RLObservationStiliVita
Descrizione
Il profilo RLObservationStiliVita è stato strutturato a partire dalla risorsa generica FHIR Observation ed è volto a contenere i dati raccolti riguardo gli stili di vita del paziente.
Di seguito è presentato il contenuto del profilo in diversi formati. La corrispondente definizione è consultabile al seguente link: RLObservationStiliVita.
Snapshot View
Observation | I | Observation | There are no (further) constraints on this element Element IdObservation Measurements and simple assertions Alternate namesVital Signs, Measurement, Results, Tests DefinitionMeasurements and simple assertions made about a patient, device or other subject. Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.
| |
id | Σ | 1..1 | System.String | Element IdObservation.id UUID prodotto dal server FHIR (applicativo) che detiente la risorsa DefinitionThe logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. The only time that a resource does not have an id is when it is being submitted to the server using a create operation. System.String |
meta | Σ | 1..1 | Meta | Element IdObservation.meta Metadati della risorsa DefinitionThe metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.
|
versionId | Σ | 1..1 | id | Element IdObservation.meta.versionId Versione della risorsa DefinitionThe version specific identifier, as it appears in the version portion of the URL. This value changes when the resource is created, updated, or deleted. The server assigns this value, and ignores what the client specifies, except in the case that the server is imposing version integrity on updates/deletes.
|
lastUpdated | Σ | 1..1 | instant | Element IdObservation.meta.lastUpdated Data e ora di ultimo aggiornamento della risorsa DefinitionFormato standard FHIR: YYY-MM-DDThh:mm:ss.sss+zz:zz This value is always populated except when the resource is first being created. The server / resource manager sets this value; what a client provides is irrelevant. This is equivalent to the HTTP Last-Modified and SHOULD have the same value on a read interaction.
|
source | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdObservation.meta.source Identifies where the resource comes from DefinitionA uri that identifies the source system of the resource. This provides a minimal amount of Provenance information that can be used to track or differentiate the source of information in the resource. The source may identify another FHIR server, document, message, database, etc. In the provenance resource, this corresponds to Provenance.entity.what[x]. The exact use of the source (and the implied Provenance.entity.role) is left to implementer discretion. Only one nominated source is allowed; for additional provenance details, a full Provenance resource should be used. This element can be used to indicate where the current master source of a resource that has a canonical URL if the resource is no longer hosted at the canonical URL.
|
profile | Σ | 1..1 | canonical(StructureDefinition)Fixed Value | Element IdObservation.meta.profile Profilo al quale la risorsa si riferisce DefinitionA list of profiles (references to StructureDefinition resources) that this resource claims to conform to. The URL is a reference to StructureDefinition.url. It is up to the server and/or other infrastructure of policy to determine whether/how these claims are verified and/or updated over time. The list of profile URLs is a set. canonical(StructureDefinition) Constraints
https://fhir.siss.regione.lombardia.it/StructureDefinition/RLObservationStiliVita
|
security | Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element IdObservation.meta.security Security Labels applied to this resource DefinitionSecurity labels applied to this resource. These tags connect specific resources to the overall security policy and infrastructure. The security labels can be updated without changing the stated version of the resource. The list of security labels is a set. Uniqueness is based the system/code, and version and display are ignored. Security Labels from the Healthcare Privacy and Security Classification System. All Security Labels (extensible)Constraints
|
tag | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdObservation.meta.tag Tags applied to this resource DefinitionTags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource. The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored. Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones". CommonTags (example)Constraints
|
identifier | Σ | 0..* | Identifier | There are no (further) constraints on this element Element IdObservation.identifier Business Identifier for observation DefinitionA unique identifier assigned to this observation. Allows observations to be distinguished and referenced.
|
basedOn | Σ I | 1..1 | Reference(RLCarePlanProgettoIndividuale) | Element IdObservation.basedOn Riferimento al progetto individuale nel quale è prevista l'erogazione della prestazione Alternate namesFulfills DefinitionReference al profilo RLCarePlanProgettoIndividuale contenente il progetto individuale del paziente Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon. Il dato è detenuto dal SGDT Reference(RLCarePlanProgettoIndividuale) Constraints
|
partOf | Σ I | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | There are no (further) constraints on this element Element IdObservation.partOf Part of referenced event Alternate namesContainer DefinitionA larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure. To link an Observation to an Encounter use Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Constraints
|
status | Σ ?! | 1..1 | codeBindingFixed Value | Element IdObservation.status Stato della registrazione dello stile di vita DefinitionValore fisso su "final" Need to track the status of individual results. Some results are finalized before the whole report is finalized. This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid. Codes providing the status of an observation. ObservationStatus (required)Constraints
final
|
category | 1..1 | CodeableConceptBindingFixed Value | Element IdObservation.category Classificazione della registrazione dello stile di vita DefinitionValore fisso su "social-history" cosi come previsto dal value-set dello standard FHIR Used for filtering what observations are retrieved and displayed. In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set. Codes for high level observation categories. ObservationCategoryCodes (preferred)Constraints
{ "text": "social-history" }
| |
code | Σ | 1..1 | CodeableConcept | Element IdObservation.code Codifica dello stile di vita Alternate namesName DefinitionDescribes what was observed. Sometimes this is called the observation "name". Knowing what kind of observation is being made is essential to understanding the observation. Per il dettaglio esaustivo della codifica consultare la Tabella degli stili di vita contenuta nella sezione dei value-set del profilo presente nell'Implementation Guide. Codes identifying names of simple observations. LOINCCodes (example)Constraints
|
coding | Σ | 1..1 | Coding | Element IdObservation.code.coding Le tipologie dello stile di vita sono: fumo, alcol, sedentarietà ed eccesso ponderale DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdObservation.code.coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.code.coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | codeBinding | Element IdObservation.code.coding.code Codice della tipologia dello stile di vita DefinitionCodice numerico di 2 cifre Need to refer to a particular code in the system. Il dato è detenuto dal SGDT ValueSet relativo agli stili di vita SGDT Stili Vita (required)Constraints
|
display | Σ | 1..1 | string | Element IdObservation.code.coding.display Descrizione della tipologia dello stile di vita DefinitionStringa alfabetica di al più 50 caratteri Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdObservation.code.coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.code.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
subject | Σ I | 1..1 | Reference(RLPatientCittadino) | Element IdObservation.subject Paziente al quale è stata diagnosticata la patologia DefinitionReference alla risorsa RLPatientCittadino contenente i dettagli anagrafici del paziente Observations have no value if you don't know who or what they're about. Il dato è detenuto dal SGDT
|
focus | Σ I | 0..* | Reference(Resource) | There are no (further) constraints on this element Element IdObservation.focus What the observation is about, when it is not about the subject of record DefinitionThe actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus. Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use
|
encounter | Σ I | 0..1 | Reference(Encounter) | There are no (further) constraints on this element Element IdObservation.encounter Healthcare event during which this observation is made Alternate namesContext DefinitionThe healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made. For some observations it may be important to know the link between an observation and a particular encounter. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests).
|
effective[x] | Σ | 0..1 | Element IdObservation.effective[x] Data e ora di registrazione dello stile di vita Alternate namesOccurrence DefinitionFormato: YYYY-MM-DDThh:mm:ss+zz:zz secondo lo standard FHIR Knowing when an observation was deemed true is important to its relevance as well as determining trends. Il dato è detenuto dal SGDT
| |
effectiveDateTime | dateTime | Data Type | ||
issued | Σ | 0..1 | instant | There are no (further) constraints on this element Element IdObservation.issued Date/Time this version was made available DefinitionThe date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified. For Observations that don’t require review and verification, it may be the same as the
|
performer | Σ I | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | There are no (further) constraints on this element Element IdObservation.performer Who is responsible for the observation DefinitionWho was responsible for asserting the observed value as "true". May give a degree of confidence in the observation and also indicates where follow-up questions should be directed. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Constraints
|
value[x] | Σ I | 1..1 | Element IdObservation.value[x] Codifica e descrizione dello stato relativo al corrispondende stile di vita DefinitionCodifica in fase di definizione An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations. Il dato è detenuto dal SGDT
| |
valueCodeableConcept | CodeableConcept | Data Type | ||
coding | Σ | 1..1 | Coding | Element IdObservation.value[x].coding Codifica e descrizione dello stato relativo al corrispondende stile di vita DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdObservation.value[x].coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.value[x].coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | Element IdObservation.value[x].coding.code Codice dell'osservazione sullo stile di vita DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Il dato è detenuto dal SGDT.
