  "resourceType": "StructureDefinition",
  "id": "jcpm-obs-bp",
  "extension": [
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-category",
      "valueString": "Clinical.Diagnostics"
    },
    {
      "url": "http://hl7.org/fhir/StructureDefinition/structuredefinition-security-category",
      "valueCode": "patient"
    }
  ],
  "url": "http://fhir.outburn.co.il/StructureDefinition/jcpm-obs-bp",
  "version": "0.3.0",
  "name": "JCPMObservationBloodPressure",
  "title": "JCPM Observation Blood pressure Profile",
  "status": "active",
  "contact": [
    {
      "name": "Outburn LTD",
      "telecom": [
        {
          "system": "url",
          "value": "http://outburn.co.il"
        }
      ]
    }
  ],
  "description": "Proposed constraints and extensions on JCPM Blood Pressure Resource",
  "fhirVersion": "4.0.1",
  "mapping": [
    {
      "identity": "workflow",
      "uri": "http://hl7.org/fhir/workflow",
      "name": "Workflow Pattern"
    },
    {
      "identity": "sct-concept",
      "uri": "http://snomed.info/conceptdomain",
      "name": "SNOMED CT Concept Domain Binding"
    },
    {
      "identity": "v2",
      "uri": "http://hl7.org/v2",
      "name": "HL7 v2 Mapping"
    },
    {
      "identity": "rim",
      "uri": "http://hl7.org/v3",
      "name": "RIM Mapping"
    },
    {
      "identity": "w5",
      "uri": "http://hl7.org/fhir/fivews",
      "name": "FiveWs Pattern Mapping"
    },
    {
      "identity": "sct-attr",
      "uri": "http://snomed.org/attributebinding",
      "name": "SNOMED CT Attribute Binding"
    }
  ],
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "http://fhir.health.gov.il/StructureDefinition/il-core-observation",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation.category",
        "path": "Observation.category",
        "min": 1,
        "max": "1"
      },
      {
        "id": "Observation.category.coding",
        "path": "Observation.category.coding",
        "min": 1
      },
      {
        "id": "Observation.category.coding.system",
        "path": "Observation.category.coding.system",
        "min": 1,
        "fixedUri": "http://terminology.hl7.org/CodeSystem/observation-category"
      },
      {
        "id": "Observation.category.coding.code",
        "path": "Observation.category.coding.code",
        "min": 1,
        "fixedCode": "vital-signs"
      },
      {
        "id": "Observation.category.coding.display",
        "path": "Observation.category.coding.display",
        "fixedString": "Vital Signs"
      },
      {
        "id": "Observation.code",
        "path": "Observation.code",
        "short": "Blood Pressure",
        "patternCodeableConcept": {
          "coding": [
            {
              "code": "85354-9",
              "system": "http://loinc.org"
            }
          ]
        },
        "mustSupport": true
      },
      {
        "id": "Observation.subject",
        "path": "Observation.subject",
        "min": 1,
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "http://fhir.outburn.co.il/StructureDefinition/jcpm-patient"
            ]
          }
        ]
      },
      {
        "id": "Observation.encounter",
        "path": "Observation.encounter",
        "min": 1,
        "type": [
          {
            "code": "Reference",
            "targetProfile": [
              "http://fhir.outburn.co.il/StructureDefinition/jcpm-enc-delivery",
              "http://fhir.outburn.co.il/StructureDefinition/jcpm-enc-pregnancy"
            ]
          }
        ]
      },
      {
        "id": "Observation.component",
        "path": "Observation.component",
        "slicing": {
          "discriminator": [
            {
              "type": "pattern",
              "path": "code"
            }
          ],
          "ordered": false,
          "rules": "open"
        },
        "min": 2,
        "mustSupport": true
      },
      {
        "id": "Observation.component:systolic",
        "path": "Observation.component",
        "sliceName": "systolic",
        "short": "Systolic Blood Pressure",
        "min": 1,
        "max": "1",
        "mustSupport": true
      },
      {
        "id": "Observation.component:systolic.code",
        "path": "Observation.component.code",
        "short": "Systolic Blood Pressure Code",
        "patternCodeableConcept": {
          "coding": [
            {
              "code": "8480-6",
              "system": "http://loinc.org"
            }
          ]
        },
        "mustSupport": true
      },
      {
        "id": "Observation.component:systolic.valueQuantity",
        "path": "Observation.component.valueQuantity",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true
      },
      {
        "id": "Observation.component:systolic.valueQuantity.value",
        "path": "Observation.component.valueQuantity.value",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.component:systolic.valueQuantity.unit",
        "path": "Observation.component.valueQuantity.unit",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.component:systolic.valueQuantity.system",
        "path": "Observation.component.valueQuantity.system",
        "min": 1,
        "fixedUri": "http://unitsofmeasure.org",
        "mustSupport": true
      },
      {
        "id": "Observation.component:systolic.valueQuantity.code",
        "path": "Observation.component.valueQuantity.code",
        "min": 1,
        "fixedCode": "mm[Hg]",
        "mustSupport": true
      },
      {
        "id": "Observation.component:diastolic",
        "path": "Observation.component",
        "sliceName": "diastolic",
        "short": "Diastolic Blood Pressure",
        "min": 1,
        "max": "1",
        "mustSupport": true
      },
      {
        "id": "Observation.component:diastolic.code",
        "path": "Observation.component.code",
        "short": "Diastolic Blood Pressure Code",
        "patternCodeableConcept": {
          "coding": [
            {
              "code": "8462-4",
              "system": "http://loinc.org"
            }
          ]
        },
        "mustSupport": true
      },
      {
        "id": "Observation.component:diastolic.valueQuantity",
        "path": "Observation.component.valueQuantity",
        "min": 0,
        "max": "1",
        "type": [
          {
            "code": "Quantity"
          }
        ],
        "mustSupport": true
      },
      {
        "id": "Observation.component:diastolic.valueQuantity.value",
        "path": "Observation.component.valueQuantity.value",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.component:diastolic.valueQuantity.unit",
        "path": "Observation.component.valueQuantity.unit",
        "min": 1,
        "mustSupport": true
      },
      {
        "id": "Observation.component:diastolic.valueQuantity.system",
        "path": "Observation.component.valueQuantity.system",
        "min": 1,
        "fixedUri": "http://unitsofmeasure.org",
        "mustSupport": true
      },
      {
        "id": "Observation.component:diastolic.valueQuantity.code",
        "path": "Observation.component.valueQuantity.code",
        "min": 1,
        "fixedCode": "mm[Hg]",
        "mustSupport": true
      }
    ]
  }
}