RDC Interoperability Guide
1.1.0

rdc-GuidanceResponse

Official URL: https://roche.com/fhir/iop/StructureDefinition/rdc-GuidanceResponse Version: 1.1.0
Parent:

http://hl7.org/fhir/StructureDefinition/GuidanceResponse

Computable Name:

RdcGuidanceResponse

RDC GuidanceResponse profile for formal responses to a guidance request.

Formal Views of Profile Content

requestIdentifier..0
identifier..0
encounter..0
occurrenceDateTime..0
performer..0
note..0
evaluationMessage..0
outputParameters..0
dataRequirement..0

GuidanceResponse.requestIdentifier
Cardinality..0
GuidanceResponse.identifier
Cardinality..0
GuidanceResponse.encounter
Cardinality..0
GuidanceResponse.occurrenceDateTime
Cardinality..0
GuidanceResponse.performer
Cardinality..0
GuidanceResponse.note
Cardinality..0
GuidanceResponse.evaluationMessage
Cardinality..0
GuidanceResponse.outputParameters
Cardinality..0
GuidanceResponse.dataRequirement
Cardinality..0
  • TODO
  • <StructureDefinition xmlns="http://hl7.org/fhir">
    <id value="rdc-GuidanceResponse" />
    <url value="https://roche.com/fhir/iop/StructureDefinition/rdc-GuidanceResponse" />
    <name value="RdcGuidanceResponse" />
    <title value="RDC GuidanceResponse" />
    <status value="draft" />
    <publisher value="F. Hoffmann-La Roche AG" />
    <description value="RDC GuidanceResponse profile for formal responses to a guidance request." />
    <purpose value="Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise." />
    <fhirVersion value="5.0.0" />
    <kind value="resource" />
    <abstract value="false" />
    <type value="GuidanceResponse" />
    <baseDefinition value="http://hl7.org/fhir/StructureDefinition/GuidanceResponse" />
    <derivation value="constraint" />
    <differential>
    <element id="GuidanceResponse.requestIdentifier">
    <path value="GuidanceResponse.requestIdentifier" />
    <max value="0" />
    </element>
    <element id="GuidanceResponse.identifier">
    <path value="GuidanceResponse.identifier" />
    <max value="0" />
    </element>
    <element id="GuidanceResponse.encounter">
    <path value="GuidanceResponse.encounter" />
    <max value="0" />
    </element>
    <element id="GuidanceResponse.occurrenceDateTime">
    <path value="GuidanceResponse.occurrenceDateTime" />
    <max value="0" />
    </element>
    <element id="GuidanceResponse.performer">
    <path value="GuidanceResponse.performer" />
    <max value="0" />
    </element>
    <element id="GuidanceResponse.note">
    <path value="GuidanceResponse.note" />
    <max value="0" />
    </element>
    <element id="GuidanceResponse.evaluationMessage">
    <path value="GuidanceResponse.evaluationMessage" />
    <max value="0" />
    </element>
    <element id="GuidanceResponse.outputParameters">
    <path value="GuidanceResponse.outputParameters" />
    <max value="0" />
    </element>
    <element id="GuidanceResponse.dataRequirement">
    <path value="GuidanceResponse.dataRequirement" />
    <max value="0" />
    </element>
    </differential>
    </StructureDefinition>
    {
    "resourceType": "StructureDefinition",
    "id": "rdc-GuidanceResponse",
    "url": "https://roche.com/fhir/iop/StructureDefinition/rdc-GuidanceResponse",
    "name": "RdcGuidanceResponse",
    "title": "RDC GuidanceResponse",
    "status": "draft",
    "publisher": "F. Hoffmann-La Roche AG",
    "description": "RDC GuidanceResponse profile for formal responses to a guidance request.",
    "purpose": "Copyright and related rights waived via CC0, https://creativecommons.org/publicdomain/zero/1.0/. This does not apply to information from third parties, for example a medical terminology system. The implementer alone is responsible for identifying and obtaining any necessary licenses or authorizations to utilize third party IP in connection with the specification or otherwise.",
    "fhirVersion": "5.0.0",
    "kind": "resource",
    "abstract": false,
    "type": "GuidanceResponse",
    "baseDefinition": "http://hl7.org/fhir/StructureDefinition/GuidanceResponse",
    "derivation": "constraint",
    "differential": {
    "element": [
    {
    "id": "GuidanceResponse.requestIdentifier",
    "path": "GuidanceResponse.requestIdentifier",
    "max": "0"
    },
    {
    "id": "GuidanceResponse.identifier",
    "path": "GuidanceResponse.identifier",
    "max": "0"
    },
    {
    "id": "GuidanceResponse.encounter",
    "path": "GuidanceResponse.encounter",
    "max": "0"
    },
    {
    "id": "GuidanceResponse.occurrenceDateTime",
    "path": "GuidanceResponse.occurrenceDateTime",
    "max": "0"
    },
    {
    "id": "GuidanceResponse.performer",
    "path": "GuidanceResponse.performer",
    "max": "0"
    },
    {
    "id": "GuidanceResponse.note",
    "path": "GuidanceResponse.note",
    "max": "0"
    },
    {
    "id": "GuidanceResponse.evaluationMessage",
    "path": "GuidanceResponse.evaluationMessage",
    "max": "0"
    },
    {
    "id": "GuidanceResponse.outputParameters",
    "path": "GuidanceResponse.outputParameters",
    "max": "0"
    },
    {
    "id": "GuidanceResponse.dataRequirement",
    "path": "GuidanceResponse.dataRequirement",
    "max": "0"
    }
    ]
    }
    }