Visit the HL7 website
Visit the FHIR website

Pan-Canadian FHIR Exchange (CA:FeX) IGuide 2.2.0 DFT-Ballot

2.2.0-DFT-Ballot   Canada flag
  • Home
  • Business Context
    • Project Background
    • Scope
    • Relationship to Other Specifications
    • Use Cases
  • Technical Context
    • Overview
    • FHIR Exchange Paradigms
    • Sequence Diagrams
    • Actor Mapping to Interoperability Specification
    • Security
  • Actor and Conformance Options
    • Technical Actors
    • Actor Options
    • Conformance Requirements
  • FHIR Artifacts
    • Profiles and Extensions
    • Search Parameters
    • Operations
    • Capability Statements
  • Change Log
    • Change Log
    1. Home
    2. Technical Context
    3. Actor Mapping to Interoperability Specification
    4. Table 2 – Interoperability Recommendations for Use Case 2: Query and Retrieve Document

DFT Ballot - This specification is currently in ballot review and subject to change. It is not ready for limited roll-out or production level use. For a full list of available versions, see the Directory of published versions

Table 2 – Interoperability Recommendations for Use Case 2: Query and Retrieve Document

USE CASE ACTOR SERVICE SUPPORTED TECHNICAL ACTOR Implementation Expectation PROFILE/STANDARD
Consumer Authenticate User Client (e.g. EMR) Optional Internet User Authorization (IUA)
Consumer Retrieve Patient Identifier Client (e.g. EMR) Optional Use Existing Standard Employed by the Clinical System
Consumer Retrieve Patient Identifier Patient Demographic Consumer Optional PDQm
Central Infrastructure Return Patient Identifier Patient Identity Registry Optional PMIR
Consumer Request/Search Document (Patient Identifier) Client (e.g. EMR) Expected Use Existing Standard Employed by the Clinical System
Consumer Request/Search Document (Patient Identifier) Data Consumer Expected CA:FeX 2A: Search FHIR Document
Consumer Request Document (Resource ID) Client (e.g. EMR) Expected Use Existing Standard Employed by the Clinical System
Consumer Request Document (Resource ID) Data Consumer Expected CA:FeX 3A: Retrieve FHIR Document
Responder Return Searchset Bundle Data Responder Expected CA:FeX 2A: Search FHIR Document
Responder Return Document Bundle Data Responder Expected CA:FeX 3A: Retrieve FHIR Document

Note: These tables are not exhaustive and do not include all components required for a robust production deployment.
Aspects such as security, privacy, consent enforcement, and patient identity resolution are implementation-dependent and governed by jurisdictional or organizational policy.


Legend

  • Expected – Represents interactions that are typically expected in baseline implementations of CA:FeX.
  • Optional – Represents interactions that may apply based on local context, system configuration, or jurisdictional policy.

Table of Contents | IG © based on FHIR R4 | Package package:ca.infoway.io.cafex@2.2.0-DFT-Ballot | Version History
HL7® and FHIR® are the registered trademarks of Health Level Seven International