Online Consultation to Community Pharmacy - Pilot Specification

This guidance is under active development by NHS Digital and content may be added or updated on a regular basis.
Note: This is an invite-only private alpha.

Profile: ITK-MessageHeader-2

Command 'tree' could not render: Response did not arrive on time in 00:00:30 for message: Request *cli/f04fccb1@df9cdc80->S10.240.0.37:30000:0*grn/Clovis.Grains.PackageFileGrain/0+2148|https://fhir.nhs.uk/STU3/StructureDefinition/ITK-MessageHeader-2 InvokeMethodRequest Clovis.Interfaces.IPackageFileGrain:GetSnapshot #29562. Target History is: .
Command 'dict' could not render: Response did not arrive on time in 00:00:30 for message: Request *cli/f04fccb1@df9cdc80->S10.240.0.37:30000:0*grn/Clovis.Grains.PackageFileGrain/0+2148|https://fhir.nhs.uk/STU3/StructureDefinition/ITK-MessageHeader-2 InvokeMethodRequest Clovis.Interfaces.IPackageFileGrain:GetSnapshot #29566. Target History is: .

Elements required for capability

Element Use CareConnect UK Core
extension(ITKMessageHandling)
event
receiver
sender
timestamp
source
response
focus

extension(ITKMessageHandling)

Usage

Mandatory

Guidance

This item is found in the Extension-ITK-MessageHandling-2 extension within the ITK3 Message Header. More information about how to populate this element can be found in this guide using the link below.

Command 'pagelink' could not render: Page not found.


event

Usage

Mandatory

Guidance

The ITK-MessageHeader-2.event MUST contain a fixed value of ITK007C (ITK GP Connect Send Document) from the code system ITK-MessageEvent-2.

Example
<event>
   <system value="https://fhir.nhs.uk/STU3/CodeSystem/ITK-MessageEvent-2"/>
   <code value="ITK007C"/>
   <display value="ITK GP Connect Send Document"/>
</event>


receiver

Usage

Do not use (if relying on MESH for message routing)

Guidance
Note: This only applies if your organisation is using MESH for message routing. If your organisation is using FHIR, then this element must be populated. Guidance on how to populate this will be provided in a future version of this implementation guide.

This value MUST NOT be present. This is because we rely on MESH message routing to be used to route the message to the registered GP practice using a citizen's:

  • NHS Number
  • date of birth
  • surname

sender

Usage

Mandatory

Guidance

A reference MUST be provided using the CareConnect-ITK-Header-Organization-1 resource.

More information about how to populate this resource can be found in this guide using the link below.

Command 'pagelink' could not render: Page not found.


timestamp

Usage

Mandatory

Guidance

The timestamp element MUST contain the date and time of when the message was generated.

Note: A separate process such as the MESH client may be responsible for sending the message at a later date/time.

source

Usage

Mandatory

Guidance

The source element MUST contain the MESH mailbox ID of the sender.

Example
<source>
    <endpoint value="MESHGP0001" />
</source>


response

Usage

Do not use

Guidance

Not required to be populated as this use case assumes communication is linear between the sender and receiver.


focus

Usage

Mandatory

Guidance

A reference MUST be provided using the ITK-Document-Bundle-1 resource.

More information about how to populate this resource can be found in this guide using the link below.

Command 'pagelink' could not render: Page not found.


back to top