### Finnish PHR Respiratory Rate Profile Finnish PHR profile for FHIR® Observation used in respiratory rate measurements. The profile is based on the [Finnish PHR Vital Signs Base profile](VitalSignsBaseProfile "Finnish PHR Vital Signs Base profile"). |The official URL for this profile is:| |- |http://phr.kanta.fi/StructureDefinition/fiphr-respiratoryrate-stu3 | **The Finnish PHR Respiratory Rate Profile constrains the Finnish PHR Vital Signs Base Profile as follows**: - *Observation.code*: - *Coding.code* fixed to value 9279-1 (Respiratory rate), only fixed value SHALL be used - *Observation.valueQuantity*: - *system* fixed to value http://unitsofmeasure.org, set to mandatory - *unit* fixed to value breaths/min, only fixed value SHALL be used, set to mandatory - *code* fixed to value breaths/min, only fixed value SHALL be used, set to mandatory - *value* set to mandatory - *Observation.component*: removed, not needed **Extensions used in the Finnish PHR Respiratory Rate Profile**: - [Finnish PHR Application Information extension](FinnishPHRApplicationInformationextension "Finnish PHR Application Information extension") extends the Finnish PHR Respiratory Rate Profile with information about the application that created the resource instance Under the Respiratory Rate Profile page can be found subpages for different profile renderings: {{index:current}}