Parauga reģistrācija un labošana
Laboratorisko paraugu datu apmaiņas nodrošināšanai tiek izmantots FHIR R4B bāzes resurss Specimen
Parauga struktūra
Parauga materiāla datu iesūtīšanai izmanototais profils:
LaboratorySpecimen (Specimen) | I | Specimen | There are no (further) constraints on this element Element idSpecimen Sample for analysis DefinitionA sample to be used for analysis.
| |
id | Σ | 0..1 | id | Element idSpecimen.id Logical id of this artifact DefinitionThe logical id of the resource, as used in the URL for the resource. Once assigned, this value never changes. ©NHS: Value SHALL NOT be provided in CREATE requests. Id is being applied by the system and it is available in READ responses and it is required in UPDATE requests. The only time that a resource does not have an id is when it is being submitted to the server using a create operation. |
meta | Σ | 1..1 | MedicalMeta | Element idSpecimen.meta Metadata about a resource DefinitionThe metadata about a resource. This is content in the resource that is maintained by the infrastructure. Changes to the content might not always be associated with version changes to the resource.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.meta.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.meta.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
versionId | Σ | 0..1 | id | There are no (further) constraints on this element Element idSpecimen.meta.versionId Version specific identifier DefinitionThe version specific identifier, as it appears in the version portion of the URL. This value changes when the resource is created, updated, or deleted. ©NHS: Value SHALL NOT be provided in CREATE and UPDATE requests. VersionId is being applied by the system and it is only available in READ response. The server assigns this value, and ignores what the client specifies, except in the case that the server is imposing version integrity on updates/deletes.
|
lastUpdated | Σ | 0..1 | instant | There are no (further) constraints on this element Element idSpecimen.meta.lastUpdated When the resource version last changed DefinitionWhen the resource last changed - e.g. when the version changed. ©NHS: Value SHALL NOT be provided in CREATE and UPDATE requests. lastUpdated is being applied by the system and it is only available in READ response. This value is always populated except when the resource is first being created. The server / resource manager sets this value; what a client provides is irrelevant. This is equivalent to the HTTP Last-Modified and SHOULD have the same value on a read interaction.
|
source | Σ | 0..1 | uri | There are no (further) constraints on this element Element idSpecimen.meta.source Identifies where the resource comes from DefinitionA uri that identifies the source system of the resource. This provides a minimal amount of Provenance information that can be used to track or differentiate the source of information in the resource. The source may identify another FHIR server, document, message, database, etc. ©NHS: Value SHALL NOT be provided in CREATE and UPDATE requests. It is only available in READ response when required by business. In the provenance resource, this corresponds to Provenance.entity.what[x]. The exact use of the source (and the implied Provenance.entity.role) is left to implementer discretion. Only one nominated source is allowed; for additional provenance details, a full Provenance resource should be used. This element can be used to indicate where the current master source of a resource that has a canonical URL if the resource is no longer hosted at the canonical URL.
|
profile | Σ | 1..1 | canonical(StructureDefinition) | There are no (further) constraints on this element Element idSpecimen.meta.profile Profiles this resource claims to conform to DefinitionA list of profiles (references to StructureDefinition resources) that this resource claims to conform to. The URL is a reference to StructureDefinition.url. ©NHS: Profile SHALL always be provided. It is up to the server and/or other infrastructure of policy to determine whether/how these claims are verified and/or updated over time. The list of profile URLs is a set. canonical(StructureDefinition) Constraints
|
security | Σ | 0..0 | CodingBinding | There are no (further) constraints on this element Element idSpecimen.meta.security Security Labels applied to this resource DefinitionSecurity labels applied to this resource. These tags connect specific resources to the overall security policy and infrastructure. The security labels can be updated without changing the stated version of the resource. The list of security labels is a set. Uniqueness is based the system/code, and version and display are ignored. All Security Labels (extensible) Constraints
|
tag | Σ | 1..* | Coding | There are no (further) constraints on this element Element idSpecimen.meta.tag Tags applied to this resource DefinitionTags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource. ©NHS: Tags are required to identify who is responsible for the information in the resource, i.e. who provided/created it. The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored. Unordered, Closed, by system(Value) Binding Constraints
|
authorMedicalInstitution | Σ | 1..1 | Coding | There are no (further) constraints on this element Element idSpecimen.meta.tag:authorMedicalInstitution Tags applied to this resource DefinitionTags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource. ©NHS: Authorized Medical Institution making the request. Values SHALL be provided in CREATE and UPDATE requests of Medical Institutions. When provided SHALL be validated against JWT. The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored.
|
id | 1..1 | idFixed Value | There are no (further) constraints on this element Element idSpecimen.meta.tag:authorMedicalInstitution.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. authorMedicalInstitution
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.meta.tag:authorMedicalInstitution.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element idSpecimen.meta.tag:authorMedicalInstitution.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
urn:oid:1.3.6.1.4.1.38760.2.23
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.meta.tag:authorMedicalInstitution.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ I | 1..1 | code | There are no (further) constraints on this element Element idSpecimen.meta.tag:authorMedicalInstitution.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). ©NHS: Medical Institution code. ConceptCode from VVIS 1.3.6.1.4.1.38760.2.23 (Organization.identifier:medicalInstitutionIdentifier.value) is expected. Code SHALL be identical to "VIAuthorityCode" in JWT. Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size ©NHS: Maximum 20 symbols are expected.
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.meta.tag:authorMedicalInstitution.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. ©NHS: Medical Institution name. ConceptCode displayText from VVIS 1.3.6.1.4.1.38760.2.23 (Organization.name) is expected. DisplayText SHALL be identical to "AuthorityFullName" in JWT. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size ©NHS: Maximum 300 symbols are expected.
300
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.meta.tag:authorMedicalInstitution.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
entererMedicalPerson | Σ | 0..1 | Coding | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPerson Tags applied to this resource DefinitionTags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource. ©NHS: Authorized Medical Person making the request. Values SHALL be provided in CREATE and UPDATE requests of Medical Personal. When provided SHALL be validated against JWT. The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored.
|
id | 1..1 | idFixed Value | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPerson.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. entererMedicalPerson
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPerson.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPerson.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
urn:oid:1.3.6.1.4.1.38760.2.1
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPerson.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ I | 1..1 | code | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPerson.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). ©NHS: Medical Person code. Property id=4 from VVIS 1.3.6.1.4.1.38760.2.1 (Practitioner.identifier:HealthInspectorateIdentifier.value where system=1.3.6.1.4.1.38760.3.1.4) is expected. When provided SHALL be validated aigainst JWT VIMedicalCode. Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size ©NHS: Maximum 11 symbols are expected.