|
display | Σ | 1..1 | string | Element IdObservation.value[x].coding.display Codice dell'osservazione sullo stile di vita DefinitionStringa alfanumerica di al più 1000 caratteri Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Il dato è detenuto dal SGDT
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdObservation.value[x].coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.value[x].text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
dataAbsentReason | I | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.dataAbsentReason Why the result is missing DefinitionProvides a reason why the expected value in the element Observation.value[x] is missing. For many results it is necessary to handle exceptional values in measurements. Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values. Codes specifying why the result (`Observation.value[x]`) is missing. DataAbsentReason (extensible)Constraints
|
interpretation | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.interpretation High, low, normal, etc. Alternate namesAbnormal Flag DefinitionA categorical assessment of an observation value. For example, high, low, normal. For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result. Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result. Codes identifying interpretations of observations. ObservationInterpretationCodes (extensible)Constraints
| |
note | 0..* | Annotation | There are no (further) constraints on this element Element IdObservation.note Comments about the observation DefinitionComments about the observation or the results. Need to be able to provide free text additional information. May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation.
| |
bodySite | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdObservation.bodySite Observed body part DefinitionIndicates the site on the subject's body where the observation was made (i.e. the target site). Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension bodySite. Codes describing anatomical locations. May include laterality. SNOMEDCTBodyStructures (example)Constraints
| |
method | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdObservation.method How it was done DefinitionIndicates the mechanism used to perform the observation. In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results. Only used if not implicit in code for Observation.code. Methods for simple observations. ObservationMethods (example)Constraints
| |
specimen | I | 0..1 | Reference(Specimen) | There are no (further) constraints on this element Element IdObservation.specimen Specimen used for this observation DefinitionThe specimen that was used when this observation was made. Should only be used if not implicit in code found in
|
device | I | 0..1 | Reference(Device | DeviceMetric) | There are no (further) constraints on this element Element IdObservation.device (Measurement) Device DefinitionThe device used to generate the observation data. Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant. Reference(Device | DeviceMetric) Constraints
|
referenceRange | I | 0..* | BackboneElement | There are no (further) constraints on this element Element IdObservation.referenceRange Provides guide for interpretation DefinitionGuidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts. Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.
|
low | I | 0..1 | SimpleQuantity | There are no (further) constraints on this element Element IdObservation.referenceRange.low Low Range, if relevant DefinitionThe value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3). The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.
|
high | I | 0..1 | SimpleQuantity | There are no (further) constraints on this element Element IdObservation.referenceRange.high High Range, if relevant DefinitionThe value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3). The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.
|
type | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.referenceRange.type Reference range qualifier DefinitionCodes to indicate the what part of the targeted reference population it applies to. For example, the normal or therapeutic range. Need to be able to say what kind of reference range this is - normal, recommended, therapeutic, etc., - for proper interpretation. This SHOULD be populated if there is more than one range. If this element is not present then the normal range is assumed. Code for the meaning of a reference range. ObservationReferenceRangeMeaningCodes (preferred)Constraints
| |
appliesTo | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdObservation.referenceRange.appliesTo Reference range population DefinitionCodes to indicate the target population this reference range applies to. For example, a reference range may be based on the normal population or a particular sex or race. Multiple Need to be able to identify the target population for proper interpretation. This SHOULD be populated if there is more than one range. If this element is not present then the normal population is assumed. Codes identifying the population the reference range applies to. ObservationReferenceRangeAppliesToCodes (example)Constraints
| |
age | I | 0..1 | Range | There are no (further) constraints on this element Element IdObservation.referenceRange.age Applicable age range, if relevant DefinitionThe age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so. Some analytes vary greatly over age. The stated low and high value are assumed to have arbitrarily high precision when it comes to determining which values are in the range. I.e. 1.99 is not in the range 2 -> 3.
|
text | 0..1 | string | There are no (further) constraints on this element Element IdObservation.referenceRange.text Text based reference range in an observation DefinitionText based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of "normals". Note that FHIR strings SHALL NOT exceed 1MB in size
| |
hasMember | Σ I | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | There are no (further) constraints on this element Element IdObservation.hasMember Related resource that belongs to the Observation group DefinitionThis observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group. When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation. Reference(Observation | QuestionnaireResponse | MolecularSequence) Constraints
|
derivedFrom | Σ I | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | There are no (further) constraints on this element Element IdObservation.derivedFrom Related measurements the observation is made from DefinitionThe target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image. All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below. Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) Constraints
|
component | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdObservation.component Component results DefinitionSome observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations. Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation. For a discussion on the ways Observations can be assembled in groups together see Notes below.
|
code | Σ | 1..1 | CodeableConcept | There are no (further) constraints on this element Element IdObservation.component.code Type of component observation (code / type) DefinitionDescribes what was observed. Sometimes this is called the observation "code". Knowing what kind of observation is being made is essential to understanding the observation. All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. Codes identifying names of simple observations. LOINCCodes (example)Constraints
|
value[x] | Σ | 0..1 | There are no (further) constraints on this element Element IdObservation.component.value[x] Actual component result DefinitionThe information determined as a result of making the observation, if the information has a simple value. An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations. Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.
| |
valueQuantity | Quantity | There are no (further) constraints on this element Data Type | ||
valueCodeableConcept | CodeableConcept | There are no (further) constraints on this element Data Type | ||
valueString | string | There are no (further) constraints on this element Data Type | ||
valueBoolean | boolean | There are no (further) constraints on this element Data Type | ||
valueInteger | integer | There are no (further) constraints on this element Data Type | ||
valueRange | Range | There are no (further) constraints on this element Data Type | ||
valueRatio | Ratio | There are no (further) constraints on this element Data Type | ||
valueSampledData | SampledData | There are no (further) constraints on this element Data Type | ||
valueTime | time | There are no (further) constraints on this element Data Type | ||
valueDateTime | dateTime | There are no (further) constraints on this element Data Type | ||
valuePeriod | Period | There are no (further) constraints on this element Data Type | ||
dataAbsentReason | I | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.component.dataAbsentReason Why the component result is missing DefinitionProvides a reason why the expected value in the element Observation.component.value[x] is missing. For many results it is necessary to handle exceptional values in measurements. "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values. Codes specifying why the result (`Observation.value[x]`) is missing. DataAbsentReason (extensible)Constraints
|
interpretation | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.component.interpretation High, low, normal, etc. Alternate namesAbnormal Flag DefinitionA categorical assessment of an observation value. For example, high, low, normal. For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result. Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result. Codes identifying interpretations of observations. ObservationInterpretationCodes (extensible)Constraints
| |
referenceRange | 0..* | see (referenceRange) | There are no (further) constraints on this element Element IdObservation.component.referenceRange Provides guide for interpretation of component result DefinitionGuidance on how to interpret the value by comparison to a normal or recommended range. Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts. Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.
|
Differential View
Observation | I | Observation | There are no (further) constraints on this element Element IdObservation Measurements and simple assertions Alternate namesVital Signs, Measurement, Results, Tests DefinitionMeasurements and simple assertions made about a patient, device or other subject. Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.
| |
id | Σ | 1..1 | System.String | Element IdObservation.id UUID prodotto dal server FHIR (applicativo) che detiente la risorsa DefinitionThe logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. The only time that a resource does not have an id is when it is being submitted to the server using a create operation. System.String |
meta | Σ | 1..1 | Meta | Element IdObservation.meta Metadati della risorsa DefinitionThe metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.
|
versionId | Σ | 1..1 | id | Element IdObservation.meta.versionId Versione della risorsa DefinitionThe version specific identifier, as it appears in the version portion of the URL. This value changes when the resource is created, updated, or deleted. The server assigns this value, and ignores what the client specifies, except in the case that the server is imposing version integrity on updates/deletes.
