically, this is imaging performed by DICOM enabled modalities, but this is not required. A fully enabled PACS viewer can use this information to provide views of the source images. ImagingStudy and the image element are somewhat overlapping - typically, the list of image references in the image element will also be found in one of the imaging study resources. However, each caters to different types of displays for different types of purposes. Neither, either, or both may be provided.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.imagingStudy.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
media | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdDiagnosticReport.media Key images associated with this report Alternate namesDICOM, Slides, Scans DefinitionA list of key images associated with this report. The images are generally created during the diagnostic process, and may be directly of the patient, or of treated specimens (i.e. slides of interest). Many diagnostic services include images in the report as part of their service.
|
comment | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.comment Comment about the image (e.g. explanation) DefinitionA comment about the image. Typically, this is used to provide an explanation for why the image is included, or to draw the viewer's attention to important features. The provider of the report should make a comment about each image included in the report. The comment should be displayed with the image. It would be common for the report to include additional discussion of the image contents in other sections such as the conclusion.
| |
link | Σ I | 1..1 | Reference(Media) | There are no (further) constraints on this element Element IdDiagnosticReport.media.link Reference to the image source DefinitionReference to the image source. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model). ResourceType (extensible)Constraints
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
use | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary. Identifies the purpose for this identifier, if known . IdentifierUse (required)Constraints
|
type | Σ | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. A coded type for an identifier that can be used to determine which identifier to use for a specific purpose. Identifier Type Codes (extensible)Constraints
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ I | 0..1 | Period | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use. A Period specifies a range of time; the context of use will specify whether the entire range applies (e.g. "the patient was an inpatient of the hospital for this time range") or one value from the range applies (e.g. "give to the patient between these two times"). Period is not used for a duration (a measure of elapsed time). See Duration.
|
assigner | Σ I | 0..1 | Reference(UK Core Organization) | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization. Reference(UK Core Organization) Constraints
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.media.link.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
conclusion | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusion Clinical conclusion (interpretation) of test results Alternate namesReport DefinitionConcise and clinically contextualized summary conclusion (interpretation/impression) of the diagnostic report. Need to be able to provide a conclusion that is not lost among the basic result data. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
conclusionCode | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode Codes for the clinical conclusion of test results DefinitionOne or more codes that represent the summary conclusion (interpretation/impression) of the diagnostic report. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Diagnosis codes provided as adjuncts to the report. SNOMEDCTClinicalFindings (example)Constraints
| |
coding | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. Unordered, Open, by system(Value) Constraints
|
snomedCT | Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true. A code from the SNOMED UK Clinical Terminology coding system UKCoreFindingCode (extensible)Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://snomed.info/sct
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.coding:snomedCT.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdDiagnosticReport.conclusionCode.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
presentedForm | I | 0..* | Attachment | There are no (further) constraints on this element Element IdDiagnosticReport.presentedForm Entire report as issued DefinitionRich text representation of the entire result as issued by the diagnostic service. Multiple formats are allowed but they SHALL be semantically equivalent. Gives laboratory the ability to provide its own fully formatted report for clinical fidelity. "application/pdf" is recommended as the most reliable and interoperable in this context.
|
Mandatory and Must Support Data Elements
Refer to the Mandatory and Must Support page for guidance on how these elements should be interpreted.
Each DiagnosticReport must have:
- A status
- A category of LAB *
- A code describing the type of report
- A patient
Each DiagnosticReport must support:
- A local or business identifier for the report
- An encounter
- An effective timestamp
- An issued date for this report version
- A performer
- Specimen(s)
- Test results(s)
*see Implementation Guidance for the identifier element below
Implementation Guidance
- The
DiagnosticReport.identifier
field SHOULD contain all available identifiers. Typical identifiers include:- Identifiers assigned to the DiagnosticReport by the Welsh Results and Reporting Service
- Other identifiers assigned by a hospital PAS or other clinical system.