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPerson.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. ©NHS: Medical Person name. ConceptCode displayText from VVIS 1.3.6.1.4.1.38760.2.1 (Practitioner.name.text) is expected. Value SHALL be identical to displayText from VVIS 1.3.6.1.4.1.38760.2.1 (Practitioner.name.text) at the request time. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size ©NHS: Maximum 200 symbols are expected.
200
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPerson.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
entererPersonId | Σ | 0..0 | Coding | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererPersonId Tags applied to this resource DefinitionTags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource. ©NHS: Authorized Person making the request. Values SHOULD be provided in CREATE and UPDATE requests of any human actor not registered in Health Inspection. When provided SHALL be validated against JWT. The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored.
|
entererSystem | Σ | 1..1 | Coding | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererSystem Tags applied to this resource DefinitionTags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource. ©NHS: HIS, LIS or other information system making the request. Values SHALL be provided in CREATE and UPDATE requests. The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored.
|
id | 1..1 | idFixed Value | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererSystem.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. entererSystem
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererSystem.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererSystem.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://vvis.gov.lv/fhir/CodeSystem/1.3.6.1.4.1.38760.2.3
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererSystem.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ I | 1..1 | code | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererSystem.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). ©NHS: Information system code, NOT system developer code. Information system code from VVIS 1.3.6.1.4.1.38760.2.3 is expected. Code SHALL be identical to classifier code on the request dateTime. Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size ©NHS: Maximum 64 symbols are expected.
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererSystem.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. ©NHS: Information system name, NOT system developer name. Information system code displayText from VVIS 1.3.6.1.4.1.38760.2.3 is expected. DisplayText SHALL be identical to classifier code displayText on the request dateTime. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size ©NHS: Maximum 300 symbols are expected.
300
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererSystem.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
entererMedicalPersonRole | Σ | 0..1 | Coding | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPersonRole Tags applied to this resource DefinitionTags applied to this resource. Tags are intended to be used to identify and relate resources to process and workflow, and applications are not required to consider the tags when interpreting the meaning of a resource. ©NHS: Authorized Medical Person Role making the request. Values SHALL be provided in CREATE and UPDATE requests of Medical Institutions when Medical Person Role is used for authorization. When provided SHALL be validated against JWT. The tags can be updated without changing the stated version of the resource. The list of tags is a set. Uniqueness is based the system/code, and version and display are ignored.
|
id | 1..1 | idFixed Value | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPersonRole.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. entererMedicalPersonRole
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPersonRole.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPersonRole.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
urn:oid:1.3.6.1.4.1.38760.2.37
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPersonRole.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ I | 1..1 | code | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPersonRole.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). ©NHS: Medical Person Role code. Code from VVIS 1.3.6.1.4.1.38760.2.37 (PractitionerRole.identifier.value) is expected. Code SHALL be identical to JWT sub: "...-1.3.6.1.4.1.38760.2.37:PractitionerRoleCode" when medical person's workplace is used for authorization. Need to refer to a particular code in the system.
|
display | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPersonRole.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system.
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.meta.tag:entererMedicalPersonRole.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
implicitRules | Σ ?! | 0..0 | uri | There are no (further) constraints on this element Element idSpecimen.implicitRules A set of rules under which this content was created DefinitionA reference to a set of rules that were followed when the resource was constructed, and which must be understood when processing the content. Often, this is a reference to an implementation guide that defines the special rules along with other profiles etc. Asserting this rule set restricts the content to be only understood by a limited set of trading partners. This inherently limits the usefulness of the data in the long term. However, the existing health eco-system is highly fractured, and not yet ready to define, collect, and exchange data in a generally computable sense. Wherever possible, implementers and/or specification writers should avoid using this element. Often, when used, the URL is a reference to an implementation guide that defines these special rules as part of it's narrative along with other profiles, value sets, etc.
|
language | 0..0 | codeBinding | There are no (further) constraints on this element Element idSpecimen.language Language of the resource content DefinitionThe base language in which the resource is written. Language is provided to support indexing and accessibility (typically, services such as text to speech use the language tag). The html language tag in the narrative applies to the narrative. The language tag on the resource may be used to specify the language of other presentations generated from the data in the resource. Not all the content has to be in the base language. The Resource.language should not be assumed to apply to the narrative automatically. If a language is specified, it should it also be specified on the div element in the html (see rules in HTML5 for information about the relationship between xml:lang and the html lang attribute). IETF language tag
| |
text | 0..0 | Narrative | There are no (further) constraints on this element Element idSpecimen.text Text summary of the resource, for human interpretation Alternate namesnarrative, html, xhtml, display DefinitionA human-readable narrative that contains a summary of the resource and can be used to represent the content of the resource to a human. The narrative need not encode all the structured data, but is required to contain sufficient detail to make it "clinically safe" for a human to just read the narrative. Resource definitions may define what content should be represented in the narrative to ensure clinical safety. Contained resources do not have narrative. Resources that are not contained SHOULD have a narrative. In some cases, a resource may only have text with little or no additional discrete data (as long as all minOccurs=1 elements are satisfied). This may be necessary for data from legacy systems where information is captured as a "text blob" or where text is additionally entered raw or narrated and encoded information is added later.
| |
contained | I | 0..0 | Resource | There are no (further) constraints on this element Element idSpecimen.contained Contained, inline Resources Alternate namesinline resources, anonymous resources, contained resources DefinitionThese resources do not have an independent existence apart from the resource that contains them - they cannot be identified independently, and nor can they have their own independent transaction scope. This should never be done when the content can be identified properly, as once identification is lost, it is extremely difficult (and context dependent) to restore it again. Contained resources may have profiles and tags In their meta elements, but SHALL NOT have security labels.
|
extension | I | 1..* | Extension | Element idSpecimen.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Constraints
|
typeOfSpieces | I | 1..1 | Extension(CodeableConcept) | Element idSpecimen.extension:typeOfSpieces Optional Extensions Element Alternate namesextensions, user content DefinitionOptional Extension Element - found in all resources. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. https://lab.vvis.gov.lv/fhir/StructureDefinition/Extension/TypeOfSpieces-v1 Constraints
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
url | 1..1 | uriFixed Value | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.url identifies the meaning of the extension DefinitionSource of the definition for the extension code - a logical name or a URL. The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension. https://lab.vvis.gov.lv/fhir/StructureDefinition/Extension/TypeOfSpieces-v1
| |
value[x] | 1..1 | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x] Value of extension DefinitionValue of extension - must be one of a constrained set of the data types (see Extensibility for a list).
| ||
valueCodeableConcept | CodeableConcept | There are no (further) constraints on this element Data type | ||
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
coding | Σ | 1..1 | Coding | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].coding.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].coding.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://vvis.gov.lv/fhir/ValueSet/1.3.6.1.4.1.38760.2.810
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].coding.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system.
