Device

Tree View

system..0
version..0
codeFixed Value
displayFixed Value
userSelected..0
valueS
codingcoding with translations
systemS1..Fixed Value
codeS1..
deviceSCodeable ConceptBinding
manufactureDate
expirationDate
referenceS
identifier..0
Device
Comments

This profile applies the rules defined by HL7 International for representing the UDI in the FHIR standard, by the document "Medical Devices and Unique Device Identification (UDI) Pattern, Release 1"

Device.identifier
Cardinality...1
Must SupportTrue
Device.identifier.type
DefinitionThe type of identifier represents "serial number" (SNO)
Must SupportTrue
Device.identifier.type.coding.system
Cardinality...0
Device.identifier.type.coding.version
Cardinality...0
Device.identifier.type.coding.code
Fixed Value

SNO

Device.identifier.type.coding.display
Fixed Value

serial number

Device.identifier.type.coding.userSelected
Cardinality...0
Device.identifier.value
DefinitionThe serial number of the medical device
Must SupportTrue
Device.type
Comments

The FHIR-defined value set is different from the value set "IPS Medical Devices" defined by the IPS CDA IG: http://art-decor.org/art-decor/decor-valuesets--hl7ips-?id=2.16.840.1.113883.11.22.23&effectiveDate=2017-07-19T00:00:00&language=en-US

SlicingUnordered, Open, by coding.system(Value)
Device.type.coding
Typecoding with translations
Device.type:absentOrUnknownDevice
TypeCodeable Concept
Binding
Codes for absent or for unknown devices
IPSNoDevicesInfos (required)
Must SupportTrue
Device.type:absentOrUnknownDevice.coding
Cardinality1...1
Must SupportTrue
Device.type:absentOrUnknownDevice.coding.system
Cardinality1
Must SupportTrue
Fixed Value

http://hl7.org/fhir/ips/CodeSystem/absent-unknown

Device.type:absentOrUnknownDevice.coding.code
Cardinality1
Must SupportTrue
Device.type:device
TypeCodeable Concept
BindingIPSMedicalDevices (preferred)
Must SupportTrue
Device.manufactureDate
DefinitionThe date and time when the device was manufactured. If hour is present, minutes and seconds should be both set to "00"
Device.expirationDate
DefinitionThe date and time beyond which this device is no longer valid or should not be used (if applicable). If hour is present, minutes and seconds should be both set to "00".
Device.patient
Cardinality1
TypeReference(Patient-uv-ips)
Must SupportTrue
Device.patient.reference
Must SupportTrue
Device.patient.identifier
Cardinality...0