|
lastUpdated | Σ | 1..1 | instant | Element IdObservation.meta.lastUpdated Data e ora di ultimo aggiornamento della risorsa DefinitionFormato standard FHIR: YYY-MM-DDThh:mm:ss.sss+zz:zz This value is always populated except when the resource is first being created. The server / resource manager sets this value; what a client provides is irrelevant. This is equivalent to the HTTP Last-Modified and SHOULD have the same value on a read interaction.
|
source | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdObservation.meta.source Identifies where the resource comes from DefinitionA uri that identifies the source system of the resource. This provides a minimal amount of Provenance information that can be used to track or differentiate the source of information in the resource. The source may identify another FHIR server, document, message, database, etc. In the provenance resource, this corresponds to Provenance.entity.what[x]. The exact use of the source (and the implied Provenance.entity.role) is left to implementer discretion. Only one nominated source is allowed; for additional provenance details, a full Provenance resource should be used. This element can be used to indicate where the current master source of a resource that has a canonical URL if the resource is no longer hosted at the canonical URL.
|
profile | Σ | 1..1 | canonical(StructureDefinition)Fixed Value | Element IdObservation.meta.profile Profilo al quale la risorsa si riferisce DefinitionA list of profiles (references to StructureDefinition resources) that this resource claims to conform to. The URL is a reference to StructureDefinition.url. It is up to the server and/or other infrastructure of policy to determine whether/how these claims are verified and/or updated over time. The list of profile URLs is a set. canonical(StructureDefinition) Constraints
https://fhir.siss.regione.lombardia.it/StructureDefinition/RLObservationStiliVita
|
security | Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element IdObservation.meta.security Security Labels applied to this resource DefinitionSecurity labels applied to this resource. These tags connect specific resources to the overall security policy and infrastructure. The security labels can be updated without changing the stated version of the resource. The list of security labels is a set. Uniqueness is based the system/code, and version and display are ignored. Security Labels from the Healthcare Privacy and Security Classification System. All Security Labels (extensible)Constraints
|
tag | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdObservation.meta.tag Tags applied to this resource DefinitionTags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource. The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored. Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones". CommonTags (example)Constraints
|
identifier | Σ | 0..* | Identifier | There are no (further) constraints on this element Element IdObservation.identifier Business Identifier for observation DefinitionA unique identifier assigned to this observation. Allows observations to be distinguished and referenced.
|
basedOn | Σ I | 1..1 | Reference(RLCarePlanProgettoIndividuale) | Element IdObservation.basedOn Riferimento al progetto individuale nel quale è prevista l'erogazione della prestazione Alternate namesFulfills DefinitionReference al profilo RLCarePlanProgettoIndividuale contenente il progetto individuale del paziente Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon. Il dato è detenuto dal SGDT Reference(RLCarePlanProgettoIndividuale) Constraints
|
partOf | Σ I | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | There are no (further) constraints on this element Element IdObservation.partOf Part of referenced event Alternate namesContainer DefinitionA larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure. To link an Observation to an Encounter use Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Constraints
|
status | Σ ?! | 1..1 | codeBindingFixed Value | Element IdObservation.status Stato della registrazione dello stile di vita DefinitionValore fisso su "final" Need to track the status of individual results. Some results are finalized before the whole report is finalized. This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid. Codes providing the status of an observation. ObservationStatus (required)Constraints
final
|
category | 1..1 | CodeableConceptBindingFixed Value | Element IdObservation.category Classificazione della registrazione dello stile di vita DefinitionValore fisso su "social-history" cosi come previsto dal value-set dello standard FHIR Used for filtering what observations are retrieved and displayed. In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set. Codes for high level observation categories. ObservationCategoryCodes (preferred)Constraints
{ "text": "social-history" }
| |
code | Σ | 1..1 | CodeableConcept | Element IdObservation.code Codifica dello stile di vita Alternate namesName DefinitionDescribes what was observed. Sometimes this is called the observation "name". Knowing what kind of observation is being made is essential to understanding the observation. Per il dettaglio esaustivo della codifica consultare la Tabella degli stili di vita contenuta nella sezione dei value-set del profilo presente nell'Implementation Guide. Codes identifying names of simple observations. LOINCCodes (example)Constraints
|
coding | Σ | 1..1 | Coding | Element IdObservation.code.coding Le tipologie dello stile di vita sono: fumo, alcol, sedentarietà ed eccesso ponderale DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdObservation.code.coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.code.coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | codeBinding | Element IdObservation.code.coding.code Codice della tipologia dello stile di vita DefinitionCodice numerico di 2 cifre Need to refer to a particular code in the system. Il dato è detenuto dal SGDT ValueSet relativo agli stili di vita SGDT Stili Vita (required)Constraints
|
display | Σ | 1..1 | string | Element IdObservation.code.coding.display Descrizione della tipologia dello stile di vita DefinitionStringa alfabetica di al più 50 caratteri Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdObservation.code.coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.code.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
subject | Σ I | 1..1 | Reference(RLPatientCittadino) | Element IdObservation.subject Paziente al quale è stata diagnosticata la patologia DefinitionReference alla risorsa RLPatientCittadino contenente i dettagli anagrafici del paziente Observations have no value if you don't know who or what they're about. Il dato è detenuto dal SGDT
|
focus | Σ I | 0..* | Reference(Resource) | There are no (further) constraints on this element Element IdObservation.focus What the observation is about, when it is not about the subject of record DefinitionThe actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus. Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use
|
encounter | Σ I | 0..1 | Reference(Encounter) | There are no (further) constraints on this element Element IdObservation.encounter Healthcare event during which this observation is made Alternate namesContext DefinitionThe healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made. For some observations it may be important to know the link between an observation and a particular encounter. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests).
|
effective[x] | Σ | 0..1 | Element IdObservation.effective[x] Data e ora di registrazione dello stile di vita Alternate namesOccurrence DefinitionFormato: YYYY-MM-DDThh:mm:ss+zz:zz secondo lo standard FHIR Knowing when an observation was deemed true is important to its relevance as well as determining trends. Il dato è detenuto dal SGDT
| |
effectiveDateTime | dateTime | Data Type | ||
issued | Σ | 0..1 | instant | There are no (further) constraints on this element Element IdObservation.issued Date/Time this version was made available DefinitionThe date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified. For Observations that don’t require review and verification, it may be the same as the
|
performer | Σ I | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | There are no (further) constraints on this element Element IdObservation.performer Who is responsible for the observation DefinitionWho was responsible for asserting the observed value as "true". May give a degree of confidence in the observation and also indicates where follow-up questions should be directed. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Constraints
|
value[x] | Σ I | 1..1 | Element IdObservation.value[x] Codifica e descrizione dello stato relativo al corrispondende stile di vita DefinitionCodifica in fase di definizione An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations. Il dato è detenuto dal SGDT
| |
valueCodeableConcept | CodeableConcept | Data Type | ||
coding | Σ | 1..1 | Coding | Element IdObservation.value[x].coding Codifica e descrizione dello stato relativo al corrispondende stile di vita DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdObservation.value[x].coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.value[x].coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | Element IdObservation.value[x].coding.code Codice dell'osservazione sullo stile di vita DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Il dato è detenuto dal SGDT.
|
display | Σ | 1..1 | string | Element IdObservation.value[x].coding.display Codice dell'osservazione sullo stile di vita DefinitionStringa alfanumerica di al più 1000 caratteri Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Il dato è detenuto dal SGDT
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdObservation.value[x].coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.value[x].text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
dataAbsentReason | I | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.dataAbsentReason Why the result is missing DefinitionProvides a reason why the expected value in the element Observation.value[x] is missing. For many results it is necessary to handle exceptional values in measurements. Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values. Codes specifying why the result (`Observation.value[x]`) is missing. DataAbsentReason (extensible)Constraints
|
interpretation | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.interpretation High, low, normal, etc. Alternate namesAbnormal Flag DefinitionA categorical assessment of an observation value. For example, high, low, normal. For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result. Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result. Codes identifying interpretations of observations. ObservationInterpretationCodes (extensible)Constraints
| |
note | 0..* | Annotation | There are no (further) constraints on this element Element IdObservation.note Comments about the observation DefinitionComments about the observation or the results. Need to be able to provide free text additional information. May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation.
