<DiagnosticReport xmlns="http://hl7.org/fhir">
  <id value="rdc-DiagnosticReport-agp-report" />
  <meta>
    <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-DiagnosticReport" />
  </meta>
  <contained>
    <Observation>
      <id value="Obs-1" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-CGM" />
      </meta>
      <extension url="https://roche.com/fhir/iop/StructureDefinition/ext-CalibrationStatus">
        <valueString value="calibrated" />
      </extension>
      <status value="final" />
      <code>
        <coding>
          <system value="http://snomed.info/sct" />
          <code value="434910001" />
          <display value="Interstitial fluid glucose concentration (observable entity)" />
        </coding>
      </code>
      <subject>
        <reference value="Patient/34605fdc-74aa-4587-a5f0-92e6c5f64527" />
      </subject>
      <effectivePeriod>
        <start value="2020-10-14T02:01:00+01:00" />
        <end value="2020-10-14T02:06:00+01:00" />
      </effectivePeriod>
      <valueSampledData>
        <extension url="https://roche.com/fhir/iop/StructureDefinition/ext-CGMFlags">
          <valueString value="HI; X; X; LO" />
        </extension>
        <origin>
          <value value="0" />
          <unit value="mg/dL" />
          <system value="http://unitsofmeasure.org" />
          <code value="mg/dL" />
        </origin>
        <interval value="60000" />
        <intervalUnit value="ms" />
        <dimensions value="1" />
        <data value="100 99 89 89" />
      </valueSampledData>
      <device>
        <reference value="Device/6ae8bff3-910a-419d-96f6-de0e8fd1d64d" />
      </device>
    </Observation>
  </contained>
  <contained>
    <Observation>
      <id value="Obs-2" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-CGM" />
      </meta>
      <extension url="https://roche.com/fhir/iop/StructureDefinition/ext-CalibrationStatus">
        <valueString value="calibrated" />
      </extension>
      <status value="final" />
      <code>
        <coding>
          <system value="http://snomed.info/sct" />
          <code value="434910001" />
          <display value="Interstitial fluid glucose concentration (observable entity)" />
        </coding>
      </code>
      <subject>
        <reference value="Patient/34605fdc-74aa-4587-a5f0-92e6c5f64527" />
      </subject>
      <effectivePeriod>
        <start value="2020-10-15T02:01:00+01:00" />
        <end value="2020-10-15T02:06:00+01:00" />
      </effectivePeriod>
      <valueSampledData>
        <extension url="https://roche.com/fhir/iop/StructureDefinition/ext-CGMFlags">
          <valueString value="HI; X; X; LO" />
        </extension>
        <origin>
          <value value="0" />
          <unit value="mg/dL" />
          <system value="http://unitsofmeasure.org" />
          <code value="mg/dL" />
        </origin>
        <interval value="60000" />
        <intervalUnit value="ms" />
        <dimensions value="1" />
        <data value="100 99 89 89" />
      </valueSampledData>
      <device>
        <reference value="Device/6ae8bff3-910a-419d-96f6-de0e8fd1d64d" />
      </device>
    </Observation>
  </contained>
  <contained>
    <Observation>
      <id value="Obs-3" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-Report" />
      </meta>
      <status value="final" />
      <code>
        <coding>
          <system value="http://loinc.org" />
          <code value="97507-8" />
          <display value="Average glucose [Mass/ volume] in Interstitial fluid during Reporting Period" />
        </coding>
      </code>
      <effectivePeriod>
        <start value="2020-10-15T02:01:00+01:00" />
        <end value="2020-10-15T02:06:00+01:00" />
      </effectivePeriod>
      <valueQuantity>
        <value value="136" />
        <unit value="mg/dL" />
        <system value="http://unitsofmeasure.org" />
        <code value="mg/dL" />
      </valueQuantity>
    </Observation>
  </contained>
  <contained>
    <Observation>
      <id value="Obs-4" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-Report" />
      </meta>
