Sistema Generador : Device
Se utiliza el recurso Device para representar al sistema generador del resumen.
Device_uv_ips (Device) | S I | Device | Element idDevice Item used in healthcare DefinitionA type of a manufactured item that is used in the provision of healthcare without being substantially changed through that activity. The device may be a medical or non-medical device. This profile applies the rules defined by HL7 International for representing the UDI in the FHIR standard, by the document "Medical Devices and Unique Device Identification (UDI) Pattern, Release 1"
| |
id | S Σ | 0..1 | id | There are no (further) constraints on this element Element idDevice.id Logical id of this artifact DefinitionThe logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. The only time that a resource does not have an id is when it is being submitted to the server using a create operation.
|
meta | S Σ | 0..1 | Meta | There are no (further) constraints on this element Element idDevice.meta Metadata about the resource DefinitionThe metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.
|
implicitRules | Σ ?! | 0..1 | uri | There are no (further) constraints on this element Element idDevice.implicitRules A set of rules under which this content was created DefinitionA reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.
|
language | 0..1 | codeBinding | There are no (further) constraints on this element Element idDevice.language Language of the resource content DefinitionThe base language in which the resource is written. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). A human language.
| |
text | 0..1 | Narrative | There are no (further) constraints on this element Element idDevice.text Text summary of the resource, for human interpretation Alternate namesnarrative, html, xhtml, display DefinitionA human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.
| |
contained | 0..* | Resource | There are no (further) constraints on this element Element idDevice.contained Contained, inline Resources Alternate namesinline resources, anonymous resources, contained resources DefinitionThese resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
modifierExtension | ?! I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.modifierExtension Extensions that cannot be ignored Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
identifier | S | 0..* | Identifier | There are no (further) constraints on this element Element idDevice.identifier Instance identifier DefinitionUnique instance identifiers assigned to a device by manufacturers other organizations or owners. The barcode string from a barcode present on a device label or package may identify the instance, include names given to the device in local usage, or may identify the type of device. If the identifier identifies the type of device, Device.type element should be used.
|
definition | I | 0..1 | Reference(DeviceDefinition) | There are no (further) constraints on this element Element idDevice.definition The reference to the definition for the device DefinitionThe reference to the definition for the device. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
udiCarrier | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element idDevice.udiCarrier Unique Device Identifier (UDI) Barcode string DefinitionUnique device identifier (UDI) assigned to device label or package. Note that the Device may include multiple udiCarriers as it either may include just the udiCarrier for the jurisdiction it is sold, or for multiple jurisdictions it could have been sold. UDI may identify an unique instance of a device, or it may only identify the type of the device. See UDI mappings for a complete mapping of UDI parts to Device.
|
id | 0..1 | There are no (further) constraints on this element Element idDevice.udiCarrier.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| ||
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.udiCarrier.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
modifierExtension | Σ ?! I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.udiCarrier.modifierExtension Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
deviceIdentifier | Σ | 0..1 | string | There are no (further) constraints on this element Element idDevice.udiCarrier.deviceIdentifier Mandatory fixed portion of UDI Alternate namesDI DefinitionThe device identifier (DI) is a mandatory, fixed portion of a UDI that identifies the labeler and the specific version or model of a device. Note that FHIR strings SHALL NOT exceed 1MB in size
|
issuer | 0..1 | uri | There are no (further) constraints on this element Element idDevice.udiCarrier.issuer UDI Issuing Organization Alternate namesBarcode System DefinitionOrganization that is charged with issuing UDIs for devices. For example, the US FDA issuers include :
see http://en.wikipedia.org/wiki/Uniform_resource_identifier
| |
jurisdiction | 0..1 | uri | There are no (further) constraints on this element Element idDevice.udiCarrier.jurisdiction Regional UDI authority DefinitionThe identity of the authoritative source for UDI generation within a jurisdiction. All UDIs are globally unique within a single namespace with the appropriate repository uri as the system. For example, UDIs of devices managed in the U.S. by the FDA, the value is http://hl7.org/fhir/NamingSystem/fda-udi. Allows a recipient of a UDI to know which database will contain the UDI-associated metadata. see http://en.wikipedia.org/wiki/Uniform_resource_identifier
| |
carrierAIDC | Σ | 0..1 | base64Binary | There are no (further) constraints on this element Element idDevice.udiCarrier.carrierAIDC UDI Machine Readable Barcode String Alternate namesAutomatic Identification and Data Capture DefinitionThe full UDI carrier of the Automatic Identification and Data Capture (AIDC) technology representation of the barcode string as printed on the packaging of the device - e.g., a barcode or RFID. Because of limitations on character sets in XML and the need to round-trip JSON data through XML, AIDC Formats SHALL be base64 encoded. The AIDC form of UDIs should be scanned or otherwise used for the identification of the device whenever possible to minimize errors in records resulting from manual transcriptions. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label.
