<StructureDefinition xmlns="http://hl7.org/fhir">
  <id value="zib-Infusion" />
  <url value="http://nictiz.nl/fhir/StructureDefinition/zib-Infusion" />
  <version value="1.0.5" />
  <name value="Zib Infusion" />
  <title value="HCIM Infusion" />
  <status value="active" />
  <publisher value="Nictiz" />
  <contact>
    <name value="Nictiz" />
    <telecom>
      <system value="url" />
      <value value="https://www.nictiz.nl" />
      <use value="work" />
    </telecom>
  </contact>
  <description value="An infusion is a device that slowly injects fluid into a blood vessel. The infusion has a number of components.&#xD;&#xA;&#xD;&#xA;The infusion contains: &#xD;&#xA;&#xD;&#xA;* the (peripheral) cannula or the (central) catheter put into the patient peripherally or centrally;&#xD;&#xA;* the administering system connected to the cannula/catheter allowing the administered fluid to run,&#xD;&#xA;* the infusion bag containing the fluid.&#xD;&#xA;&#xD;&#xA;Multiple administering systems may be connected to one cannula/catheter. Furthermore, a central venous catheter may have multiple lumens. &#xD;&#xA;&#xD;&#xA;Arterial and epidural catheters also exist in addition to venous catheters." />
  <purpose value="The purpose of an infusion is usually to administer fluid and/or medication. &#xD;&#xA;Information on present infusions is recorded to inform other health professionals. This information is of importance in determining the care required for the patient and in safely administering medication. In a transfer situation, the information offers the option to realize continuity of care by organizing specific expertise and materials in advance, for example." />
  <copyright value="CC0" />
  <fhirVersion value="3.0.2" />
  <mapping>
    <identity value="hcim-infusion-v3.2-2017EN" />
    <uri value="https://zibs.nl/wiki/Infusion-v3.2(2017EN)" />
    <name value="HCIM Infusion-v3.2(2017EN)" />
  </mapping>
  <kind value="resource" />
  <abstract value="false" />
  <type value="DeviceUseStatement" />
  <baseDefinition value="http://nictiz.nl/fhir/StructureDefinition/zib-MedicalDevice" />
  <derivation value="constraint" />
  <differential>
    <element id="DeviceUseStatement">
      <path value="DeviceUseStatement" />
      <short value="Infusion" />
      <alias value="Infuus" />
      <mapping>
        <identity value="hcim-infusion-v3.2-2017EN" />
        <map value="NL-CM:10.2.1" />
        <comment value="Infusion" />
      </mapping>
    </element>
    <element id="DeviceUseStatement.extension">
      <path value="DeviceUseStatement.extension" />
      <slicing>
        <discriminator>
          <type value="value" />
          <path value="url" />
        </discriminator>
        <rules value="open" />
      </slicing>
      <min value="1" />
    </element>
    <element id="DeviceUseStatement.extension:LumenOrLine">
      <path value="DeviceUseStatement.extension" />
      <sliceName value="LumenOrLine" />
      <definition value="Container of the LumenOrLine concept. This container contains all data elements of the LumenOrLine concept.&#xD;&#xA;Central lines can contain one or more lumens; peripheral infusions do not have lumens and only have one line." />
      <min value="1" />
      <max value="3" />
      <type>
        <code value="Extension" />
        <profile value="http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-LumenOrLine" />
      </type>
      <mapping>
        <identity value="hcim-infusion-v3.2-2017EN" />
        <map value="NL-CM:10.2.10" />
        <comment value="LumenOrLine" />
      </mapping>
    </element>
    <element id="DeviceUseStatement.extension:LumenOrLine.extension">
      <path value="DeviceUseStatement.extension.extension" />
      <slicing>
        <discriminator>
          <type value="value" />
          <path value="url" />
        </discriminator>
        <rules value="open" />
      </slicing>
      <min value="0" />
    </element>
    <element id="DeviceUseStatement.extension:LumenOrLine.extension:LineStatus">
      <path value="DeviceUseStatement.extension.extension" />
      <sliceName value="LineStatus" />
      <min value="0" />
      <mapping>
        <identity value="hcim-infusion-v3.2-2017EN" />
        <map value="NL-CM:10.2.9" />
        <comment value="LineStatus" />
      </mapping>
    </element>
    <element id="DeviceUseStatement.extension:LumenOrLine.extension:LineStatus.valueCodeableConcept:valueCodeableConcept">
      <path value="DeviceUseStatement.extension.extension.valueCodeableConcept" />
      <sliceName value="valueCodeableConcept" />
      <binding>
        <strength value="extensible" />
      </binding>
    </element>
    <element id="DeviceUseStatement.extension:LumenOrLine.extension:LumenLocation">
      <path value="DeviceUseStatement.extension.extension" />
      <sliceName value="LumenLocation" />
      <min value="0" />
      <mapping>
        <identity value="hcim-infusion-v3.2-2017EN" />
        <map value="NL-CM:10.2.11" />
        <comment value="LumenLocation" />
      </mapping>
    </element>
    <element id="DeviceUseStatement.extension:LumenOrLine.extension:LumenLocation.valueCodeableConcept:valueCodeableConcept">
      <path value="DeviceUseStatement.extension.extension.valueCodeableConcept" />
      <sliceName value="valueCodeableConcept" />
      <binding>
        <strength value="extensible" />
      </binding>
    </element>
    <element id="DeviceUseStatement.extension:LumenOrLine.extension:LockFluid">
      <path value="DeviceUseStatement.extension.extension" />
      <sliceName value="LockFluid" />
      <min value="0" />
      <mapping>
        <identity value="hcim-infusion-v3.2-2017EN" />
        <map value="NL-CM:10.2.13" />
        <comment value="LockFluid" />
      </mapping>
    </element>
    <element id="DeviceUseStatement.extension:LumenOrLine.extension:AdministeringSystem">
      <path value="DeviceUseStatement.extension.extension" />
      <sliceName value="AdministeringSystem" />
      <min value="0" />
      <mapping>
        <identity value="hcim-infusion-v3.2-2017EN" />
        <map value="NL-CM:10.2.7" />
        <comment value="AdministeringSystem" />
      </mapping>
    </element>
    <element id="DeviceUseStatement.extension:LumenOrLine.extension:AdministeringSystem.valueReference:valueReference">
      <path value="DeviceUseStatement.extension.extension.valueReference" />
      <sliceName value="valueReference" />
      <type>
        <code value="Reference" />
        <targetProfile value="http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-AdministeringSystem" />
      </type>
    </element>
    <element id="DeviceUseStatement.device">
      <path value="DeviceUseStatement.device" />
      <type>
        <code value="Reference" />
        <targetProfile value="http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-Product" />
      </type>
      <mapping>
        <identity value="hcim-infusion-v3.2-2017EN" />
        <map value="NL-CM:10.2.3" />
        <comment value="InfusionCatheter::MedicalDevice" />
      </mapping>
    </element>
    <element id="DeviceUseStatement.note.text">
      <path value="DeviceUseStatement.note.text" />
      <definition value="A comment on the infusion." />
      <mapping>
        <identity value="hcim-infusion-v3.2-2017EN" />
        <map value="NL-CM:10.2.8" />
        <comment value="Comment" />
      </mapping>
    </element>
  </differential>
</StructureDefinition>