<StructureDefinition xmlns="http://hl7.org/fhir">
  <id value="POWER2DM-Observation11" />
  <meta>
    <versionId value="3" />
    <lastUpdated value="2016-11-14T11:12:06.444+00:00" />
  </meta>
  <url value="http://www.power2dm.eu/pds/StructureDefinition/POWER2DM_Observation" />
  <version value="0.1" />
  <name value="POWER2DM_Observation" />
  <display value="POWER2DM_Observation" />
  <status value="draft" />
  <publisher value="SRDC Corp." />
  <date value="2016-11-30T00:00:00+03:00" />
  <description value="Common profile to represent all observations in POWER2DM Care Program" />
  <fhirVersion value="1.0.2" />
  <kind value="resource" />
  <constrainedType value="Observation" />
  <abstract value="true" />
  <base value="http://hl7.org/fhir/StructureDefinition/Observation" />
  <differential>
    <element>
      <path value="Observation" />
      <type>
        <code value="Observation" />
      </type>
    </element>
    <element>
      <path value="Observation.extension" />
      <slicing>
        <discriminator value="url" />
        <rules value="openAtEnd" />
      </slicing>
    </element>
    <element>
      <path value="Observation.extension" />
      <name value="acknowledgedPlannedAction" />
      <definition value="Optional Extensions Element - found in all resources." />
      <min value="0" />
      <max value="1" />
      <type>
        <code value="Extension" />
        <profile value="http://www.power2dm.eu/pds/StructureDefinition/POWER2DM_acknowledgedPlannedAction" />
      </type>
    </element>
    <element>
      <path value="Observation.identifier" />
      <max value="1" />
    </element>
    <element>
      <extension url="http://hl7.org/fhir/StructureDefinition/structuredefinition-display-hint">
        <valueString value="default: final" />
      </extension>
      <path value="Observation.status" />
      <fixedCode value="final" />
    </element>
    <element>
      <path value="Observation.code" />
      <binding>
        <strength value="extensible" />
        <description value="Codes identifying names of Observations used in POWER2DM Care program ..." />
        <valueSetReference>
          <reference value="http://www.power2dm.eu/pds/ValueSet/pdm-observations" />
        </valueSetReference>
      </binding>
    </element>
    <element>
      <path value="Observation.subject" />
      <min value="1" />
      <type>
        <code value="Reference" />
        <profile value="http://www.power2dm.eu/pds/StructureDefinition/POWER2DM_Patient" />
      </type>
    </element>
    <element>
      <path value="Observation.effective[x]" />
      <min value="1" />
    </element>
    <element>
      <path value="Observation.performer" />
      <max value="1" />
      <type>
        <code value="Reference" />
        <profile value="http://www.power2dm.eu/pds/StructureDefinition/POWER2DM_Patient" />
      </type>
      <type>
        <code value="Reference" />
        <profile value="http://www.power2dm.eu/pds/StructureDefinition/POWER2DM_Practitioner" />
      </type>
      <type>
        <code value="Reference" />
        <profile value="http://www.power2dm.eu/pds/StructureDefinition/POWER2DM_Organization" />
      </type>
    </element>
    <element>
      <path value="Observation.dataAbsentReason" />
      <max value="0" />
    </element>
    <element>
      <path value="Observation.device" />
      <type>
        <code value="Reference" />
        <profile value="http://www.power2dm.eu/pds/StructureDefinition/POWER2DM_Device" />
      </type>
    </element>
    <element>
      <path value="Observation.referenceRange" />
      <max value="1" />
    </element>
  </differential>