|
carrierHRF | Σ | 0..1 | string | There are no (further) constraints on this element Element idDevice.udiCarrier.carrierHRF UDI Human Readable Barcode String Alternate namesHuman Readable Form DefinitionThe full UDI carrier as the human readable form (HRF) representation of the barcode string as printed on the packaging of the device. If separate barcodes for DI and PI are present, concatenate the string with DI first and in order of human readable expression on label.
|
entryType | 0..1 | codeBinding | There are no (further) constraints on this element Element idDevice.udiCarrier.entryType barcode | rfid | manual + DefinitionA coded entry to indicate how the data was entered. Supports a way to distinguish hand entered from machine read data. Note that FHIR strings SHALL NOT exceed 1MB in size Codes to identify how UDI data was entered.
| |
status | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idDevice.status active | inactive | entered-in-error | unknown DefinitionStatus of the Device availability. This element is labeled as a modifier because the status contains the codes inactive and entered-in-error that mark the device (record)as not currently valid. The availability status of the device.
|
statusReason | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element idDevice.statusReason online | paused | standby | offline | not-ready | transduc-discon | hw-discon | off DefinitionReason for the dtatus of the Device availability. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. The availability status reason of the device.
| |
distinctIdentifier | 0..1 | string | There are no (further) constraints on this element Element idDevice.distinctIdentifier The distinct identification string Alternate namesDistinct Identification Code (DIC) DefinitionThe distinct identification string as required by regulation for a human cell, tissue, or cellular and tissue-based product. For example, this applies to devices in the United States regulated under Code of Federal Regulation 21CFR§1271.290(c).
| |
manufacturer | 0..1 | string | There are no (further) constraints on this element Element idDevice.manufacturer Name of device manufacturer DefinitionA name of the manufacturer. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
manufactureDate | 0..1 | dateTime | There are no (further) constraints on this element Element idDevice.manufactureDate Date when the device was made DefinitionThe date and time when the device was manufactured.
| |
expirationDate | 0..1 | dateTime | There are no (further) constraints on this element Element idDevice.expirationDate Date and time of expiry of this device (if applicable) DefinitionThe date and time beyond which this device is no longer valid or should not be used (if applicable).
| |
lotNumber | 0..1 | string | There are no (further) constraints on this element Element idDevice.lotNumber Lot number of manufacture DefinitionLot number assigned by the manufacturer. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
serialNumber | 0..1 | string | There are no (further) constraints on this element Element idDevice.serialNumber Serial number assigned by the manufacturer DefinitionThe serial number assigned by the organization when the device was manufactured. Alphanumeric Maximum 20.
| |
deviceName | 0..* | BackboneElement | There are no (further) constraints on this element Element idDevice.deviceName The name of the device as given by the manufacturer DefinitionThis represents the manufacturer's name of the device as provided by the device, from a UDI label, or by a person describing the Device. This typically would be used when a person provides the name(s) or when the device represents one of the names available from DeviceDefinition.
| |
id | 0..1 | There are no (further) constraints on this element Element idDevice.deviceName.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| ||
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.deviceName.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
modifierExtension | Σ ?! I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.deviceName.modifierExtension Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
name | 1..1 | string | There are no (further) constraints on this element Element idDevice.deviceName.name The name of the device Alternate namesΣ DefinitionThe name of the device. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
type | 1..1 | codeBinding | There are no (further) constraints on this element Element idDevice.deviceName.type udi-label-name | user-friendly-name | patient-reported-name | manufacturer-name | model-name | other DefinitionThe type of deviceName. UDILabelName | UserFriendlyName | PatientReportedName | ManufactureDeviceName | ModelName. Note that FHIR strings SHALL NOT exceed 1MB in size The type of name the device is referred by.