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].coding.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system.
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.extension:typeOfSpieces.value[x].text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
morphology | I | 0..1 | Extension(CodeableConcept) | Element idSpecimen.extension:morphology Optional Extensions Element Alternate namesextensions, user content DefinitionOptional Extension Element - found in all resources. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. https://lab.vvis.gov.lv/fhir/StructureDefinition/Extension/Morphology-v1 Constraints
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.extension:morphology.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.extension:morphology.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
url | 1..1 | uriFixed Value | There are no (further) constraints on this element Element idSpecimen.extension:morphology.url identifies the meaning of the extension DefinitionSource of the definition for the extension code - a logical name or a URL. The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension. https://lab.vvis.gov.lv/fhir/StructureDefinition/Extension/Morphology-v1
| |
value[x] | 1..1 | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x] Value of extension DefinitionValue of extension - must be one of a constrained set of the data types (see Extensibility for a list).
| ||
valueCodeableConcept | CodeableConcept | There are no (further) constraints on this element Data type | ||
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
coding | Σ | 1..1 | Coding | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. ©NHS: Morphological abnormality code from SNOMED GPS, if precise code not availbale a more general one. If also not available report to NHS immediately. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].coding.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].coding.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ | 1..1 | uriFixed Value | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://vvis.gov.lv/fhir/ValueSet/1.3.6.1.4.1.38760.2.813
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].coding.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].coding.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element idSpecimen.extension:morphology.value[x].text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. ©NHS: Morphological abnormality detailed description to allow correct result interpretation by any doctor studing the Laboratory report. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
statusReason | I | 0..1 | Extension(CodeableConcept) | Element idSpecimen.extension:statusReason Optional Extensions Element Alternate namesextensions, user content DefinitionOptional Extension Element - found in all resources. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. https://lab.vvis.gov.lv/fhir/StructureDefinition/Extention/StatusReason-v1 Constraints
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
url | 1..1 | uriFixed Value | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.url identifies the meaning of the extension DefinitionSource of the definition for the extension code - a logical name or a URL. The definition may point directly to a computable or human-readable definition of the extensibility codes, or it may be a logical URI as declared in some other specification. The definition SHALL be a URI for the Structure Definition defining the extension. https://lab.vvis.gov.lv/fhir/StructureDefinition/Extention/StatusReason-v1
| |
value[x] | 1..1 | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x] Value of extension DefinitionValue of extension - must be one of a constrained set of the data types (see Extensibility for a list).
| ||
valueCodeableConcept | CodeableConcept | There are no (further) constraints on this element Data type | ||
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
coding | Σ | 0..1 | Coding | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. ©NHS: Classified reason for status of the resource. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].coding.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].coding.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ I | 1..1 | uriFixed Value | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://vvis.gov.lv/fhir/ValueSet/1.3.6.1.4.1.38760.2.822
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ I | 1..1 | code | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].coding.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system. Note that FHIR strings SHALL NOT exceed 1MB in size ©NHS: Maximum 50 symbols are expected.
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].coding.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system. Note that FHIR strings SHALL NOT exceed 1MB in size ©NHS: Maximum 400 symbols are expected.
400
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element idSpecimen.extension:statusReason.value[x].text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. ©NHS: Non-classified reason for status of the resource. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings. ©NHS: Maximum 500 symbols are expected.
500
|
modifierExtension | ?! I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.modifierExtension Extensions that cannot be ignored Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource and that modifies the understanding of the element that contains it and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer is allowed to define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
identifier | Σ | 0..1 | Identifier | Element idSpecimen.identifier External Identifier DefinitionId for specimen. Id assigned by the specimen collector. ©NHS: Specimen Id assigned by the collector. If not available in LIS, SHALL NOT be provided.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.identifier.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.identifier.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
use | Σ ?! | 0..0 | codeBinding | There are no (further) constraints on this element Element idSpecimen.identifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary.
|
type | Σ | 0..0 | CodeableConceptBinding | There are no (further) constraints on this element Element idSpecimen.identifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. Identifier Type Codes (extensible) Constraints
|
system | Σ | 0..0 | uri | There are no (further) constraints on this element Element idSpecimen.identifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.identifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ | 0..0 | Period | There are no (further) constraints on this element Element idSpecimen.identifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use.
|
assigner | Σ I | 1..1 | Reference(Organization) | Element idSpecimen.identifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.identifier.assigner.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.identifier.assigner.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
reference | Σ I | 0..1 | string | Element idSpecimen.identifier.assigner.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. ©NHS: Local medical institution refence expected if specimen was collected in medical institution. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 1..1 | uriBindingFixed Value | Element idSpecimen.identifier.assigner.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified.