| |
bodySite | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdObservation.bodySite Observed body part DefinitionIndicates the site on the subject's body where the observation was made (i.e. the target site). Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension bodySite. Codes describing anatomical locations. May include laterality. SNOMEDCTBodyStructures (example)Constraints
| |
method | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdObservation.method How it was done DefinitionIndicates the mechanism used to perform the observation. In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results. Only used if not implicit in code for Observation.code. Methods for simple observations. ObservationMethods (example)Constraints
| |
specimen | I | 0..1 | Reference(Specimen) | There are no (further) constraints on this element Element IdObservation.specimen Specimen used for this observation DefinitionThe specimen that was used when this observation was made. Should only be used if not implicit in code found in
|
device | I | 0..1 | Reference(Device | DeviceMetric) | There are no (further) constraints on this element Element IdObservation.device (Measurement) Device DefinitionThe device used to generate the observation data. Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant. Reference(Device | DeviceMetric) Constraints
|
referenceRange | I | 0..* | BackboneElement | There are no (further) constraints on this element Element IdObservation.referenceRange Provides guide for interpretation DefinitionGuidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts. Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.
|
low | I | 0..1 | SimpleQuantity | There are no (further) constraints on this element Element IdObservation.referenceRange.low Low Range, if relevant DefinitionThe value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3). The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.
|
high | I | 0..1 | SimpleQuantity | There are no (further) constraints on this element Element IdObservation.referenceRange.high High Range, if relevant DefinitionThe value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3). The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.
|
type | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.referenceRange.type Reference range qualifier DefinitionCodes to indicate the what part of the targeted reference population it applies to. For example, the normal or therapeutic range. Need to be able to say what kind of reference range this is - normal, recommended, therapeutic, etc., - for proper interpretation. This SHOULD be populated if there is more than one range. If this element is not present then the normal range is assumed. Code for the meaning of a reference range. ObservationReferenceRangeMeaningCodes (preferred)Constraints
| |
appliesTo | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdObservation.referenceRange.appliesTo Reference range population DefinitionCodes to indicate the target population this reference range applies to. For example, a reference range may be based on the normal population or a particular sex or race. Multiple Need to be able to identify the target population for proper interpretation. This SHOULD be populated if there is more than one range. If this element is not present then the normal population is assumed. Codes identifying the population the reference range applies to. ObservationReferenceRangeAppliesToCodes (example)Constraints
| |
age | I | 0..1 | Range | There are no (further) constraints on this element Element IdObservation.referenceRange.age Applicable age range, if relevant DefinitionThe age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so. Some analytes vary greatly over age. The stated low and high value are assumed to have arbitrarily high precision when it comes to determining which values are in the range. I.e. 1.99 is not in the range 2 -> 3.
|
text | 0..1 | string | There are no (further) constraints on this element Element IdObservation.referenceRange.text Text based reference range in an observation DefinitionText based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of "normals". Note that FHIR strings SHALL NOT exceed 1MB in size
| |
hasMember | Σ I | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | There are no (further) constraints on this element Element IdObservation.hasMember Related resource that belongs to the Observation group DefinitionThis observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group. When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation. Reference(Observation | QuestionnaireResponse | MolecularSequence) Constraints
|
derivedFrom | Σ I | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | There are no (further) constraints on this element Element IdObservation.derivedFrom Related measurements the observation is made from DefinitionThe target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image. All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below. Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) Constraints
|
component | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdObservation.component Component results DefinitionSome observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations. Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation. For a discussion on the ways Observations can be assembled in groups together see Notes below.
|
code | Σ | 1..1 | CodeableConcept | There are no (further) constraints on this element Element IdObservation.component.code Type of component observation (code / type) DefinitionDescribes what was observed. Sometimes this is called the observation "code". Knowing what kind of observation is being made is essential to understanding the observation. All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. Codes identifying names of simple observations. LOINCCodes (example)Constraints
|
value[x] | Σ | 0..1 | There are no (further) constraints on this element Element IdObservation.component.value[x] Actual component result DefinitionThe information determined as a result of making the observation, if the information has a simple value. An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations. Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.
| |
valueQuantity | Quantity | There are no (further) constraints on this element Data Type | ||
valueCodeableConcept | CodeableConcept | There are no (further) constraints on this element Data Type | ||
valueString | string | There are no (further) constraints on this element Data Type | ||
valueBoolean | boolean | There are no (further) constraints on this element Data Type | ||
valueInteger | integer | There are no (further) constraints on this element Data Type | ||
valueRange | Range | There are no (further) constraints on this element Data Type | ||
valueRatio | Ratio | There are no (further) constraints on this element Data Type | ||
valueSampledData | SampledData | There are no (further) constraints on this element Data Type | ||
valueTime | time | There are no (further) constraints on this element Data Type | ||
valueDateTime | dateTime | There are no (further) constraints on this element Data Type | ||
valuePeriod | Period | There are no (further) constraints on this element Data Type | ||
dataAbsentReason | I | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.component.dataAbsentReason Why the component result is missing DefinitionProvides a reason why the expected value in the element Observation.component.value[x] is missing. For many results it is necessary to handle exceptional values in measurements. "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values. Codes specifying why the result (`Observation.value[x]`) is missing. DataAbsentReason (extensible)Constraints
|
interpretation | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.component.interpretation High, low, normal, etc. Alternate namesAbnormal Flag DefinitionA categorical assessment of an observation value. For example, high, low, normal. For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result. Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result. Codes identifying interpretations of observations. ObservationInterpretationCodes (extensible)Constraints
| |
referenceRange | 0..* | see (referenceRange) | There are no (further) constraints on this element Element IdObservation.component.referenceRange Provides guide for interpretation of component result DefinitionGuidance on how to interpret the value by comparison to a normal or recommended range. Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts. Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.
|
Hybrid View
Observation | I | Observation | There are no (further) constraints on this element Element IdObservation Measurements and simple assertions Alternate namesVital Signs, Measurement, Results, Tests DefinitionMeasurements and simple assertions made about a patient, device or other subject. Used for simple observations such as device measurements, laboratory atomic results, vital signs, height, weight, smoking status, comments, etc. Other resources are used to provide context for observations such as laboratory reports, etc.
| |
id | Σ | 1..1 | System.String | Element IdObservation.id UUID prodotto dal server FHIR (applicativo) che detiente la risorsa DefinitionThe logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. The only time that a resource does not have an id is when it is being submitted to the server using a create operation. System.String |
meta | Σ | 1..1 | Meta | Element IdObservation.meta Metadati della risorsa DefinitionThe metadata about the resource. This is content that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.
|
versionId | Σ | 1..1 | id | Element IdObservation.meta.versionId Versione della risorsa DefinitionThe version specific identifier, as it appears in the version portion of the URL. This value changes when the resource is created, updated, or deleted. The server assigns this value, and ignores what the client specifies, except in the case that the server is imposing version integrity on updates/deletes.
|
lastUpdated | Σ | 1..1 | instant | Element IdObservation.meta.lastUpdated Data e ora di ultimo aggiornamento della risorsa DefinitionFormato standard FHIR: YYY-MM-DDThh:mm:ss.sss+zz:zz This value is always populated except when the resource is first being created. The server / resource manager sets this value; what a client provides is irrelevant. This is equivalent to the HTTP Last-Modified and SHOULD have the same value on a read interaction.
|
source | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdObservation.meta.source Identifies where the resource comes from DefinitionA uri that identifies the source system of the resource. This provides a minimal amount of Provenance information that can be used to track or differentiate the source of information in the resource. The source may identify another FHIR server, document, message, database, etc. In the provenance resource, this corresponds to Provenance.entity.what[x]. The exact use of the source (and the implied Provenance.entity.role) is left to implementer discretion. Only one nominated source is allowed; for additional provenance details, a full Provenance resource should be used. This element can be used to indicate where the current master source of a resource that has a canonical URL if the resource is no longer hosted at the canonical URL.