      <status value="final" />
      <code>
        <coding>
          <system value="https://roche.com/fhir/CodeSystem/general" />
          <code value="R9599-2" />
          <display value="CGM Glycemic Variability (%GV), during reporting period" />
        </coding>
      </code>
      <effectivePeriod>
        <start value="2020-10-15T02:01:00+01:00" />
        <end value="2020-10-15T02:06:00+01:00" />
      </effectivePeriod>
      <valueQuantity>
        <value value="35.5" />
        <unit value="mg/dL" />
        <system value="http://unitsofmeasure.org" />
        <code value="mg/dL" />
      </valueQuantity>
    </Observation>
  </contained>
  <contained>
    <Observation>
      <id value="Obs-5" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-Report" />
      </meta>
      <status value="final" />
      <code>
        <coding>
          <system value="http://loinc.org" />
          <code value="97504-5" />
          <display value="Percent sensor usage" />
        </coding>
      </code>
      <effectivePeriod>
        <start value="2020-10-15T02:01:00+01:00" />
        <end value="2020-10-15T02:06:00+01:00" />
      </effectivePeriod>
      <valueQuantity>
        <value value="100" />
        <unit value="%" />
        <system value="http://unitsofmeasure.org" />
        <code value="%" />
      </valueQuantity>
    </Observation>
  </contained>
  <contained>
    <Observation>
      <id value="Obs-6" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-Report" />
      </meta>
      <status value="final" />
      <code>
        <coding>
          <system value="http://loinc.org" />
          <code value="97506-0" />
          <display value="Glucose management indicator" />
        </coding>
      </code>
      <effectivePeriod>
        <start value="2020-10-15T02:01:00+01:00" />
        <end value="2020-10-15T02:06:00+01:00" />
      </effectivePeriod>
      <valueQuantity>
        <value value="6.6" />
        <unit value="%" />
        <system value="http://unitsofmeasure.org" />
        <code value="%" />
      </valueQuantity>
    </Observation>
  </contained>
  <contained>
    <Observation>
      <id value="Obs-7" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-Report" />
      </meta>
      <status value="final" />
      <code>
        <coding>
          <system value="http://loinc.org" />
          <code value="104639-0" />
          <display value="Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent above target glucose range, very high (TAR-VH &gt;250 mg/dL (&gt;13.9 mmol/L) (hyperglycemic) during reporting period" />
        </coding>
      </code>
      <effectivePeriod>
        <start value="2020-10-15T02:01:00+01:00" />
        <end value="2020-10-15T02:06:00+01:00" />
      </effectivePeriod>
      <valueQuantity>
        <value value="3" />
        <unit value="%" />
        <system value="http://unitsofmeasure.org" />
        <code value="%" />
      </valueQuantity>
    </Observation>
  </contained>
  <contained>
    <Observation>
      <id value="Obs-8" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-Report" />
      </meta>
      <status value="final" />
      <code>
        <coding>
          <system value="http://loinc.org" />
          <code value="104640-8" />
          <display value="Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent above target glucose range, high (TAR-H) 181-250 mg/ dL (10.1-13.9 mmol/L) (hyperglycemic) during reporting period" />
        </coding>
      </code>
      <effectivePeriod>
        <start value="2020-10-15T02:01:00+01:00" />
        <end value="2020-10-15T02:06:00+01:00" />
      </effectivePeriod>
      <valueQuantity>
        <value value="14" />
        <unit value="%" />
        <system value="http://unitsofmeasure.org" />
        <code value="%" />
      </valueQuantity>
    </Observation>
  </contained>
  <contained>
    <Observation>
      <id value="Obs-9" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-Report" />
      </meta>
      <status value="final" />
      <code>
        <coding>
          <system value="http://loinc.org" />
