Page Status: 2022-10-21

Device

The Device resource is used for data about the test device.

The supported scenarios are:

RAT

idΣ0..1string
metaΣ0..1Meta
implicitRulesΣ ?!0..1uri
language0..1codeBinding
text0..1Narrative
contained0..*Resource
extensionI0..*Extension
modifierExtension?! I0..*Extension
id0..1string
extensionI0..*Extension
useΣ ?!0..1codeBinding
typeΣ0..1CodeableConceptBinding
systemS Σ1..1uriBinding
valueS Σ1..1string
periodΣ I0..1Period
assignerΣ I0..1Reference(Organization)
definitionI0..1Reference(DeviceDefinition)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
deviceIdentifierΣ0..1string
issuer0..1uri
jurisdiction0..1uri
carrierAIDCΣ0..1base64Binary
carrierHRFΣ0..1string
entryType0..1codeBinding
statusΣ ?!0..1codeBinding
statusReason0..*CodeableConceptBinding
distinctIdentifier0..1string
manufacturer0..1string
manufactureDate0..1dateTime
expirationDate0..1dateTime
lotNumber0..1string
serialNumber0..1string
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
name1..1string
type1..1codeBinding
modelNumber0..1string
partNumber0..1string
type0..1CodeableConcept
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
systemType1..1CodeableConcept
version0..1string
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
type0..1CodeableConcept
component0..1Identifier
value1..1string
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
type1..1CodeableConcept
valueQuantityI0..*Quantity
valueCode0..*CodeableConcept
patientI0..1Reference(Patient)
ownerI0..1Reference(Organization)
contactI0..*ContactPoint
locationI0..1Reference(Location)
url0..1uri
note0..*Annotation
safetyΣ0..*CodeableConcept
parentI0..1Reference(Device)

The "identifier" attribute is mandatory and must be provided. The id of the test must be from the EU list of approved tests:

Human readable format:
http://covid-19-diagnostics.jrc.ec.europa.eu/devices?manufacturer&text_name&marking&rapid_diag&format&target_type&field-1=HSC%20common%20list%20%28RAT%29&value-1=1&search_method=AND#form_content

Machine readable format:
https://covid-19-diagnostics.jrc.ec.europa.eu/devices/hsc-common-recognition-rat

The identifier MUST NOT be used for NAAT.

NAAT

idΣ0..1string
metaΣ0..1Meta
implicitRulesΣ ?!0..1uri
language0..1codeBinding
text0..1Narrative
contained0..*Resource
extensionI0..*Extension
modifierExtension?! I0..*Extension
identifier0..*Identifier
definitionI0..1Reference(DeviceDefinition)
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
deviceIdentifierΣ0..1string
issuer0..1uri
jurisdiction0..1uri
carrierAIDCΣ0..1base64Binary
carrierHRFΣ0..1string
entryType0..1codeBinding
statusΣ ?!0..1codeBinding
statusReason0..*CodeableConceptBinding
distinctIdentifier0..1string
manufacturer0..1string
manufactureDate0..1dateTime
expirationDate0..1dateTime
lotNumber0..1string
serialNumber0..1string
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
nameS1..1string
typeS1..1codeBindingFixed Value
modelNumber0..1string
partNumber0..1string
type0..1CodeableConcept
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
systemType1..1CodeableConcept
version0..1string
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
type0..1CodeableConcept
component0..1Identifier
value1..1string
id0..1string
extensionI0..*Extension
modifierExtensionΣ ?! I0..*Extension
type1..1CodeableConcept
valueQuantityI0..*Quantity
valueCode0..*CodeableConcept
patientI0..1Reference(Patient)
ownerI0..1Reference(Organization)
contactI0..*ContactPoint
locationI0..1Reference(Location)
url0..1uri
note0..*Annotation
safetyΣ0..*CodeableConcept
parentI0..1Reference(Device)

The "deviceName" attribute may be used (optional). deviceName MUST NOT be used for RAT.

The Device resource is only used as a contained resource in an Observation.