|
profile | Σ | 1..1 | canonical(StructureDefinition)Fixed Value | Element IdObservation.meta.profile Profilo al quale la risorsa si riferisce DefinitionA list of profiles (references to StructureDefinition resources) that this resource claims to conform to. The URL is a reference to StructureDefinition.url. It is up to the server and/or other infrastructure of policy to determine whether/how these claims are verified and/or updated over time. The list of profile URLs is a set. canonical(StructureDefinition) Constraints
https://fhir.siss.regione.lombardia.it/StructureDefinition/RLObservationStiliVita
|
security | Σ | 0..* | CodingBinding | There are no (further) constraints on this element Element IdObservation.meta.security Security Labels applied to this resource DefinitionSecurity labels applied to this resource. These tags connect specific resources to the overall security policy and infrastructure. The security labels can be updated without changing the stated version of the resource. The list of security labels is a set. Uniqueness is based the system/code, and version and display are ignored. Security Labels from the Healthcare Privacy and Security Classification System. All Security Labels (extensible)Constraints
|
tag | Σ | 0..* | Coding | There are no (further) constraints on this element Element IdObservation.meta.tag Tags applied to this resource DefinitionTags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource. The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored. Codes that represent various types of tags, commonly workflow-related; e.g. "Needs review by Dr. Jones". CommonTags (example)Constraints
|
identifier | Σ | 0..* | Identifier | There are no (further) constraints on this element Element IdObservation.identifier Business Identifier for observation DefinitionA unique identifier assigned to this observation. Allows observations to be distinguished and referenced.
|
basedOn | Σ I | 1..1 | Reference(RLCarePlanProgettoIndividuale) | Element IdObservation.basedOn Riferimento al progetto individuale nel quale è prevista l'erogazione della prestazione Alternate namesFulfills DefinitionReference al profilo RLCarePlanProgettoIndividuale contenente il progetto individuale del paziente Allows tracing of authorization for the event and tracking whether proposals/recommendations were acted upon. Il dato è detenuto dal SGDT Reference(RLCarePlanProgettoIndividuale) Constraints
|
partOf | Σ I | 0..* | Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) | There are no (further) constraints on this element Element IdObservation.partOf Part of referenced event Alternate namesContainer DefinitionA larger event of which this particular Observation is a component or step. For example, an observation as part of a procedure. To link an Observation to an Encounter use Reference(MedicationAdministration | MedicationDispense | MedicationStatement | Procedure | Immunization | ImagingStudy) Constraints
|
status | Σ ?! | 1..1 | codeBindingFixed Value | Element IdObservation.status Stato della registrazione dello stile di vita DefinitionValore fisso su "final" Need to track the status of individual results. Some results are finalized before the whole report is finalized. This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid. Codes providing the status of an observation. ObservationStatus (required)Constraints
final
|
category | 1..1 | CodeableConceptBindingFixed Value | Element IdObservation.category Classificazione della registrazione dello stile di vita DefinitionValore fisso su "social-history" cosi come previsto dal value-set dello standard FHIR Used for filtering what observations are retrieved and displayed. In addition to the required category valueset, this element allows various categorization schemes based on the owner’s definition of the category and effectively multiple categories can be used at once. The level of granularity is defined by the category concepts in the value set. Codes for high level observation categories. ObservationCategoryCodes (preferred)Constraints
{ "text": "social-history" }
| |
code | Σ | 1..1 | CodeableConcept | Element IdObservation.code Codifica dello stile di vita Alternate namesName DefinitionDescribes what was observed. Sometimes this is called the observation "name". Knowing what kind of observation is being made is essential to understanding the observation. Per il dettaglio esaustivo della codifica consultare la Tabella degli stili di vita contenuta nella sezione dei value-set del profilo presente nell'Implementation Guide. Codes identifying names of simple observations. LOINCCodes (example)Constraints
|
coding | Σ | 1..1 | Coding | Element IdObservation.code.coding Le tipologie dello stile di vita sono: fumo, alcol, sedentarietà ed eccesso ponderale DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdObservation.code.coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.code.coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | codeBinding | Element IdObservation.code.coding.code Codice della tipologia dello stile di vita DefinitionCodice numerico di 2 cifre Need to refer to a particular code in the system. Il dato è detenuto dal SGDT ValueSet relativo agli stili di vita SGDT Stili Vita (required)Constraints
|
display | Σ | 1..1 | string | Element IdObservation.code.coding.display Descrizione della tipologia dello stile di vita DefinitionStringa alfabetica di al più 50 caratteri Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdObservation.code.coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.code.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
subject | Σ I | 1..1 | Reference(RLPatientCittadino) | Element IdObservation.subject Paziente al quale è stata diagnosticata la patologia DefinitionReference alla risorsa RLPatientCittadino contenente i dettagli anagrafici del paziente Observations have no value if you don't know who or what they're about. Il dato è detenuto dal SGDT
|
focus | Σ I | 0..* | Reference(Resource) | There are no (further) constraints on this element Element IdObservation.focus What the observation is about, when it is not about the subject of record DefinitionThe actual focus of an observation when it is not the patient of record representing something or someone associated with the patient such as a spouse, parent, fetus, or donor. For example, fetus observations in a mother's record. The focus of an observation could also be an existing condition, an intervention, the subject's diet, another observation of the subject, or a body structure such as tumor or implanted device. An example use case would be using the Observation resource to capture whether the mother is trained to change her child's tracheostomy tube. In this example, the child is the patient of record and the mother is the focus. Typically, an observation is made about the subject - a patient, or group of patients, location, or device - and the distinction between the subject and what is directly measured for an observation is specified in the observation code itself ( e.g., "Blood Glucose") and does not need to be represented separately using this element. Use
|
encounter | Σ I | 0..1 | Reference(Encounter) | There are no (further) constraints on this element Element IdObservation.encounter Healthcare event during which this observation is made Alternate namesContext DefinitionThe healthcare event (e.g. a patient and healthcare provider interaction) during which this observation is made. For some observations it may be important to know the link between an observation and a particular encounter. This will typically be the encounter the event occurred within, but some events may be initiated prior to or after the official completion of an encounter but still be tied to the context of the encounter (e.g. pre-admission laboratory tests).
|
effective[x] | Σ | 0..1 | Element IdObservation.effective[x] Data e ora di registrazione dello stile di vita Alternate namesOccurrence DefinitionFormato: YYYY-MM-DDThh:mm:ss+zz:zz secondo lo standard FHIR Knowing when an observation was deemed true is important to its relevance as well as determining trends. Il dato è detenuto dal SGDT
| |
effectiveDateTime | dateTime | Data Type | ||
issued | Σ | 0..1 | instant | There are no (further) constraints on this element Element IdObservation.issued Date/Time this version was made available DefinitionThe date and time this version of the observation was made available to providers, typically after the results have been reviewed and verified. For Observations that don’t require review and verification, it may be the same as the
|
performer | Σ I | 0..* | Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) | There are no (further) constraints on this element Element IdObservation.performer Who is responsible for the observation DefinitionWho was responsible for asserting the observed value as "true". May give a degree of confidence in the observation and also indicates where follow-up questions should be directed. References SHALL be a reference to an actual FHIR resource, and SHALL be resolveable (allowing for access control, temporary unavailability, etc.). Resolution can be either by retrieval from the URL, or, where applicable by resource type, by treating an absolute reference as a canonical URL and looking it up in a local registry/repository. Reference(Practitioner | PractitionerRole | Organization | CareTeam | Patient | RelatedPerson) Constraints
|
value[x] | Σ I | 1..1 | Element IdObservation.value[x] Codifica e descrizione dello stato relativo al corrispondende stile di vita DefinitionCodifica in fase di definizione An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations. Il dato è detenuto dal SGDT
| |
valueCodeableConcept | CodeableConcept | Data Type | ||
coding | Σ | 1..1 | Coding | Element IdObservation.value[x].coding Codifica e descrizione dello stato relativo al corrispondende stile di vita DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
system | Σ | 0..1 | uri | There are no (further) constraints on this element Element IdObservation.value[x].coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
|
version | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.value[x].coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | Element IdObservation.value[x].coding.code Codice dell'osservazione sullo stile di vita DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Il dato è detenuto dal SGDT.