Organization
|
identifier | Σ | 0..0 | Identifier | There are no (further) constraints on this element Element idSpecimen.identifier.assigner.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
display | Σ | 0..1 | string | Element idSpecimen.identifier.assigner.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. ©NHS: Foreign medical institution name and id is expected if specimen was collected in medical institution abroad. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
accessionIdentifier | Σ | 1..1 | Identifier | Element idSpecimen.accessionIdentifier Identifier assigned by the lab DefinitionThe identifier assigned by the lab when accessioning specimen(s). This is not necessarily the same as the specimen identifier, depending on local lab procedures. ©NHS: SHALL always be provided because specimen data is expected only from the laboratory running tests on the specimen. If tests were run in a laboratory abroad if known foreign laboratory id is expected, if not - id assigned by the local lab. In best scenario specimen id should correspond to the one in the pdf report.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.accessionIdentifier.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.accessionIdentifier.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
use | Σ ?! | 0..0 | codeBinding | There are no (further) constraints on this element Element idSpecimen.accessionIdentifier.use usual | official | temp | secondary | old (If known) DefinitionThe purpose of this identifier. Allows the appropriate identifier for a particular context of use to be selected from among a set of identifiers. Applications can assume that an identifier is permanent unless it explicitly says that it is temporary.
|
type | Σ | 0..0 | CodeableConceptBinding | There are no (further) constraints on this element Element idSpecimen.accessionIdentifier.type Description of identifier DefinitionA coded type for the identifier that can be used to determine which identifier to use for a specific purpose. Allows users to make use of identifiers when the identifier system is not known. This element deals only with general categories of identifiers. It SHOULD not be used for codes that correspond 1..1 with the Identifier.system. Some identifiers may fall into multiple categories due to common usage. Where the system is known, a type is unnecessary because the type is always part of the system definition. However systems often need to handle identifiers where the system is not known. There is not a 1:1 relationship between type and system, since many different systems have the same type. Identifier Type Codes (extensible) Constraints
|
system | Σ | 0..0 | uri | There are no (further) constraints on this element Element idSpecimen.accessionIdentifier.system The namespace for the identifier value DefinitionEstablishes the namespace for the value - that is, a URL that describes a set values that are unique. There are many sets of identifiers. To perform matching of two identifiers, we need to know what set we're dealing with. The system identifies a particular set of unique identifiers. Identifier.system is always case sensitive.
General http://www.acme.com/identifiers/patient Mappings
|
value | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.accessionIdentifier.value The value that is unique DefinitionThe portion of the identifier typically relevant to the user and which is unique within the context of the system. If the value is a full URI, then the system SHALL be urn:ietf:rfc:3986. The value's primary purpose is computational mapping. As a result, it may be normalized for comparison purposes (e.g. removing non-significant whitespace, dashes, etc.) A value formatted for human display can be conveyed using the Rendered Value extension. Identifier.value is to be treated as case sensitive unless knowledge of the Identifier.system allows the processer to be confident that non-case-sensitive processing is safe.
General 123456 Mappings
|
period | Σ | 0..0 | Period | There are no (further) constraints on this element Element idSpecimen.accessionIdentifier.period Time period when id is/was valid for use DefinitionTime period during which identifier is/was valid for use.
|
assigner | Σ I | 1..1 | Reference(Organization) | Element idSpecimen.accessionIdentifier.assigner Organization that issued id (may be just text) DefinitionOrganization that issued/manages the identifier. The Identifier.assigner may omit the .reference element and only contain a .display element reflecting the name or other textual information about the assigning organization.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.accessionIdentifier.assigner.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.accessionIdentifier.assigner.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
reference | Σ I | 0..1 | string | Element idSpecimen.accessionIdentifier.assigner.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. ©NHS: Laboratory reference SHALL always be provided when test on specimen was run in local laboratory. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 1..1 | uriBindingFixed Value | Element idSpecimen.accessionIdentifier.assigner.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified.
Organization
|
identifier | Σ | 0..0 | Identifier | There are no (further) constraints on this element Element idSpecimen.accessionIdentifier.assigner.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
display | Σ | 0..1 | string | Element idSpecimen.accessionIdentifier.assigner.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. Organization name is expected. ©NHS: Foreign laboratory name and id SHOULD be provided when tests were provided by a laboratory abroad. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
status | Σ ?! | 1..1 | codeBinding | There are no (further) constraints on this element Element idSpecimen.status available | unavailable | unsatisfactory | entered-in-error DefinitionThe availability of the specimen. This element is labeled as a modifier because the status contains codes that mark the resource as not currently valid. Codes providing the status/availability of a specimen.
|
type | Σ | 1..1 | CodeableConcept | There are no (further) constraints on this element Element idSpecimen.type Kind of material that forms the specimen DefinitionThe kind of material that forms the specimen. The type can change the way that a specimen is handled and drives what kind of analyses can properly be performed on the specimen. It is frequently used in diagnostic work flow decision making systems. The type of the specimen.
|
id | 0..1 | id | There are no (further) constraints on this element Element idSpecimen.type.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.type.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
coding | Σ | 1..1 | Coding | There are no (further) constraints on this element Element idSpecimen.type.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
id | 0..1 | id | There are no (further) constraints on this element Element idSpecimen.type.coding.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.type.coding.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ | 1..1 | uriFixed Value | Element idSpecimen.type.coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://vvis.gov.lv/fhir/ValueSet/1.3.6.1.4.1.38760.2.809
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.type.coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | Element idSpecimen.type.coding.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). ©NHS: Type of specimen material is expected. If no precise specimen code found a more general one is expected. Precise specimen description (at least at the level of detail included in the report but better sufficient for all parties involved to interpret the results) is expected in Specimen.type.text. Need to refer to a particular code in the system.
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.type.coding.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system.
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.type.coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | Element idSpecimen.type.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. ©NHS: Precise specimen description (at least at the level of detail included in the report but better sufficient for all parties involved to interpret the results) is expected. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
subject | Σ | 1..1 | Reference(Patient | Group | Device | Substance | Location) | There are no (further) constraints on this element Element idSpecimen.subject Where the specimen came from. This may be from patient(s), from a location (e.g., the source of an environmental sample), or a sampling of a substance or a device DefinitionWhere the specimen came from. This may be from patient(s), from a location (e.g., the source of an environmental sample), or a sampling of a substance or a device. Must know the subject context. Reference(Patient | Group | Device | Substance | Location) Constraints
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.subject.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.subject.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
reference | Σ I | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.subject.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 1..1 | uriBindingFixed Value | Element idSpecimen.subject.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified.
