HdBe-Visus
WARNING This page contains a draft CBB, as raw output from the zib export and automatic conversion to CBB. It requires thorough review and adaption to the Belgian realm. This CBB is merely added for informative use.
CBB | Concept | Status |
---|---|---|
HdBe-VisualAcuity | De visus is een maat voor het gezichtsvermogen (gezichtsscherpte). Het is een maat voor de kleinste details die iemand nog kan onderscheiden. PurposeHet doel is het bepalen van het visueel functioneren van de patient aan de hand van het gezichtsvermogen. Evidence Base**Pa#### Patient Population; Volwassenen en kinderen vanaf de leeftijd dat ze een plaatjeskaart kunnen interpreteren. Traceability to other StandardsDeze zorginformatie bouwsteen is gebaseerd op de bouwsteen blauwdruk Meting-v1.0. | draft |
VisualAcuity | VisualAcuity | ||
id | 0..1 | string | |
extension | I | 0..* | Extension |
VisualAcuityMeasurementDevice | 0..1 | CodeableConceptBinding | |
VisualAcuityType | 0..1 | CodeableConceptBinding | |
VisualAcuityMeasurementChart | 0..1 | CodeableConceptBinding | |
DistanceFromChart | I | 0..1 | Quantity |
DecimalVisualAqcuity | I | 0..1 | Quantity |
VisualAcuityDateTime | 0..1 | dateTime | |
AnatomicalLocation | 0..1 | HdBe-AnatomicalLocation |
VisualAcuity | 0..* | |
VisualAcuity.VisualAcuityMeasurementDevice | CodeableConcept | 0..1 |
VisualAcuity.VisualAcuityType | CodeableConcept | 0..1 |
VisualAcuity.VisualAcuityMeasurementChart | CodeableConcept | 0..1 |
VisualAcuity.DistanceFromChart | Quantity | 0..1 |
VisualAcuity.DecimalVisualAqcuity | Quantity | 0..1 |
VisualAcuity.VisualAcuityDateTime | dateTime | 0..1 |
VisualAcuity.AnatomicalLocation | HdBe-AnatomicalLocation | 0..1 |
VisualAcuity | |
Definition | Root concept of the VisualAcuity information model.This root concept contains all data elements of the VisualAcuity information model. |
Cardinality | 0...* |
Invariants |
|
Mappings |
|
VisualAcuity.id | |
Definition | Unique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. |
Cardinality | 0...1 |
Type | string |
Mappings |
|
VisualAcuity.extension | |
Definition | May be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. |
Cardinality | 0...* |
Type | Extension |
Alias | extensions, user content |
Comments | There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. |
Slicing | Unordered, Open, by url(Value) |
Invariants |
|
Mappings |
|
VisualAcuity.VisualAcuityMeasurementDevice | |
Definition | The device used measuring the visual acuity. |
Cardinality | 0...1 |
Type | CodeableConcept |
Binding | VisualAcuityMeasurementDevice codes |
Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. |
Invariants |
|
Mappings |
|
VisualAcuity.VisualAcuityType | |
Definition | Type of visual acuity measurment. |
Cardinality | 0...1 |
Type | CodeableConcept |
Binding | VisualAcuityType codes |
Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. |
Invariants |
|
Mappings |
|
VisualAcuity.VisualAcuityMeasurementChart | |
Definition | The type of chart used for the visual acuity measurement. |
Cardinality | 0...1 |
Type | CodeableConcept |
Binding | VisualAcuityMeasurementChart codes |
Comments | Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination. |
Invariants |
|
Mappings |
|
VisualAcuity.DistanceFromChart | |
Definition | Distance to the chart in meters |
Cardinality | 0...1 |
Type | Quantity |
Comments | The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator. |
Invariants |
|
Mappings |
|
VisualAcuity.DecimalVisualAqcuity | |
Definition | The measured decimal visual acuity. |
Cardinality | 0...1 |
Type | Quantity |
Comments | The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator. |
Invariants |
|
Mappings |
|
VisualAcuity.VisualAcuityDateTime | |
Definition | The date and time when the visual acuity was measured. |
Cardinality | 0...1 |
Type | dateTime |
Invariants |
|
Mappings |
|
VisualAcuity.AnatomicalLocation | |
Definition | The laterality of the eye of which the visual acuity has been measured. |
Cardinality | 0...1 |
Type | HdBe-AnatomicalLocation |
Invariants |
|
Mappings |
|
Example instances
[CBB name] | |
---|---|
[Concept name ] | [example value] |
// example of NameInformation
## Example instances
| NameInformation | |
|----------------------|-------------------|
| FirstNames | Johanna Petronella Maria
| Initials | J.P.M.
| GivenName | Jo
| NameUsage | Geslachtsnaam partner gevolgd door eigen geslachtsnaam
| LastName.Prefix | van
| LastName.LastName | Putten
| LastNamePartner.PartnerPrefix | van der
| LastNamePartner.PartnerLastName | Giessen
| Titles |
zib [zib name + version](https://zibs.nl/wiki/[zib name + version(release)]) difference
Concept | Category | Description |
---|---|---|
[element.path] |
[category of change] | [Description of change]([Reference to ticket/issue/zulip chat using MarkDown link]) |
Terminology Bindings
Path | Name | Strength | URL |
---|---|---|---|
VisualAcuityMeasurementDevice | VisualAcuityMeasurementDevice | extensible | https://fhir.healthdata.be/ValueSet/VisualAcuityMeasurementDevice |
VisualAcuityType | VisualAcuityType | extensible | https://fhir.healthdata.be/ValueSet/VisualAcuityType |
VisualAcuityMeasurementChart | VisualAcuityMeasurementChart | extensible | https://fhir.healthdata.be/ValueSet/VisualAcuityMeasurementChart |