HdBe-VisualAcuity

CBBStatusURL
HdBe-VisualAcuitydrafthttps://fhir.healthdata.be/StructureDefinition/LogicalModel/HdBe-VisualAcuity

visual_acuity_measurement_device0..1CodeableConceptBinding
visual_acuity_type0..1CodeableConceptBinding
visual_acuity_measurement_chart0..1CodeableConceptBinding
distance_from_chart0..1Quantity
decimal_visual_aqcuity0..1Quantity
visual_acuity_date_time0..1dateTime
anatomical_location0..1HdBe AnatomicalLocation

visual_acuity0..*
visual_acuity.visual_acuity_measurement_deviceCodeableConcept0..1
visual_acuity.visual_acuity_typeCodeableConcept0..1
visual_acuity.visual_acuity_measurement_chartCodeableConcept0..1
visual_acuity.distance_from_chartQuantity0..1
visual_acuity.decimal_visual_aqcuityQuantity0..1
visual_acuity.visual_acuity_date_timedateTime0..1
visual_acuity.anatomical_locationHdBe AnatomicalLocation0..1



visual_acuity
DefinitionRoot concept of the VisualAcuity information model.This root concept contains all data elements of the VisualAcuity information model.
Cardinality0...*
Invariants
  • ele-1:All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim:n/a
visual_acuity.id
DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
Cardinality0...1
TypeSystem.String
Mappings
  • rim:n/a
visual_acuity.extension
DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension.
Cardinality0...*
TypeExtension
Aliasextensions, user content
Comments

There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.

SlicingUnordered, Open, by url(Value)
Invariants
  • ele-1:All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
  • ext-1:Must have either extensions or value[x], not both
    extension.exists() != value.exists()
Mappings
  • rim:n/a
  • rim:N/A
visual_acuity.visual_acuity_measurement_device
DefinitionThe device used measuring the visual acuity.
Cardinality0...1
TypeCodeableConcept
Binding

VisualAcuityMeasurementDevice codes

VisusMeetHulpmiddel (extensible)
Comments

Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

Invariants
  • ele-1:All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim:n/a
  • v2:CE/CNE/CWE
  • rim:CD
  • orim:fhir:CodeableConcept rdfs:subClassOf dt:CD
visual_acuity.visual_acuity_type
DefinitionType of visual acuity measurment.
Cardinality0...1
TypeCodeableConcept
Binding

VisualAcuityType codes

VisusMetingType (extensible)
Comments

Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

Invariants
  • ele-1:All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim:n/a
  • v2:CE/CNE/CWE
  • rim:CD
  • orim:fhir:CodeableConcept rdfs:subClassOf dt:CD
visual_acuity.visual_acuity_measurement_chart
DefinitionThe type of chart used for the visual acuity measurement.
Cardinality0...1
TypeCodeableConcept
Binding

VisualAcuityMeasurementChart codes

VisusMetingKaart (extensible)
Comments

Not all terminology uses fit this general pattern. In some cases, models should not use CodeableConcept and use Coding directly and provide their own structure for managing text, codings, translations and the relationship between elements and pre- and post-coordination.

Invariants
  • ele-1:All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim:n/a
  • v2:CE/CNE/CWE
  • rim:CD
  • orim:fhir:CodeableConcept rdfs:subClassOf dt:CD
visual_acuity.distance_from_chart
DefinitionDistance to the chart in meters
Cardinality0...1
TypeQuantity
Comments

The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.

Invariants
  • ele-1:All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
  • qty-3:If a code for the unit is present, the system SHALL also be present
    code.empty() or system.exists()
Mappings
  • rim:n/a
  • v2:SN (see also Range) or CQ
  • rim:PQ, IVL<PQ>, MO, CO, depending on the values
visual_acuity.decimal_visual_aqcuity
DefinitionThe measured decimal visual acuity.
Cardinality0...1
TypeQuantity
Comments

The context of use may frequently define what kind of quantity this is and therefore what kind of units can be used. The context of use may also restrict the values for the comparator.

Invariants
  • ele-1:All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
  • qty-3:If a code for the unit is present, the system SHALL also be present
    code.empty() or system.exists()
Mappings
  • rim:n/a
  • v2:SN (see also Range) or CQ
  • rim:PQ, IVL<PQ>, MO, CO, depending on the values
visual_acuity.visual_acuity_date_time
DefinitionThe date and time when the visual acuity was measured.
Cardinality0...1
TypedateTime
Invariants
  • ele-1:All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim:n/a
visual_acuity.anatomical_location
DefinitionThe laterality of the eye of which the visual acuity has been measured.
Cardinality0...1
TypeHdBe AnatomicalLocation
Invariants
  • ele-1:All FHIR elements must have a @value or children
    hasValue() or (children().count() > id.count())
Mappings
  • rim:n/a

Example instances

[CBB name]
[Concept name ] [example value]

// example of NameInformation

## Example instances

| name_information      |                   |
|----------------------|-------------------|
| first_names | Johanna Petronella Maria   
| initials | J.P.M. 
| given_name | Jo 
| name_usage | Geslachtsnaam partner gevolgd door eigen geslachtsnaam
| last_name.prefix | van
| last_name.last_name | Putten
| last_name_partner.partner_prefix | van der
| last_name_partner.partner_last_name | Giessen
| titles |

zib [zib name + version](https://zibs.nl/wiki/[zib name + version(release)]) difference

Concept Category Description
[element.path] [category of change] [Description of change]([Reference to ticket/issue/zulip chat using MarkDown link])



Terminology Bindings

PathNameStrengthURL
visual_acuity_measurement_deviceVisusMeetHulpmiddelextensiblehttps://fhir.healthdata.be/ValueSet/VisusMeetHulpmiddel
visual_acuity_typeVisusMetingTypeextensiblehttps://fhir.healthdata.be/ValueSet/VisusMetingType
visual_acuity_measurement_chartVisusMetingKaartextensiblehttps://fhir.healthdata.be/ValueSet/VisusMetingKaart