Patient
|
identifier | Σ | 0..0 | Identifier | There are no (further) constraints on this element Element idSpecimen.subject.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
display | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.subject.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
receivedTime | Σ | 1..1 | dateTime | Element idSpecimen.receivedTime The time when specimen was received for processing DefinitionTime when specimen was received for processing or testing. ©NHS: Datetime expected.
|
parent | 0..0 | Reference(Specimen) | There are no (further) constraints on this element Element idSpecimen.parent Specimen from which this specimen originated DefinitionReference to the parent (source) specimen which is used when the specimen was either derived from or a component of another specimen. The parent specimen could be the source from which the current specimen is derived by some processing step (e.g. an aliquot or isolate or extracted nucleic acids from clinical samples) or one of many specimens that were combined to create a pooled sample.
| |
request | 1..* | Reference(LaboratoryServiceRequest | LaboratoryReferral | LaboratoryReferral) | Element idSpecimen.request Why the specimen was collected DefinitionDetails concerning a service request that required a specimen to be collected. The request may be explicit or implied such with a ServiceRequest that requires a blood draw. Reference(LaboratoryServiceRequest | LaboratoryReferral | LaboratoryReferral) Constraints
| |
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.request.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.request.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
reference | Σ I | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.request.reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 1..1 | uriBindingFixed Value | Element idSpecimen.request.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified.
ServiceRequest
|
identifier | Σ | 0..0 | Identifier | There are no (further) constraints on this element Element idSpecimen.request.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
display | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.request.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
collection | 1..1 | BackboneElement | There are no (further) constraints on this element Element idSpecimen.collection Collection details DefinitionDetails concerning the specimen collection.
| |
id | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.collection.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.collection.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
modifierExtension | Σ ?! I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.collection.modifierExtension Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
collector | Σ I | 1..1 | Reference(Practitioner | PractitionerRole) | Element idSpecimen.collection.collector Who collected the specimen DefinitionPerson who collected the specimen. : Reference(Practitioner | PractitionerRole) Constraints
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.collection.collector.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.collection.collector.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
reference | Σ I | 0..1 | string | Element idSpecimen.collection.collector.reference Literal reference, Relative, internal or absolute URL Definition©NHS: When collected in local laboratory or local medical institution PractitionerRole SHALL be referenced when known. When unknow, Practitioner SHALL be referenced. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 0..1 | uriBinding | Element idSpecimen.collection.collector.type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). ©NHS: PractitionerRole or Practitioner according to reference provided. This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified.
|
identifier | Σ | 0..0 | Identifier | There are no (further) constraints on this element Element idSpecimen.collection.collector.identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
display | Σ | 0..1 | string | Element idSpecimen.collection.collector.display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. ©NHS: When collected in foreign laboratory or foreign medical institution collector's name, id and collector's institution name and id are expected in format acceptable to place in laboratory report. When collected in local medical institution but practitioner role and even practitioner is not known at least organization name SHALL be provided. When collected by patient or patient's related person Pacients pats or Pacienta pārstāvis or the value as in report pdf is expected. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
collected[x] | Σ | 0..1 | Element idSpecimen.collection.collected[x] Collection time DefinitionTime when specimen was collected from subject - the physiologically relevant time. Unordered, Open, by $this(Type) Constraints
| |
collectedDateTime | Σ I | 0..1 | dateTime | Element idSpecimen.collection.collected[x]:collectedDateTime Collection time DefinitionTime when specimen was collected from subject - the physiologically relevant time.
|
id | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.collection.collected[x]:collectedDateTime.id xml:id (or equivalent in JSON) Definitionunique id for the element within a resource (for internal references) | |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.collection.collected[x]:collectedDateTime.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the resource. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
value | 0..1 | System.DateTime | Element idSpecimen.collection.collected[x]:collectedDateTime.value Primitive value for dateTime DefinitionPrimitive value for dateTime ©NHS: Datetime expected. System.DateTime | |
collectedPeriod | Σ | 0..1 | Period | Element idSpecimen.collection.collected[x]:collectedPeriod Collection time DefinitionTime when specimen was collected from subject - the physiologically relevant time.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.collection.collected[x]:collectedPeriod.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.collection.collected[x]:collectedPeriod.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
start | Σ I | 1..1 | dateTime | Element idSpecimen.collection.collected[x]:collectedPeriod.start Starting time with inclusive boundary DefinitionThe start of the period. The boundary is inclusive. ©NHS: Datetime expected. If the low element is missing, the meaning is that the low boundary is not known.
|
end | Σ I | 1..1 | dateTime | Element idSpecimen.collection.collected[x]:collectedPeriod.end End time with inclusive boundary, if not ongoing DefinitionThe end of the period. If the end of the period is missing, it means no end was known or planned at the time the instance was created. The start may be in the past, and the end date in the future, which means that period is expected/planned to end at that time. ©NHS: Datetime expected. The high value includes any matching date/time. i.e. 2012-02-03T10:00:00 is in a period that has an end value of 2012-02-03. If the end of the period is missing, it means that the period is ongoing
|
duration | Σ | 0..1 | Duration | Element idSpecimen.collection.duration How long it took to collect specimen DefinitionThe span of time over which the collection of a specimen occurred. ©NHS: Expected when required by business (for 24h urine for example).
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.collection.duration.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.collection.duration.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
value | Σ | 1..1 | decimal | There are no (further) constraints on this element Element idSpecimen.collection.duration.value Numerical value (with implicit precision) DefinitionThe value of the measured amount. The value includes an implicit precision in the presentation of the value. Precision is handled implicitly in almost all cases of measurement. The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).
|
comparator | Σ ?! | 0..1 | codeBinding | There are no (further) constraints on this element Element idSpecimen.collection.duration.comparator < | <= | >= | > - how to understand the value DefinitionHow the value should be understood and represented - whether the actual value is greater or less than the stated value due to measurement issues; e.g. if the comparator is "<" , then the real value is < stated value. Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology. If there is no comparator, then there is no modification of the value
|
unit | Σ | 1..1 | string | Element idSpecimen.collection.duration.unit Unit representation DefinitionA human-readable form of the unit. ©NHS: Duration unit to include in laboratory report specimen description section. There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.
|
system | Σ I | 1..1 | uri | There are no (further) constraints on this element Element idSpecimen.collection.duration.system System that defines coded unit form DefinitionThe identification of the system that provides the coded form of the unit. Need to know the system that defines the coded form of the unit.
|
code | Σ | 1..1 | code | Element idSpecimen.collection.duration.code Coded form of the unit DefinitionUCUM time codes SHALL be used. Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest. The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.
|
quantity | 0..1 | SimpleQuantity | Element idSpecimen.collection.quantity The quantity of specimen collected DefinitionThe quantity of specimen collected; for instance the volume of a blood sample, or the physical measurement of an anatomic pathology sample. ©NHS: Expected when required by business (for 24h urine for example).
