<StructureDefinition xmlns="http://hl7.org/fhir">
  <url value="https://metisneurotec.com/fhir/StructureDefinition/MonitoringRequest" />
  <name value="MonitoringRequested" />
  <status value="draft" />
  <date value="2022-07-12T07:31:31.0906531+00:00" />
  <description value="Reference to a device or a questionnaire. Allows for ordering a specific questionnaire to be completed or a specific device to be used to monitor the patient. If a device is selected it can be defined which parameters, i.e., which device metrics should be monitored." />
  <fhirVersion value="4.0.1" />
  <kind value="complex-type" />
  <abstract value="false" />
  <context>
    <type value="element" />
    <expression value="ServiceRequest" />
  </context>
  <type value="Extension" />
  <baseDefinition value="http://hl7.org/fhir/StructureDefinition/Extension" />
  <derivation value="constraint" />
  <differential>
    <element id="Extension.extension">
      <path value="Extension.extension" />
      <slicing>
        <discriminator>
          <type value="value" />
          <path value="url" />
        </discriminator>
        <rules value="open" />
      </slicing>
      <min value="1" />
    </element>
    <element id="Extension.extension:dataSource">
      <path value="Extension.extension" />
      <sliceName value="dataSource" />
      <short value="Reference to either a device or a questionnaire" />
      <definition value="Order a specific questionnaire to be completed or a specific device to be used for collection of health data." />
      <min value="1" />
      <max value="1" />
    </element>
    <element id="Extension.extension:dataSource.url">
      <path value="Extension.extension.url" />
      <fixedUri value="dataSource" />
    </element>
    <element id="Extension.extension:dataSource.value[x]">
      <path value="Extension.extension.value[x]" />
      <min value="1" />
      <type>
        <code value="Reference" />
        <targetProfile value="http://hl7.org/fhir/StructureDefinition/Device" />
        <targetProfile value="http://hl7.org/fhir/StructureDefinition/Questionnaire" />
      </type>
    </element>
    <element id="Extension.extension:parameter">
      <path value="Extension.extension" />
      <sliceName value="parameter" />
      <short value="Device metrics that should be collected" />
      <definition value="Defines which device metrics should be collected if a device is used for monitoring." />
      <min value="0" />
    </element>
    <element id="Extension.extension:parameter.url">
      <path value="Extension.extension.url" />
      <fixedUri value="parameter" />
    </element>
    <element id="Extension.extension:parameter.value[x]">
      <path value="Extension.extension.value[x]" />
      <min value="1" />
      <type>
        <code value="Reference" />
        <targetProfile value="http://hl7.org/fhir/StructureDefinition/DeviceMetric" />
      </type>
    </element>
    <element id="Extension.url">
      <path value="Extension.url" />
      <fixedUri value="https://metisneurotec.com/fhir/StructureDefinition/MonitoringRequest" />
    </element>
    <element id="Extension.value[x]">
      <path value="Extension.value[x]" />
      <max value="0" />
    </element>
  </differential>
</StructureDefinition>