eps-issue-code-to-fhir-issue-type

Url
https://fhir.nhs.uk/ConceptMap/eps-issue-code-to-fhir-issue-type
Source CodeSystem Destination CodeSystem
https://fhir.nhs.uk/CodeSystem/EPS-IssueCode http://hl7.org/fhir/issue-type

SourceEquivalenceDestinationComment
PATIENT_DECEASED (Patient is recorded as dead)specializesbusiness-rule (Business Rule Violation)HTTP code: 422
DUPLICATE_PRESCRIPTION_ID (Duplicate prescription ID exists)specializesduplicate (Duplicate)HTTP code: 422
INVALID_NUMBER_MEDICATIONREQUEST (Number of items on a prescription should be between 1 and 4)specializesbusiness-rule (Business Rule Violation)HTTP code: 422
MISMATCH_AUTHORISED_REPEAT_COUNT (Mismatch in authorised repeat counts)specializesbusiness-rule (Business Rule Violation)HTTP code: 422
INVALID_REPEAT_COUNT (Repeat count should be between 1 and 99)specializesbusiness-rule (Business Rule Violation)HTTP code: 422
DUPLICATE_MEDICATIONREQUEST_ID (Duplicate item ID exists)specializesduplicate (Duplicate)HTTP code: 422
INVALID_CHECK_DIGIT (Error in check digit)specializesvalue (Element value invalid)HTTP code: 400
INVALID_MESSAGE (Invalid message)specializesstructure (Structural Issue)HTTP code: 400
{
    "resourceType": "ConceptMap",
    "id": "eps-issue-code-to-fhir-issue-type",
    "url": "https://fhir.nhs.uk/ConceptMap/eps-issue-code-to-fhir-issue-type",
    "version": "1.1.0",
    "name": "EPSissuecodetofhirissuetype",
    "title": "EPS Issue Code to FHIR Issue Type Map",
    "status": "draft",
    "experimental": true,
    "date": "2020-08-05",
    "publisher": "NHS Digital",
    "description": "EPS Issue Code to FHIR Issue Type Map",
    "purpose": "NHS Digital Spine",
    "group":  [
        {
            "source": "https://fhir.nhs.uk/CodeSystem/EPS-IssueCode",
            "target": "http://hl7.org/fhir/issue-type",
            "element":  [
                {
                    "code": "PATIENT_DECEASED",
                    "display": "Patient is recorded as dead",
                    "target":  [
                        {
                            "code": "business-rule",
                            "display": "Business Rule Violation",
                            "equivalence": "specializes",
                            "comment": "HTTP code: 422"
                        }
                    ]
                },
                {
                    "code": "DUPLICATE_PRESCRIPTION_ID",
                    "display": "Duplicate prescription ID exists",
                    "target":  [
                        {
                            "code": "duplicate",
                            "display": "Duplicate",
                            "equivalence": "specializes",
                            "comment": "HTTP code: 422"
                        }
                    ]
                },
                {
                    "code": "INVALID_NUMBER_MEDICATIONREQUEST",
                    "display": "Number of items on a prescription should be between 1 and 4",
                    "target":  [
                        {
                            "code": "business-rule",
                            "display": "Business Rule Violation",
                            "equivalence": "specializes",
                            "comment": "HTTP code: 422"
                        }
                    ]
                },
                {
                    "code": "MISMATCH_AUTHORISED_REPEAT_COUNT",
                    "display": "Mismatch in authorised repeat counts",
                    "target":  [
                        {
                            "code": "business-rule",
                            "display": "Business Rule Violation",
                            "equivalence": "specializes",
                            "comment": "HTTP code: 422"
                        }
                    ]
                },
                {
                    "code": "INVALID_REPEAT_COUNT",
                    "display": "Repeat count should be between 1 and 99",
                    "target":  [
                        {
                            "code": "business-rule",
                            "display": "Business Rule Violation",
                            "equivalence": "specializes",
                            "comment": "HTTP code: 422"
                        }
                    ]
                },
                {
                    "code": "DUPLICATE_MEDICATIONREQUEST_ID",
                    "display": "Duplicate item ID exists",
                    "target":  [
                        {
                            "code": "duplicate",
                            "display": "Duplicate",
                            "equivalence": "specializes",
                            "comment": "HTTP code: 422"
                        }
                    ]
                },
                {
