<StructureDefinition xmlns="http://hl7.org/fhir">
  <id value="mii-pr-icu-dm-eingest-gem-parameter-extrakorporale-verfahren" />
  <url value="https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-dm-eingest-gem-parameter-extrakorporale-verfahren" />
  <version value="2026.0.2" />
  <name value="MII_PR_ICU_Devicemetric_Eingestellte_Gemessene_Parameter_Extrakorporale_Verfahren" />
  <title value="MII PR ICU DeviceMetric Eingestellte Gemessene Parameter Extrakorporale Verfahren" />
  <status value="active" />
  <publisher value="Medizininformatik Initiative" />
  <contact>
    <telecom>
      <system value="url" />
      <value value="https://www.medizininformatik-initiative.de" />
    </telecom>
  </contact>
  <fhirVersion value="4.0.1" />
  <kind value="resource" />
  <abstract value="false" />
  <type value="DeviceMetric" />
  <baseDefinition value="http://hl7.org/fhir/StructureDefinition/DeviceMetric" />
  <derivation value="constraint" />
  <differential>
    <element id="DeviceMetric.type">
      <path value="DeviceMetric.type" />
      <mustSupport value="true" />
      <binding>
        <strength value="required" />
        <valueSet value="https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/ValueSet/mii-vs-icu-devicemetric-extrakorporale-verfahren" />
      </binding>
    </element>
    <element id="DeviceMetric.type.coding">
      <path value="DeviceMetric.type.coding" />
      <patternCoding>
        <system value="http://snomed.info/sct" />
        <code value="182744004" />
      </patternCoding>
      <mustSupport value="true" />
    </element>
    <element id="DeviceMetric.type.coding.system">
      <path value="DeviceMetric.type.coding.system" />
      <min value="1" />
      <mustSupport value="true" />
    </element>
    <element id="DeviceMetric.type.coding.code">
      <path value="DeviceMetric.type.coding.code" />
      <min value="1" />
      <mustSupport value="true" />
    </element>
    <element id="DeviceMetric.source">
      <path value="DeviceMetric.source" />
      <type>
        <code value="Reference" />
        <targetProfile value="https://www.medizininformatik-initiative.de/fhir/ext/modul-icu/StructureDefinition/mii-pr-icu-device" />
      </type>
      <mustSupport value="true" />
    </element>
    <element id="DeviceMetric.category">
      <path value="DeviceMetric.category" />
      <mustSupport value="true" />
    </element>
  </differential>