<StructureDefinition xmlns="http://hl7.org/fhir">
  <id value="NICE-FeedingTubeSystem" />
  <meta>
    <lastUpdated value="2023-10-04T15:03:35.4691977+00:00" />
  </meta>
  <url value="https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-FeedingTubeSystem-2022Q1" />
  <version value="1" />
  <name value="NICE-FeedingTubeSystem" />
  <title value="NICE-FeedingTubeSystem" />
  <status value="active" />
  <date value="2023-10-26T09:56:07.4563357+00:00" />
  <publisher value="NICE" />
  <contact>
    <name value="NICE" />
    <telecom>
      <system value="email" />
      <value value="vragen@stichting-nice.nl" />
    </telecom>
  </contact>
  <description value="This profile is for submitting whether the patient received enteral nutrition." />
  <purpose value="This profile is used to submit feeding tube related information to the Dutch National Intensive Care Evaluation (NICE). It was derived from the Nictiz Health and Care Information Model (HCIM; Dutch: Zorginformatiebouwsteen or ZIB) FeedingTubeSystem, 2017 release version 3.1" />
  <copyright value="CC0" />
  <fhirVersion value="3.0.2" />
  <mapping>
    <identity value="NICE-Datadictionary-Capacity" />
    <uri value="https://www.stichting-nice.nl/dd/#561" />
    <name value="NICE-Datadictionary-Capacity" />
    <comment value="The Patient acuity registration" />
  </mapping>
  <kind value="resource" />
  <abstract value="false" />
  <type value="DeviceUseStatement" />
  <baseDefinition value="http://nictiz.nl/fhir/StructureDefinition/zib-FeedingTubeSystem" />
  <derivation value="constraint" />
  <differential>
    <element id="DeviceUseStatement">
      <path value="DeviceUseStatement" />
      <mapping>
        <identity value="NICE-Datadictionary-Capacity" />
        <map value="https://www.stichting-nice.nl/dd/#612" />
        <comment value="Nutrition - enteral" />
      </mapping>
    </element>
    <element id="DeviceUseStatement.extension">
      <path value="DeviceUseStatement.extension" />
      <min value="1" />
    </element>
    <element id="DeviceUseStatement.extension:MedicalDevice">
      <path value="DeviceUseStatement.extension" />
      <sliceName value="MedicalDevice" />
      <max value="0" />
    </element>
    <element id="DeviceUseStatement.extension:Verified">
      <path value="DeviceUseStatement.extension" />
      <sliceName value="Verified" />
      <short value="Is the instance validated by a medical professional?" />
      <definition value="Extension that is used to indicate whether the entire instance has been validated.&#xD;&#xA;&#xD;&#xA;Every instance shall be validated by a hospital member / datamanager. However, this is not always feasible in case of automated submission of NICE data elements. This extensions shall be used to indicate the validation status of the instance." />
      <min value="1" />
      <max value="1" />
      <type>
        <code value="Extension" />
        <profile value="https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Verified-2022Q1" />
      </type>
    </element>
    <element id="DeviceUseStatement.extension:HealthcareProvider">
      <path value="DeviceUseStatement.extension" />
      <sliceName value="HealthcareProvider" />
      <max value="0" />
    </element>
    <element id="DeviceUseStatement.extension:HealthProfessional">
      <path value="DeviceUseStatement.extension" />
      <sliceName value="HealthProfessional" />
      <max value="0" />
    </element>
    <element id="DeviceUseStatement.extension:reasonReference">
      <path value="DeviceUseStatement.extension" />
      <sliceName value="reasonReference" />
      <max value="0" />
    </element>
    <element id="DeviceUseStatement.extension:FeedingTubeLength">
      <path value="DeviceUseStatement.extension" />
      <sliceName value="FeedingTubeLength" />
      <max value="0" />
    </element>
    <element id="DeviceUseStatement.extension:EnteralNutrition">
      <path value="DeviceUseStatement.extension" />
      <sliceName value="EnteralNutrition" />
      <max value="0" />
    </element>
    <element id="DeviceUseStatement.status">
      <path value="DeviceUseStatement.status" />
      <short value="validated (completed)" />
      <fixedCode value="completed" />
    </element>
    <element id="DeviceUseStatement.subject">
      <path value="DeviceUseStatement.subject" />
      <type>
        <code value="Reference" />
        <targetProfile value="https://fhir.stichting-nice.nl/STU3/StructureDefinition/NICE-Patient-2022Q1" />
      </type>
    </element>
    <element id="DeviceUseStatement.whenUsed">
      <path value="DeviceUseStatement.whenUsed" />
      <mustSupport value="true" />
    </element>
    <element id="DeviceUseStatement.whenUsed.start">
      <path value="DeviceUseStatement.whenUsed.start" />
      <mustSupport value="true" />
    </element>
    <element id="DeviceUseStatement.whenUsed.end">
      <path value="DeviceUseStatement.whenUsed.end" />
      <mustSupport value="true" />
    </element>
  </differential>
</StructureDefinition>