| |
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.collection.quantity.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.collection.quantity.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
value | Σ | 1..1 | decimal | There are no (further) constraints on this element Element idSpecimen.collection.quantity.value Numerical value (with implicit precision) DefinitionThe value of the measured amount. The value includes an implicit precision in the presentation of the value. Precision is handled implicitly in almost all cases of measurement. The implicit precision in the value should always be honored. Monetary values have their own rules for handling precision (refer to standard accounting text books).
|
comparator | Σ ?! | 0..0 | codeBinding | There are no (further) constraints on this element Element idSpecimen.collection.quantity.comparator < | <= | >= | > - how to understand the value DefinitionNot allowed to be used in this context Need a framework for handling measures where the value is <5ug/L or >400mg/L due to the limitations of measuring methodology. If there is no comparator, then there is no modification of the value
|
unit | Σ | 1..1 | string | Element idSpecimen.collection.quantity.unit Unit representation DefinitionA human-readable form of the unit. ©NHS: Quantity unit to include in laboratory report specimen description section. There are many representations for units of measure and in many contexts, particular representations are fixed and required. I.e. mcg for micrograms.
|
system | Σ I | 1..1 | uriFixed Value | Element idSpecimen.collection.quantity.system System that defines coded unit form DefinitionThe identification of the system that provides the coded form of the unit. Need to know the system that defines the coded form of the unit.
https://vvis.gov.lv/fhir/ValueSet/1.3.6.1.4.1.38760.2.803
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element idSpecimen.collection.quantity.code Coded form of the unit DefinitionA computer processable form of the unit in some unit representation system. Need a computable form of the unit that is fixed across all forms. UCUM provides this for quantities, but SNOMED CT provides many units of interest. The preferred system is UCUM, but SNOMED CT can also be used (for customary units) or ISO 4217 for currency. The context of use may additionally require a code from a particular system.
|
method | 0..1 | CodeableConcept | Element idSpecimen.collection.method Technique used to perform collection DefinitionA coded value specifying the technique that is used to perform the procedure. ©NHS: Expected when required by business. The technique that is used to perform the procedure.
| |
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.collection.method.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.collection.method.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
coding | Σ | 1..1 | Coding | There are no (further) constraints on this element Element idSpecimen.collection.method.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.collection.method.coding.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.collection.method.coding.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ | 1..1 | uriFixed Value | Element idSpecimen.collection.method.coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://vvis.gov.lv/fhir/ValueSet/1.3.6.1.4.1.38760.2.811
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.collection.method.coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | Element idSpecimen.collection.method.coding.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). ©NHS: Codes advised by HL7: 129316008 Aspiration - action 129314006 Biopsy - action 129300006 Puncture - action 129304002 Excision - action 129323009 Scraping - action 73416001 Urine specimen collection, clean catch 225113003 Timed urine collection 70777001 Urine specimen collection, catheterized 386089008 Collection of coughed sputum 278450005 Finger-prick sampling Need to refer to a particular code in the system.
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.collection.method.coding.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system.
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.collection.method.coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | Element idSpecimen.collection.method.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. ©NHS: Expected detailed description of collection method when coded value is not enough for result interpretation. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
bodySite | 0..1 | CodeableConcept | There are no (further) constraints on this element Element idSpecimen.collection.bodySite Anatomical collection site DefinitionAnatomical location from which the specimen was collected (if subject is a patient). This is the target site. This element is not used for environmental specimens. If the use case requires BodySite to be handled as a separate resource instead of an inline coded element (e.g. to identify and track separately) then use the standard extension bodySite. SNOMED CT Body site concepts
| |
fastingStatus[x] | Σ | 0..1 | Binding | There are no (further) constraints on this element Element idSpecimen.collection.fastingStatus[x] Whether or how long patient abstained from food and/or drink DefinitionAbstinence or reduction from some or all food, drink, or both, for a period of time prior to sample collection. Many diagnostic tests require fasting to facilitate accurate interpretation. Representing fasting status using this element is preferred to representing it with an observation using a 'pre-coordinated code' such as LOINC 2005-7 (Calcium [Moles/time] in 2 hour Urine --12 hours fasting), or using a component observation Codes describing the fasting status of the patient.
|
fastingStatusCodeableConcept | CodeableConcept | Data type | ||
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.collection.fastingStatus[x].id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.collection.fastingStatus[x].extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
coding | Σ | 0..0 | Coding | There are no (further) constraints on this element Element idSpecimen.collection.fastingStatus[x].coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
text | Σ | 0..1 | string | Element idSpecimen.collection.fastingStatus[x].text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. ©NHS: Expected when required by business, especially when effecting the quality of test results. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
processing | 0..* | BackboneElement | Element idSpecimen.processing Processing and processing step details DefinitionDetails concerning processing and processing steps for the specimen. ©NHS: Expected when required by business.
| |
id | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.processing.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.processing.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
modifierExtension | Σ ?! I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.processing.modifierExtension Extensions that cannot be ignored even if unrecognized Alternate namesextensions, user content, modifiers DefinitionMay be used to represent additional information that is not part of the basic definition of the element and that modifies the understanding of the element in which it is contained and/or the understanding of the containing element's descendants. Usually modifier elements provide negation or qualification. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. Applications processing a resource are required to check for modifier extensions. Modifier extensions SHALL NOT change the meaning of any elements on Resource or DomainResource (including cannot change the meaning of modifierExtension itself). Modifier extensions allow for extensions that cannot be safely ignored to be clearly distinguished from the vast majority of extensions which can be safely ignored. This promotes interoperability by eliminating the need for implementers to prohibit the presence of extensions. For further information, see the definition of modifier extensions. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone.
|
description | 0..1 | string | There are no (further) constraints on this element Element idSpecimen.processing.description Textual description of procedure DefinitionTextual description of procedure.
| |
procedure | 1..1 | CodeableConcept | There are no (further) constraints on this element Element idSpecimen.processing.procedure Indicates the treatment step applied to the specimen DefinitionA coded value specifying the procedure used to process the specimen. Type indicating the technique used to process the specimen.
| |
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.processing.procedure.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.processing.procedure.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
coding | Σ | 1..1 | Coding | There are no (further) constraints on this element Element idSpecimen.processing.procedure.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.processing.procedure.coding.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.processing.procedure.coding.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ | 1..1 | uriFixed Value | Element idSpecimen.processing.procedure.coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://vvis.gov.lv/fhir/ValueSet/1.3.6.1.4.1.38760.2.811
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.processing.procedure.coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element idSpecimen.processing.procedure.coding.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system.