|
display | Σ | 1..1 | string | Element IdObservation.value[x].coding.display Codice dell'osservazione sullo stile di vita DefinitionStringa alfanumerica di al più 1000 caratteri Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Il dato è detenuto dal SGDT
|
userSelected | Σ | 0..1 | boolean | There are no (further) constraints on this element Element IdObservation.value[x].coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element IdObservation.value[x].text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
dataAbsentReason | I | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.dataAbsentReason Why the result is missing DefinitionProvides a reason why the expected value in the element Observation.value[x] is missing. For many results it is necessary to handle exceptional values in measurements. Null or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "specimen unsatisfactory". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Note that an observation may only be reported if there are values to report. For example differential cell counts values may be reported only when > 0. Because of these options, use-case agreements are required to interpret general observations for null or exceptional values. Codes specifying why the result (`Observation.value[x]`) is missing. DataAbsentReason (extensible)Constraints
|
interpretation | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.interpretation High, low, normal, etc. Alternate namesAbnormal Flag DefinitionA categorical assessment of an observation value. For example, high, low, normal. For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result. Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result. Codes identifying interpretations of observations. ObservationInterpretationCodes (extensible)Constraints
| |
note | 0..* | Annotation | There are no (further) constraints on this element Element IdObservation.note Comments about the observation DefinitionComments about the observation or the results. Need to be able to provide free text additional information. May include general statements about the observation, or statements about significant, unexpected or unreliable results values, or information about its source when relevant to its interpretation.
| |
bodySite | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdObservation.bodySite Observed body part DefinitionIndicates the site on the subject's body where the observation was made (i.e. the target site). Only used if not implicit in code found in Observation.code. In many systems, this may be represented as a related observation instead of an inline component. If the use case requires BodySite to be handled as a separate resource (e.g. to identify and track separately) then use the standard extension bodySite. Codes describing anatomical locations. May include laterality. SNOMEDCTBodyStructures (example)Constraints
| |
method | 0..1 | CodeableConcept | There are no (further) constraints on this element Element IdObservation.method How it was done DefinitionIndicates the mechanism used to perform the observation. In some cases, method can impact results and is thus used for determining whether results can be compared or determining significance of results. Only used if not implicit in code for Observation.code. Methods for simple observations. ObservationMethods (example)Constraints
| |
specimen | I | 0..1 | Reference(Specimen) | There are no (further) constraints on this element Element IdObservation.specimen Specimen used for this observation DefinitionThe specimen that was used when this observation was made. Should only be used if not implicit in code found in
|
device | I | 0..1 | Reference(Device | DeviceMetric) | There are no (further) constraints on this element Element IdObservation.device (Measurement) Device DefinitionThe device used to generate the observation data. Note that this is not meant to represent a device involved in the transmission of the result, e.g., a gateway. Such devices may be documented using the Provenance resource where relevant. Reference(Device | DeviceMetric) Constraints
|
referenceRange | I | 0..* | BackboneElement | There are no (further) constraints on this element Element IdObservation.referenceRange Provides guide for interpretation DefinitionGuidance on how to interpret the value by comparison to a normal or recommended range. Multiple reference ranges are interpreted as an "OR". In other words, to represent two distinct target populations, two Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts. Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.
|
low | I | 0..1 | SimpleQuantity | There are no (further) constraints on this element Element IdObservation.referenceRange.low Low Range, if relevant DefinitionThe value of the low bound of the reference range. The low bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the low bound is omitted, it is assumed to be meaningless (e.g. reference range is <=2.3). The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.
|
high | I | 0..1 | SimpleQuantity | There are no (further) constraints on this element Element IdObservation.referenceRange.high High Range, if relevant DefinitionThe value of the high bound of the reference range. The high bound of the reference range endpoint is inclusive of the value (e.g. reference range is >=5 - <=9). If the high bound is omitted, it is assumed to be meaningless (e.g. reference range is >= 2.3). The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.
|
type | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.referenceRange.type Reference range qualifier DefinitionCodes to indicate the what part of the targeted reference population it applies to. For example, the normal or therapeutic range. Need to be able to say what kind of reference range this is - normal, recommended, therapeutic, etc., - for proper interpretation. This SHOULD be populated if there is more than one range. If this element is not present then the normal range is assumed. Code for the meaning of a reference range. ObservationReferenceRangeMeaningCodes (preferred)Constraints
| |
appliesTo | 0..* | CodeableConcept | There are no (further) constraints on this element Element IdObservation.referenceRange.appliesTo Reference range population DefinitionCodes to indicate the target population this reference range applies to. For example, a reference range may be based on the normal population or a particular sex or race. Multiple Need to be able to identify the target population for proper interpretation. This SHOULD be populated if there is more than one range. If this element is not present then the normal population is assumed. Codes identifying the population the reference range applies to. ObservationReferenceRangeAppliesToCodes (example)Constraints
| |
age | I | 0..1 | Range | There are no (further) constraints on this element Element IdObservation.referenceRange.age Applicable age range, if relevant DefinitionThe age at which this reference range is applicable. This is a neonatal age (e.g. number of weeks at term) if the meaning says so. Some analytes vary greatly over age. The stated low and high value are assumed to have arbitrarily high precision when it comes to determining which values are in the range. I.e. 1.99 is not in the range 2 -> 3.
|
text | 0..1 | string | There are no (further) constraints on this element Element IdObservation.referenceRange.text Text based reference range in an observation DefinitionText based reference range in an observation which may be used when a quantitative range is not appropriate for an observation. An example would be a reference value of "Negative" or a list or table of "normals". Note that FHIR strings SHALL NOT exceed 1MB in size
| |
hasMember | Σ I | 0..* | Reference(Observation | QuestionnaireResponse | MolecularSequence) | There are no (further) constraints on this element Element IdObservation.hasMember Related resource that belongs to the Observation group DefinitionThis observation is a group observation (e.g. a battery, a panel of tests, a set of vital sign measurements) that includes the target as a member of the group. When using this element, an observation will typically have either a value or a set of related resources, although both may be present in some cases. For a discussion on the ways Observations can assembled in groups together, see Notes below. Note that a system may calculate results from QuestionnaireResponse into a final score and represent the score as an Observation. Reference(Observation | QuestionnaireResponse | MolecularSequence) Constraints
|
derivedFrom | Σ I | 0..* | Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) | There are no (further) constraints on this element Element IdObservation.derivedFrom Related measurements the observation is made from DefinitionThe target resource that represents a measurement from which this observation value is derived. For example, a calculated anion gap or a fetal measurement based on an ultrasound image. All the reference choices that are listed in this element can represent clinical observations and other measurements that may be the source for a derived value. The most common reference will be another Observation. For a discussion on the ways Observations can assembled in groups together, see Notes below. Reference(DocumentReference | ImagingStudy | Media | QuestionnaireResponse | Observation | MolecularSequence) Constraints
|
component | Σ | 0..* | BackboneElement | There are no (further) constraints on this element Element IdObservation.component Component results DefinitionSome observations have multiple component observations. These component observations are expressed as separate code value pairs that share the same attributes. Examples include systolic and diastolic component observations for blood pressure measurement and multiple component observations for genetics observations. Component observations share the same attributes in the Observation resource as the primary observation and are always treated a part of a single observation (they are not separable). However, the reference range for the primary observation value is not inherited by the component values and is required when appropriate for each component observation. For a discussion on the ways Observations can be assembled in groups together see Notes below.
|
code | Σ | 1..1 | CodeableConcept | There are no (further) constraints on this element Element IdObservation.component.code Type of component observation (code / type) DefinitionDescribes what was observed. Sometimes this is called the observation "code". Knowing what kind of observation is being made is essential to understanding the observation. All code-value and component.code-component.value pairs need to be taken into account to correctly understand the meaning of the observation. Codes identifying names of simple observations. LOINCCodes (example)Constraints
|
value[x] | Σ | 0..1 | There are no (further) constraints on this element Element IdObservation.component.value[x] Actual component result DefinitionThe information determined as a result of making the observation, if the information has a simple value. An observation exists to have a value, though it might not if it is in error, or if it represents a group of observations. Used when observation has a set of component observations. An observation may have both a value (e.g. an Apgar score) and component observations (the observations from which the Apgar score was derived). If a value is present, the datatype for this element should be determined by Observation.code. A CodeableConcept with just a text would be used instead of a string if the field was usually coded, or if the type associated with the Observation.code defines a coded value. For additional guidance, see the Notes section below.