                    "code": "INVALID_CHECK_DIGIT",
                    "display": "Error in check digit",
                    "target":  [
                        {
                            "code": "value",
                            "display": "Element value invalid",
                            "equivalence": "specializes",
                            "comment": "HTTP code: 400"
                        }
                    ]
                },
                {
                    "code": "INVALID_MESSAGE",
                    "display": "Invalid message",
                    "target":  [
                        {
                            "code": "structure",
                            "display": "Structural Issue",
                            "equivalence": "specializes",
                            "comment": "HTTP code: 400"
                        }
                    ]
                }
            ]
        }
    ]
}
<ConceptMap xmlns="http://hl7.org/fhir">
    <id value="eps-issue-code-to-fhir-issue-type" />
    <url value="https://fhir.nhs.uk/ConceptMap/eps-issue-code-to-fhir-issue-type" />
    <version value="1.1.0" />
    <name value="EPSissuecodetofhirissuetype" />
    <title value="EPS Issue Code to FHIR Issue Type Map" />
    <status value="draft" />
    <experimental value="true" />
    <date value="2020-08-05" />
    <publisher value="NHS Digital" />
    <description value="EPS Issue Code to FHIR Issue Type Map" />
    <purpose value="NHS Digital Spine" />
    <group>
        <source value="https://fhir.nhs.uk/CodeSystem/EPS-IssueCode" />
        <target value="http://hl7.org/fhir/issue-type" />
        <element>
            <code value="PATIENT_DECEASED" />
            <display value="Patient is recorded as dead" />
            <target>
                <code value="business-rule" />
                <display value="Business Rule Violation" />
                <equivalence value="specializes" />
                <comment value="HTTP code: 422" />
            </target>
        </element>
        <element>
            <code value="DUPLICATE_PRESCRIPTION_ID" />
            <display value="Duplicate prescription ID exists" />
            <target>
                <code value="duplicate" />
                <display value="Duplicate" />
                <equivalence value="specializes" />
                <comment value="HTTP code: 422" />
            </target>
        </element>
        <element>
            <code value="INVALID_NUMBER_MEDICATIONREQUEST" />
            <display value="Number of items on a prescription should be between 1 and 4" />
            <target>
                <code value="business-rule" />
                <display value="Business Rule Violation" />
                <equivalence value="specializes" />
                <comment value="HTTP code: 422" />
            </target>
        </element>
        <element>
            <code value="MISMATCH_AUTHORISED_REPEAT_COUNT" />
            <display value="Mismatch in authorised repeat counts" />
            <target>
                <code value="business-rule" />
                <display value="Business Rule Violation" />
                <equivalence value="specializes" />
                <comment value="HTTP code: 422" />
            </target>
        </element>
        <element>
            <code value="INVALID_REPEAT_COUNT" />
            <display value="Repeat count should be between 1 and 99" />
            <target>
                <code value="business-rule" />
                <display value="Business Rule Violation" />
                <equivalence value="specializes" />
                <comment value="HTTP code: 422" />
            </target>
        </element>
        <element>
            <code value="DUPLICATE_MEDICATIONREQUEST_ID" />
            <display value="Duplicate item ID exists" />
            <target>
                <code value="duplicate" />
                <display value="Duplicate" />
                <equivalence value="specializes" />
                <comment value="HTTP code: 422" />
            </target>
        </element>
        <element>
            <code value="INVALID_CHECK_DIGIT" />
            <display value="Error in check digit" />
            <target>
                <code value="value" />
                <display value="Element value invalid" />
                <equivalence value="specializes" />
                <comment value="HTTP code: 400" />
            </target>
        </element>
        <element>
            <code value="INVALID_MESSAGE" />
            <display value="Invalid message" />
            <target>
                <code value="structure" />
                <display value="Structural Issue" />
                <equivalence value="specializes" />
                <comment value="HTTP code: 400" />
            </target>
        </element>
    </group>
</ConceptMap>