RLLocationPLOEdificio

Descrizione

Profilo declinato a partire dalla risorsa standard FHIR Location volto a contenere le informazioni relative all'edificio di una struttura ospedaliera.

Di seguito è presentato il contenuto del profilo in diversi formati. La corrispondente definizione è consultabile al seguente link: RLLocationPLOEdificio.


Snapshot View

idΣ1..1System.StringFixed Value
versionIdΣ1..1id
lastUpdatedΣ1..1instant
sourceΣ0..1uri
profileΣ1..1canonical(StructureDefinition)Fixed Value
securityΣ0..*CodingBinding
tagΣ0..*Coding
identifierΣ1..1Identifier
statusΣ ?!0..1codeBinding
operationalStatusΣ0..1CodingBinding
nameΣ0..1string
alias0..*string
descriptionΣ0..1string
modeΣ0..1codeBinding
typeΣ0..*CodeableConceptBinding
telecomI0..*ContactPoint
address0..1Address
physicalTypeΣ0..1CodeableConceptBindingFixed Value
longitude1..1decimal
latitude1..1decimal
altitude0..1decimal
managingOrganizationΣ I1..1Reference(RLOrganizationL2)
partOfI0..1Reference(Location)
daysOfWeek0..*codeBinding
allDay0..1boolean
openingTime0..1time
closingTime0..1time
availabilityExceptions0..1string
endpointI0..*Reference(Endpoint)

Differential View

idΣ1..1System.StringFixed Value
versionIdΣ1..1id
lastUpdatedΣ1..1instant
sourceΣ0..1uri
profileΣ1..1canonical(StructureDefinition)Fixed Value
securityΣ0..*CodingBinding
tagΣ0..*Coding
identifierΣ1..1Identifier
statusΣ ?!0..1codeBinding
operationalStatusΣ0..1CodingBinding
nameΣ0..1string
alias0..*string
descriptionΣ0..1string
modeΣ0..1codeBinding
typeΣ0..*CodeableConceptBinding
telecomI0..*ContactPoint
address0..1Address
physicalTypeΣ0..1CodeableConceptBindingFixed Value
longitude1..1decimal
latitude1..1decimal
altitude0..1decimal
managingOrganizationΣ I1..1Reference(RLOrganizationL2)
partOfI0..1Reference(Location)
daysOfWeek0..*codeBinding
allDay0..1boolean
openingTime0..1time
closingTime0..1time
availabilityExceptions0..1string
endpointI0..*Reference(Endpoint)

Hybrid View

idΣ1..1System.StringFixed Value
versionIdΣ1..1id
lastUpdatedΣ1..1instant
sourceΣ0..1uri
profileΣ1..1canonical(StructureDefinition)Fixed Value
securityΣ0..*CodingBinding
tagΣ0..*Coding
identifierΣ1..1Identifier
statusΣ ?!0..1codeBinding
operationalStatusΣ0..1CodingBinding
nameΣ0..1string
alias0..*string
descriptionΣ0..1string
modeΣ0..1codeBinding
typeΣ0..*CodeableConceptBinding
telecomI0..*ContactPoint
address0..1Address
physicalTypeΣ0..1CodeableConceptBindingFixed Value
longitude1..1decimal
latitude1..1decimal
altitude0..1decimal
managingOrganizationΣ I1..1Reference(RLOrganizationL2)
partOfI0..1Reference(Location)
daysOfWeek0..*codeBinding
allDay0..1boolean
openingTime0..1time
closingTime0..1time
availabilityExceptions0..1string
endpointI0..*Reference(Endpoint)

Table View

Location..
Location.id1..
Location.meta1..
Location.meta.versionId1..
Location.meta.lastUpdated1..
Location.meta.profile1..1
Location.identifier1..1
Location.name..
Location.physicalType..
Location.managingOrganizationReference(RLOrganizationL2)1..


