  "resourceType": "StructureDefinition",
  "id": "f9b7568b-e223-4a49-a4e1-7281aea10533",
  "meta": {
    "lastUpdated": "2020-02-10T17:36:09.822+00:00"
  },
  "url": "http://example.org/fhir/StructureDefinition/ResultItem",
  "name": "ResultItem",
  "status": "draft",
  "date": "2020-02-10T17:36:06.7898817+00:00",
  "fhirVersion": "4.0.0",
  "mapping": [
    {
      "identity": "workflow",
      "uri": "http://hl7.org/fhir/workflow",
      "name": "Workflow Pattern"
    },
    {
      "identity": "sct-concept",
      "uri": "http://snomed.info/conceptdomain",
      "name": "SNOMED CT Concept Domain Binding"
    },
    {
      "identity": "v2",
      "uri": "http://hl7.org/v2",
      "name": "HL7 v2 Mapping"
    },
    {
      "identity": "rim",
      "uri": "http://hl7.org/v3",
      "name": "RIM Mapping"
    },
    {
      "identity": "w5",
      "uri": "http://hl7.org/fhir/fivews",
      "name": "FiveWs Pattern Mapping"
    },
    {
      "identity": "sct-attr",
      "uri": "http://snomed.org/attributebinding",
      "name": "SNOMED CT Attribute Binding"
    }
  ],
  "kind": "resource",
  "abstract": false,
  "type": "Observation",
  "baseDefinition": "http://hl7.org/fhir/StructureDefinition/Observation",
  "derivation": "constraint",
  "differential": {
    "element": [
      {
        "id": "Observation.id",
        "path": "Observation.id",
        "example": [
          {
            "label": "example result id",
            "valueId": "result1"
          }
        ]
      },
      {
        "id": "Observation.basedOn",
        "path": "Observation.basedOn",
        "fixedReference": {
          "reference": "#DialysisResults"
        }
      },
      {
        "id": "Observation.status",
        "path": "Observation.status",
        "fixedCode": "final"
      },
      {
        "id": "Observation.code",
        "path": "Observation.code",
        "binding": {
          "strength": "required",
          "description": "Codes identifying medical device attributes. The MDC (Medical Device Code) valueset is required for communication with a Fresenius dialysis machine.",
          "valueSet": "urn:iso:std:iso:11073:10101"
        }
      },
      {
        "id": "Observation.value[x]",
        "path": "Observation.value[x]",
        "type": [
          {
            "code": "Quantity"
          },
          {
            "code": "string"
          }
        ]
      }
    ]
  }
}