The core dataset module intensive care specifies acute medical data for primary and secondary use.
The modelling of the data should meet the requirements in terms of complexity and granularity of intensive care, emergency medicine, peripheral inpatient and outpatient data.
This document describes the KDS core dataset intensive care in accordance with development stage 2 (see figure below, "Stage 2").
At least one generic profile is provided for each data type to accommodate data that has not yet been specifically profiled. These generic profiles serve exclusively as templates for the rapid development of prototypes. Whenever possible, the specific profiles should be used.
The profiling also covers the underlying procedures (applications of extracorporeal procedures, ventilation and measurement procedures), the devices involved and their firmware and configuration versions.
Monitoring or vital data includes data such as: Blood pressure (arterial, central venous, pulmonary arterial, ventricular, arterial...), heart rate, temperature, haemodynamic monitoring (cardiac output per time period, cardiac output, systemic and pulmonary vascular resistance, etc.), pre- and post-ductal pulse oximetric oxygen saturation, etc.
The established monitoring and vital data profiles were transferred to ISiK Profile in version 2025.0.0 and have been maintained there in close cooperation ever since.
Parameters of extracorporeal procedures (extracorporeal membrane oxygenation, haemofiltration, dialysis, apharesis ...) include data such as: Blood flow, gas flow, dialysate flow, venous and arterial pressure etc.. Accesses are not yet part of the development stage 2 profiled here and are to be modelled in separate specific profiles in the future.
Using the example of ECMO parameters:
A gas flow is set on the ECMO device without a directly corresponding measured value being collected. The blood flow, on the other hand, can be both set and measured (set target value and actual measured blood flow). In both cases, the values are assigned to the same ECMO device on which the values are set or measured.
We distinguish between two types of measured and set values (see figure above):
Ventilation values include data such as ventilation mode, plateau pressure, end-expiratory pressure, support pressure, compliance, inspiratory oxygen fraction (FiO2), end-expiratory CO2 partial pressure, tidal volume, spontaneous and mechanical respiratory rate, etc.. Airways and accesses are not yet part of the development stage 2 profiled here and are to be modelled in separate specific profiles in the future.
Ventilation values are profiled analogue to parameters of extracorporeal procedures.
The semantic annotation references at least one primary code of the LOINC and/or SNOMED CT terminologies. Furthermore, a semantic annotation in accordance with ISO/IEEE 11073-10101 is added whenever possible to enable interoperability with medical device and medical product communication. Attention is also paid to semantic interoperability with the AKTIN data set.