| |
modelNumber | 0..1 | string | There are no (further) constraints on this element Element idDevice.modelNumber The model number for the device DefinitionThe model number for the device. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
partNumber | 0..1 | string | There are no (further) constraints on this element Element idDevice.partNumber The part number of the device DefinitionThe part number of the device. Alphanumeric Maximum 20.
| |
type | S | 0..1 | Codeable Concept (IPS)Binding | Element idDevice.type Type of device. Preferably valued by using SNOMED CT. The absence of information, or of devices relevant for purpose of this IPS, shall be explicitly stated by using the codes included in the absent-or-unknown-devices-uv-ips value set. DefinitionA concept that may be defined by a formal reference to a terminology or ontology or may be provided by text. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Unordered, Open, by coding.system(Value) Discriminated by code system Binding The type of device
|
absentOrUnknownDevice | S | 0..1 | Codeable Concept (IPS)Binding | Element idDevice.type:absentOrUnknownDevice Concept - reference to a terminology or just text DefinitionSlice to be valued in case of no information or known absence of relevant devices for the purpose of this IPS Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. Absent problem or unknown device
|
id | 0..1 | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| ||
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
coding | S Σ | 1..1 | Coding with translations | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding A reference to a code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information.
|
id | 0..1 | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| ||
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | S Σ | 1..1 | uriFixed Value | Element idDevice.type:absentOrUnknownDevice.coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
http://hl7.org/fhir/uv/ips/CodeSystem/absent-unknown-uv-ips
|
version | S Σ | 0..1 | string | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | S Σ | 0..1 | code | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | S Σ | 0..1 | string | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
id | 0..1 | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.display.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| ||
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.display.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
translation | S I | 0..* | Extension(Complex) | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.display.extension:translation Language Translation (Localization) Alternate namesextensions, user content DefinitionLanguage translation from base language of resource to another language. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Extension(Complex) Extension URLhttp://hl7.org/fhir/StructureDefinition/translation Constraints
|
value | 0..1 | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.display.value Primitive value for string DefinitionPrimitive value for string 1048576 | ||
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element idDevice.type:absentOrUnknownDevice.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
specialization | 0..* | BackboneElement | There are no (further) constraints on this element Element idDevice.specialization The capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication DefinitionThe capabilities supported on a device, the standards to which the device conforms for a particular purpose, and used for the communication.
| |
id | 0..1 | There are no (further) constraints on this element Element idDevice.specialization.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| ||
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.specialization.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
modifierExtension | Σ ?! I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.specialization.modifierExtension Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
systemType | 1..1 | CodeableConcept | There are no (further) constraints on this element Element idDevice.specialization.systemType The standard that is used to operate and communicate Alternate namesΣ DefinitionThe standard that is used to operate and communicate. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
version | 0..1 | string | There are no (further) constraints on this element Element idDevice.specialization.version The version of the standard that is used to operate and communicate DefinitionThe version of the standard that is used to operate and communicate. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
version | 0..* | BackboneElement | There are no (further) constraints on this element Element idDevice.version The actual design of the device or software version running on the device DefinitionThe actual design of the device or software version running on the device.
| |
id | 0..1 | There are no (further) constraints on this element Element idDevice.version.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| ||
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.version.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
modifierExtension | Σ ?! I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.version.modifierExtension Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
type | 0..1 | CodeableConcept | There are no (further) constraints on this element Element idDevice.version.type The type of the device version Alternate namesΣ DefinitionThe type of the device version. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
component | 0..1 | Identifier | There are no (further) constraints on this element Element idDevice.version.component A single component of the device version DefinitionA single component of the device version.
| |
value | 1..1 | string | There are no (further) constraints on this element Element idDevice.version.value The version text DefinitionThe version text. Note that FHIR strings SHALL NOT exceed 1MB in size
| |
property | 0..* | BackboneElement | There are no (further) constraints on this element Element idDevice.property The actual configuration settings of a device as it actually operates, e.g., regulation status, time properties DefinitionThe actual configuration settings of a device as it actually operates, e.g., regulation status, time properties.