| |
valueQuantity | Quantity | There are no (further) constraints on this element Data Type | ||
valueCodeableConcept | CodeableConcept | There are no (further) constraints on this element Data Type | ||
valueString | string | There are no (further) constraints on this element Data Type | ||
valueBoolean | boolean | There are no (further) constraints on this element Data Type | ||
valueInteger | integer | There are no (further) constraints on this element Data Type | ||
valueRange | Range | There are no (further) constraints on this element Data Type | ||
valueRatio | Ratio | There are no (further) constraints on this element Data Type | ||
valueSampledData | SampledData | There are no (further) constraints on this element Data Type | ||
valueTime | time | There are no (further) constraints on this element Data Type | ||
valueDateTime | dateTime | There are no (further) constraints on this element Data Type | ||
valuePeriod | Period | There are no (further) constraints on this element Data Type | ||
dataAbsentReason | I | 0..1 | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.component.dataAbsentReason Why the component result is missing DefinitionProvides a reason why the expected value in the element Observation.component.value[x] is missing. For many results it is necessary to handle exceptional values in measurements. "Null" or exceptional values can be represented two ways in FHIR Observations. One way is to simply include them in the value set and represent the exceptions in the value. For example, measurement values for a serology test could be "detected", "not detected", "inconclusive", or "test not done". The alternate way is to use the value element for actual observations and use the explicit dataAbsentReason element to record exceptional values. For example, the dataAbsentReason code "error" could be used when the measurement was not completed. Because of these options, use-case agreements are required to interpret general observations for exceptional values. Codes specifying why the result (`Observation.value[x]`) is missing. DataAbsentReason (extensible)Constraints
|
interpretation | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element IdObservation.component.interpretation High, low, normal, etc. Alternate namesAbnormal Flag DefinitionA categorical assessment of an observation value. For example, high, low, normal. For some results, particularly numeric results, an interpretation is necessary to fully understand the significance of a result. Historically used for laboratory results (known as 'abnormal flag' ), its use extends to other use cases where coded interpretations are relevant. Often reported as one or more simple compact codes this element is often placed adjacent to the result value in reports and flow sheets to signal the meaning/normalcy status of the result. Codes identifying interpretations of observations. ObservationInterpretationCodes (extensible)Constraints
| |
referenceRange | 0..* | see (referenceRange) | There are no (further) constraints on this element Element IdObservation.component.referenceRange Provides guide for interpretation of component result DefinitionGuidance on how to interpret the value by comparison to a normal or recommended range. Knowing what values are considered "normal" can help evaluate the significance of a particular result. Need to be able to provide multiple reference ranges for different contexts. Most observations only have one generic reference range. Systems MAY choose to restrict to only supplying the relevant reference range based on knowledge about the patient (e.g., specific to the patient's age, gender, weight and other factors), but this might not be possible or appropriate. Whenever more than one reference range is supplied, the differences between them SHOULD be provided in the reference range and/or age properties.
|
Table View
Observation | .. | |
Observation.id | 1.. | |
Observation.meta | 1.. | |
Observation.meta.versionId | 1.. | |
Observation.meta.lastUpdated | 1.. | |
Observation.meta.profile | 1..1 | |
Observation.basedOn | Reference(RLCarePlanProgettoIndividuale) | 1..1 |
Observation.status | .. | |
Observation.category | 1..1 | |
Observation.code | .. | |
Observation.code.coding | 1..1 | |
Observation.code.coding.code | 1.. | |
Observation.code.coding.display | 1.. | |
Observation.subject | Reference(RLPatientCittadino) | 1.. |
Observation.effective[x] | dateTime | .. |
Observation.value[x] | CodeableConcept | 1.. |
Observation.value[x].coding | 1..1 | |
Observation.value[x].coding.code | 1.. | |
Observation.value[x].coding.display | 1.. |
XML View
<StructureDefinition xmlns="http://hl7.org/fhir"> <id value="RLObservationStiliVita" /> <meta> <lastUpdated value="2023-03-08T13:58:18.2997887+00:00" /> </meta> <url value="https://fhir.siss.regione.lombardia.it/StructureDefinition/RLObservationStiliVita" /> <name value="RLObservationStiliVita" /> <status value="active" /> <description value="Profilo volto a descrivere le osservazioni sugli stili di vita del paziente." /> <keyword> <system value="https://fhir.siss.regione.lombardia.it/CodeSystem/Tag" /> <code value="PI" /> </keyword> <fhirVersion value="4.0.1" /> <kind value="resource" /> <abstract value="false" /> <type value="Observation" /> <baseDefinition value="http://hl7.org/fhir/StructureDefinition/Observation" /> <derivation value="constraint" /> <differential> <element id="Observation.id"> <path value="Observation.id" /> <short value="UUID prodotto dal server FHIR (applicativo) che detiente la risorsa" /> <min value="1" /> </element> <element id="Observation.meta"> <path value="Observation.meta" /> <short value="Metadati della risorsa" /> <min value="1" /> </element> <element id="Observation.meta.versionId"> <path value="Observation.meta.versionId" /> <short value="Versione della risorsa" /> <min value="1" /> </element> <element id="Observation.meta.lastUpdated"> <path value="Observation.meta.lastUpdated" /> <short value="Data e ora di ultimo aggiornamento della risorsa" /> <definition value="Formato standard FHIR: YYY-MM-DDThh:mm:ss.sss+zz:zz" /> <min value="1" /> </element> <element id="Observation.meta.profile"> <path value="Observation.meta.profile" /> <short value="Profilo al quale la risorsa si riferisce" /> <min value="1" /> <max value="1" /> <fixedCanonical value="https://fhir.siss.regione.lombardia.it/StructureDefinition/RLObservationStiliVita" /> </element> <element id="Observation.basedOn"> <path value="Observation.basedOn" /> <short value="Riferimento al progetto individuale nel quale è prevista l'erogazione della prestazione" /> <definition value="Reference al profilo RLCarePlanProgettoIndividuale contenente il progetto individuale del paziente" /> <comment value="Il dato è detenuto dal SGDT" /> <min value="1" /> <max value="1" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.siss.regione.lombardia.it/StructureDefinition/RLCarePlanProgettoIndividuale" /> </type> </element> <element id="Observation.status"> <path value="Observation.status" /> <short value="Stato della registrazione dello stile di vita" /> <definition value="Valore fisso su "final"" /> <fixedCode value="final" /> </element> <element id="Observation.category"> <path value="Observation.category" /> <short value="Classificazione della registrazione dello stile di vita" /> <definition value="Valore fisso su "social-history" cosi come previsto dal value-set dello standard FHIR" /> <min value="1" /> <max value="1" /> <fixedCodeableConcept> <text value="social-history" /> </fixedCodeableConcept> </element> <element id="Observation.code"> <path value="Observation.code" /> <short value="Codifica dello stile di vita" /> <comment value="Per il dettaglio esaustivo della codifica consultare la Tabella degli stili di vita contenuta nella sezione dei value-set del profilo presente nell'Implementation Guide." /> </element> <element id="Observation.code.coding"> <path value="Observation.code.coding" /> <short value="Le tipologie dello stile di vita sono: fumo, alcol, sedentarietà ed eccesso ponderale" /> <min value="1" /> <max value="1" /> </element> <element id="Observation.code.coding.code"> <path value="Observation.code.coding.code" /> <short value="Codice della tipologia dello stile di vita" /> <definition value="Codice numerico di 2 cifre" /> <comment