          <code value="97510-2" />
          <display value="Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent in target glucose range (70-180 mg/dL [3.9-10.0 mmol/L]) during reporting period. The primary goal for effective and safe glucose control is to increase the TIR whil" />
        </coding>
      </code>
      <effectivePeriod>
        <start value="2020-10-15T02:01:00+01:00" />
        <end value="2020-10-15T02:06:00+01:00" />
      </effectivePeriod>
      <valueQuantity>
        <value value="78" />
        <unit value="%" />
        <system value="http://unitsofmeasure.org" />
        <code value="%" />
      </valueQuantity>
    </Observation>
  </contained>
  <contained>
    <Observation>
      <id value="Obs-10" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-Report" />
      </meta>
      <status value="final" />
      <code>
        <coding>
          <system value="http://loinc.org" />
          <code value="104641-6" />
          <display value="Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent below target glucose range, low (TBR-L) 54-69 mg/dL (3.0-3.8 mmol/L) (hypoglycemic) during reporting period" />
        </coding>
      </code>
      <effectivePeriod>
        <start value="2020-10-15T02:01:00+01:00" />
        <end value="2020-10-15T02:06:00+01:00" />
      </effectivePeriod>
      <valueQuantity>
        <value value="5" />
        <unit value="%" />
        <system value="http://unitsofmeasure.org" />
        <code value="%" />
      </valueQuantity>
    </Observation>
  </contained>
  <contained>
    <Observation>
      <id value="Obs-11" />
      <meta>
        <profile value="https://roche.com/fhir/iop/StructureDefinition/rdc-Observation-Report" />
      </meta>
      <status value="final" />
      <code>
        <coding>
          <system value="http://loinc.org" />
          <code value="104642-4" />
          <display value="Amount of time, in percent, as measured by CGM (continuous glucose monitor) device, spent below target glucose range, very low (TBR-VL) &lt;54 mg/dL (&lt;3.0 mmol/L) (hypoglycemic) during reporting period" />
        </coding>
      </code>
      <effectivePeriod>
        <start value="2020-10-15T02:01:00+01:00" />
        <end value="2020-10-15T02:06:00+01:00" />
      </effectivePeriod>
      <valueQuantity>
        <value value="0" />
        <unit value="%" />
        <system value="http://unitsofmeasure.org" />
        <code value="%" />
      </valueQuantity>
    </Observation>
  </contained>
  <status value="final" />
  <code>
    <coding>
      <system value="https://roche.com/fhir/CodeSystem/general" />
      <code value="R7786-7" />
      <display value="CGM Ambulatory Glucose Profile (AGP) During Reporting Period" />
    </coding>
  </code>
  <subject>
    <reference value="Patient-Reference" />
  </subject>
  <effectivePeriod>
    <start value="2023-10-03T06:32:00+01:00" />
    <end value="2023-10-03T07:30:00+01:00" />
  </effectivePeriod>
  <performer>
    <reference value="Organization-Reference" />
  </performer>
  <performer>
    <reference value="Practitioner-Reference" />
  </performer>
  <result>
    <reference value="#Obs-1" />
  </result>
  <result>
    <reference value="#Obs-2" />
  </result>
  <result>
    <reference value="#Obs-3" />
  </result>
  <result>
    <reference value="#Obs-4" />
  </result>
  <result>
    <reference value="#Obs-5" />
  </result>
  <result>
    <reference value="#Obs-6" />
  </result>
  <result>
    <reference value="#Obs-7" />
  </result>
  <result>
    <reference value="#Obs-8" />
  </result>
  <result>
    <reference value="#Obs-9" />
  </result>
  <result>
    <reference value="#Obs-10" />
  </result>
  <result>
    <reference value="#Obs-11" />
  </result>
  <presentedForm>
    <contentType value="application/pdf" />
    <data value="QUdQIHJlcG9ydA==" />
    <url value="https://aws-cloud-location-of-AGP-Report" />
    <hash value="2c9fa2fc8f4fd1b3184821e27dfc0b6960724633" />
    <title value="AGP-Report" />
    <creation value="2023-10-03T07:30:00+01:00" />
  </presentedForm>