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.processing.procedure.coding.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system.
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.processing.procedure.coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.processing.procedure.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
additive | 0..0 | Reference(Substance) | There are no (further) constraints on this element Element idSpecimen.processing.additive Material used in the processing step DefinitionMaterial used in the processing step.
| |
time[x] | 0..0 | There are no (further) constraints on this element Element idSpecimen.processing.time[x] Date and time of specimen processing DefinitionA record of the time or period when the specimen processing occurred. For example the time of sample fixation or the period of time the sample was in formalin.
| ||
container | 0..0 | BackboneElement | There are no (further) constraints on this element Element idSpecimen.container Direct container of specimen (tube/slide, etc.) DefinitionThe container holding the specimen. The recursive nature of containers; i.e. blood in tube in tray in rack is not addressed here.
| |
condition | Σ | 0..* | CodeableConceptBinding | There are no (further) constraints on this element Element idSpecimen.condition State of the specimen DefinitionA mode or state of being that describes the nature of the specimen. The specimen condition can be used to assess its quality or appropriateness for a specific test. Specimen condition is an observation made about the specimen. It's a point-in-time assessment. It can be used to assess its quality or appropriateness for a specific test. Codes describing the state of the specimen.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.condition.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.condition.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
coding | Σ | 1..1 | Coding | There are no (further) constraints on this element Element idSpecimen.condition.coding Code defined by a terminology system DefinitionA reference to a code defined by a terminology system. Allows for alternative encodings within a code system, and translations to other code systems. Codes may be defined very casually in enumerations, or code lists, up to very formal definitions such as SNOMED CT - see the HL7 v3 Core Principles for more information. Ordering of codings is undefined and SHALL NOT be used to infer meaning. Generally, at most only one of the coding values will be labeled as UserSelected = true.
|
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.condition.coding.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.condition.coding.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
system | Σ | 1..1 | uriFixed Value | Element idSpecimen.condition.coding.system Identity of the terminology system DefinitionThe identification of the code system that defines the meaning of the symbol in the code. Need to be unambiguous about the source of the definition of the symbol. The URI may be an OID (urn:oid:...) or a UUID (urn:uuid:...). OIDs and UUIDs SHALL be references to the HL7 OID registry. Otherwise, the URI should come from HL7's list of FHIR defined special URIs or it should reference to some definition that establishes the system clearly and unambiguously.
https://vvis.gov.lv/fhir/ValueSet/1.3.6.1.4.1.38760.2.812
|
version | Σ | 0..0 | string | There are no (further) constraints on this element Element idSpecimen.condition.coding.version Version of the system - if relevant DefinitionThe version of the code system which was used when choosing this code. Note that a well-maintained code system does not need the version reported, because the meaning of codes is consistent across versions. However this cannot consistently be assured, and when the meaning is not guaranteed to be consistent, the version SHOULD be exchanged. Where the terminology does not clearly define what string should be used to identify code system versions, the recommendation is to use the date (expressed in FHIR date format) on which that version was officially published as the version date.
|
code | Σ | 1..1 | code | There are no (further) constraints on this element Element idSpecimen.condition.coding.code Symbol in syntax defined by the system DefinitionA symbol in syntax defined by the system. The symbol may be a predefined code or an expression in a syntax defined by the coding system (e.g. post-coordination). Need to refer to a particular code in the system.
|
display | Σ | 1..1 | string | There are no (further) constraints on this element Element idSpecimen.condition.coding.display Representation defined by the system DefinitionA representation of the meaning of the code in the system, following the rules of the system. Need to be able to carry a human-readable meaning of the code for readers that do not know the system.
|
userSelected | Σ | 0..0 | boolean | There are no (further) constraints on this element Element idSpecimen.condition.coding.userSelected If this coding was chosen directly by the user DefinitionIndicates that this coding was chosen by a user directly - e.g. off a pick list of available items (codes or displays). This has been identified as a clinical safety criterium - that this exact system/code pair was chosen explicitly, rather than inferred by the system based on some rules or language processing. Amongst a set of alternatives, a directly chosen code is the most appropriate starting point for new translations. There is some ambiguity about what exactly 'directly chosen' implies, and trading partner agreement may be needed to clarify the use of this element and its consequences more completely.
|
text | Σ | 0..1 | string | There are no (further) constraints on this element Element idSpecimen.condition.text Plain text representation of the concept DefinitionA human language representation of the concept as seen/selected/uttered by the user who entered the data and/or which represents the intended meaning of the user. The codes from the terminologies do not always capture the correct meaning with all the nuances of the human using them, or sometimes there is no appropriate code at all. In these cases, the text is used to capture the full meaning of the source. Very often the text is the same as a displayName of one of the codings.
|
note | 0..* | Annotation | Element idSpecimen.note Comments DefinitionTo communicate any details or issues about the specimen or during the specimen collection. (for example: broken vial, sent with patient, frozen). Unordered, Closed, by id(Value) Constraints
| |
collectorInformation | 0..1 | Annotation | There are no (further) constraints on this element Element idSpecimen.note:collectorInformation Comments DefinitionTo communicate any details or issues about the specimen or during the specimen collection. (for example: broken vial, sent with patient, frozen).
| |
id | 1..1 | idFixed Value | Element idSpecimen.note:collectorInformation.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. collectorInformation
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.note:collectorInformation.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
author[x] | Σ | 0..0 | There are no (further) constraints on this element Element idSpecimen.note:collectorInformation.author[x] Individual responsible for the annotation DefinitionThe individual responsible for making the annotation. Organization is used when there's no need for specific attribution as to who made the comment.
| |
time | Σ | 0..0 | dateTime | There are no (further) constraints on this element Element idSpecimen.note:collectorInformation.time When the annotation was made DefinitionIndicates when this particular annotation was made.
|
text | Σ | 1..1 | markdown | There are no (further) constraints on this element Element idSpecimen.note:collectorInformation.text The annotation - text content (as markdown) DefinitionThe text of the annotation in markdown format.
|
laboratoryInformation | 0..* | Annotation | There are no (further) constraints on this element Element idSpecimen.note:laboratoryInformation Comments DefinitionTo communicate any details or issues about the specimen or during the specimen collection. (for example: broken vial, sent with patient, frozen).