value="Il dato è detenuto dal SGDT" /> <min value="1" /> <binding> <strength value="required" /> <description value="ValueSet relativo agli stili di vita" /> <valueSet value="https://fhir.siss.regione.lombardia.it/ValueSet/SGDT-StiliVita" /> </binding> </element> <element id="Observation.code.coding.display"> <path value="Observation.code.coding.display" /> <short value="Descrizione della tipologia dello stile di vita" /> <definition value="Stringa alfabetica di al più 50 caratteri" /> <min value="1" /> </element> <element id="Observation.subject"> <path value="Observation.subject" /> <short value="Paziente al quale è stata diagnosticata la patologia" /> <definition value="Reference alla risorsa RLPatientCittadino contenente i dettagli anagrafici del paziente" /> <comment value="Il dato è detenuto dal SGDT" /> <min value="1" /> <type> <code value="Reference" /> <targetProfile value="https://fhir.siss.regione.lombardia.it/StructureDefinition/RLPatientCittadino" /> </type> </element> <element id="Observation.effective[x]"> <path value="Observation.effective[x]" /> <short value="Data e ora di registrazione dello stile di vita" /> <definition value="Formato: YYYY-MM-DDThh:mm:ss+zz:zz secondo lo standard FHIR" /> <comment value="Il dato è detenuto dal SGDT" /> <type> <code value="dateTime" /> </type> </element> <element id="Observation.value[x]"> <path value="Observation.value[x]" /> <short value="Codifica e descrizione dello stato relativo al corrispondende stile di vita" /> <definition value="Codifica in fase di definizione" /> <comment value="Il dato è detenuto dal SGDT" /> <min value="1" /> <type> <code value="CodeableConcept" /> </type> </element> <element id="Observation.value[x].coding"> <path value="Observation.value[x].coding" /> <short value="Codifica e descrizione dello stato relativo al corrispondende stile di vita" /> <min value="1" /> <max value="1" /> </element> <element id="Observation.value[x].coding.code"> <path value="Observation.value[x].coding.code" /> <short value="Codice dell'osservazione sullo stile di vita" /> <comment value="Il dato è detenuto dal SGDT." /> <min value="1" /> </element> <element id="Observation.value[x].coding.display"> <path value="Observation.value[x].coding.display" /> <short value="Codice dell'osservazione sullo stile di vita" /> <definition value="Stringa alfanumerica di al più 1000 caratteri" /> <comment value="Il dato è detenuto dal SGDT" /> <min value="1" /> </element> </differential> </StructureDefinition>
JSON View
{ "resourceType": "StructureDefinition", "id": "RLObservationStiliVita", "meta": { "lastUpdated": "2023-03-08T13:58:18.2997887+00:00" }, "url": "https://fhir.siss.regione.lombardia.it/StructureDefinition/RLObservationStiliVita", "name": "RLObservationStiliVita", "status": "active", "description": "Profilo volto a descrivere le osservazioni sugli stili di vita del paziente.", "keyword": [ { "system": "https://fhir.siss.regione.lombardia.it/CodeSystem/Tag", "code": "PI" } ], "fhirVersion": "4.0.1", "kind": "resource", "abstract": false, "type": "Observation", "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Observation", "derivation": "constraint", "differential": { "element": [ { "id": "Observation.id", "path": "Observation.id", "short": "UUID prodotto dal server FHIR (applicativo) che detiente la risorsa", "min": 1 }, { "id": "Observation.meta", "path": "Observation.meta", "short": "Metadati della risorsa", "min": 1 }, { "id": "Observation.meta.versionId", "path": "Observation.meta.versionId", "short": "Versione della risorsa", "min": 1 }, { "id": "Observation.meta.lastUpdated", "path": "Observation.meta.lastUpdated", "short": "Data e ora di ultimo aggiornamento della risorsa", "definition": "Formato standard FHIR: YYY-MM-DDThh:mm:ss.sss+zz:zz", "min": 1 }, { "id": "Observation.meta.profile", "path": "Observation.meta.profile", "short": "Profilo al quale la risorsa si riferisce", "min": 1, "max": "1", "fixedCanonical": "https://fhir.siss.regione.lombardia.it/StructureDefinition/RLObservationStiliVita" }, { "id": "Observation.basedOn", "path": "Observation.basedOn", "short": "Riferimento al progetto individuale nel quale è prevista l'erogazione della prestazione", "definition": "Reference al profilo RLCarePlanProgettoIndividuale contenente il progetto individuale del paziente", "comment": "Il dato è detenuto dal SGDT", "min": 1, "max": "1", "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.siss.regione.lombardia.it/StructureDefinition/RLCarePlanProgettoIndividuale" ] } ] }, { "id": "Observation.status", "path": "Observation.status", "short": "Stato della registrazione dello stile di vita", "definition": "Valore fisso su \"final\"", "fixedCode": "final" }, { "id": "Observation.category", "path": "Observation.category", "short": "Classificazione della registrazione dello stile di vita", "definition": "Valore fisso su \"social-history\" cosi come previsto dal value-set dello standard FHIR", "min": 1, "max": "1", "fixedCodeableConcept": { "text": "social-history" } }, { "id": "Observation.code", "path": "Observation.code", "short": "Codifica dello stile di vita", "comment": "Per il dettaglio esaustivo della codifica consultare la Tabella degli stili di vita contenuta nella sezione dei value-set del profilo presente nell'Implementation Guide." }, { "id": "Observation.code.coding", "path": "Observation.code.coding", "short": "Le tipologie dello stile di vita sono: fumo, alcol, sedentarietà ed eccesso ponderale", "min": 1, "max": "1" }, { "id": "Observation.code.coding.code", "path": "Observation.code.coding.code", "short": "Codice della tipologia dello stile di vita", "definition": "Codice numerico di 2 cifre", "comment": "Il dato è detenuto dal SGDT", "min": 1, "binding": { "strength": "required", "description": "ValueSet relativo agli stili di vita", "valueSet": "https://fhir.siss.regione.lombardia.it/ValueSet/SGDT-StiliVita" } }, { "id": "Observation.code.coding.display", "path": "Observation.code.coding.display", "short": "Descrizione della tipologia dello stile di vita", "definition": "Stringa alfabetica di al più 50 caratteri", "min": 1 }, { "id": "Observation.subject", "path": "Observation.subject", "short": "Paziente al quale è stata diagnosticata la patologia", "definition": "Reference alla risorsa RLPatientCittadino contenente i dettagli anagrafici del paziente", "comment": "Il dato è detenuto dal SGDT", "min": 1, "type": [ { "code": "Reference", "targetProfile": [ "https://fhir.siss.regione.lombardia.it/StructureDefinition/RLPatientCittadino" ] } ] }, { "id": "Observation.effective[x]", "path": "Observation.effective[x]", "short": "Data e ora di registrazione dello stile di vita", "definition": "Formato: YYYY-MM-DDThh:mm:ss+zz:zz secondo lo standard FHIR", "comment": "Il dato è detenuto dal SGDT", "type": [ { "code": "dateTime" } ] }, { "id": "Observation.value[x]", "path": "Observation.value[x]", "short": "Codifica e descrizione dello stato relativo al corrispondende stile di vita", "definition": "Codifica in fase di definizione", "comment": "Il dato è detenuto dal SGDT", "min": 1, "type": [ { "code": "CodeableConcept" } ] }, { "id": "Observation.value[x].coding", "path": "Observation.value[x].coding", "short": "Codifica e descrizione dello stato relativo al corrispondende stile di vita", "min": 1, "max": "1" }, { "id": "Observation.value[x].coding.code", "path": "Observation.value[x].coding.code", "short": "Codice dell'osservazione sullo stile di vita", "comment": "Il dato è detenuto dal SGDT.", "min": 1 }, { "id": "Observation.value[x].coding.display", "path": "Observation.value[x].coding.display", "short": "Codice dell'osservazione sullo stile di vita", "definition": "Stringa alfanumerica di al più 1000 caratteri", "comment": "Il dato è detenuto dal SGDT", "min": 1 } ] } }
Esempi
Al momento non ci sono esempi disponibili.Tipologie di ricerca
Attualmente non sono stati definiti criteri di ricerca.
Search parameter
Attualmente non sono definiti Search Parameters oltre quelli previsti dallo standard per la risorsa Observation.
ValueSet
Nella seguente tabella sono elencati i value set relativi al profilo RLObservationStiliVita:
Nome | Descrizione | Riferimento al dettaglio della codifica |
---|---|---|
code | Codice e descrizione dello stile di vita | La codifica è definita dal ValueSet SGDT Stili Vita |