Sistema Generador : Device
Se utiliza el recurso Device para representar al sistema generador del resumen.
| Device_uv_ips (Device) | S | | http://hl7.org/fhir/StructureDefinition/Device | There are no (further) constraints on this element Element idDevice CommentsThis profile applies the rules defined by HL7 International for representing the UDI in the FHIR standard, by the document "Medical Devices and Unique Device Identification (UDI) Pattern, Release 1"
Data typehttp://hl7.org/fhir/StructureDefinition/Device |
| id | S | | | There are no (further) constraints on this element Element idDevice.id |
| meta | S | | | There are no (further) constraints on this element Element idDevice.meta |
| identifier | S | | | There are no (further) constraints on this element Element idDevice.identifier |
| type | S | 0..1 | Codeable Concept (IPS)Binding | There are no (further) constraints on this element Element idDevice.type Short descriptionType of device.
Preferably valued by using SNOMED CT.
The absence of information, or of devices relevant for purpose of this IPS, shall be explicitly stated by using the codes included in the absent-or-unknown-devices-uv-ips value set. Data typeCodeable Concept (IPS) SlicingUnordered, Open, by coding.system(Value) Discriminated by code system BindingThe type of device IPSMedicalDevices (preferred) |
| absentOrUnknownDevice | S | ..1 | Codeable Concept (IPS)Binding | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice DefinitionSlice to be valued in case of no information or known absence of relevant devices for the purpose of this IPS
Data typeCodeable Concept (IPS) BindingAbsent problem or unknown device IPSNoDevicesInfos (required) |
| coding | S | 1..1 | | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding |
| system | S | 1..1 | Fixed Value | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.system Fixed valuehttp://hl7.org/fhir/uv/ips/CodeSystem/absent-unknown-uv-ips |
| patient | S | 1.. | Reference(Patient (IPS)) | There are no (further) constraints on this element Element idDevice.patient Data typeReference(Patient (IPS)) |
| reference | S | 1.. | | There are no (further) constraints on this element Element idDevice.patient.reference |
Se describen solo los elementos obligatorios
| Device |
Descripción |
| identifier[1]/system[1] |
URL del Dominio para sus sistemas |
| identifier[1]/value[1] |
Identificacion del Sistema para el Dominio |
| deviceName[1]/name[1] |
Nombre del Sistema |
| deviceName[1]/type[1] |
Valor Fijo: "manufacturer-name" |
| type[1]/coding[1]/system[1] |
Valor Fijo: "http://snomed.info/sct" |
| type[1]/coding[1]/code[1] |
Valor Fijo: "462894001" |
| type[1]/coding[1]/display[1] |
Valor Fijo: "software de aplicación de sistema de información de historias clínicas de pacientes (objeto físico)" |
| owner[1]/identifier[1]/system[1] |
Valor Fijo: "http://fhir.msal.gov.ar/refes" (REFES) |
| owner[1]/identifier[1]/value[1] |
Identificador del emisor del resumen en REFES |