XML View

<StructureDefinition xmlns="http://hl7.org/fhir">
    <url value="https://fhir.siss.regione.lombardia.it/StructureDefinition/RLLocationPLOEdificio" />
    <name value="RLLocationPLOEdificio" />
    <status value="draft" />
    <description value="Profilo per descrivere le informazioni relative all&#39;edificio di una struttura ospedaliera." />
    <keyword>
        <system value="https://fhir.siss.regione.lombardia.it/CodeSystem/Tag" />
        <code value="PLO" />
    </keyword>
    <fhirVersion value="4.0.1" />
    <kind value="resource" />
    <abstract value="false" />
    <type value="Location" />
    <baseDefinition value="http://hl7.org/fhir/StructureDefinition/Location" />
    <derivation value="constraint" />
    <differential>
        <element id="Location.id">
            <path value="Location.id" />
            <min value="1" />
            <fixedString value="UUID prodotto dal server FHIR (applicativo) che detiene la risorsa. Per maggiori informazioni su chi detiene la risorsa consultare il paragrafo API-Restful nella pagina di Contesto." />
        </element>
        <element id="Location.meta">
            <path value="Location.meta" />
            <min value="1" />
        </element>
        <element id="Location.meta.versionId">
            <path value="Location.meta.versionId" />
            <short value="Versione della risorsa" />
            <min value="1" />
        </element>
        <element id="Location.meta.lastUpdated">
            <path value="Location.meta.lastUpdated" />
            <short value="Data e ora di ultimo aggiornamento della risorsa" />
            <definition value="Formato standard FHIR: YYY-MM-DDThh:mm:ss.sss+zz:zz" />
            <min value="1" />
        </element>
        <element id="Location.meta.profile">
            <path value="Location.meta.profile" />
            <short value="Profilo al quale la risorsa si riferisce" />
            <min value="1" />
            <max value="1" />
            <fixedCanonical value="https://fhir.siss.regione.lombardia.it/StructureDefinition/RLLocationPLOEdificio" />
        </element>
        <element id="Location.identifier">
            <path value="Location.identifier" />
            <short value="Identificativo edificio" />
            <definition value="Stringa composta dalle seguenti informazioni: &quot;codiceL2-Edificio&quot;" />
            <min value="1" />
            <max value="1" />
        </element>
        <element id="Location.name">
            <path value="Location.name" />
            <short value="Nome identificativo edificio" />
        </element>
        <element id="Location.physicalType">
            <path value="Location.physicalType" />
            <fixedCodeableConcept>
                <coding>
                    <system value="http://hl7.org/fhir/ValueSet/location-physical-type" />
                    <code value="bu" />
                    <display value="Building" />
                </coding>
            </fixedCodeableConcept>
            <binding>
                <strength value="required" />
            </binding>
        </element>
        <element id="Location.managingOrganization">
            <path value="Location.managingOrganization" />
            <short value="Codice L2 identificativo della struttura (codice CUDES)" />
            <definition value="Reference al profilo RLOrganizationL2" />
            <min value="1" />
            <type>
                <code value="Reference" />
                <targetProfile value="https://fhir.siss.regione.lombardia.it/StructureDefinition/RLOrganizationL2" />
            </type>
        </element>
    </differential>
</StructureDefinition>

JSON View

{
    "resourceType": "StructureDefinition",
    "url": "https://fhir.siss.regione.lombardia.it/StructureDefinition/RLLocationPLOEdificio",
    "name": "RLLocationPLOEdificio",
    "status": "draft",
    "description": "Profilo per descrivere le informazioni relative all'edificio di una struttura ospedaliera.",
    "keyword":  [
        {
            "system": "https://fhir.siss.regione.lombardia.it/CodeSystem/Tag",
            "code": "PLO"
        }
    ],
    "fhirVersion": "4.0.1",
    "kind": "resource",
    "abstract": false,
    "type": "Location",
    "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Location",
    "derivation": "constraint",
    "differential": {
        "element":  [
            {
                "id": "Location.id",
                "path": "Location.id",
                "min": 1,
                "fixedString": "UUID prodotto dal server FHIR (applicativo) che detiene la risorsa. Per maggiori informazioni su chi detiene la risorsa consultare il paragrafo API-Restful nella pagina di Contesto."
            },
            {
                "id": "Location.meta",
                "path": "Location.meta",
                "min": 1
            },
            {
                "id": "Location.meta.versionId",
                "path": "Location.meta.versionId",
                "short": "Versione della risorsa",
                "min": 1
            },
            {
                "id": "Location.meta.lastUpdated",
                "path": "Location.meta.lastUpdated",
                "short": "Data e ora di ultimo aggiornamento della risorsa",
                "definition": "Formato standard FHIR: YYY-MM-DDThh:mm:ss.sss+zz:zz",
                "min": 1
            },
            {
                "id": "Location.meta.profile",
                "path": "Location.meta.profile",
                "short": "Profilo al quale la risorsa si riferisce",
                "min": 1,
                "max": "1",
                "fixedCanonical": "https://fhir.siss.regione.lombardia.it/StructureDefinition/RLLocationPLOEdificio"
            },
            {
                "id": "Location.identifier",
                "path": "Location.identifier",
                "short": "Identificativo edificio",
                "definition": "Stringa composta dalle seguenti informazioni: \"codiceL2-Edificio\"",
                "min": 1,
                "max": "1"
            },
            {
                "id": "Location.name",
                "path": "Location.name",
                "short": "Nome identificativo edificio"
            },
            {
                "id": "Location.physicalType",
                "path": "Location.physicalType",
                "fixedCodeableConcept": {
                    "coding":  [
                        {
                            "system": "http://hl7.org/fhir/ValueSet/location-physical-type",
                            "code": "bu",
                            "display": "Building"
                        }
                    ]
                },
                "binding": {
                    "strength": "required"
                }
            },
            {
                "id": "Location.managingOrganization",
                "path": "Location.managingOrganization",
                "short": "Codice L2 identificativo della struttura (codice CUDES)",
                "definition": "Reference al profilo RLOrganizationL2",
                "min": 1,
                "type":  [
                    {
                        "code": "Reference",
                        "targetProfile":  [
                            "https://fhir.siss.regione.lombardia.it/StructureDefinition/RLOrganizationL2"
                        ]
                    }
                ]
            }
        ]
    }
}

Esempi

3

Tipologie di ricerca

Attualmente non sono stati definiti criteri di ricerca.

Search parameter

Attualmente non sono definiti Search Parameters oltre quelli previsti dallo standard per la risorsa Location.

ValueSet

Attualmente non sono definiti value set specifici per il profilo RLLocationPLOEdificio.