| |
id | 1..1 | idFixed Value | Element idSpecimen.note:laboratoryInformation.id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces. laboratoryInformation
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.note:laboratoryInformation.extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
author[x] | Σ I | 1..1 | Element idSpecimen.note:laboratoryInformation.author[x] Individual responsible for the annotation DefinitionThe individual responsible for making the annotation. Organization is used when there's no need for specific attribution as to who made the comment.
| |
id | 0..0 | id | There are no (further) constraints on this element Element idSpecimen.note:laboratoryInformation.author[x].id Unique id for inter-element referencing DefinitionUnique id for the element within a resource (for internal references). This may be any string value that does not contain spaces.
| |
extension | I | 0..* | Extension | There are no (further) constraints on this element Element idSpecimen.note:laboratoryInformation.author[x].extension Additional content defined by implementations Alternate namesextensions, user content DefinitionMay be used to represent additional information that is not part of the basic definition of the element. To make the use of extensions safe and manageable, there is a strict set of governance applied to the definition and use of extensions. Though any implementer can define an extension, there is a set of requirements that SHALL be met as part of the definition of the extension. There can be no stigma associated with the use of extensions by any application, project, or standard - regardless of the institution or jurisdiction that uses or defines the extensions. The use of extensions is what allows the FHIR specification to retain a core level of simplicity for everyone. Unordered, Open, by url(Value) Extensions are always sliced by (at least) url Constraints
|
reference | Σ I | 0..1 | string | There are no (further) constraints on this element Element idSpecimen.note:laboratoryInformation.author[x].reference Literal reference, Relative, internal or absolute URL DefinitionA reference to a location at which the other resource is found. The reference may be a relative reference, in which case it is relative to the service base URL, or an absolute URL that resolves to the location where the resource is found. The reference may be version specific or not. If the reference is not to a FHIR RESTful server, then it should be assumed to be version specific. Internal fragment references (start with '#') refer to contained resources. Using absolute URLs provides a stable scalable approach suitable for a cloud/web context, while using relative/logical references provides a flexible approach suitable for use when trading across closed eco-system boundaries. Absolute URLs do not need to point to a FHIR RESTful server, though this is the preferred approach. If the URL conforms to the structure "/[type]/[id]" then it should be assumed that the reference is to a FHIR RESTful server.
|
type | Σ | 1..1 | uriBinding | There are no (further) constraints on this element Element idSpecimen.note:laboratoryInformation.author[x].type Type the reference refers to (e.g. "Patient") DefinitionThe expected type of the target of the reference. If both Reference.type and Reference.reference are populated and Reference.reference is a FHIR URL, both SHALL be consistent. The type is the Canonical URL of Resource Definition that is the type this reference refers to. References are URLs that are relative to http://hl7.org/fhir/StructureDefinition/ e.g. "Patient" is a reference to http://hl7.org/fhir/StructureDefinition/Patient. Absolute URLs are only allowed for logical models (and can only be used in references in logical models, not resources). This element is used to indicate the type of the target of the reference. This may be used which ever of the other elements are populated (or not). In some cases, the type of the target may be determined by inspection of the reference (e.g. a RESTful URL) or by resolving the target of the reference; if both the type and a reference is provided, the reference SHALL resolve to a resource of the same type as that specified.
|
identifier | Σ | 0..0 | Identifier | There are no (further) constraints on this element Element idSpecimen.note:laboratoryInformation.author[x].identifier Logical reference, when literal reference is not known DefinitionAn identifier for the target resource. This is used when there is no way to reference the other resource directly, either because the entity it represents is not available through a FHIR server, or because there is no way for the author of the resource to convert a known identifier to an actual location. There is no requirement that a Reference.identifier point to something that is actually exposed as a FHIR instance, but it SHALL point to a business concept that would be expected to be exposed as a FHIR instance, and that instance would need to be of a FHIR resource type allowed by the reference. When an identifier is provided in place of a reference, any system processing the reference will only be able to resolve the identifier to a reference if it understands the business context in which the identifier is used. Sometimes this is global (e.g. a national identifier) but often it is not. For this reason, none of the useful mechanisms described for working with references (e.g. chaining, includes) are possible, nor should servers be expected to be able resolve the reference. Servers may accept an identifier based reference untouched, resolve it, and/or reject it - see CapabilityStatement.rest.resource.referencePolicy. When both an identifier and a literal reference are provided, the literal reference is preferred. Applications processing the resource are allowed - but not required - to check that the identifier matches the literal reference Applications converting a logical reference to a literal reference may choose to leave the logical reference present, or remove it. Reference is intended to point to a structure that can potentially be expressed as a FHIR resource, though there is no need for it to exist as an actual FHIR resource instance - except in as much as an application wishes to actual find the target of the reference. The content referred to be the identifier must meet the logical constraints implied by any limitations on what resource types are permitted for the reference. For example, it would not be legitimate to send the identifier for a drug prescription if the type were Reference(Observation|DiagnosticReport). One of the use-cases for Reference.identifier is the situation where no FHIR representation exists (where the type is Reference (Any).
|
display | Σ | 0..1 | string | There are no (further) constraints on this element Element idSpecimen.note:laboratoryInformation.author[x].display Text alternative for the resource DefinitionPlain text narrative that identifies the resource in addition to the resource reference. This is generally not the same as the Resource.text of the referenced resource. The purpose is to identify what's being referenced, not to fully describe it.
|
authorReference | Reference(Practitioner | Organization) | Data type | ||
time | Σ I | 1..1 | dateTime | Element idSpecimen.note:laboratoryInformation.time When the annotation was made DefinitionIndicates when this particular annotation was made. ©NHS: Datetime is expected.
|
text | Σ | 1..1 | markdown | Element idSpecimen.note:laboratoryInformation.text The annotation - text content (as markdown) DefinitionThe text of the annotation in markdown format. ©NHS: Laboratory provided notes about specimen are expected.
|
Izsaukuma veikšana
Parauga datu reģistrācijai tiek izmantots POST pieprasījumi. Parauga datu reģistrācijai tiek izmantots PUT pieprasījumi.
Resursu reģistrācija ir asinhronais process. Lai iegūtu reģistrācijas pieprasījuma statusu jāveic uzdevuma statusa izgūšanas pieprasījums (sk. Asinhronie datu izmaiņu pieprasījumi).