<StructureDefinition xmlns="http://hl7.org/fhir">
  <id value="zib-Infusion-Product" />
  <url value="http://nictiz.nl/fhir/StructureDefinition/zib-Infusion-Product" />
  <version value="1.0.1" />
  <name value="Zib Infusion Product" />
  <title value="HCIM Infusion Product" />
  <status value="active" />
  <publisher value="Nictiz" />
  <contact>
    <name value="Nictiz" />
    <telecom>
      <system value="url" />
      <value value="https://www.nictiz.nl" />
      <use value="work" />
    </telecom>
  </contact>
  <description value="This resource is part of Infusion as defined by the Dutch Health and Care Information models (Dutch: Zorginformatiebouwsteen or ZIB) version 3.2, release 2017." />
  <purpose value="The purpose of an infusion is usually to administer fluid and/or medication. &#xD;&#xA;Information on present infusions is recorded to inform other health professionals. This information is of importance in determining the care required for the patient and in safely administering medication. In a transfer situation, the information offers the option to realize continuity of care by organizing specific expertise and materials in advance, for example." />
  <copyright value="CC0" />
  <fhirVersion value="3.0.2" />
  <mapping>
    <identity value="hcim-infusion-v3.2-2017EN" />
    <uri value="https://zibs.nl/wiki/Infusion-v3.2(2017EN)" />
    <name value="HCIM Infusion-v3.2(2017EN)" />
  </mapping>
  <kind value="resource" />
  <abstract value="false" />
  <type value="Device" />
  <baseDefinition value="http://nictiz.nl/fhir/StructureDefinition/zib-MedicalDeviceProduct" />
  <derivation value="constraint" />
  <differential>
    <element id="Device">
      <path value="Device" />
      <definition value="A description of the type of feeding tube based on the location where it was inserted and the position of the tip of the tube." />
    </element>
    <element id="Device.type">
      <path value="Device.type" />
      <definition value="A description of the type of cannula/catheter." />
      <comment value="If no cannula/catherer is present, or no information is available the HCIM Infusion root concept SNOMED CT code and display shall be used: 19923001 - Catheter, device (physical object)." />
      <binding>
        <strength value="extensible" />
        <description value="The code of the type of infusion product." />
        <valueSetReference>
          <reference value="http://decor.nictiz.nl/fhir/ValueSet/2.16.840.1.113883.2.4.3.11.60.40.2.10.2.1--20171231000000" />
          <display value="ProductTypeCodelijst" />
        </valueSetReference>
      </binding>
      <mapping>
        <identity value="hcim-infusion-v3.2-2017EN" />
        <map value="NL-CM:10.1.3" />
        <comment value="ProductType" />
      </mapping>
    </element>
  </differential>
</StructureDefinition>