- The
DiagnosticReport.status
field SHALL be populated to indicate whether the report is preliminary, partial, final. - The
DiagnosticReport.category
field SHALL be populated with a category code of LAB. Note that it is possible to include additional category codes. - The
DiagnosticReport.code
field SHALL be populated. - For laboratory reports, the
DiagnosticReport.subject
field SHALL contain reference to a patient resource. References to other resource types are not permissible. - The
DiagnosticReport.encounter
field SHOULD contain a reference to the encounter associated with the test report if this data is available. - The
DiagnosticReport.effective
field SHOULD be populated. The diagnostically relevant time (known as the “effective time” and typically the time of the procedure)* - When results become available, the
DiagnosticReport.result
field will include panels of results (such as a Full Blood Count or Liver Function Test panel) which are represented by observation resources that contain references to other nested Observations. Such observations and contained nested observations will implement the Data Standards Wales Observation Lab profile. - The
DiagnosticReport.issued
field SHOULD be populated. The time this version of the report was made available*
Example DiagnosticReports
The following example resources are provided within this guide:
Mandatory Search Parameters
The following search parameters and search parameter combinations SHALL be supported:
SHALL support searching by an DiagnosticReport identifier using the
identifier
search parameter:GET [base]/DiagnosticReport?identifier={system|}[code]
Example:
GET [base]/DiagnosticReport?identifier=https://fhir.nhs.wales/Id/wrrs-report-identifier|1000122
Implementation Notes: Fetches a bundle containing any DiagnosticReport resources matching the identifier (how to search by token).
SHALL support searching using the
patient
search parameter:GET [base]/DiagnosticReport?patient={Type/}[id]
Example:
GET [base]/DiagnosticReport?patient=Patient/NN046351-149
GET [base]/DiagnosticReport?patient:identifier=https://fhir.nhs.uk/Id/nhs-number|9912003444
Implementation Notes: Fetches a bundle of all DiagnosticReport resources for the specified patient (how to search by reference)
SHALL support searching using the combination of the
patient
andcode
search parameters:- including optional support for OR search on
code
(e.g.code={system|}[code],{system|}[code],...
)
GET [base]/DiagnosticReport?patient={Type/}[id]&code={system|}[code]{,{system|}[code],...}
Example:
GET \[base\]/DiagnosticReport?patient=23&code=https://fhir.nhs.wales/Id/wrrs-provider-system-code|FBC
GET \[base\]/DiagnosticReport?patient:identifier=https://fhir.nhs.uk/Id/nhs-number|9912003444&code=https://fhir.nhs.wales/Id/wrrs-provider-system-code|FBC,https://fhir.nhs.wales/Id/wrrs-provider-system-code|LFT
Implementation Notes: Fetches a bundle of all DiagnosticReport resources for the specified patient and DiagnosticReport code(s). SHOULD support search by multiple report codes. The DiagnosticReportcode
parameter searches `DiagnosticReport.code only. (how to search by reference and how to search by token)
- including optional support for OR search on
Optional Search Parameters
The following search parameters and search parameter combinations SHOULD be supported:
SHOULD support searching using the combination of the
patient
andstatus
search parameters:- including support for OR search on
status
(e.g.status={system|}[code],{system|}[code],...
)
GET [base]/DiagnosticReport?patient={Type/}[id]&status={system|}[code]{,{system|}[code],...}
Example:
GET \[base\]/DiagnosticReport?patient=23&status=final
Implementation Notes: Fetches a bundle of all DiagnosticReport resources for the specified patient and status (how to search by reference and how to search by token)
- including support for OR search on
SHOULD support searching using the combination of the
patient
andcategory
anddate
search parameters:- including support for these
date
comparators:gt,lt,ge,le
- including optional support for AND search on
date
(e.g.date=[date]&date=[date]]&...
)
GET [base]/DiagnosticReport?patient={Type/}[id]&category={system|}[code]&date={gt|lt|ge|le}[date]{&date={gt|lt|ge|le}[date]&...}
Example:
GET [base]/DiagnosticReport?Patient=Patient/23&category=http://terminology.hl7.org/CodeSystem/v2-0074|LAB&date=ge2010-01-14T00:00:00Z
Implementation Notes: Fetches a bundle of all DiagnosticReport resources for the specified patient and date and a category code specified in Data Standards Wales DiagnosticReport Category Codes (how to search by reference and how to search by token and how to search by date)
- including support for these
SHOULD support searching using the combination of the
patient
andcode
anddate
search parameters:- including optional support for OR search on
code
(e.g.code={system|}[code],{system|}[code],...
) - including support for these
date
comparators:gt,lt,ge,le
- including optional support for AND search on
date
(e.g.date=[date]&date=[date]]&...
)
GET [base]/DiagnosticReport?patient={Type/}[id]&code={system|}[code]{,{system|}[code],...}&date={gt|lt|ge|le}[date]{&date={gt|lt|ge|le}[date]&...}
Example:
GET [base\]/DiagnosticReport?Patient=Patient/23&code=https://fhir.nhs.wales/Id/wrrs-provider-system-code|FBC&date=ge2010-01-14T00:00:00Z
Implementation Notes: Fetches a bundle of all DiagnosticReport resources for the specified patient and date and report code(s). (how to search by reference and how to search by token and how to search by date)
- including optional support for OR search on