  "resourceType": "StructureDefinition",
  "id": "zib-Infusion",
  "url": "http://nictiz.nl/fhir/StructureDefinition/zib-Infusion",
  "version": "1.0.5",
  "name": "Zib Infusion",
  "title": "HCIM Infusion",
  "status": "active",
  "publisher": "Nictiz",
  "contact": [
    {
      "name": "Nictiz",
      "telecom": [
        {
          "system": "url",
          "value": "https://www.nictiz.nl",
          "use": "work"
        }
      ]
    }
  ],
  "description": "An infusion is a device that slowly injects fluid into a blood vessel. The infusion has a number of components.\r\n\r\nThe infusion contains: \r\n\r\n* the (peripheral) cannula or the (central) catheter put into the patient peripherally or centrally;\r\n* the administering system connected to the cannula/catheter allowing the administered fluid to run,\r\n* the infusion bag containing the fluid.\r\n\r\nMultiple administering systems may be connected to one cannula/catheter. Furthermore, a central venous catheter may have multiple lumens. \r\n\r\nArterial and epidural catheters also exist in addition to venous catheters.",
  "purpose": "The purpose of an infusion is usually to administer fluid and/or medication. \r\nInformation on present infusions is recorded to inform other health professionals. This information is of importance in determining the care required for the patient and in safely administering medication. In a transfer situation, the information offers the option to realize continuity of care by organizing specific expertise and materials in advance, for example.",
  "copyright": "CC0",
  "fhirVersion": "3.0.2",
  "mapping": [
    {
      "identity": "hcim-infusion-v3.2-2017EN",
      "uri": "https://zibs.nl/wiki/Infusion-v3.2(2017EN)",
      "name": "HCIM Infusion-v3.2(2017EN)"
    }
  ],
  "kind": "resource",
  "abstract": false,
  "type": "DeviceUseStatement",
  "baseDefinition": "http://nictiz.nl/fhir/StructureDefinition/zib-MedicalDevice",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "DeviceUseStatement",
        "path": "DeviceUseStatement",
        "short": "Infusion",
        "alias": [
          "Infuus"
        ],
        "mapping": [
          {
            "identity": "hcim-infusion-v3.2-2017EN",
            "map": "NL-CM:10.2.1",
            "comment": "Infusion"
          }
        ]
      },
      {
        "id": "DeviceUseStatement.extension",
        "path": "DeviceUseStatement.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "rules": "open"
        },
        "min": 1
      },
      {
        "id": "DeviceUseStatement.extension:LumenOrLine",
        "path": "DeviceUseStatement.extension",
        "sliceName": "LumenOrLine",
        "definition": "Container of the LumenOrLine concept. This container contains all data elements of the LumenOrLine concept.\r\nCentral lines can contain one or more lumens; peripheral infusions do not have lumens and only have one line.",
        "min": 1,
        "max": "3",
        "type": [
          {
            "code": "Extension",
            "profile": "http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-LumenOrLine"
          }
        ],
        "mapping": [
          {
            "identity": "hcim-infusion-v3.2-2017EN",
            "map": "NL-CM:10.2.10",
            "comment": "LumenOrLine"
          }
        ]
      },
      {
        "id": "DeviceUseStatement.extension:LumenOrLine.extension",
        "path": "DeviceUseStatement.extension.extension",
        "slicing": {
          "discriminator": [
            {
              "type": "value",
              "path": "url"
            }
          ],
          "rules": "open"
        },
        "min": 0
      },
      {
        "id": "DeviceUseStatement.extension:LumenOrLine.extension:LineStatus",
        "path": "DeviceUseStatement.extension.extension",
        "sliceName": "LineStatus",
        "min": 0,
        "mapping": [
          {
            "identity": "hcim-infusion-v3.2-2017EN",
            "map": "NL-CM:10.2.9",
            "comment": "LineStatus"
          }
        ]
      },
      {
        "id": "DeviceUseStatement.extension:LumenOrLine.extension:LineStatus.valueCodeableConcept:valueCodeableConcept",
        "path": "DeviceUseStatement.extension.extension.valueCodeableConcept",
        "sliceName": "valueCodeableConcept",
        "binding": {
          "strength": "extensible"
        }
      },
      {
        "id": "DeviceUseStatement.extension:LumenOrLine.extension:LumenLocation",
        "path": "DeviceUseStatement.extension.extension",
        "sliceName": "LumenLocation",
        "min": 0,
        "mapping": [
          {
            "identity": "hcim-infusion-v3.2-2017EN",
            "map": "NL-CM:10.2.11",
            "comment": "LumenLocation"
          }
        ]
      },
      {
        "id": "DeviceUseStatement.extension:LumenOrLine.extension:LumenLocation.valueCodeableConcept:valueCodeableConcept",
        "path": "DeviceUseStatement.extension.extension.valueCodeableConcept",
        "sliceName": "valueCodeableConcept",
        "binding": {
          "strength": "extensible"
        }
      },
      {
        "id": "DeviceUseStatement.extension:LumenOrLine.extension:LockFluid",
        "path": "DeviceUseStatement.extension.extension",
        "sliceName": "LockFluid",
        "min": 0,
        "mapping": [
          {
            "identity": "hcim-infusion-v3.2-2017EN",
            "map": "NL-CM:10.2.13",
            "comment": "LockFluid"
          }
        ]
      },
      {
        "id": "DeviceUseStatement.extension:LumenOrLine.extension:AdministeringSystem",
        "path": "DeviceUseStatement.extension.extension",
        "sliceName": "AdministeringSystem",
        "min": 0,
        "mapping": [
          {
            "identity": "hcim-infusion-v3.2-2017EN",
            "map": "NL-CM:10.2.7",
            "comment": "AdministeringSystem"
          }
        ]
      },
      {
        "id": "DeviceUseStatement.extension:LumenOrLine.extension:AdministeringSystem.valueReference:valueReference",
        "path": "DeviceUseStatement.extension.extension.valueReference",
        "sliceName": "valueReference",
        "type": [
          {
            "code": "Reference",
            "targetProfile": "http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-AdministeringSystem"
          }
        ]
      },
      {
        "id": "DeviceUseStatement.device",
        "path": "DeviceUseStatement.device",
        "type": [
          {
            "code": "Reference",
            "targetProfile": "http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-Product"
          }
        ],
        "mapping": [
          {
            "identity": "hcim-infusion-v3.2-2017EN",
            "map": "NL-CM:10.2.3",
            "comment": "InfusionCatheter::MedicalDevice"
          }
        ]
      },
      {
        "id": "DeviceUseStatement.note.text",
        "path": "DeviceUseStatement.note.text",
        "definition": "A comment on the infusion.",
        "mapping": [
          {
            "identity": "hcim-infusion-v3.2-2017EN",
            "map": "NL-CM:10.2.8",
            "comment": "Comment"
          }
        ]
      }
    ]
  }
}