NHS Digital FHIR Implementation Guide (Retired - 2.1.50)

This guidance is under active development by NHS Digital and content may be added or updated on a regular basis.

SDS-Endpoint

{
    "resourceType": "Endpoint",
    "id": "f0f0e921-92ca-4a88-a550-2dbb36f703af",
    "extension":  [
        {
            "extension":  [
                {
                    "url": "nhsMHSSyncReplyMode",
                    "valueString": "MSHSignalsOnly"
                },
                {
                    "url": "nhsMHSRetryInterval",
                    "valueString": "PT1M"
                },
                {
                    "url": "nhsMHSRetries",
                    "valueInteger": 2
                },
                {
                    "url": "nhsMHSPersistDuration",
                    "valueString": "PT5M"
                },
                {
                    "url": "nhsMHSDuplicateElimination",
                    "valueString": "always"
                },
                {
                    "url": "nhsMHSAckRequested",
                    "valueString": "always"
                },
                {
                    "url": "nhsMHSActor",
                    "valueString": "ebs"
                }
            ],
            "url": "https://fhir.nhs.uk/StructureDefinition/Extension-SDS-ReliabilityConfiguration"
        }
    ],
    "identifier":  [
        {
            "system": "https://fhir.nhs.uk/Id/nhsEndpointServiceId",
            "value": "urn:nhs:names:services:psis:REPC_IN150016UK05"
        },
        {
            "system": "https://fhir.nhs.uk/Id/nhsMhsFQDN",
            "value": "192.168.128.11"
        },
        {
            "system": "https://fhir.nhs.uk/Id/nhsMhsPartyKey",
            "value": "R8008-0000806"
        },
        {
            "system": "https://fhir.nhs.uk/Id/nhsMhsCPAId",
            "value": "S20001A000182"
        },
        {
            "system": "https://fhir.nhs.uk/Id/nhsSpineASID",
            "value": "227319907548"
        }
    ],
    "status": "active",
    "connectionType": {
        "system": "http://terminology.hl7.org/CodeSystem/endpoint-connection-type",
        "code": "hl7-fhir-msg",
        "display": "HL7 FHIR Messaging"
    },
    "managingOrganization": {
        "identifier": {
            "system": "https://fhir.nhs.uk/Id/ods-organization-code",
            "value": "R8008"
        }
    },
    "payloadType":  [
        {
            "coding":  [
                {
                    "system": "http://terminology.hl7.org/CodeSystem/endpoint-payload-type",
                    "code": "any",
                    "display": "Any"
                }
            ]
        }
    ],
    "address": "https://192.168.128.11/reliablemessaging/reliablerequest"
}
<Endpoint xmlns="http://hl7.org/fhir">
    <id value="f0f0e921-92ca-4a88-a550-2dbb36f703af" />
    <extension url="https://fhir.nhs.uk/StructureDefinition/Extension-SDS-ReliabilityConfiguration">
        <extension url="nhsMHSSyncReplyMode">
            <valueString value="MSHSignalsOnly" />
        </extension>
        <extension url="nhsMHSRetryInterval">
            <valueString value="PT1M" />
        </extension>
        <extension url="nhsMHSRetries">
            <valueInteger value="2" />
        </extension>
        <extension url="nhsMHSPersistDuration">
            <valueString value="PT5M" />
        </extension>
        <extension url="nhsMHSDuplicateElimination">
            <valueString value="always" />
        </extension>
        <extension url="nhsMHSAckRequested">
            <valueString value="always" />
        </extension>
        <extension url="nhsMHSActor">
            <valueString value="ebs" />
        </extension>
    </extension>
    <identifier>
        <system value="https://fhir.nhs.uk/Id/nhsEndpointServiceId" />
        <value value="urn:nhs:names:services:psis:REPC_IN150016UK05" />
    </identifier>
    <identifier>
        <system value="https://fhir.nhs.uk/Id/nhsMhsFQDN" />
        <value value="192.168.128.11" />
    </identifier>
    <identifier>
        <system value="https://fhir.nhs.uk/Id/nhsMhsPartyKey" />
        <value value="R8008-0000806" />
    </identifier>
    <identifier>
        <system value="https://fhir.nhs.uk/Id/nhsMhsCPAId" />
        <value value="S20001A000182" />
    </identifier>
    <identifier>
        <system value="https://fhir.nhs.uk/Id/nhsSpineASID" />
        <value value="227319907548" />
    </identifier>
    <status value="active" />
    <connectionType>
        <system value="http://terminology.hl7.org/CodeSystem/endpoint-connection-type" />
        <code value="hl7-fhir-msg" />
        <display value="HL7 FHIR Messaging" />
    </connectionType>
    <managingOrganization>
        <identifier>
            <system value="https://fhir.nhs.uk/Id/ods-organization-code" />
            <value value="R8008" />
        </identifier>
    </managingOrganization>
    <payloadType>
        <coding>
            <system value="http://terminology.hl7.org/CodeSystem/endpoint-payload-type" />
            <code value="any" />
            <display value="Any" />
        </coding>
    </payloadType>
    <address value="https://192.168.128.11/reliablemessaging/reliablerequest" />
</Endpoint>
Endpoint
back to top