| |
id | 0..1 | There are no (further) constraints on this element Element idDevice.property.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| ||
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.property.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
modifierExtension | Σ ?! I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.property.modifierExtension Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
type | 1..1 | CodeableConcept | There are no (further) constraints on this element Element idDevice.property.type Code that specifies the property DeviceDefinitionPropetyCode (Extensible) DefinitionCode that specifies the property DeviceDefinitionPropetyCode (Extensible). Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
valueQuantity | I | 0..* | Quantity | There are no (further) constraints on this element Element idDevice.property.valueQuantity Property value as a quantity DefinitionProperty value as a quantity. The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.
|
valueCode | 0..* | CodeableConcept | There are no (further) constraints on this element Element idDevice.property.valueCode Property value as a code, e.g., NTP4 (synced to NTP) DefinitionProperty value as a code, e.g., NTP4 (synced to NTP). Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
| |
patient | S I | 1..1 | Reference(Patient (IPS)) | Element idDevice.patient Patient to whom Device is affixed DefinitionPatient information, If the device is affixed to a person. If the device is implanted in a patient, then need to associate the device to the patient. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
id | 0..1 | There are no (further) constraints on this element Element idDevice.patient.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| ||
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idDevice.patient.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
reference | S Σ I | 1..1 | string | There are no (further) constraints on this element Element idDevice.patient.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | There are no (further) constraints on this element Element idDevice.patient.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified. Aa resource (or, for logical models, the URI of the logical model).
|
identifier | Σ | 0..1 | Identifier | There are no (further) constraints on this element Element idDevice.patient.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element idDevice.patient.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
owner | I | 0..1 | Reference(Organization) | There are no (further) constraints on this element Element idDevice.owner Organization responsible for device DefinitionAn organization that is responsible for the provision and ongoing maintenance of the device. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
contact | I | 0..* | ContactPoint | There are no (further) constraints on this element Element idDevice.contact Details for human/organization for support DefinitionContact details for an organization or a particular human that is responsible for the device. used for troubleshooting etc.
|
location | I | 0..1 | Reference(Location) | There are no (further) constraints on this element Element idDevice.location Where the device is found DefinitionThe place where the device can be found. Device.location can be used to track device location. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
url | 0..1 | uri | There are no (further) constraints on this element Element idDevice.url Network address to contact device DefinitionA network address on which the device may be contacted directly. If the device is running a FHIR server, the network address should be the Base URL from which a conformance statement may be retrieved.
| |
note | 0..* | Annotation | There are no (further) constraints on this element Element idDevice.note Device notes and comments DefinitionDescriptive information, usage information or implantation information that is not captured in an existing element. For systems that do not have structured annotations, they can simply communicate a single annotation with no author or time. This element may need to be included in narrative because of the potential for modifying information. Annotations SHOULD NOT be used to communicate "modifying" information that could be computable. (This is a SHOULD because enforcing user behavior is nearly impossible).
| |
safety | Σ | 0..* | CodeableConcept | There are no (further) constraints on this element Element idDevice.safety Safety Characteristics of Device DefinitionProvides additional safety characteristics about a medical device. For example devices containing latex. Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.
|
parent | I | 0..1 | Reference(Device) | There are no (further) constraints on this element Element idDevice.parent The parent device DefinitionThe parent device. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository.
|
Se describen solo los elementos obligatorios
Device | Descripción |
---|---|
identifier[1]/system[1] | URL del Dominio para sus sistemas |
identifier[1]/value[1] | Identificacion del Sistema para el Dominio |
deviceName[1]/name[1] | Nombre del Sistema |
deviceName[1]/type[1] | Valor Fijo: "manufacturer-name" |
type[1]/coding[1]/system[1] | Valor Fijo: "http://snomed.info/sct" |
type[1]/coding[1]/code[1] | Valor Fijo: "462894001" |
type[1]/coding[1]/display[1] | Valor Fijo: "software de aplicación de sistema de información de historias clínicas de pacientes (objeto físico)" |
owner[1]/identifier[1]/system[1] | Valor Fijo: "http://fhir.msal.gov.ar/refes" (REFES) |
owner[1]/identifier[1]/value[1] | Identificador del emisor del resumen en REFES |