Important: This is a draft IG for trial use. Click here to give feedback.
HdBe-MedicalDevice-01 example
{ "resourceType": "DeviceUseStatement", "id": "HdBe-MedicalDevice-01", "meta": { "profile": [ "https://fhir.healthdata.be/StructureDefinition/HdBe-MedicalDevice" ] }, "extension": [ { "url": "https://fhir.healthdata.be/StructureDefinition/ext-MedicalDevice.Location", "valueReference": { "reference": "Location/HdBe-HealthcareOrganization-01", "type": "Location", "display": "Healthcare organization (location), GRAND HOPITAL DE CHARLEROI - SAINT-JOSEPH" } }, { "url": "https://fhir.healthdata.be/StructureDefinition/ext-MedicalDevice.HealthProfessional", "valueReference": { "reference": "PractitionerRole/HdBe-HealthProfessional-PractitionerRole-01", "type": "PractitionerRole", "display": "Healthcare professional (role), Dermatology" } } ], "status": "active", "subject": { "reference": "Patient/HdBe-Patient-01", "type": "Patient", "display": "Belle Ulijn" }, "timingPeriod": { "start": "2022-05-01" }, "device": { "reference": "Device/HdBe-MedicalDevice.Product-01", "type": "Device", "display": "Auditory appliance" }, "reasonReference": [ { "reference": "Condition/HdBe-Problem-01", "type": "Condition", "display": "Problem" } ], "note": [ { "text": "Might need replacement in the near future." } ] }
<DeviceUseStatement xmlns="http://hl7.org/fhir"> <id value="HdBe-MedicalDevice-01" /> <meta> <profile value="https://fhir.healthdata.be/StructureDefinition/HdBe-MedicalDevice" /> </meta> <extension url="https://fhir.healthdata.be/StructureDefinition/ext-MedicalDevice.Location"> <valueReference> <reference value="Location/HdBe-HealthcareOrganization-01" /> <type value="Location" /> <display value="Healthcare organization (location), GRAND HOPITAL DE CHARLEROI - SAINT-JOSEPH" /> </valueReference> </extension> <extension url="https://fhir.healthdata.be/StructureDefinition/ext-MedicalDevice.HealthProfessional"> <valueReference> <reference value="PractitionerRole/HdBe-HealthProfessional-PractitionerRole-01" /> <type value="PractitionerRole" /> <display value="Healthcare professional (role), Dermatology" /> </valueReference> </extension> <status value="active" /> <subject> <reference value="Patient/HdBe-Patient-01" /> <type value="Patient" /> <display value="Belle Ulijn" /> </subject> <timingPeriod> <start value="2022-05-01" /> </timingPeriod> <device> <reference value="Device/HdBe-MedicalDevice.Product-01" /> <type value="Device" /> <display value="Auditory appliance" /> </device> <reasonReference> <reference value="Condition/HdBe-Problem-01" /> <type value="Condition" /> <display value="Problem" /> </reasonReference> <note> <text value="Might need replacement in the near future." /> </note> </DeviceUseStatement>
DeviceUseStatement |
id : HdBe-MedicalDevice-01 |
meta |
profile : https://fhir.healthdata.be/StructureDefinition/HdBe-MedicalDevice |
extension |
url : https://fhir.healthdata.be/StructureDefinition/ext-MedicalDevice.Location |
value |
reference : Location/HdBe-HealthcareOrganization-01 |
type : Location |
display : Healthcare organization (location), GRAND HOPITAL DE CHARLEROI - SAINT-JOSEPH |
extension |
url : https://fhir.healthdata.be/StructureDefinition/ext-MedicalDevice.HealthProfessional |
value |
reference : PractitionerRole/HdBe-HealthProfessional-PractitionerRole-01 |
type : PractitionerRole |
display : Healthcare professional (role), Dermatology |
status : active |
subject |
reference : Patient/HdBe-Patient-01 |
type : Patient |
display : Belle Ulijn |
timing |
start : 2022-05-01 |
device |
reference : Device/HdBe-MedicalDevice.Product-01 |
type : Device |
display : Auditory appliance |
reasonReference |
reference : Condition/HdBe-Problem-01 |
type : Condition |
display : Problem |
note |
text : Might need replacement in the near future. |
DeviceUseStatement.id[0] | HdBe-MedicalDevice-01 |
DeviceUseStatement.meta[0].profile[0] | https://fhir.healthdata.be/StructureDefinition/HdBe-MedicalDevice |
DeviceUseStatement.extension[0].url[0] | https://fhir.healthdata.be/StructureDefinition/ext-MedicalDevice.Location |
DeviceUseStatement.extension[0].value[0].reference[0] | Location/HdBe-HealthcareOrganization-01 |
DeviceUseStatement.extension[0].value[0].type[0] | Location |
DeviceUseStatement.extension[0].value[0].display[0] | Healthcare organization (location), GRAND HOPITAL DE CHARLEROI - SAINT-JOSEPH |
DeviceUseStatement.extension[1].url[0] | https://fhir.healthdata.be/StructureDefinition/ext-MedicalDevice.HealthProfessional |
DeviceUseStatement.extension[1].value[0].reference[0] | PractitionerRole/HdBe-HealthProfessional-PractitionerRole-01 |
DeviceUseStatement.extension[1].value[0].type[0] | PractitionerRole |
DeviceUseStatement.extension[1].value[0].display[0] | Healthcare professional (role), Dermatology |
DeviceUseStatement.status[0] | active |
DeviceUseStatement.subject[0].reference[0] | Patient/HdBe-Patient-01 |
DeviceUseStatement.subject[0].type[0] | Patient |
DeviceUseStatement.subject[0].display[0] | Belle Ulijn |
DeviceUseStatement.timing[0].start[0] | 2022-05-01 |
DeviceUseStatement.device[0].reference[0] | Device/HdBe-MedicalDevice.Product-01 |
DeviceUseStatement.device[0].type[0] | Device |
DeviceUseStatement.device[0].display[0] | Auditory appliance |
DeviceUseStatement.reasonReference[0].reference[0] | Condition/HdBe-Problem-01 |
DeviceUseStatement.reasonReference[0].type[0] | Condition |
DeviceUseStatement.reasonReference[0].display[0] | Problem |
DeviceUseStatement.note[0].text[0] | Might need replacement in the near future. |