  "resourceType": "StructureDefinition",
  "id": "e188db12-fe59-4237-9207-98dda7c1c9d7",
  "meta": {
    "lastUpdated": "2022-03-08T09:47:42.861+00:00"
  },
  "url": "https://fhir.cambio.se/StructureDefinition/ObservationBPLite/v1",
  "version": "1.1.0",
  "name": "ObservationBPLite",
  "status": "active",
  "date": "2021-11-18T09:02:23.0267211+00:00",
  "description": "Cambio Lite profile for communicating the vital parameter, Blood Pressure, between an external system and COSMIC. The profile includes fields for the values for systolic and diastolic blood pressure, contextuel data and meta data.",
  "fhirVersion": "4.0.1",
  "mapping": [
    {
      "identity": "workflow",
      "uri": "http://hl7.org/fhir/workflow",
      "name": "Workflow Pattern"
    },
    {
      "identity": "sct-concept",
      "uri": "http://snomed.info/conceptdomain",
      "name": "SNOMED CT Concept Domain Binding"
    },
    {
      "identity": "v2",
      "uri": "http://hl7.org/v2",
      "name": "HL7 v2 Mapping"
    },
    {
      "identity": "rim",
      "uri": "http://hl7.org/v3",
      "name": "RIM Mapping"
    },
    {
      "identity": "w5",
      "uri": "http://hl7.org/fhir/fivews",
      "name": "FiveWs Pattern Mapping"
    },
    {
      "identity": "sct-attr",
      "uri": "http://snomed.org/attributebinding",
      "name": "SNOMED CT Attribute Binding"
    }
  ],
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "https://fhir.cambio.se/StructureDefinition/observationBPCore/v1",
  "derivation": "constraint",
  "snapshot": {},
  "differential": {
    "element": [
      {
        "id": "Observation.meta",
        "path": "Observation.meta",
        "min": 1
      },
      {
        "id": "Observation.meta.source",
        "path": "Observation.meta.source",
        "mustSupport": true
      },
      {
        "id": "Observation.meta.profile",
        "path": "Observation.meta.profile",
        "min": 1,
        "max": "1"
      },
      {
        "id": "Observation.basedOn",
        "path": "Observation.basedOn",
        "max": "0"
      },
      {
        "id": "Observation.partOf",
        "path": "Observation.partOf",
        "max": "0"
      },
      {
        "id": "Observation.status",
        "path": "Observation.status",
        "definition": "The status of th result value. \r\nFHIR - Cambio\r\npreliminary -> unsigned\nfinal -> signed and completednonSignable\namended -> not supported\nentered in error -> invalidated\ncancelled -> removed",
        "binding": {
          "strength": "required",
          "description": "Subset of codes providing the status of an observation.",
          "valueSet": "https://cambio.codes/fhir/vs/vital-sign-status/v1"
        }
      },
      {
        "id": "Observation.code.coding",
        "path": "Observation.code.coding",
        "min": 2,
        "max": "2"
      },
      {
        "id": "Observation.encounter.identifier.system",
        "path": "Observation.encounter.identifier.system",
        "min": 1
      },
      {
        "id": "Observation.encounter.identifier.value",
        "path": "Observation.encounter.identifier.value",
        "min": 1
      },
      {
        "id": "Observation.issued",
        "path": "Observation.issued",
        "max": "0"
      },
      {
        "id": "Observation.performer",
        "path": "Observation.performer",
        "max": "2",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "http://hl7.org/fhir/StructureDefinition/Practitioner",
              "http://hl7.org/fhir/StructureDefinition/PractitionerRole",
              "http://hl7.org/fhir/StructureDefinition/Organization",
              "http://hl7.org/fhir/StructureDefinition/Patient"
            ]
          }
        ]
      },
      {
        "id": "Observation.performer:Practitioner",
        "path": "Observation.performer",
        "sliceName": "Practitioner"
      },
      {
        "id": "Observation.performer:Practitioner.identifier.system",
        "path": "Observation.performer.identifier.system",
        "definition": "OID for HSA-id Inera"
      },
      {
        "id": "Observation.performer:organization",
        "path": "Observation.performer",
        "sliceName": "organization",
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "https://commonprofiles.care/StructureDefinition/OrganizationSEVendorLite/v1"
            ]
          }
        ]
      },
      {
        "id": "Observation.note",
        "path": "Observation.note",
        "max": "0"
      },
      {
        "id": "Observation.bodySite",
        "path": "Observation.bodySite",
        "max": "0"
      },
      {
        "id": "Observation.method",
        "path": "Observation.method",
        "max": "0"
      },
      {
        "id": "Observation.device",
        "path": "Observation.device",
        "max": "0"
      },
      {
        "id": "Observation.hasMember",
        "path": "Observation.hasMember",
        "max": "0"
      },
      {
        "id": "Observation.component",
        "path": "Observation.component",
        "max": "2"
      },
      {
        "id": "Observation.component:SystolicBP",
        "path": "Observation.component",
        "sliceName": "SystolicBP"
      },
      {
        "id": "Observation.component:SystolicBP.code.coding",
        "path": "Observation.component.code.coding",
        "max": "2"
      },
      {
        "id": "Observation.component:SystolicBP.value[x]:valueQuantity",
        "path": "Observation.component.value[x]",
        "sliceName": "valueQuantity"
      },
      {
        "id": "Observation.component:SystolicBP.value[x]:valueQuantity.value",
        "path": "Observation.component.value[x].value",
        "definition": "The value of the measured amount. The value of the systolic blood pressure must be within the range of 0.0.. < 350.0.",
        "minValueDecimal": 0,
        "maxValueDecimal": 349.9
      },
      {
        "id": "Observation.component:DiastolicBP",
        "path": "Observation.component",
        "sliceName": "DiastolicBP"
      },
      {
        "id": "Observation.component:DiastolicBP.code.coding",
        "path": "Observation.component.code.coding",
        "max": "2"
      },
      {
        "id": "Observation.component:DiastolicBP.value[x]:valueQuantity",
        "path": "Observation.component.value[x]",
        "sliceName": "valueQuantity"
      },
      {
        "id": "Observation.component:DiastolicBP.value[x]:valueQuantity.value",
        "path": "Observation.component.value[x].value",
        "definition": "The value of the measured amount. The value of the diastolic blood pressure must be within the range of 0.0.. < 200.0.",
        "minValueDecimal": 0,
        "maxValueDecimal": 199.9
      }
    ]
  }
}