Important: This is a draft IG for trial use. Click here to give feedback.

EN NL

HdBe-Visus

WARNING This page contains a draft CBB, as raw output from the zib export and automatic conversion to CBB. It requires thorough review and adaption to the Belgian realm. This CBB is merely added for informative use.

CBBConceptStatus
HdBe-VisualAcuity

De visus is een maat voor het gezichtsvermogen (gezichtsscherpte). Het is een maat voor de kleinste details die iemand nog kan onderscheiden.

Purpose

Het doel is het bepalen van het visueel functioneren van de patient aan de hand van het gezichtsvermogen.

Evidence Base

**Pa#### Patient Population; Volwassenen en kinderen vanaf de leeftijd dat ze een plaatjeskaart kunnen interpreteren.

Traceability to other Standards

Deze zorginformatie bouwsteen is gebaseerd op de bouwsteen blauwdruk Meting-v1.0.

draft

id0..1string
extensionI0..*Extension
VisualAcuityMeasurementDevice0..1CodeableConceptBinding
VisualAcuityType0..1CodeableConceptBinding
VisualAcuityMeasurementChart0..1CodeableConceptBinding
DistanceFromChartI0..1Quantity
DecimalVisualAqcuityI0..1Quantity
VisualAcuityDateTime0..1dateTime
AnatomicalLocation0..1HdBe-AnatomicalLocation

VisualAcuity0..*
VisualAcuity.VisualAcuityMeasurementDeviceCodeableConcept0..1
VisualAcuity.VisualAcuityTypeCodeableConcept0..1
VisualAcuity.VisualAcuityMeasurementChartCodeableConcept0..1
VisualAcuity.DistanceFromChartQuantity0..1
VisualAcuity.DecimalVisualAqcuityQuantity0..1
VisualAcuity.VisualAcuityDateTimedateTime0..1
VisualAcuity.AnatomicalLocationHdBe-AnatomicalLocation0..1


VisualAcuity
DefinitionRoot concept of the VisualAcuity information model.This root concept contains all data elements of the VisualAcuity information model.
Cardinality0...*
Invariants
  • ele-1: All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim: n/a
VisualAcuity.id
DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
Cardinality0...1
Typestring
Mappings
  • rim: n/a
VisualAcuity.extension
DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.
Cardinality0...*
TypeExtension
Aliasextensions, user content
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

SlicingUnordered, Open, by url(Value)
Invariants
  • ele-1: All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
  • ext-1: Must have either extensions or value[x], not both
    extension.exists() != value.exists()
Mappings
  • rim: n/a
  • rim: N/A
VisualAcuity.VisualAcuityMeasurementDevice
DefinitionThe device used measuring the visual acuity.
Cardinality0...1
TypeCodeableConcept
Binding

VisualAcuityMeasurementDevice codes

VisualAcuityMeasurementDevice (extensible)
Comments

Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

Invariants
  • ele-1: All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim: n/a
  • v2: CE/CNE/CWE
  • rim: CD
  • orim: fhir:CodeableConcept rdfs:subClassOf dt:CD
VisualAcuity.VisualAcuityType
DefinitionType of visual acuity measurment.
Cardinality0...1
TypeCodeableConcept
Binding

VisualAcuityType codes

VisualAcuityType (extensible)
Comments

Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

Invariants
  • ele-1: All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim: n/a
  • v2: CE/CNE/CWE
  • rim: CD
  • orim: fhir:CodeableConcept rdfs:subClassOf dt:CD
VisualAcuity.VisualAcuityMeasurementChart
DefinitionThe type of chart used for the visual acuity measurement.
Cardinality0...1
TypeCodeableConcept
Binding

VisualAcuityMeasurementChart codes

VisualAcuityMeasurementChart (extensible)
Comments

Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

Invariants
  • ele-1: All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim: n/a
  • v2: CE/CNE/CWE
  • rim: CD
  • orim: fhir:CodeableConcept rdfs:subClassOf dt:CD
VisualAcuity.DistanceFromChart
DefinitionDistance to the chart in meters
Cardinality0...1
TypeQuantity
Comments

The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.

Invariants
  • ele-1: All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
  • qty-3: If a code for the unit is present, the system SHALL also be present
    code.empty() or system.exists()
Mappings
  • rim: n/a
  • v2: SN (see also Range) or CQ
  • rim: PQ, IVL<PQ>, MO, CO, depending on the values
VisualAcuity.DecimalVisualAqcuity
DefinitionThe measured decimal visual acuity.
Cardinality0...1
TypeQuantity
Comments

The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.

Invariants
  • ele-1: All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
  • qty-3: If a code for the unit is present, the system SHALL also be present
    code.empty() or system.exists()
Mappings
  • rim: n/a
  • v2: SN (see also Range) or CQ
  • rim: PQ, IVL<PQ>, MO, CO, depending on the values
VisualAcuity.VisualAcuityDateTime
DefinitionThe date and time when the visual acuity was measured.
Cardinality0...1
TypedateTime
Invariants
  • ele-1: All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim: n/a
VisualAcuity.AnatomicalLocation
DefinitionThe laterality of the eye of which the visual acuity has been measured.
Cardinality0...1
TypeHdBe-AnatomicalLocation
Invariants
  • ele-1: All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim: n/a

Example instances

[CBB name]
[Concept name ] [example value]

// example of NameInformation

## Example instances

| NameInformation      |                   |
|----------------------|-------------------|
| FirstNames | Johanna Petronella Maria   
| Initials | J.P.M. 
| GivenName | Jo 
| NameUsage | Geslachtsnaam partner gevolgd door eigen geslachtsnaam
| LastName.Prefix | van
| LastName.LastName | Putten
| LastNamePartner.PartnerPrefix | van der
| LastNamePartner.PartnerLastName | Giessen
| Titles |

zib [zib name + version](https://zibs.nl/wiki/[zib name + version(release)]) difference

Concept Category Description
[element.path] [category of change] [Description of change]([Reference to ticket/issue/zulip chat using MarkDown link])



Terminology Bindings

PathNameStrengthURL
VisualAcuityMeasurementDeviceVisualAcuityMeasurementDeviceextensiblehttps://fhir.healthdata.be/ValueSet/VisualAcuityMeasurementDevice
VisualAcuityTypeVisualAcuityTypeextensiblehttps://fhir.healthdata.be/ValueSet/VisualAcuityType
VisualAcuityMeasurementChartVisualAcuityMeasurementChartextensiblehttps://fhir.healthdata.be/ValueSet/VisualAcuityMeasurementChart